Bioimpedance as a measure of fluid status in critically ill patients: A systematic review

Objective Precise measurements of fluid status lack valid methods. Bioimpedance is an attractive diagnostic tool because it is noninvasive, quick, and relatively cheap. This systematic review aims to assess the existing evidence of bioimpedance as an accurate measure of fluid status in critically il...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta anaesthesiologica Scandinavica 2021-10, Vol.65 (9), p.1155-1167
Hauptverfasser: Madsen, Janne M., Wichmann, Sine, Bestle, Morten H., Itenov, Theis S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1167
container_issue 9
container_start_page 1155
container_title Acta anaesthesiologica Scandinavica
container_volume 65
creator Madsen, Janne M.
Wichmann, Sine
Bestle, Morten H.
Itenov, Theis S.
description Objective Precise measurements of fluid status lack valid methods. Bioimpedance is an attractive diagnostic tool because it is noninvasive, quick, and relatively cheap. This systematic review aims to assess the existing evidence of bioimpedance as an accurate measure of fluid status in critically ill patients. Data sources PubMed and Embase up till March 2021 were systematically searched (PROSPERO: CRD42020157436). Study selection Eligibility criteria were studies reporting original data from cohorts of adult patients in intensive care units and doing at least one whole‐body bioimpedance and one reference test. In addition, studies assessing internal reproducibility were included. Data extraction An extraction form was designed for the purpose. Data synthesis Nine hundred five studies were screened for eligibility, and 28 studies, comprising 1482 individual patients, were included in the final analysis. Eight studies compared bioimpedance with a gold standard, and two of those reported the results adequate. We found a low mean difference, but the 95% limits of agreements had wide limits. The remaining studies applied different surrogates as reference tests. Correlations ranged from 0.05 to 0.99. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) certainty of evidence for all outcomes was very low. Conclusions The accuracy of bioimpedance as a measure for fluids in critically ill patients in the intensive care unit cannot be determined. Due to the lack of a gold standard, numerous studies compared bioimpedance with surrogate outcomes with great variability in both designs and results. Assessing the internal reproducibility of bioimpedance had the same limitations, but the studies overall reported good internal reproducibility.
doi_str_mv 10.1111/aas.13924
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2532258462</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2574090227</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3304-fa0c152d5e20572b361ab7325bc07ed97ea23dc0ad902a095b0d8446fd559463</originalsourceid><addsrcrecordid>eNp10E1LxDAQBuAgCq6rB_9BwIse6qZJ02691cUvWPDgXjyVaTKFLOmHSevSf2-0ngRzGRKemQkvIZcxu43DWQH421jkPDkii1DzKJVZekwWjLE4knHGT8mZ9_twFUmeL8j7velM06OGViEFT4E2CH50SLua1nY0mvoBhtFT01LlzGAUWDtRYy3tYTDYDv6OFtRPfsAmPCjq8NPg4Zyc1GA9XvzWJdk9Puw2z9H29ellU2wjJQRLohqYiiXXEjmTGa9EGkOVCS4rxTLUeYbAhVYMdM44sFxWTK-TJK21lHmSiiW5nsf2rvsY0Q9lY7xCa6HFbvQll4JzuU5SHujVH7rvRteGzwWVJSws4FlQN7NSrvPeYV32zjTgpjJm5XfGZci4_Mk42NVsD8bi9D8si-Jt7vgCJEN8gw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2574090227</pqid></control><display><type>article</type><title>Bioimpedance as a measure of fluid status in critically ill patients: A systematic review</title><source>Wiley Online Library All Journals</source><creator>Madsen, Janne M. ; Wichmann, Sine ; Bestle, Morten H. ; Itenov, Theis S.</creator><creatorcontrib>Madsen, Janne M. ; Wichmann, Sine ; Bestle, Morten H. ; Itenov, Theis S.</creatorcontrib><description>Objective Precise measurements of fluid status lack valid methods. Bioimpedance is an attractive diagnostic tool because it is noninvasive, quick, and relatively cheap. This systematic review aims to assess the existing evidence of bioimpedance as an accurate measure of fluid status in critically ill patients. Data sources PubMed and Embase up till March 2021 were systematically searched (PROSPERO: CRD42020157436). Study selection Eligibility criteria were studies reporting original data from cohorts of adult patients in intensive care units and doing at least one whole‐body bioimpedance and one reference test. In addition, studies assessing internal reproducibility were included. Data extraction An extraction form was designed for the purpose. Data synthesis Nine hundred five studies were screened for eligibility, and 28 studies, comprising 1482 individual patients, were included in the final analysis. Eight studies compared bioimpedance with a gold standard, and two of those reported the results adequate. We found a low mean difference, but the 95% limits of agreements had wide limits. The remaining studies applied different surrogates as reference tests. Correlations ranged from 0.05 to 0.99. