Abdominal Wall Expanding System. Intraoperative Abdominal Wall Expansion as a Technique to Repair Giant Incisional Hernia and Laparostoma. New and Long-Term Results From a Three-Center Feasibility Study

Background The abdominal wall expanding system (AWEX) was first applied in 2012 and published in 2017. This novel technique was developed to reconstruct complex incisional hernias and residual skin-grafted laparostoma after treatment of an open abdomen, when primary midline closure was impossible. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical innovation 2022-04, Vol.29 (2), p.169-182
Hauptverfasser: Eucker, Dietmar, Rüedi, Nadine, Luedtke, Clinton, Stern, Oliver, Niebuhr, Henning, Zerz, Andreas, Rosenberg, Robert
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 182
container_issue 2
container_start_page 169
container_title Surgical innovation
container_volume 29
creator Eucker, Dietmar
Rüedi, Nadine
Luedtke, Clinton
Stern, Oliver
Niebuhr, Henning
Zerz, Andreas
Rosenberg, Robert
description Background The abdominal wall expanding system (AWEX) was first applied in 2012 and published in 2017. This novel technique was developed to reconstruct complex incisional hernias and residual skin-grafted laparostoma after treatment of an open abdomen, when primary midline closure was impossible. The main aim was the anatomical reconstruction of the abdominal wall and the avoidance of dissecting techniques (component separation). Methods Between 2012 and 2019, 33 patients underwent AWEX hernia repair in three certified hernia centers. The retracted abdominal wall was stretched with the AWEX system intraoperatively for approximately 30 min. Hernia size was measured preoperatively, on CT, and intraoperatively. The gain in length on the lateral abdominal wall (decrease in width of the defect) after stretching and any residual midline gap were determined in the OR. Results 33 patients underwent AWEX procedures. Six cases were evaluated separately because of additional procedures (TAR, four cases) and preoperative application of botulinum toxin (two cases). The median (95% confidence interval) measured width of hernia defects was 13 (12–16) cm, the median gain in length on the lateral abdominal wall was 12 (10–15) cm. After median follow-up of 29 (12–54) months, one recurrence from the broken mesh was observed. No method-related complications occurred. Conclusion Based on the 2017 and current results, the AWEX system represents an alternative or supplemental procedure to current techniques for complex abdominal wall reconstruction. The system proved again to be time-saving, safe, effective, and easy to learn. Further studies with enhanced technology are in progress.
doi_str_mv 10.1177/15533506211041477
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2574408391</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_15533506211041477</sage_id><sourcerecordid>2574408391</sourcerecordid><originalsourceid>FETCH-LOGICAL-c270t-bccccbac0c4a4ce620f5b1b2128a064d489bc1b6b718765fa481755be2ca086d3</originalsourceid><addsrcrecordid>eNp9kc9O3DAQh62qVfnTPkAvyMdesrUTOw5HtGIBaVWkslWP0diZXYwSO9gOsK_IU-HVUi5F9cXW6Pt9o_EQ8o2zGedK_eBSVpVkdck5E1wo9YEc7mpFJbn4-PZm9QE5ivGOMSE5k5_JQSVkxWopD8nzme78YB309A_0PT1_GsF11m3ozTYmHGb0yqUAfsQAyT4gfY-P1jsKkQJdobl19n5Cmjz9hSPYQC8suJQ1xu64HLzE4CzQ3IcuYYTgY_IDzOhPfNwXvdsUKwxDNsSpT5Eugh929tuAWMzRJQx0gRCttr1NW3qTpm77hXxaQx_x6-t9TH4vzlfzy2J5fXE1P1sWplQsFdrko8EwI0AYrEu2lprrkpcNsFp0ojnVhutaK96oWq5BNFxJqbE0wJq6q47J9713DD5PGlM72Giw78Ghn2JbSiUEa6pTnlG-R00eMgZct2OwA4Rty1m7W2H7zwpz5uRVP-kBu7fE351lYLYHImywvfNTyJ8a_2N8AfQJpsc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2574408391</pqid></control><display><type>article</type><title>Abdominal Wall Expanding System. Intraoperative