On-line Analyzer for Ni–Zn Alloy Electroplated Coating on Steel
The Ni–Zn electroplated steel sheet is used as a car body material because of its high corrosion resistance. On production of this sheet, the coating weight and Ni content of the alloy coating are necessary to be controlled to ensure the quality of the products. An on-line X-ray fluorescence analyze...
Gespeichert in:
Veröffentlicht in: | ISIJ International 1989/10/15, Vol.29(10), pp.894-901 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 901 |
---|---|
container_issue | 10 |
container_start_page | 894 |
container_title | ISIJ International |
container_volume | 29 |
creator | Matsumoto, Yoshiro Fujino, Nobukatsu Shibuya, Atsuyoshi Nakahara, Hideyoku Nakase, Ikuo Koizumi, Akihiro |
description | The Ni–Zn electroplated steel sheet is used as a car body material because of its high corrosion resistance. On production of this sheet, the coating weight and Ni content of the alloy coating are necessary to be controlled to ensure the quality of the products. An on-line X-ray fluorescence analyzer has been developed for the determination of the coating weight and Ni content of the alloy coating. The features of the analyzer are summarized as follows: (1) The analysis is carried out full automatically. (2) X-ray intensities are measured by a detector (ionization chamber) with an Fe filter and the other with a Ni filter. The coating weight and the Ni content are calculated from the intensities measured by the two detectors. (3) This analyzer has been operated for seven years without any trouble. |
doi_str_mv | 10.2355/isijinternational.29.894 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_25318513</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>25318513</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3734-2c8f744b9c6ddd7af85f5a6288aabb39bfc976d18d5aae9b20ac7dd148a153b13</originalsourceid><addsrcrecordid>eNplkL1OwzAUhS0EElXpO3hiS4ljO7HHqio_UkWHwsJi3ThOceXaxU6HMvEOvCFPQkpRly73LN93rnQQwiQfF5TzO5vs2vrORA-dDR7cuJBjIdkFGhDKqoyzMr9Eg1wSnhHO5TUapWTrPC-YYJTQAZosfOasN3jS2_tPE3EbIn62P1_fbx5PnAt7PHNGdzFsHXSmwdPQ__IrHDxedsa4G3TVgktm9J9D9Ho_e5k-ZvPFw9N0Ms80rSjLCi3airFa6rJpmgpawVsOZSEEQF1TWbdaVmVDRMMBjKyLHHTVNIQJIJzWhA7R7bF3G8PHzqRObWzSxjnwJuySKjglghPag-II6hhSiqZV22g3EPeK5OowmzqbTRVS9bP16vKorlMHK3MSIXZWO3MuEinkQT40_92-5UTrd4jKePoL1quGew</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>25318513</pqid></control><display><type>article</type><title>On-line Analyzer for Ni–Zn Alloy Electroplated Coating on Steel</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Matsumoto, Yoshiro ; Fujino, Nobukatsu ; Shibuya, Atsuyoshi ; Nakahara, Hideyoku ; Nakase, Ikuo ; Koizumi, Akihiro</creator><creatorcontrib>Matsumoto, Yoshiro ; Fujino, Nobukatsu ; Shibuya, Atsuyoshi ; Nakahara, Hideyoku ; Nakase, Ikuo ; Koizumi, Akihiro</creatorcontrib><description>The Ni–Zn electroplated steel sheet is used as a car body material because of its high corrosion resistance. On production of this sheet, the coating weight and Ni content of the alloy coating are necessary to be controlled to ensure the quality of the products. An on-line X-ray fluorescence analyzer has been developed for the determination of the coating weight and Ni content of the alloy coating. The features of the analyzer are summarized as follows: (1) The analysis is carried out full automatically. (2) X-ray intensities are measured by a detector (ionization chamber) with an Fe filter and the other with a Ni filter. The coating weight and the Ni content are calculated from the intensities measured by the two detectors. (3) This analyzer has been operated for seven years without any trouble.</description><identifier>ISSN: 0915-1559</identifier><identifier>EISSN: 1347-5460</identifier><identifier>DOI: 10.2355/isijinternational.29.894</identifier><language>eng</language><publisher>The Iron and Steel Institute of Japan</publisher><subject>coating weight ; composition ; electroplating ; Ni–Zn alloy coating ; on-line analysis ; X-ray fluorescence</subject><ispartof>ISIJ International, 1989/10/15, Vol.29(10), pp.894-901</ispartof><rights>The Iron and Steel Institute of Japan</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1881,27922,27923</link.rule.ids></links><search><creatorcontrib>Matsumoto, Yoshiro</creatorcontrib><creatorcontrib>Fujino, Nobukatsu</creatorcontrib><creatorcontrib>Shibuya, Atsuyoshi</creatorcontrib><creatorcontrib>Nakahara, Hideyoku</creatorcontrib><creatorcontrib>Nakase, Ikuo</creatorcontrib><creatorcontrib>Koizumi, Akihiro</creatorcontrib><title>On-line Analyzer for Ni–Zn Alloy Electroplated Coating on Steel</title><title>ISIJ International</title><addtitle>ISIJ Int.</addtitle><description>The Ni–Zn electroplated steel sheet is used as a car body material because of its high corrosion resistance. On production of this sheet, the coating weight and Ni content of the alloy coating are necessary to be controlled to ensure the quality of the products. An on-line X-ray fluorescence analyzer has been developed for the determination of the coating weight and Ni content of the alloy coating. The features of the analyzer are summarized as follows: (1) The analysis is carried out full automatically. (2) X-ray intensities are measured by a detector (ionization chamber) with an Fe filter and the other with a Ni filter. The coating weight and the Ni content are calculated from the intensities measured by the two detectors. (3) This analyzer has been operated for seven years without any trouble.