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) certainty of evidence for all outcomes was very low. Conclusions The accuracy of bioimpedance as a measure for fluids in critically ill patients in the intensive care unit cannot be determined. Due to the lack of a gold standard, numerous studies compared bioimpedance with surrogate outcomes with great variability in both designs and results. Assessing the internal reproducibility of bioimpedance had the same limitations, but the studies overall reported good internal reproducibility.</description><identifier>ISSN: 0001-5172</identifier><identifier>EISSN: 1399-6576</identifier><identifier>DOI: 10.1111/aas.13924</identifier><language>eng</language><publisher>Copenhagen: Wiley Subscription Services, Inc</publisher><subject>bioelectrical impedance ; body fluid ; critical illness ; Hospitals ; Intensive care ; intensive care unit ; Intensive care units ; organism hydration status ; Quality ; Reproducibility ; Systematic review</subject><ispartof>Acta anaesthesiologica Scandinavica, 2021-10, Vol.65 (9), p.1155-1167</ispartof><rights>2021 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley &amp; Sons Ltd</rights><rights>Copyright © 2021 The Acta Anaesthesiologica Scandinavica Foundation</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3304-fa0c152d5e20572b361ab7325bc07ed97ea23dc0ad902a095b0d8446fd559463</citedby><cites>FETCH-LOGICAL-c3304-fa0c152d5e20572b361ab7325bc07ed97ea23dc0ad902a095b0d8446fd559463</cites><orcidid>0000-0003-0360-8655 ; 0000-0002-2356-7355</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Faas.13924$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Faas.13924$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27923,27924,45573,45574</link.rule.ids></links><search><creatorcontrib>Madsen, Janne M.</creatorcontrib><creatorcontrib>Wichmann, Sine</creatorcontrib><creatorcontrib>Bestle, Morten H.</creatorcontrib><creatorcontrib>Itenov, Theis S.</creatorcontrib><title>Bioimpedance as a measure of fluid status in critically ill patients: A systematic review</title><title>Acta anaesthesiologica Scandinavica</title><description>Objective Precise measurements of fluid status lack valid methods. Bioimpedance is an attractive diagnostic tool because it is noninvasive, quick, and relatively cheap. This systematic review aims to assess the existing evidence of bioimpedance as an accurate measure of fluid status in critically ill patients. Data sources PubMed and Embase up till March 2021 were systematically searched (PROSPERO: CRD42020157436). Study selection Eligibility criteria were studies reporting original data from cohorts of adult patients in intensive care units and doing at least one whole‐body bioimpedance and one reference test. In addition, studies assessing internal reproducibility were included. Data extraction An extraction form was designed for the purpose. Data synthesis Nine hundred five studies were screened for eligibility, and 28 studies, comprising 1482 individual patients, were included in the final analysis. Eight studies compared bioimpedance with a gold standard, and two of those reported the results adequate. We found a low mean difference, but the 95% limits of agreements had wide limits. The remaining studies applied different surrogates as reference tests. Correlations ranged from 0.05 to 0.99. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) certainty of evidence for all outcomes was very low. Conclusions The accuracy of bioimpedance as a measure for fluids in critically ill patients in the intensive care unit cannot be determined. Due to the lack of a gold standard, numerous studies compared bioimpedance with surrogate outcomes with great variability in both designs and results. Assessing the internal reproducibility of bioimpedance had the same limitations, but the studies overall reported good internal reproducibility.</description><subject>bioelectrical impedance</subject><subject>body fluid</subject><subject>critical illness</subject><subject>Hospitals</subject><subject>Intensive care</subject><subject>intensive care unit</subject><subject>Intensive care units</subject><subject>organism hydration status</subject><subject>Quality</subject><subject>Reproducibility</subject><subject>Systematic review</subject><issn>0001-5172</issn><issn>1399-6576</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp10E1LxDAQBuAgCq6rB_9BwIse6qZJ02691cUvWPDgXjyVaTKFLOmHSevSf2-0ngRzGRKemQkvIZcxu43DWQH421jkPDkii1DzKJVZekwWjLE4knHGT8mZ9_twFUmeL8j7velM06OGViEFT4E2CH50SLua1nY0mvoBhtFT01LlzGAUWDtRYy3tYTDYDv6OFtRPfsAmPCjq8NPg4Zyc1GA9XvzWJdk9Puw2z9H29ellU2wjJQRLohqYiiXXEjmTGa9EGkOVCS4rxTLUeYbAhVYMdM44sFxWTK-TJK21lHmSiiW5nsf2rvsY0Q9lY7xCa6HFbvQll4JzuU5SHujVH7rvRteGzwWVJSws4FlQN7NSrvPeYV32zjTgpjJm5XfGZci4_Mk42NVsD8bi9D8si-Jt7vgCJEN8gw</recordid><startdate>202110</startdate><enddate>202110</enddate><creator>Madsen, Janne M.</creator><creator>Wichmann, Sine</creator><creator>Bestle, Morten H.</creator><creator>Itenov, Theis S.