Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics
In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simul...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2021-03, Vol.92 (3), p.033502-033502 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 033502 |
---|---|
container_issue | 3 |
container_start_page | 033502 |
container_title | Review of scientific instruments |
container_volume | 92 |
creator | Fraenkel, M. Ehrlich, Y. Shpilman, Z. Henis, Z. Frank, Y. Marley, E. V. Pérez-Callejo, G. Emig, J. Heeter, R. F. Liedahl, D. A. Foord, M. E. Schneider, M. B. |
description | In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments. |
doi_str_mv | 10.1063/5.0040574 |
format | Article |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_proquest_miscellaneous_2509272606</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2494674886</sourcerecordid><originalsourceid>FETCH-LOGICAL-c445t-f3070fa269bc17ac43512fed27496268e96f0c9770b6816c62eea6465d52ea383</originalsourceid><addsrcrecordid>eNp9kc1u1DAUhS0EotOBBS-ALNi0SCn-d7KsSmmRBlgwbNhYHudmmmpiB9sB8RS8Mo5mClKl4o117e8e3-OD0AtKzihR_K08I0QQqcUjtKCkbiqtGH-MFoRwUSkt6iN0nNItKUtS-hQdcV6zUvAF-v0RbJoiDOAzDh1eVekGdjsMQ59SHzzuYhjw0LfVN5xt3EJOePItROyDr1brS-yCb_tc0HKRer_F62h9umu_ijbPh19GcLlIQS6t1rf43fmn0jyGn6Vue7v1IeXepWfoSWd3CZ4f9iX6-v5yfXFdrT5ffbg4X1VOCJmrjhNNOstUs3FUWye4pKyDlmnRKKZqaFRHXKM12aiaKqcYgFVCyVYysLzmS_Rqrzs_a5LrM7ibYsWXMQ3VqlaKFOhkD40xfJ8gZVNsufI91kOYkmGSNEwzVTJYotf30NswRV8sGCYaMYdQz9TpnnIxpBShM2PsBxt_GUrMHKWR5hBlYV8eFKfNAO1f8i67ArzZA_P0dk7gv2oPwj9C_Aease34HyWstG8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2494674886</pqid></control><display><type>article</type><title>Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Fraenkel, M. ; Ehrlich, Y. ; Shpilman, Z. ; Henis, Z. ; Frank, Y. ; Marley, E. V. ; Pérez-Callejo, G. ; Emig, J. ; Heeter, R. F. ; Liedahl, D. A. ; Foord, M. E. ; Schneider, M. B.</creator><creatorcontrib>Fraenkel, M. ; Ehrlich, Y. ; Shpilman, Z. ; Henis, Z. ; Frank, Y. ; Marley, E. V. ; Pérez-Callejo, G. ; Emig, J. ; Heeter, R. F. ; Liedahl, D. A. ; Foord, M. E. ; Schneider, M. B.</creatorcontrib><description>In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0040574</identifier><identifier>PMID: 33820003</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Astrophysics ; Atomic physics ; Broadband ; Diagnostic systems ; Emission ; Experiments ; Flux density ; Inertial confinement fusion ; Local thermodynamic equilibrium ; Plasmas (physics) ; Scientific apparatus & instruments ; Spectra ; Spectral resolution</subject><ispartof>Review of scientific instruments, 2021-03, Vol.92 (3), p.033502-033502</ispartof><rights>Author(s)</rights><rights>2021 Author(s). Published under license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c445t-f3070fa269bc17ac43512fed27496268e96f0c9770b6816c62eea6465d52ea383</citedby><cites>FETCH-LOGICAL-c445t-f3070fa269bc17ac43512fed27496268e96f0c9770b6816c62eea6465d52ea383</cites><orcidid>0000-0003-3719-2352 ; 0000-0003-3674-1049 ; 0000-0002-9193-9544 ; 0000-0003-1097-1823 ; 0000-0001-9706-8308 ; 0000000337192352 ; 0000000336741049 ; 0000000310971823 ; 0000000197068308 ; 0000000291939544</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0040574$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>230,315,781,785,795,886,4513,27926,27927,76386</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33820003$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/1768660$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Fraenkel, M.