Source size variation and ion effects in the SRS at Daresbury
Source dimensions in the electron storage ring are routinely monitored on a diagnostic beam line. During recent recommissioning of the SRS, following the installation of a second wiggler magnet, relatively poor vacuum conditions were experienced. Large step changes in source size have been measured...
Gespeichert in:
Hauptverfasser: | , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3596 vol.5 |
---|---|
container_issue | |
container_start_page | 3594 |
container_title | |
container_volume | ol. 5 |
creator | Clarke, J.A. Dykes, D.M. Hill, S.F. Hughes, E.A. Poole, M.W. Quinn, P.D. Smith, S.L. Suller, V.P. Welbourne, L.A. |
description | Source dimensions in the electron storage ring are routinely monitored on a diagnostic beam line. During recent recommissioning of the SRS, following the installation of a second wiggler magnet, relatively poor vacuum conditions were experienced. Large step changes in source size have been measured and broad tune signals have been seen, together with other effects characteristic of ion influences. Changes of source size and beam stability as a function of ion clearing electrode voltage have also been observed. This paper summarises all such effects observed and comments on their probable causes. It also includes other data on source dimensions, such as measured emittance coupling and the effect of insertion devices in the lattice.< > |
doi_str_mv | 10.1109/PAC.1993.309728 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>proquest_6IE</sourceid><recordid>TN_cdi_proquest_miscellaneous_26247070</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>309728</ieee_id><sourcerecordid>26247070</sourcerecordid><originalsourceid>FETCH-LOGICAL-i203t-42a80f7b3cc6cf4f245de1735d5af52192e90af3ebadb7b56de079be30b5e0133</originalsourceid><addsrcrecordid>eNotkEFLxDAUhAMiKGvPgqecvLW-JE3THDwsVVdhQbF6Lkn7gpFuuyatsP56K-swMJePGRhCLhlkjIG-eVlXGdNaZAK04uUJSbQqYbFgHERxRpIYP2GRlGVRwDm5rcc5tEij_0H6bYI3kx8HaoaO_iU6h-0UqR_o9IG0fq2pmeidCRjtHA4X5NSZPmLynyvy_nD_Vj2m2-fNU7Xepn5ZndKcmxKcsqJti9bljueyQ6aE7KRxkjPNUYNxAq3prLKy6BCUtijASgQmxIpcH3v3YfyaMU7NzscW-94MOM6x4QXPFShYwKsj6BGx2Qe_M-HQHM8Qv_HQU5s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>26247070</pqid></control><display><type>conference_proceeding</type><title>Source size variation and ion effects in the SRS at Daresbury</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Clarke, J.A. ; Dykes, D.M. ; Hill, S.F. ; Hughes, E.A. ; Poole, M.W. ; Quinn, P.D. ; Smith, S.L. ; Suller, V.P. ; Welbourne, L.A.</creator><creatorcontrib>Clarke, J.A. ; Dykes, D.M. ; Hill, S.F. ; Hughes, E.A. ; Poole, M.W. ; Quinn, P.D. ; Smith, S.L. ; Suller, V.P. ; Welbourne, L.A.</creatorcontrib><description>Source dimensions in the electron storage ring are routinely monitored on a diagnostic beam line. During recent recommissioning of the SRS, following the installation of a second wiggler magnet, relatively poor vacuum conditions were experienced. Large step changes in source size have been measured and broad tune signals have been seen, together with other effects characteristic of ion influences. Changes of source size and beam stability as a function of ion clearing electrode voltage have also been observed. This paper summarises all such effects observed and comments on their probable causes. It also includes other data on source dimensions, such as measured emittance coupling and the effect of insertion devices in the lattice.< ></description><identifier>ISBN: 9780780312036</identifier><identifier>ISBN: 0780312031</identifier><identifier>DOI: 10.1109/PAC.1993.309728</identifier><language>eng</language><publisher>IEEE</publisher><subject>Automatic control ; Data acquisition ; Electron beams ; Laboratories ; Size measurement ; Storage rings ; Superconducting magnets ; Synchrotron radiation ; Undulators ; Vacuum systems</subject><ispartof>IEEE Particle Accelerator Conference, 1993, 1993, Vol.ol. 5, p.3594-3596 vol.5</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/309728$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,2058,4050,4051,27924,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/309728$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Clarke, J.A.</creatorcontrib><creatorcontrib>Dykes, D.M.</creatorcontrib><creatorcontrib>Hill, S.F.</creatorcontrib><creatorcontrib>Hughes, E.A.</creatorcontrib><creatorcontrib>Poole, M.W.</creatorcontrib><creatorcontrib>Quinn, P.D.</creatorcontrib><creatorcontrib>Smith, S.L.</creatorcontrib><creatorcontrib>Suller, V.P.</creatorcontrib><creatorcontrib>Welbourne, L.A.</creatorcontrib><title>Source size variation and ion effects in the SRS at Daresbury</title><title>IEEE Particle Accelerator Conference, 1993</title><addtitle>PAC</addtitle><description>Source dimensions in the electron storage ring are routinely monitored on a diagnostic beam line. During recent recommissioning of the SRS, following the installation of a second wiggler magnet, relatively poor vacuum conditions were experienced. Large step changes in source size have been measured and broad tune signals have been seen, together with other effects characteristic of ion influences. Changes of source size and beam stability as a function of ion clearing electrode voltage have also been observed. This paper summarises all such effects observed and comments on their probable causes. It also includes other data on source dimensions, such as measured emittance coupling and the effect of insertion devices in the lattice.