Microfluidic measurement of individual cell membrane water permeability

This paper reports a microfluidic lab-on-chip for dynamic particle sizing and real time individual cell membrane permeability measurements. To achieve this, the device measures the impedance change of individual cells or particles at up to ten time points after mixing with different media, e.g. dime...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2021-06, Vol.1163, p.338441-338441, Article 338441
Hauptverfasser: Huang, Lining, Benson, James D., Almasri, Mahmoud
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 338441
container_issue
container_start_page 338441
container_title Analytica chimica acta
container_volume 1163
creator Huang, Lining
Benson, James D.
Almasri, Mahmoud
description This paper reports a microfluidic lab-on-chip for dynamic particle sizing and real time individual cell membrane permeability measurements. To achieve this, the device measures the impedance change of individual cells or particles at up to ten time points after mixing with different media, e.g. dimethyl sulfoxide or DI water, from separate inlets. These measurements are enabled by ten gold electrode pairs spread across a 20 mm long microchannel. The device measures impedance values within 0.26 s after mixing with other media, has a detection throughput of 150 samples/second, measures impedance values at all ten electrodes at this rate, and allows tracking of individual cell volume changes caused by cell osmosis in anisosmotic fluids over a 1.3 s postmixing timespan, facilitating accurate individual cell estimates of water permeability. The design and testing were performed using yeast cells (Saccharomyces cerevisiae). The relationship between volume and impedance in both polystyrene calibration beads as well as the volume-osmolality relationship in yeast were demonstrated. Moreover, we present the first noninvasive and non-optically-based water permeability measurements in individual cells. [Display omitted] •We calibrated and validated lab-on-chip dynamic cell sizing and cell membrane permeability measurements in individual cells.•Volume-correlated impedance change of myriad individual yeast cells was rapidly measured after mixing with anisosmotic media.•Measurements were performed within 0.26 s after mixing with media from separate inlets at up to 10 electrodes over 1.3 s.
doi_str_mv 10.1016/j.aca.2021.338441
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2531542256</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267021002671</els_id><sourcerecordid>2531542256</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-139d5af266f12d00e173b21e505aa4b72095246de16f1f0c252a86286d3b300f3</originalsourceid><addsrcrecordid>eNp9kM1OwzAQhC0EEqXwANxy5JKw_k0qTqiCglTEBc6WY68lV0lT7KSIt8dVOHNarXa-1cwQckuhokDV_a4y1lQMGK04b4SgZ2RBm5qXgjNxThYAwEumargkVynt8sooiAXZvAUbB99NwQVb9GjSFLHH_VgMvgh7F47BTaYrLHZdPvdtNHssvs2IsThgzEAbujD-XJMLb7qEN39zST6fnz7WL-X2ffO6ftyWlnMYS8pXThrPlPKUOQCkNW8ZRQnSGNHWDFaSCeWQZoEHyyQzjWKNcrzlAJ4vyd389xCHrwnTqPuQTuayrWFKmklOpWBMqiylszQHTCmi14cYehN_NAV9Kk3vdC5Nn0rTc2mZeZgZzBmOAaNONuDeogsR7ajdEP6hfwHEh3O2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2531542256</pqid></control><display><type>article</type><title>Microfluidic measurement of individual cell membrane water permeability</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Huang, Lining ; Benson, James D. ; Almasri, Mahmoud</creator><creatorcontrib>Huang, Lining ; Benson, James D. ; Almasri, Mahmoud</creatorcontrib><description>This paper reports a microfluidic lab-on-chip for dynamic particle sizing and real time individual cell membrane permeability measurements. To achieve this, the device measures the impedance change of individual cells or particles at up to ten time points after mixing with different media, e.g. dimethyl sulfoxide or DI water, from separate inlets. These measurements are enabled by ten gold electrode pairs spread across a 20 mm long microchannel. The device measures impedance values within 0.26 s after mixing with other media, has a detection throughput of 150 samples/second, measures impedance values at all ten electrodes at this rate, and allows tracking of individual cell volume changes