Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction
Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality. The purpose of this study was to compare standard shoulder MRI...
Gespeichert in:
Veröffentlicht in: | American journal of roentgenology (1976) 2022-03, Vol.218 (3), p.506-516 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 516 |
---|---|
container_issue | 3 |
container_start_page | 506 |
container_title | American journal of roentgenology (1976) |
container_volume | 218 |
creator | Hahn, Seok Yi, Jisook Lee, Ho-Joon Lee, Yedaun Lim, Yun-Jung Bang, Jin-Young Kim, Hyunwoong Lee, Joonsung |
description | Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality.
The purpose of this study was to compare standard shoulder MRI sequences and accelerated sequences without and with DLR in terms of image quality and diagnostic performance.
This retrospective study included 105 patients (45 men, 60 women; mean age, 57.6 ± 10.9 [SD] years) who underwent a total of 110 3-T shoulder MRI examinations. Examinations included standard sequences (scan time, 9 minutes 23 seconds) and accelerated sequences (3 minutes 5 seconds; 67% reduction), both including fast spin-echo sequences in three planes. Standard sequences were reconstructed using the conventional pipeline; accelerated sequences were reconstructed using both the conventional pipeline and a commercially available DLR pipeline. Two radiologists independently assessed three image sets (standard sequence, accelerated sequence without DLR, and accelerated sequence with DLR) for subjective image quality and artifacts using 4-point scales (4 = highest quality) and identified pathologies of the subscapularis tendon, supraspinatus-infraspinatus tendon, long head of the biceps brachii tendon, and glenoid labrum. Interobserver agreement and agreement between image sets for the evaluated pathologies were assessed using weighted kappa statistics. In 27 patients who underwent arthroscopy, diagnostic performance was calculated using arthroscopic findings as a reference standard.
Mean subjective image quality scores for readers 1 and 2 were 10.6 ± 1.2 and 10.5 ± 1.4 for the standard sequence, 8.1 ± 1.3 and 7.2 ± 1.1 for the accelerated sequence without DLR, and 10.7 ± 1.2 and 10.5 ± 1.6 for the accelerated sequence with DLR. Mean artifact scores for readers 1 and 2 were 9.3 ± 1.2 and 10.0 ± 1.0 for the standard sequence, 7.3 ± 1.3 and 9.1 ± 0.8 for the accelerated sequence without DLR, and 9.4 ± 1.2 and 9.8 ± 0.8 for the accelerated sequence with DLR. Interobserver agreement ranged from kappa of 0.813-0.951 except for accelerated sequence without DLR for the supraspinatus-infraspinatus tendon (κ = 0.673). Agreement between image sets ranged from kappa of 0.809-0.957 except for reader 1 for supraspinatus-infraspinatus tendon (κ = 0.663-0.700). Accuracy, sensitivity, and specificity for tears of the four structures were not different (
> .05) among image |
doi_str_mv | 10.2214/AJR.21.26577 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2572944406</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2572944406</sourcerecordid><originalsourceid>FETCH-LOGICAL-c291t-58f90afd2cbc66e5750d47a5d81644a588d508fa0c8418512718488a6bac8cf63</originalsourceid><addsrcrecordid>eNo90D9PwzAQhnELgWgpbMzIIwMptmMnzlha_hQVAQUEW3R1LiUoiYudDP32pLQw3fLTq9NDyClnQyG4vBzdz4eCD0Wk4niP9LmSURByyfdJn4URDzQLP3rkyPsvxlisk_iQ9EKpRJgo1ifltIIl0ucWyqJZU6gzOilgWVvfFIY-ocutq6A2SG1OR8ZgiQ4azOjLp23LDB19mE_pe9F80gniis4QXF3Uy-AKfKfmaGztG9eaprD1MTnIofR4srsD8nZz_Tq-C2aPt9PxaBYYkfAmUDpPGOSZMAsTRahixTIZg8o0j6QEpXWmmM6BGS25VlzEXEutIVqA0SaPwgE53-6unP1u0TdpVfju9RJqtK1PhYpFIqVkG3qxpcZZ7x3m6coVFbh1ylm66Zt2fVPB09--HT_bLbeLCrN__Bc0_AFFnnWK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2572944406</pqid></control><display><type>article</type><title>Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Hahn, Seok ; Yi, Jisook ; Lee, Ho-Joon ; Lee, Yedaun ; Lim, Yun-Jung ; Bang, Jin-Young ; Kim, Hyunwoong ; Lee, Joonsung</creator><creatorcontrib>Hahn, Seok ; Yi, Jisook ; Lee, Ho-Joon ; Lee, Yedaun ; Lim, Yun-Jung ; Bang, Jin-Young ; Kim, Hyunwoong ; Lee, Joonsung</creatorcontrib><description>Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality.
