Correlation of in situ and ex situ responses of the QCM accompanying silver deposition

In situ and ex situ quartz crystal microbalance measurements were made at a 10 MHz AT-cut piezoelectric resonator. A simple test is described to determine whether immersion in a solvent affects the relationship between mass loading and frequency decrease found in air. For mass loadings produced with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied electrochemistry 1996-02, Vol.26 (2), p.171-173
Hauptverfasser: BRUCKENSTEIN, S, KANIGE, K. C, HILLMAN, A. R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 173
container_issue 2
container_start_page 171
container_title Journal of applied electrochemistry
container_volume 26
creator BRUCKENSTEIN, S
KANIGE, K. C
HILLMAN, A. R
description In situ and ex situ quartz crystal microbalance measurements were made at a 10 MHz AT-cut piezoelectric resonator. A simple test is described to determine whether immersion in a solvent affects the relationship between mass loading and frequency decrease found in air. For mass loadings produced with electrodeposited Ag up to 400 mu g cm exp -2 , the resonant frequencies in air and in aqueous solution were found to be linearly proportional to each other with a slope of unity at the 5% significance level.
doi_str_mv 10.1007/BF00364067
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_26094057</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>26094057</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-392504cd2f89a867f64e9ff1ea12531a0de63e62959bef12a77a1e2bd447db403</originalsourceid><addsrcrecordid>eNpFkE1LxDAURYMoOI5u_AVZiAuh-vLRpFlqcVRQRFBxVzLpi1Y6TU064vx7O8ygq3cX5x4el5BjBucMQF9czQCEkqD0DpmwXPOsKESxSyYAnGWFYW_75CClTwAwXMkJeS1DjNjaoQkdDZ42HU3NsKS2qyn-bHLE1IcuYVoDwwfSp_KBWufCorfdquneR6z9xkhr7MPYGFWHZM_bNuHR9k7Jy-z6ubzN7h9v7srL-8zxwgyZMDwH6WruC2MLpb2SaLxnaBnPBbNQoxKouMnNHD3jVmvLkM9rKXU9lyCm5HTj7WP4WmIaqkWTHLat7TAsU8UVGAm5HsGzDehiSCmir_rYLGxcVQyq9XTV_3QjfLK12uRs66PtXJP-GgLW3ynxCzxHbXw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>26094057</pqid></control><display><type>article</type><title>Correlation of in situ and ex situ responses of the QCM accompanying silver deposition</title><source>Springer Online Journals Complete</source><creator>BRUCKENSTEIN, S ; KANIGE, K. C ; HILLMAN, A. R</creator><creatorcontrib>BRUCKENSTEIN, S ; KANIGE, K. C ; HILLMAN, A. R</creatorcontrib><description>In situ and ex situ quartz crystal microbalance measurements were made at a 10 MHz AT-cut piezoelectric resonator. A simple test is described to determine whether immersion in a solvent affects the relationship between mass loading and frequency decrease found in air. For mass loadings produced with electrodeposited Ag up to 400 mu g cm exp -2 , the resonant frequencies in air and in aqueous solution were found to be linearly proportional to each other with a slope of unity at the 5% significance level.</description><identifier>ISSN: 0021-891X</identifier><identifier>EISSN: 1572-8838</identifier><identifier>DOI: 10.1007/BF00364067</identifier><identifier>CODEN: JAELBJ</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Chemistry ; Electrochemistry ; Electrodeposition ; Exact sciences and technology ; General and physical chemistry ; Study of interfaces</subject><ispartof>Journal of applied electrochemistry, 1996-02, Vol.26 (2), p.171-173</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-392504cd2f89a867f64e9ff1ea12531a0de63e62959bef12a77a1e2bd447db403</citedby><cites>FETCH-LOGICAL-c289t-392504cd2f89a867f64e9ff1ea12531a0de63e62959bef12a77a1e2bd447db403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3012536$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>BRUCKENSTEIN, S</creatorcontrib><creatorcontrib>KANIGE, K. C</creatorcontrib><creatorcontrib>HILLMAN, A. R</creatorcontrib><title>Correlation of in situ and ex situ responses of the QCM accompanying silver deposition</title><title>Journal of applied electrochemistry</title><description>In situ and ex situ quartz crystal microbalance measurements were made at a 10 MHz AT-cut piezoelectric resonator. A simple test is described to determine whether immersion in a solvent affects the relationship between mass loading and frequency decrease found in air. For mass loadings produced with electrodeposited Ag up to 400 mu g cm exp -2 , the resonant frequencies in air and in aqueous solution were found to be linearly proportional to each other with a slope of unity at the 5% significance level.