</creatorcontrib><creatorcontrib>Ehrlich, Y.</creatorcontrib><creatorcontrib>Shpilman, Z.</creatorcontrib><creatorcontrib>Henis, Z.</creatorcontrib><creatorcontrib>Frank, Y.</creatorcontrib><creatorcontrib>Marley, E. V.</creatorcontrib><creatorcontrib>Pérez-Callejo, G.</creatorcontrib><creatorcontrib>Emig, J.</creatorcontrib><creatorcontrib>Heeter, R. F.</creatorcontrib><creatorcontrib>Liedahl, D. A.</creatorcontrib><creatorcontrib>Foord, M. E.</creatorcontrib><creatorcontrib>Schneider, M. B.</creatorcontrib><title>Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.</description><subject>Astrophysics</subject><subject>Atomic physics</subject><subject>Broadband</subject><subject>Diagnostic systems</subject><subject>Emission</subject><subject>Experiments</subject><subject>Flux density</subject><subject>Inertial confinement fusion</subject><subject>Local thermodynamic equilibrium</subject><subject>Plasmas (physics)</subject><subject>Scientific apparatus & instruments</subject><subject>Spectra</subject><subject>Spectral resolution</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1DAUhS0EotOBBS-ALNi0SCn-d7KsSmmRBlgwbNhYHudmmmpiB9sB8RS8Mo5mClKl4o117e8e3-OD0AtKzihR_K08I0QQqcUjtKCkbiqtGH-MFoRwUSkt6iN0nNItKUtS-hQdcV6zUvAF-v0RbJoiDOAzDh1eVekGdjsMQ59SHzzuYhjw0LfVN5xt3EJOePItROyDr1brS-yCb_tc0HKRer_F62h9umu_ijbPh19GcLlIQS6t1rf43fmn0jyGn6Vue7v1IeXepWfoSWd3CZ4f9iX6-v5yfXFdrT5ffbg4X1VOCJmrjhNNOstUs3FUWye4pKyDlmnRKKZqaFRHXKM12aiaKqcYgFVCyVYysLzmS_Rqrzs_a5LrM7ibYsWXMQ3VqlaKFOhkD40xfJ8gZVNsufI91kOYkmGSNEwzVTJYotf30NswRV8sGCYaMYdQz9TpnnIxpBShM2PsBxt_GUrMHKWR5hBlYV8eFKfNAO1f8i67ArzZA_P0dk7gv2oPwj9C_Aease34HyWstG8</recordid><startdate>20210301</startdate><enddate>20210301</enddate><creator>Fraenkel, M.</creator><creator>Ehrlich, Y.</creator><creator>Shpilman, Z.</creator><creator>Henis, Z.</creator><creator>Frank, Y.</creator><creator>Marley, E. V.</creator><creator>Pérez-Callejo, G.</creator><creator>Emig, J.</creator><creator>Heeter, R. F.</creator><creator>Liedahl, D. A.</creator><creator>Foord, M. E.</creator><creator>Schneider, M. B.</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><scope>OTOTI</scope><orcidid>https://orcid.org/0000-0003-3719-2352</orcidid><orcidid>https://orcid.org/0000-0003-3674-1049</orcidid><orcidid>https://orcid.org/0000-0002-9193-9544</orcidid><orcidid>https://orcid.org/0000-0003-1097-1823</orcidid><orcidid>https://orcid.org/0000-0001-9706-8308</orcidid><orcidid>https://orcid.org/0000000337192352</orcidid><orcidid>https://orcid.org/0000000336741049</orcidid><orcidid>https://orcid.org/0000000310971823</orcidid><orcidid>https://orcid.org/0000000197068308</orcidid><orcidid>https://orcid.org/0000000291939544</orcidid></search><sort><creationdate>20210301</creationdate><title>Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics</title><author>Fraenkel, M. ; Ehrlich, Y. ; Shpilman, Z. ; Henis, Z. ; Frank, Y. ; Marley, E. V. ; Pérez-Callejo, G. ; Emig, J. ; Heeter, R. F. ; Liedahl, D. A. ; Foord, M. E. ; Schneider, M. B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c445t-f3070fa269bc17ac43512fed27496268e96f0c9770b6816c62eea6465d52ea383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Astrophysics</topic><topic>Atomic physics</topic><topic>Broadband</topic><topic>Diagnostic systems</topic><topic>Emission</topic><topic>Experiments</topic><topic>Flux density</topic><topic>Inertial confinement fusion</topic><topic>Local thermodynamic equilibrium</topic><topic>Plasmas (physics)</topic><topic>Scientific apparatus & instruments</topic><topic>Spectra</topic><topic>Spectral resolution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fraenkel, M.