The purpose of this study was to compare standard shoulder MRI sequences and accelerated sequences without and with DLR in terms of image quality and diagnostic performance.
This retrospective study included 105 patients (45 men, 60 women; mean age, 57.6 ± 10.9 [SD] years) who underwent a total of 110 3-T shoulder MRI examinations. Examinations included standard sequences (scan time, 9 minutes 23 seconds) and accelerated sequences (3 minutes 5 seconds; 67% reduction), both including fast spin-echo sequences in three planes. Standard sequences were reconstructed using the conventional pipeline; accelerated sequences were reconstructed using both the conventional pipeline and a commercially available DLR pipeline. Two radiologists independently assessed three image sets (standard sequence, accelerated sequence without DLR, and accelerated sequence with DLR) for subjective image quality and artifacts using 4-point scales (4 = highest quality) and identified pathologies of the subscapularis tendon, supraspinatus-infraspinatus tendon, long head of the biceps brachii tendon, and glenoid labrum. Interobserver agreement and agreement between image sets for the evaluated pathologies were assessed using weighted kappa statistics. In 27 patients who underwent arthroscopy, diagnostic performance was calculated using arthroscopic findings as a reference standard.
Mean subjective image quality scores for readers 1 and 2 were 10.6 ± 1.2 and 10.5 ± 1.4 for the standard sequence, 8.1 ± 1.3 and 7.2 ± 1.1 for the accelerated sequence without DLR, and 10.7 ± 1.2 and 10.5 ± 1.6 for the accelerated sequence with DLR. Mean artifact scores for readers 1 and 2 were 9.3 ± 1.2 and 10.0 ± 1.0 for the standard sequence, 7.3 ± 1.3 and 9.1 ± 0.8 for the accelerated sequence without DLR, and 9.4 ± 1.2 and 9.8 ± 0.8 for the accelerated sequence with DLR. Interobserver agreement ranged from kappa of 0.813-0.951 except for accelerated sequence without DLR for the supraspinatus-infraspinatus tendon (κ = 0.673). Agreement between image sets ranged from kappa of 0.809-0.957 except for reader 1 for supraspinatus-infraspinatus tendon (κ = 0.663-0.700). Accuracy, sensitivity, and specificity for tears of the four structures were not different (
> .05) among image sets.
Accelerated sequences with DLR provide 67% scan time reduction with similar subjective image quality, artifacts, and diagnostic performance to standard sequences.
Accelerated sequences with DLR may provide an alternative to standard sequences for clinical shoulder MRI.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/AJR.21.26577</identifier><identifier>PMID: 34523950</identifier><language>eng</language><publisher>United States</publisher><subject>Deep Learning ; Female ; Humans ; Image Interpretation, Computer-Assisted - methods ; Magnetic Resonance Imaging - methods ; Male ; Middle Aged ; Reproducibility of Results ; Retrospective Studies ; Sensitivity and Specificity ; Shoulder Injuries - diagnostic imaging ; Shoulder Joint - diagnostic imaging</subject><ispartof>American journal of roentgenology (1976), 2022-03, Vol.218 (3), p.506-516</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c291t-58f90afd2cbc66e5750d47a5d81644a588d508fa0c8418512718488a6bac8cf63</citedby><cites>FETCH-LOGICAL-c291t-58f90afd2cbc66e5750d47a5d81644a588d508fa0c8418512718488a6bac8cf63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,4106,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34523950$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hahn, Seok</creatorcontrib><creatorcontrib>Yi, Jisook</creatorcontrib><creatorcontrib>Lee, Ho-Joon</creatorcontrib><creatorcontrib>Lee, Yedaun</creatorcontrib><creatorcontrib>Lim, Yun-Jung</creatorcontrib><creatorcontrib>Bang, Jin-Young</creatorcontrib><creatorcontrib>Kim, Hyunwoong</creatorcontrib><creatorcontrib>Lee, Joonsung</creatorcontrib><title>Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality.
The purpose of this study was to compare standard shoulder MRI sequences and accelerated sequences without and with DLR in terms of image quality and diagnostic performance.