< ></description><subject>Automatic control</subject><subject>Data acquisition</subject><subject>Electron beams</subject><subject>Laboratories</subject><subject>Size measurement</subject><subject>Storage rings</subject><subject>Superconducting magnets</subject><subject>Synchrotron radiation</subject><subject>Undulators</subject><subject>Vacuum systems</subject><isbn>9780780312036</isbn><isbn>0780312031</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1993</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkEFLxDAUhAMiKGvPgqecvLW-JE3THDwsVVdhQbF6Lkn7gpFuuyatsP56K-swMJePGRhCLhlkjIG-eVlXGdNaZAK04uUJSbQqYbFgHERxRpIYP2GRlGVRwDm5rcc5tEij_0H6bYI3kx8HaoaO_iU6h-0UqR_o9IG0fq2pmeidCRjtHA4X5NSZPmLynyvy_nD_Vj2m2-fNU7Xepn5ZndKcmxKcsqJti9bljueyQ6aE7KRxkjPNUYNxAq3prLKy6BCUtijASgQmxIpcH3v3YfyaMU7NzscW-94MOM6x4QXPFShYwKsj6BGx2Qe_M-HQHM8Qv_HQU5s</recordid><startdate>1993</startdate><enddate>1993</enddate><creator>Clarke, J.A.</creator><creator>Dykes, D.M.</creator><creator>Hill, S.F.</creator><creator>Hughes, E.A.</creator><creator>Poole, M.W.</creator><creator>Quinn, P.D.</creator><creator>Smith, S.L.</creator><creator>Suller, V.P.</creator><creator>Welbourne, L.A.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope><scope>7SC</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>1993</creationdate><title>Source size variation and ion effects in the SRS at Daresbury</title><author>Clarke, J.A. ; Dykes, D.M. ; Hill, S.F. ; Hughes, E.A. ; Poole, M.W. ; Quinn, P.D. ; Smith, S.L. ; Suller, V.P. ; Welbourne, L.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i203t-42a80f7b3cc6cf4f245de1735d5af52192e90af3ebadb7b56de079be30b5e0133</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Automatic control</topic><topic>Data acquisition</topic><topic>Electron beams</topic><topic>Laboratories</topic><topic>Size measurement</topic><topic>Storage rings</topic><topic>Superconducting magnets</topic><topic>Synchrotron radiation</topic><topic>Undulators</topic><topic>Vacuum systems</topic><toplevel>online_resources</toplevel><creatorcontrib>Clarke, J.A.</creatorcontrib><creatorcontrib>Dykes, D.M.</creatorcontrib><creatorcontrib>Hill, S.F.</creatorcontrib><creatorcontrib>Hughes, E.A.</creatorcontrib><creatorcontrib>Poole, M.W.</creatorcontrib><creatorcontrib>Quinn, P.D.</creatorcontrib><creatorcontrib>Smith, S.L.</creatorcontrib><creatorcontrib>Suller, V.P.</creatorcontrib><creatorcontrib>Welbourne, L.A.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection><collection>Computer and Information Systems Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Clarke, J.A.</au><au>Dykes, D.M.</au><au>Hill, S.F.</au><au>Hughes, E.A.</au><au>Poole, M.W.</au><au>Quinn, P.D.</au><au>Smith, S.L.</au><au>Suller, V.P.</au><au>Welbourne, L.A.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Source size variation and ion effects in the SRS at Daresbury</atitle><btitle>IEEE Particle Accelerator Conference, 1993</btitle><stitle>PAC</stitle><date>1993</date><risdate>1993</risdate><volume>ol. 5</volume><spage>3594</spage><epage>3596 vol.5</epage><pages>3594-3596 vol.5</pages><isbn>9780780312036</isbn><isbn>0780312031</isbn><abstract>Source dimensions in the electron storage ring are routinely monitored on a diagnostic beam line. During recent recommissioning of the SRS, following the installation of a second wiggler magnet, relatively poor vacuum conditions were experienced. Large step changes in source size have been measured and broad tune signals have been seen, together with other effects characteristic of ion influences. Changes of source size and beam stability as a function of ion clearing electrode voltage have also been observed. This paper summarises all such effects observed and comments on their probable causes. It also includes other data on source dimensions, such as measured emittance coupling and the effect of insertion devices in the lattice.< ></abstract><pub>IEEE</pub><doi>10.1109/PAC.1993.309728</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISBN: 9780780312036 |
ispartof | IEEE Particle Accelerator Conference, 1993, 1993, Vol.ol. 5, p.3594-3596 vol.5 |
issn | |
language | eng |
recordid | cdi_proquest_miscellaneous_26247070 |
source | IEEE Electronic Library (IEL) Conference Proceedings |
subjects | Automatic control Data acquisition Electron beams Laboratories Size measurement Storage rings Superconducting magnets Synchrotron radiation Undulators Vacuum systems |
title | Source size variation and ion effects in the SRS at Daresbury |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T10%3A42%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Source%20size%20variation%20and%20ion%20effects%20in%20the%20SRS%20at%20Daresbury&rft.btitle=IEEE%20Particle%20Accelerator%20Conference,%201993&rft.au=Clarke,%20J.A.&rft.date=1993&rft.volume=ol.%205&rft.spage=3594&rft.epage=3596%20vol.5&rft.pages=3594-3596%20vol.5&rft.isbn=9780780312036&rft.isbn_list=0780312031&rft_id=info:doi/10.1109/PAC.1993.309728&rft_dat=%3Cproquest_6IE%3E26247070%3C/proquest_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=26247070&rft_id=info:pmid/&rft_ieee_id=309728&rfr_iscdi=true |