</description><subject>Chemistry</subject><subject>Electrochemistry</subject><subject>Electrodeposition</subject><subject>Exact sciences and technology</subject><subject>General and physical chemistry</subject><subject>Study of interfaces</subject><issn>0021-891X</issn><issn>1572-8838</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNpFkE1LxDAURYMoOI5u_AVZiAuh-vLRpFlqcVRQRFBxVzLpi1Y6TU064vx7O8ygq3cX5x4el5BjBucMQF9czQCEkqD0DpmwXPOsKESxSyYAnGWFYW_75CClTwAwXMkJeS1DjNjaoQkdDZ42HU3NsKS2qyn-bHLE1IcuYVoDwwfSp_KBWufCorfdquneR6z9xkhr7MPYGFWHZM_bNuHR9k7Jy-z6ubzN7h9v7srL-8zxwgyZMDwH6WruC2MLpb2SaLxnaBnPBbNQoxKouMnNHD3jVmvLkM9rKXU9lyCm5HTj7WP4WmIaqkWTHLat7TAsU8UVGAm5HsGzDehiSCmir_rYLGxcVQyq9XTV_3QjfLK12uRs66PtXJP-GgLW3ynxCzxHbXw</recordid><startdate>19960201</startdate><enddate>19960201</enddate><creator>BRUCKENSTEIN, S</creator><creator>KANIGE, K. C</creator><creator>HILLMAN, A. R</creator><general>Springer</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19960201</creationdate><title>Correlation of in situ and ex situ responses of the QCM accompanying silver deposition</title><author>BRUCKENSTEIN, S ; KANIGE, K. C ; HILLMAN, A. R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-392504cd2f89a867f64e9ff1ea12531a0de63e62959bef12a77a1e2bd447db403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Chemistry</topic><topic>Electrochemistry</topic><topic>Electrodeposition</topic><topic>Exact sciences and technology</topic><topic>General and physical chemistry</topic><topic>Study of interfaces</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BRUCKENSTEIN, S</creatorcontrib><creatorcontrib>KANIGE, K. C</creatorcontrib><creatorcontrib>HILLMAN, A. R</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Journal of applied electrochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BRUCKENSTEIN, S</au><au>KANIGE, K. C</au><au>HILLMAN, A. R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Correlation of in situ and ex situ responses of the QCM accompanying silver deposition</atitle><jtitle>Journal of applied electrochemistry</jtitle><date>1996-02-01</date><risdate>1996</risdate><volume>26</volume><issue>2</issue><spage>171</spage><epage>173</epage><pages>171-173</pages><issn>0021-891X</issn><eissn>1572-8838</eissn><coden>JAELBJ</coden><abstract>In situ and ex situ quartz crystal microbalance measurements were made at a 10 MHz AT-cut piezoelectric resonator. A simple test is described to determine whether immersion in a solvent affects the relationship between mass loading and frequency decrease found in air. For mass loadings produced with electrodeposited Ag up to 400 mu g cm exp -2 , the resonant frequencies in air and in aqueous solution were found to be linearly proportional to each other with a slope of unity at the 5% significance level.</abstract><cop>Heidelberg</cop><pub>Springer</pub><doi>10.1007/BF00364067</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-891X
ispartof Journal of applied electrochemistry, 1996-02, Vol.26 (2), p.171-173
issn 0021-891X
1572-8838
language eng
recordid cdi_proquest_miscellaneous_26094057
source Springer Online Journals Complete
subjects Chemistry
Electrochemistry
Electrodeposition
Exact sciences and technology
General and physical chemistry
Study of interfaces
title Correlation of in situ and ex situ responses of the QCM accompanying silver deposition
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T15%3A14%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Correlation%20of%20in%20situ%20and%20ex%20situ%20responses%20of%20the%20QCM%20accompanying%20silver%20deposition&rft.jtitle=Journal%20of%20applied%20electrochemistry&rft.au=BRUCKENSTEIN,%20S&rft.date=1996-02-01&rft.volume=26&rft.issue=2&rft.spage=171&rft.epage=173&rft.pages=171-173&rft.issn=0021-891X&rft.eissn=1572-8838&rft.coden=JAELBJ&rft_id=info:doi/10.1007/BF00364067&rft_dat=%3Cproquest_cross%3E26094057%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=26094057&rft_id=info:pmid/&rfr_iscdi=true