Abdominal Wall Expansion as a Technique to Repair Giant Incisional Hernia and Laparostoma. New and Long-Term Results From a Three-Center Feasibility Study</title><source>SAGE Complete</source><source>Alma/SFX Local Collection</source><creator>Eucker, Dietmar ; Rüedi, Nadine ; Luedtke, Clinton ; Stern, Oliver ; Niebuhr, Henning ; Zerz, Andreas ; Rosenberg, Robert</creator><creatorcontrib>Eucker, Dietmar ; Rüedi, Nadine ; Luedtke, Clinton ; Stern, Oliver ; Niebuhr, Henning ; Zerz, Andreas ; Rosenberg, Robert</creatorcontrib><description>Background The abdominal wall expanding system (AWEX) was first applied in 2012 and published in 2017. This novel technique was developed to reconstruct complex incisional hernias and residual skin-grafted laparostoma after treatment of an open abdomen, when primary midline closure was impossible. The main aim was the anatomical reconstruction of the abdominal wall and the avoidance of dissecting techniques (component separation). Methods Between 2012 and 2019, 33 patients underwent AWEX hernia repair in three certified hernia centers. The retracted abdominal wall was stretched with the AWEX system intraoperatively for approximately 30 min. Hernia size was measured preoperatively, on CT, and intraoperatively. The gain in length on the lateral abdominal wall (decrease in width of the defect) after stretching and any residual midline gap were determined in the OR. Results 33 patients underwent AWEX procedures. Six cases were evaluated separately because of additional procedures (TAR, four cases) and preoperative application of botulinum toxin (two cases). The median (95% confidence interval) measured width of hernia defects was 13 (12–16) cm, the median gain in length on the lateral abdominal wall was 12 (10–15) cm. After median follow-up of 29 (12–54) months, one recurrence from the broken mesh was observed. No method-related complications occurred. Conclusion Based on the 2017 and current results, the AWEX system represents an alternative or supplemental procedure to current techniques for complex abdominal wall reconstruction. The system proved again to be time-saving, safe, effective, and easy to learn. Further studies with enhanced technology are in progress.</description><identifier>ISSN: 1553-3506</identifier><identifier>EISSN: 1553-3514</identifier><identifier>DOI: 10.1177/15533506211041477</identifier><identifier>PMID: 34530655</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><ispartof>Surgical innovation, 2022-04, Vol.29 (2), p.169-182</ispartof><rights>The Author(s) 2021</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c270t-bccccbac0c4a4ce620f5b1b2128a064d489bc1b6b718765fa481755be2ca086d3</citedby><cites>FETCH-LOGICAL-c270t-bccccbac0c4a4ce620f5b1b2128a064d489bc1b6b718765fa481755be2ca086d3</cites><orcidid>0000-0001-6846-8193</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/15533506211041477$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/15533506211041477$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,776,780,21798,27901,27902,43597,43598</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34530655$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Eucker, Dietmar</creatorcontrib><creatorcontrib>Rüedi, Nadine</creatorcontrib><creatorcontrib>Luedtke, Clinton</creatorcontrib><creatorcontrib>Stern, Oliver</creatorcontrib><creatorcontrib>Niebuhr, Henning</creatorcontrib><creatorcontrib>Zerz, Andreas</creatorcontrib><creatorcontrib>Rosenberg, Robert</creatorcontrib><title>Abdominal Wall Expanding System. Intraoperative Abdominal Wall Expansion as a Technique to Repair Giant Incisional Hernia and Laparostoma. New and Long-Term Results From a Three-Center Feasibility Study</title><title>Surgical