This retrospective study included 105 patients (45 men, 60 women; mean age, 57.6 ± 10.9 [SD] years) who underwent a total of 110 3-T shoulder MRI examinations. Examinations included standard sequences (scan time, 9 minutes 23 seconds) and accelerated sequences (3 minutes 5 seconds; 67% reduction), both including fast spin-echo sequences in three planes. Standard sequences were reconstructed using the conventional pipeline; accelerated sequences were reconstructed using both the conventional pipeline and a commercially available DLR pipeline. Two radiologists independently assessed three image sets (standard sequence, accelerated sequence without DLR, and accelerated sequence with DLR) for subjective image quality and artifacts using 4-point scales (4 = highest quality) and identified pathologies of the subscapularis tendon, supraspinatus-infraspinatus tendon, long head of the biceps brachii tendon, and glenoid labrum. Interobserver agreement and agreement between image sets for the evaluated pathologies were assessed using weighted kappa statistics. In 27 patients who underwent arthroscopy, diagnostic performance was calculated using arthroscopic findings as a reference standard.
Mean subjective image quality scores for readers 1 and 2 were 10.6 ± 1.2 and 10.5 ± 1.4 for the standard sequence, 8.1 ± 1.3 and 7.2 ± 1.1 for the accelerated sequence without DLR, and 10.7 ± 1.2 and 10.5 ± 1.6 for the accelerated sequence with DLR. Mean artifact scores for readers 1 and 2 were 9.3 ± 1.2 and 10.0 ± 1.0 for the standard sequence, 7.3 ± 1.3 and 9.1 ± 0.8 for the accelerated sequence without DLR, and 9.4 ± 1.2 and 9.8 ± 0.8 for the accelerated sequence with DLR. Interobserver agreement ranged from kappa of 0.813-0.951 except for accelerated sequence without DLR for the supraspinatus-infraspinatus tendon (κ = 0.673). Agreement between image sets ranged from kappa of 0.809-0.957 except for reader 1 for supraspinatus-infraspinatus tendon (κ = 0.663-0.700). Accuracy, sensitivity, and specificity for tears of the four structures were not different (
> .05) among image sets.
Accelerated sequences with DLR provide 67% scan time reduction with similar subjective image quality, artifacts, and diagnostic performance to standard sequences.
Accelerated sequences with DLR may provide an alternative to standard sequences for clinical shoulder MRI.</description><subject>Deep Learning</subject><subject>Female</subject><subject>Humans</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Reproducibility of Results</subject><subject>Retrospective Studies</subject><subject>Sensitivity and Specificity</subject><subject>Shoulder Injuries - diagnostic imaging</subject><subject>Shoulder Joint - diagnostic imaging</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo90D9PwzAQhnELgWgpbMzIIwMptmMnzlha_hQVAQUEW3R1LiUoiYudDP32pLQw3fLTq9NDyClnQyG4vBzdz4eCD0Wk4niP9LmSURByyfdJn4URDzQLP3rkyPsvxlisk_iQ9EKpRJgo1ifltIIl0ucWyqJZU6gzOilgWVvfFIY-ocutq6A2SG1OR8ZgiQ4azOjLp23LDB19mE_pe9F80gniis4QXF3Uy-AKfKfmaGztG9eaprD1MTnIofR4srsD8nZz_Tq-C2aPt9PxaBYYkfAmUDpPGOSZMAsTRahixTIZg8o0j6QEpXWmmM6BGS25VlzEXEutIVqA0SaPwgE53-6unP1u0TdpVfju9RJqtK1PhYpFIqVkG3qxpcZZ7x3m6coVFbh1ylm66Zt2fVPB09--HT_bLbeLCrN__Bc0_AFFnnWK</recordid><startdate>202203</startdate><enddate>202203</enddate><creator>Hahn, Seok</creator><creator>Yi, Jisook</creator><creator>Lee, Ho-Joon</creator><creator>Lee, Yedaun</creator><creator>Lim, Yun-Jung</creator><creator>Bang, Jin-Young</creator><creator>Kim, Hyunwoong</creator><creator>Lee, Joonsung</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202203</creationdate><title>Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction</title><author>Hahn, Seok ; Yi, Jisook ; Lee, Ho-Joon ; Lee, Yedaun ; Lim, Yun-Jung ; Bang, Jin-Young ; Kim, Hyunwoong ; Lee, Joonsung</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c291t-58f90afd2cbc66e5750d47a5d81644a588d508fa0c8418512718488a6bac8cf63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Deep Learning</topic><topic>Female</topic><topic>Humans</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Reproducibility of Results</topic><topic>Retrospective Studies</topic><topic>Sensitivity and Specificity</topic><topic>Shoulder Injuries - diagnostic imaging</topic><topic>Shoulder Joint - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hahn, Seok</creatorcontrib><creatorcontrib>Yi, Jisook</creatorcontrib><creatorcontrib>Lee, Ho-Joon</creatorcontrib><creatorcontrib>Lee, Yedaun</creatorcontrib><creatorcontrib>Lim, Yun-Jung</creatorcontrib><creatorcontrib>Bang, Jin-Young</creatorcontrib><creatorcontrib>Kim, Hyunwoong</creatorcontrib><creatorcontrib>Lee, Joonsung</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hahn, Seok</au><au>Yi, Jisook</au><au>Lee, Ho-Joon</au><au>Lee, Yedaun</au><au>Lim, Yun-Jung</au><au>Bang, Jin-Young</au><au>Kim, Hyunwoong</au><au>Lee, Joonsung</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2022-03</date><risdate>2022</risdate><volume>218</volume><issue>3</issue><spage>506</spage><epage>516</epage><pages>506-516</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><abstract>Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality.