</description><subject>coating weight</subject><subject>composition</subject><subject>electroplating</subject><subject>Ni–Zn alloy coating</subject><subject>on-line analysis</subject><subject>X-ray fluorescence</subject><issn>0915-1559</issn><issn>1347-5460</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><recordid>eNplkL1OwzAUhS0EElXpO3hiS4ljO7HHqio_UkWHwsJi3ThOceXaxU6HMvEOvCFPQkpRly73LN93rnQQwiQfF5TzO5vs2vrORA-dDR7cuJBjIdkFGhDKqoyzMr9Eg1wSnhHO5TUapWTrPC-YYJTQAZosfOasN3jS2_tPE3EbIn62P1_fbx5PnAt7PHNGdzFsHXSmwdPQ__IrHDxedsa4G3TVgktm9J9D9Ho_e5k-ZvPFw9N0Ms80rSjLCi3airFa6rJpmgpawVsOZSEEQF1TWbdaVmVDRMMBjKyLHHTVNIQJIJzWhA7R7bF3G8PHzqRObWzSxjnwJuySKjglghPag-II6hhSiqZV22g3EPeK5OowmzqbTRVS9bP16vKorlMHK3MSIXZWO3MuEinkQT40_92-5UTrd4jKePoL1quGew</recordid><startdate>19890101</startdate><enddate>19890101</enddate><creator>Matsumoto, Yoshiro</creator><creator>Fujino, Nobukatsu</creator><creator>Shibuya, Atsuyoshi</creator><creator>Nakahara, Hideyoku</creator><creator>Nakase, Ikuo</creator><creator>Koizumi, Akihiro</creator><general>The Iron and Steel Institute of Japan</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope></search><sort><creationdate>19890101</creationdate><title>On-line Analyzer for Ni–Zn Alloy Electroplated Coating on Steel</title><author>Matsumoto, Yoshiro ; Fujino, Nobukatsu ; Shibuya, Atsuyoshi ; Nakahara, Hideyoku ; Nakase, Ikuo ; Koizumi, Akihiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3734-2c8f744b9c6ddd7af85f5a6288aabb39bfc976d18d5aae9b20ac7dd148a153b13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>coating weight</topic><topic>composition</topic><topic>electroplating</topic><topic>Ni–Zn alloy coating</topic><topic>on-line analysis</topic><topic>X-ray fluorescence</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Matsumoto, Yoshiro</creatorcontrib><creatorcontrib>Fujino, Nobukatsu</creatorcontrib><creatorcontrib>Shibuya, Atsuyoshi</creatorcontrib><creatorcontrib>Nakahara, Hideyoku</creatorcontrib><creatorcontrib>Nakase, Ikuo</creatorcontrib><creatorcontrib>Koizumi, Akihiro</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><jtitle>ISIJ International</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Matsumoto, Yoshiro</au><au>Fujino, Nobukatsu</au><au>Shibuya, Atsuyoshi</au><au>Nakahara, Hideyoku</au><au>Nakase, Ikuo</au><au>Koizumi, Akihiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On-line Analyzer for Ni–Zn Alloy Electroplated Coating on Steel</atitle><jtitle>ISIJ International</jtitle><addtitle>ISIJ Int.</addtitle><date>1989-01-01</date><risdate>1989</risdate><volume>29</volume><issue>10</issue><spage>894</spage><epage>901</epage><pages>894-901</pages><issn>0915-1559</issn><eissn>1347-5460</eissn><abstract>The Ni–Zn electroplated steel sheet is used as a car body material because of its high corrosion resistance. On production of this sheet, the coating weight and Ni content of the alloy coating are necessary to be controlled to ensure the quality of the products. An on-line X-ray fluorescence analyzer has been developed for the determination of the coating weight and Ni content of the alloy coating. The features of the analyzer are summarized as follows: (1) The analysis is carried out full automatically. (2) X-ray intensities are measured by a detector (ionization chamber) with an Fe filter and the other with a Ni filter. The coating weight and the Ni content are calculated from the intensities measured by the two detectors. (3) This analyzer has been operated for seven years without any trouble.</abstract><pub>The Iron and Steel Institute of Japan</pub><doi>10.2355/isijinternational.29.894</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0915-1559 |
ispartof | ISIJ International, 1989/10/15, Vol.29(10), pp.894-901 |
issn | 0915-1559 1347-5460 |
language | eng |
recordid | cdi_proquest_miscellaneous_25318513 |
source | J-STAGE Free; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry |
subjects | coating weight composition electroplating Ni–Zn alloy coating on-line analysis X-ray fluorescence |
title | On-line Analyzer for Ni–Zn Alloy Electroplated Coating on Steel |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T22%3A43%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On-line%20Analyzer%20for%20Ni%E2%80%93Zn%20Alloy%20Electroplated%20Coating%20on%20Steel&rft.jtitle=ISIJ%20International&rft.au=Matsumoto,%20Yoshiro&rft.date=1989-01-01&rft.volume=29&rft.issue=10&rft.spage=894&rft.epage=901&rft.pages=894-901&rft.issn=0915-1559&rft.eissn=1347-5460&rft_id=info:doi/10.2355/isijinternational.29.894&rft_dat=%3Cproquest_cross%3E25318513%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=25318513&rft_id=info:pmid/&rfr_iscdi=true |