innovation</title><addtitle>Surg Innov</addtitle><description>Background The abdominal wall expanding system (AWEX) was first applied in 2012 and published in 2017. This novel technique was developed to reconstruct complex incisional hernias and residual skin-grafted laparostoma after treatment of an open abdomen, when primary midline closure was impossible. The main aim was the anatomical reconstruction of the abdominal wall and the avoidance of dissecting techniques (component separation). Methods Between 2012 and 2019, 33 patients underwent AWEX hernia repair in three certified hernia centers. The retracted abdominal wall was stretched with the AWEX system intraoperatively for approximately 30 min. Hernia size was measured preoperatively, on CT, and intraoperatively. The gain in length on the lateral abdominal wall (decrease in width of the defect) after stretching and any residual midline gap were determined in the OR. Results 33 patients underwent AWEX procedures. Six cases were evaluated separately because of additional procedures (TAR, four cases) and preoperative application of botulinum toxin (two cases). The median (95% confidence interval) measured width of hernia defects was 13 (12–16) cm, the median gain in length on the lateral abdominal wall was 12 (10–15) cm. After median follow-up of 29 (12–54) months, one recurrence from the broken mesh was observed. No method-related complications occurred. Conclusion Based on the 2017 and current results, the AWEX system represents an alternative or supplemental procedure to current techniques for complex abdominal wall reconstruction. The system proved again to be time-saving, safe, effective, and easy to learn. Further studies with enhanced technology are in progress.</description><issn>1553-3506</issn><issn>1553-3514</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kc9O3DAQh62qVfnTPkAvyMdesrUTOw5HtGIBaVWkslWP0diZXYwSO9gOsK_IU-HVUi5F9cXW6Pt9o_EQ8o2zGedK_eBSVpVkdck5E1wo9YEc7mpFJbn4-PZm9QE5ivGOMSE5k5_JQSVkxWopD8nzme78YB309A_0PT1_GsF11m3ozTYmHGb0yqUAfsQAyT4gfY-P1jsKkQJdobl19n5Cmjz9hSPYQC8suJQ1xu64HLzE4CzQ3IcuYYTgY_IDzOhPfNwXvdsUKwxDNsSpT5Eugh929tuAWMzRJQx0gRCttr1NW3qTpm77hXxaQx_x6-t9TH4vzlfzy2J5fXE1P1sWplQsFdrko8EwI0AYrEu2lprrkpcNsFp0ojnVhutaK96oWq5BNFxJqbE0wJq6q47J9713DD5PGlM72Giw78Ghn2JbSiUEa6pTnlG-R00eMgZct2OwA4Rty1m7W2H7zwpz5uRVP-kBu7fE351lYLYHImywvfNTyJ8a_2N8AfQJpsc</recordid><startdate>202204</startdate><enddate>202204</enddate><creator>Eucker, Dietmar</creator><creator>Rüedi, Nadine</creator><creator>Luedtke, Clinton</creator><creator>Stern, Oliver</creator><creator>Niebuhr, Henning</creator><creator>Zerz, Andreas</creator><creator>Rosenberg, Robert</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-6846-8193</orcidid></search><sort><creationdate>202204</creationdate><title>Abdominal Wall Expanding System. Intraoperative Abdominal Wall Expansion as a Technique to Repair Giant Incisional Hernia and Laparostoma. New and Long-Term Results From a Three-Center Feasibility Study</title><author>Eucker, Dietmar ; Rüedi, Nadine ; Luedtke, Clinton ; Stern, Oliver ; Niebuhr, Henning ; Zerz, Andreas ; Rosenberg, Robert</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c270t-bccccbac0c4a4ce620f5b1b2128a064d489bc1b6b718765fa481755be2ca086d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Eucker, Dietmar</creatorcontrib><creatorcontrib>Rüedi, Nadine</creatorcontrib><creatorcontrib>Luedtke, Clinton</creatorcontrib><creatorcontrib>Stern, Oliver</creatorcontrib><creatorcontrib>Niebuhr, Henning</creatorcontrib><creatorcontrib>Zerz, Andreas</creatorcontrib><creatorcontrib>Rosenberg, Robert</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Surgical