caused by cell osmosis in anisosmotic fluids over a 1.3 s postmixing timespan, facilitating accurate individual cell estimates of water permeability. The design and testing were performed using yeast cells (Saccharomyces cerevisiae). The relationship between volume and impedance in both polystyrene calibration beads as well as the volume-osmolality relationship in yeast were demonstrated. Moreover, we present the first noninvasive and non-optically-based water permeability measurements in individual cells. [Display omitted] •We calibrated and validated lab-on-chip dynamic cell sizing and cell membrane permeability measurements in individual cells.•Volume-correlated impedance change of myriad individual yeast cells was rapidly measured after mixing with anisosmotic media.•Measurements were performed within 0.26 s after mixing with media from separate inlets at up to 10 electrodes over 1.3 s.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2021.338441</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Boyle van’t hoff ; Coulter counter ; Impedance measurement ; Individual cell membrane permeability ; Lab on a chip ; Microfluidic ; Water permeability ; Yeast cell</subject><ispartof>Analytica chimica acta, 2021-06, Vol.1163, p.338441-338441, Article 338441</ispartof><rights>2021 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-139d5af266f12d00e173b21e505aa4b72095246de16f1f0c252a86286d3b300f3</citedby><cites>FETCH-LOGICAL-c330t-139d5af266f12d00e173b21e505aa4b72095246de16f1f0c252a86286d3b300f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.aca.2021.338441$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Huang, Lining</creatorcontrib><creatorcontrib>Benson, James D.</creatorcontrib><creatorcontrib>Almasri, Mahmoud</creatorcontrib><title>Microfluidic measurement of individual cell membrane water permeability</title><title>Analytica chimica acta</title><description>This paper reports a microfluidic lab-on-chip for dynamic particle sizing and real time individual cell membrane permeability measurements. To achieve this, the device measures the impedance change of individual cells or particles at up to ten time points after mixing with different media, e.g. dimethyl sulfoxide or DI water, from separate inlets. These measurements are enabled by ten gold electrode pairs spread across a 20 mm long microchannel. The device measures impedance values within 0.26 s after mixing with other media, has a detection throughput of 150 samples/second, measures impedance values at all ten electrodes at this rate, and allows tracking of individual cell volume changes caused by cell osmosis in anisosmotic fluids over a 1.3 s postmixing timespan, facilitating accurate individual cell estimates of water permeability. The design and testing were performed using yeast cells (Saccharomyces cerevisiae). The relationship between volume and impedance in both polystyrene calibration beads as well as the volume-osmolality relationship in yeast were demonstrated. Moreover, we present the first noninvasive and non-optically-based water permeability measurements in individual cells. [Display omitted] •We calibrated and validated lab-on-chip dynamic cell sizing and cell membrane permeability measurements in individual cells.•Volume-correlated impedance change of myriad individual yeast cells was rapidly measured after mixing with anisosmotic media.•Measurements were performed within 0.26 s after mixing with media from separate inlets at up to 10 electrodes over 1.3 s.</description><subject>Boyle van’t hoff</subject><subject>Coulter counter</subject><subject>Impedance measurement</subject><subject>Individual cell membrane permeability</subject><subject>Lab on a chip</subject><subject>Microfluidic</subject><subject>Water permeability</subject><subject>Yeast cell</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kM1OwzAQhC0EEqXwANxy5JKw_k0qTqiCglTEBc6WY68lV0lT7KSIt8dVOHNarXa-1cwQckuhokDV_a4y1lQMGK04b4SgZ2RBm5qXgjNxThYAwEumargkVynt8sooiAXZvAUbB99NwQVb9GjSFLHH_VgMvgh7F47BTaYrLHZdPvdtNHssvs2IsThgzEAbujD-XJMLb7qEN39zST6fnz7WL-X2ffO6ftyWlnMYS8pXThrPlPKUOQCkNW8ZRQnSGNHWDFaSCeWQZoEHyyQzjWKNcrzlAJ4vyd389xCHrwnTqPuQTuayrWFKmklOpWBMqiylszQHTCmi14cYehN_NAV9Kk3vdC5Nn0rTc2mZeZgZzBmOAaNONuDeogsR7ajdEP6hfwHEh3O2</recordid><startdate>20210608</startdate><enddate>20210608</enddate><creator>Huang, Lining</creator><creator>Benson, James D.