</creator><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7T5</scope><scope>7TK</scope><scope>H94</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0360-8655</orcidid><orcidid>https://orcid.org/0000-0002-2356-7355</orcidid></search><sort><creationdate>202110</creationdate><title>Bioimpedance as a measure of fluid status in critically ill patients: A systematic review</title><author>Madsen, Janne M. ; Wichmann, Sine ; Bestle, Morten H. ; Itenov, Theis S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3304-fa0c152d5e20572b361ab7325bc07ed97ea23dc0ad902a095b0d8446fd559463</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>bioelectrical impedance</topic><topic>body fluid</topic><topic>critical illness</topic><topic>Hospitals</topic><topic>Intensive care</topic><topic>intensive care unit</topic><topic>Intensive care units</topic><topic>organism hydration status</topic><topic>Quality</topic><topic>Reproducibility</topic><topic>Systematic review</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Madsen, Janne M.</creatorcontrib><creatorcontrib>Wichmann, Sine</creatorcontrib><creatorcontrib>Bestle, Morten H.</creatorcontrib><creatorcontrib>Itenov, Theis S.</creatorcontrib><collection>CrossRef</collection><collection>Immunology Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Acta anaesthesiologica Scandinavica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Madsen, Janne M.</au><au>Wichmann, Sine</au><au>Bestle, Morten H.</au><au>Itenov, Theis S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bioimpedance as a measure of fluid status in critically ill patients: A systematic review</atitle><jtitle>Acta anaesthesiologica Scandinavica</jtitle><date>2021-10</date><risdate>2021</risdate><volume>65</volume><issue>9</issue><spage>1155</spage><epage>1167</epage><pages>1155-1167</pages><issn>0001-5172</issn><eissn>1399-6576</eissn><abstract>Objective Precise measurements of fluid status lack valid methods. Bioimpedance is an attractive diagnostic tool because it is noninvasive, quick, and relatively cheap. This systematic review aims to assess the existing evidence of bioimpedance as an accurate measure of fluid status in critically ill patients. Data sources PubMed and Embase up till March 2021 were systematically searched (PROSPERO: CRD42020157436). Study selection Eligibility criteria were studies reporting original data from cohorts of adult patients in intensive care units and doing at least one whole‐body bioimpedance and one reference test. In addition, studies assessing internal reproducibility were included. Data extraction An extraction form was designed for the purpose. Data synthesis Nine hundred five studies were screened for eligibility, and 28 studies, comprising 1482 individual patients, were included in the final analysis. Eight studies compared bioimpedance with a gold standard, and two of those reported the results adequate. We found a low mean difference, but the 95% limits of agreements had wide limits. The remaining studies applied different surrogates as reference tests. Correlations ranged from 0.05 to 0.99. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) certainty of evidence for all outcomes was very low. Conclusions The accuracy of bioimpedance as a measure for fluids in critically ill patients in the intensive care unit cannot be determined. Due to the lack of a gold standard, numerous studies compared bioimpedance with surrogate outcomes with great variability in both designs and results. Assessing the internal reproducibility of bioimpedance had the same limitations, but the studies overall reported good internal reproducibility.</abstract><cop>Copenhagen</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1111/aas.13924</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0003-0360-8655</orcidid><orcidid>https://orcid.org/0000-0002-2356-7355</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0001-5172
ispartof Acta anaesthesiologica Scandinavica, 2021-10, Vol.65 (9), p.1155-1167
issn 0001-5172
1399-6576
language eng
recordid cdi_proquest_miscellaneous_2532258462
source Wiley Online Library All Journals
subjects bioelectrical impedance
body fluid
critical illness
Hospitals
Intensive care
intensive care unit
Intensive care units
organism hydration status
Quality
Reproducibility
Systematic review
title Bioimpedance as a measure of fluid status in critically ill patients: A systematic review
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T07%3A12%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bioimpedance%20as%20a%20measure%20of%20fluid%20status%20in%20critically%20ill%20patients:%20A%20systematic%20review&rft.jtitle=Acta%20anaesthesiologica%20Scandinavica&rft.au=Madsen,%20Janne%20M.&rft.date=2021-10&rft.volume=65&rft.issue=9&rft.spage=1155&rft.epage=1167&rft.pages=1155-1167&rft.issn=0001-5172&rft.eissn=1399-6576&rft_id=info:doi/10.1111/aas.13924&rft_dat=%3Cproquest_cross%3E2574090227%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2574090227&rft_id=info:pmid/&rfr_iscdi=true