The purpose of this study was to compare standard shoulder MRI sequences and accelerated sequences without and with DLR in terms of image quality and diagnostic performance.
This retrospective study included 105 patients (45 men, 60 women; mean age, 57.6 ± 10.9 [SD] years) who underwent a total of 110 3-T shoulder MRI examinations. Examinations included standard sequences (scan time, 9 minutes 23 seconds) and accelerated sequences (3 minutes 5 seconds; 67% reduction), both including fast spin-echo sequences in three planes. Standard sequences were reconstructed using the conventional pipeline; accelerated sequences were reconstructed using both the conventional pipeline and a commercially available DLR pipeline. Two radiologists independently assessed three image sets (standard sequence, accelerated sequence without DLR, and accelerated sequence with DLR) for subjective image quality and artifacts using 4-point scales (4 = highest quality) and identified pathologies of the subscapularis tendon, supraspinatus-infraspinatus tendon, long head of the biceps brachii tendon, and glenoid labrum. Interobserver agreement and agreement between image sets for the evaluated pathologies were assessed using weighted kappa statistics. In 27 patients who underwent arthroscopy, diagnostic performance was calculated using arthroscopic findings as a reference standard.
Mean subjective image quality scores for readers 1 and 2 were 10.6 ± 1.2 and 10.5 ± 1.4 for the standard sequence, 8.1 ± 1.3 and 7.2 ± 1.1 for the accelerated sequence without DLR, and 10.7 ± 1.2 and 10.5 ± 1.6 for the accelerated sequence with DLR. Mean artifact scores for readers 1 and 2 were 9.3 ± 1.2 and 10.0 ± 1.0 for the standard sequence, 7.3 ± 1.3 and 9.1 ± 0.8 for the accelerated sequence without DLR, and 9.4 ± 1.2 and 9.8 ± 0.8 for the accelerated sequence with DLR. Interobserver agreement ranged from kappa of 0.813-0.951 except for accelerated sequence without DLR for the supraspinatus-infraspinatus tendon (κ = 0.673). Agreement between image sets ranged from kappa of 0.809-0.957 except for reader 1 for supraspinatus-infraspinatus tendon (κ = 0.663-0.700). Accuracy, sensitivity, and specificity for tears of the four structures were not different (
> .05) among image sets.
Accelerated sequences with DLR provide 67% scan time reduction with similar subjective image quality, artifacts, and diagnostic performance to standard sequences.
Accelerated sequences with DLR may provide an alternative to standard sequences for clinical shoulder MRI.</abstract><cop>United States</cop><pmid>34523950</pmid><doi>10.2214/AJR.21.26577</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0361-803X |
ispartof | American journal of roentgenology (1976), 2022-03, Vol.218 (3), p.506-516 |
issn | 0361-803X 1546-3141 |
language | eng |
recordid | cdi_proquest_miscellaneous_2572944406 |
source | American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection |
subjects | Deep Learning Female Humans Image Interpretation, Computer-Assisted - methods Magnetic Resonance Imaging - methods Male Middle Aged Reproducibility of Results Retrospective Studies Sensitivity and Specificity Shoulder Injuries - diagnostic imaging Shoulder Joint - diagnostic imaging |
title | Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T15%3A17%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Image%20Quality%20and%20Diagnostic%20Performance%20of%20Accelerated%20Shoulder%20MRI%20With%20Deep%20Learning-Based%20Reconstruction&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Hahn,%20Seok&rft.date=2022-03&rft.volume=218&rft.issue=3&rft.spage=506&rft.epage=516&rft.pages=506-516&rft.issn=0361-803X&rft.eissn=1546-3141&rft_id=info:doi/10.2214/AJR.21.26577&rft_dat=%3Cproquest_cross%3E2572944406%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2572944406&rft_id=info:pmid/34523950&rfr_iscdi=true |