innovation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Eucker, Dietmar</au><au>Rüedi, Nadine</au><au>Luedtke, Clinton</au><au>Stern, Oliver</au><au>Niebuhr, Henning</au><au>Zerz, Andreas</au><au>Rosenberg, Robert</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Abdominal Wall Expanding System. Intraoperative Abdominal Wall Expansion as a Technique to Repair Giant Incisional Hernia and Laparostoma. New and Long-Term Results From a Three-Center Feasibility Study</atitle><jtitle>Surgical innovation</jtitle><addtitle>Surg Innov</addtitle><date>2022-04</date><risdate>2022</risdate><volume>29</volume><issue>2</issue><spage>169</spage><epage>182</epage><pages>169-182</pages><issn>1553-3506</issn><eissn>1553-3514</eissn><abstract>Background The abdominal wall expanding system (AWEX) was first applied in 2012 and published in 2017. This novel technique was developed to reconstruct complex incisional hernias and residual skin-grafted laparostoma after treatment of an open abdomen, when primary midline closure was impossible. The main aim was the anatomical reconstruction of the abdominal wall and the avoidance of dissecting techniques (component separation). Methods Between 2012 and 2019, 33 patients underwent AWEX hernia repair in three certified hernia centers. The retracted abdominal wall was stretched with the AWEX system intraoperatively for approximately 30 min. Hernia size was measured preoperatively, on CT, and intraoperatively. The gain in length on the lateral abdominal wall (decrease in width of the defect) after stretching and any residual midline gap were determined in the OR. Results 33 patients underwent AWEX procedures. Six cases were evaluated separately because of additional procedures (TAR, four cases) and preoperative application of botulinum toxin (two cases). The median (95% confidence interval) measured width of hernia defects was 13 (12–16) cm, the median gain in length on the lateral abdominal wall was 12 (10–15) cm. After median follow-up of 29 (12–54) months, one recurrence from the broken mesh was observed. No method-related complications occurred. Conclusion Based on the 2017 and current results, the AWEX system represents an alternative or supplemental procedure to current techniques for complex abdominal wall reconstruction. The system proved again to be time-saving, safe, effective, and easy to learn. Further studies with enhanced technology are in progress.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>34530655</pmid><doi>10.1177/15533506211041477</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0001-6846-8193</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1553-3506
ispartof Surgical innovation, 2022-04, Vol.29 (2), p.169-182
issn 1553-3506
1553-3514
language eng
recordid cdi_proquest_miscellaneous_2574408391
source SAGE Complete; Alma/SFX Local Collection
title Abdominal Wall Expanding System. Intraoperative Abdominal Wall Expansion as a Technique to Repair Giant Incisional Hernia and Laparostoma. New and Long-Term Results From a Three-Center Feasibility Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T19%3A49%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Abdominal%20Wall%20Expanding%20System.%20Intraoperative%20Abdominal%20Wall%20Expansion%20as%20a%20Technique%20to%20Repair%20Giant%20Incisional%20Hernia%20and%20Laparostoma.%20New%20and%20Long-Term%20Results%20From%20a%20Three-Center%20Feasibility%20Study&rft.jtitle=Surgical%20innovation&rft.au=Eucker,%20Dietmar&rft.date=2022-04&rft.volume=29&rft.issue=2&rft.spage=169&rft.epage=182&rft.pages=169-182&rft.issn=1553-3506&rft.eissn=1553-3514&rft_id=info:doi/10.1177/15533506211041477&rft_dat=%3Cproquest_cross%3E2574408391%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2574408391&rft_id=info:pmid/34530655&rft_sage_id=10.1177_15533506211041477&rfr_iscdi=true