</creator><creator>Almasri, Mahmoud</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20210608</creationdate><title>Microfluidic measurement of individual cell membrane water permeability</title><author>Huang, Lining ; Benson, James D. ; Almasri, Mahmoud</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-139d5af266f12d00e173b21e505aa4b72095246de16f1f0c252a86286d3b300f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Boyle van’t hoff</topic><topic>Coulter counter</topic><topic>Impedance measurement</topic><topic>Individual cell membrane permeability</topic><topic>Lab on a chip</topic><topic>Microfluidic</topic><topic>Water permeability</topic><topic>Yeast cell</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huang, Lining</creatorcontrib><creatorcontrib>Benson, James D.</creatorcontrib><creatorcontrib>Almasri, Mahmoud</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, Lining</au><au>Benson, James D.</au><au>Almasri, Mahmoud</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microfluidic measurement of individual cell membrane water permeability</atitle><jtitle>Analytica chimica acta</jtitle><date>2021-06-08</date><risdate>2021</risdate><volume>1163</volume><spage>338441</spage><epage>338441</epage><pages>338441-338441</pages><artnum>338441</artnum><issn>0003-2670</issn><eissn>1873-4324</eissn><abstract>This paper reports a microfluidic lab-on-chip for dynamic particle sizing and real time individual cell membrane permeability measurements. To achieve this, the device measures the impedance change of individual cells or particles at up to ten time points after mixing with different media, e.g. dimethyl sulfoxide or DI water, from separate inlets. These measurements are enabled by ten gold electrode pairs spread across a 20 mm long microchannel. The device measures impedance values within 0.26 s after mixing with other media, has a detection throughput of 150 samples/second, measures impedance values at all ten electrodes at this rate, and allows tracking of individual cell volume changes caused by cell osmosis in anisosmotic fluids over a 1.3 s postmixing timespan, facilitating accurate individual cell estimates of water permeability. The design and testing were performed using yeast cells (Saccharomyces cerevisiae). The relationship between volume and impedance in both polystyrene calibration beads as well as the volume-osmolality relationship in yeast were demonstrated. Moreover, we present the first noninvasive and non-optically-based water permeability measurements in individual cells. [Display omitted] •We calibrated and validated lab-on-chip dynamic cell sizing and cell membrane permeability measurements in individual cells.•Volume-correlated impedance change of myriad individual yeast cells was rapidly measured after mixing with anisosmotic media.•Measurements were performed within 0.26 s after mixing with media from separate inlets at up to 10 electrodes over 1.3 s.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.aca.2021.338441</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2021-06, Vol.1163, p.338441-338441, Article 338441
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_2531542256
source Elsevier ScienceDirect Journals Complete
subjects Boyle van’t hoff
Coulter counter
Impedance measurement
Individual cell membrane permeability
Lab on a chip
Microfluidic
Water permeability
Yeast cell
title Microfluidic measurement of individual cell membrane water permeability
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T08%3A12%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microfluidic%20measurement%20of%20individual%20cell%20membrane%20water%20permeability&rft.jtitle=Analytica%20chimica%20acta&rft.au=Huang,%20Lining&rft.date=2021-06-08&rft.volume=1163&rft.spage=338441&rft.epage=338441&rft.pages=338441-338441&rft.artnum=338441&rft.issn=0003-2670&rft.eissn=1873-4324&rft_id=info:doi/10.1016/j.aca.2021.338441&rft_dat=%3Cproquest_cross%3E2531542256%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2531542256&rft_id=info:pmid/&rft_els_id=S0003267021002671&rfr_iscdi=true