</creatorcontrib><creatorcontrib>Ehrlich, Y.</creatorcontrib><creatorcontrib>Shpilman, Z.</creatorcontrib><creatorcontrib>Henis, Z.</creatorcontrib><creatorcontrib>Frank, Y.</creatorcontrib><creatorcontrib>Marley, E. V.</creatorcontrib><creatorcontrib>Pérez-Callejo, G.</creatorcontrib><creatorcontrib>Emig, J.</creatorcontrib><creatorcontrib>Heeter, R. F.</creatorcontrib><creatorcontrib>Liedahl, D. A.</creatorcontrib><creatorcontrib>Foord, M. E.</creatorcontrib><creatorcontrib>Schneider, M. B.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><collection>OSTI.GOV</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fraenkel, M.</au><au>Ehrlich, Y.</au><au>Shpilman, Z.</au><au>Henis, Z.</au><au>Frank, Y.</au><au>Marley, E. V.</au><au>Pérez-Callejo, G.</au><au>Emig, J.</au><au>Heeter, R. F.</au><au>Liedahl, D. A.</au><au>Foord, M. E.</au><au>Schneider, M. B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2021-03-01</date><risdate>2021</risdate><volume>92</volume><issue>3</issue><spage>033502</spage><epage>033502</epage><pages>033502-033502</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>33820003</pmid><doi>10.1063/5.0040574</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0003-3719-2352</orcidid><orcidid>https://orcid.org/0000-0003-3674-1049</orcidid><orcidid>https://orcid.org/0000-0002-9193-9544</orcidid><orcidid>https://orcid.org/0000-0003-1097-1823</orcidid><orcidid>https://orcid.org/0000-0001-9706-8308</orcidid><orcidid>https://orcid.org/0000000337192352</orcidid><orcidid>https://orcid.org/0000000336741049</orcidid><orcidid>https://orcid.org/0000000310971823</orcidid><orcidid>https://orcid.org/0000000197068308</orcidid><orcidid>https://orcid.org/0000000291939544</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2021-03, Vol.92 (3), p.033502-033502 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_proquest_miscellaneous_2509272606 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Astrophysics Atomic physics Broadband Diagnostic systems Emission Experiments Flux density Inertial confinement fusion Local thermodynamic equilibrium Plasmas (physics) Scientific apparatus & instruments Spectra Spectral resolution |
title | Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T07%3A43%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20L-shell%20emission%20from%20mid-Z%20targets%20under%20non-LTE%20conditions%20using%20Transmission%20Grating%20Spectrometer%20and%20DANTE%20power%20diagnostics&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Fraenkel,%20M.&rft.date=2021-03-01&rft.volume=92&rft.issue=3&rft.spage=033502&rft.epage=033502&rft.pages=033502-033502&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0040574&rft_dat=%3Cproquest_osti_%3E2494674886%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2494674886&rft_id=info:pmid/33820003&rfr_iscdi=true |