Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies

Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Current problems in diagnostic radiology 2021-09, Vol.50 (5), p.566-570
Hauptverfasser: Sammer, Marla B.K., Kan, J. Herman, Somcio, Ray, Sher, Andrew C., Hansen, Carly M., Pahlka, R. Benton, Guillerman, R. Paul, Seghers, Victor J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 570
container_issue 5
container_start_page 566
container_title Current problems in diagnostic radiology
container_volume 50
creator Sammer, Marla B.K.
Kan, J. Herman
Somcio, Ray
Sher, Andrew C.
Hansen, Carly M.
Pahlka, R. Benton
Guillerman, R. Paul
Seghers, Victor J.
description Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT has historically not been used in children given the typically higher radiation doses on CT compared with fluoroscopy. In distinction to an esophagram, CT does not require oral contrast nor presence of an onsite radiologist and can be interpreted remotely. At our institution, a dedicated CT protocol has been used for airway foreign bodies since 2015. Given the advantages of CT over esophagram, we retrospectively reviewed institutional radiation dose data from 2017 to 2020 for esophagrams, airway foreign body CT (FB-CT), and routine CT Chest to compare effective doses for each modality. For ages 1+ years, effective dose was lowest using the FB-CT protocol; esophagram mean dose showed the most variability, and was over double the dose of FB-CT for ages 5+ years. Routine CT chest doses were uniformly highest across all age ranges. Given these findings, we instituted a CT foreign body imaging protocol as the first-line imaging modality for radiolucent esophageal foreign body at our institution.
doi_str_mv 10.1067/j.cpradiol.2021.03.012
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2503679755</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0363018821000475</els_id><sourcerecordid>2503679755</sourcerecordid><originalsourceid>FETCH-LOGICAL-c434t-b5e49d79d1eb9bd6dfebae0763a9b48ca4736b1ba87e3799c7705fa8df70d1d93</originalsourceid><addsrcrecordid>eNqFkEFPwjAUxxujEUS_AunRy2a7but6EyeoCYke8Nx07RuUDIrtMPHbWwJ49fQuv__7v_dDaExJSknJH9ap3nllrOvSjGQ0JSwlNLtAQ1qwIikZyS7RkLCSJYRW1QDdhLAmkRCUX6MBYzwveCmGaFKvIPS4XuDWedyvAD9btdy6YAN2Lf4AY1XvrcbT4HYrtQTV4ZnzYJdb_OSMhXCLrlrVBbg7zRH6nE0X9Wsyf395qyfzROcs75OmgFwYLgyFRjSmNC00CggvmRJNXmmVc1Y2tFEVB8aF0JyTolWVaTkx1Ag2QvfHvTvvvvbxaLmxQUPXqS24fZBZEd_lghdFRMsjqr0LwUMrd95ulP-RlMiDPrmWZ33yoE8SJqOcGByfOvbNBsxf7OwrAo9HAOKn3xa8DNrCVkdNHnQvjbP_dfwCQgWEDw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2503679755</pqid></control><display><type>article</type><title>Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Sammer, Marla B.K. ; Kan, J. Herman ; Somcio, Ray ; Sher, Andrew C. ; Hansen, Carly M. ; Pahlka, R. Benton ; Guillerman, R. Paul ; Seghers, Victor J.</creator><creatorcontrib>Sammer, Marla B.K. ; Kan, J. Herman ; Somcio, Ray ; Sher, Andrew C. ; Hansen, Carly M. ; Pahlka, R. Benton ; Guillerman, R. Paul ; Seghers, Victor J.</creatorcontrib><description>Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT has historically not been used in children given the typically higher radiation doses on CT compared with fluoroscopy. In distinction to an esophagram, CT does not require oral contrast nor presence of an onsite radiologist and can be interpreted remotely. At our institution, a dedicated CT protocol has been used for airway foreign bodies since 2015. Given the advantages of CT over esophagram, we retrospectively reviewed institutional radiation dose data from 2017 to 2020 for esophagrams, airway foreign body CT (FB-CT), and routine CT Chest to compare effective doses for each modality. For ages 1+ years, effective dose was lowest using the FB-CT protocol; esophagram mean dose showed the most variability, and was over double the dose of FB-CT for ages 5+ years. Routine CT chest doses were uniformly highest across all age ranges. Given these findings, we instituted a CT foreign body imaging protocol as the first-line imaging modality for radiolucent esophageal foreign body at our institution.</description><identifier>ISSN: 0363-0188</identifier><identifier>EISSN: 1535-6302</identifier><identifier>DOI: 10.1067/j.cpradiol.2021.03.012</identifier><identifier>PMID: 33745769</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>Current problems in diagnostic radiology, 2021-09, Vol.50 (5), p.566-570</ispartof><rights>2021 Elsevier Inc.</rights><rights>Copyright © 2021 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c434t-b5e49d79d1eb9bd6dfebae0763a9b48ca4736b1ba87e3799c7705fa8df70d1d93</citedby><cites>FETCH-LOGICAL-c434t-b5e49d79d1eb9bd6dfebae0763a9b48ca4736b1ba87e3799c7705fa8df70d1d93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1067/j.cpradiol.2021.03.012$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33745769$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sammer, Marla B.K.</creatorcontrib><creatorcontrib>Kan, J. Herman</creatorcontrib><creatorcontrib>Somcio, Ray</creatorcontrib><creatorcontrib>Sher, Andrew C.</creatorcontrib><creatorcontrib>Hansen, Carly M.</creatorcontrib><creatorcontrib>Pahlka, R. Benton</creatorcontrib><creatorcontrib>Guillerman, R. Paul</creatorcontrib><creatorcontrib>Seghers, Victor J.</creatorcontrib><title>Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies</title><title>Current problems in diagnostic radiology</title><addtitle>Curr Probl Diagn Radiol</addtitle><description>Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT has historically not been used in children given the typically higher radiation doses on CT compared with fluoroscopy. In distinction to an esophagram, CT does not require oral contrast nor presence of an onsite radiologist and can be interpreted remotely. At our institution, a dedicated CT protocol has been used for airway foreign bodies since 2015. Given the advantages of CT over esophagram, we retrospectively reviewed institutional radiation dose data from 2017 to 2020 for esophagrams, airway foreign body CT (FB-CT), and routine CT Chest to compare effective doses for each modality. For ages 1+ years, effective dose was lowest using the FB-CT protocol; esophagram mean dose showed the most variability, and was over double the dose of FB-CT for ages 5+ years. Routine CT chest doses were uniformly highest across all age ranges. Given these findings, we instituted a CT foreign body imaging protocol as the first-line imaging modality for radiolucent esophageal foreign body at our institution.</description><issn>0363-0188</issn><issn>1535-6302</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqFkEFPwjAUxxujEUS_AunRy2a7but6EyeoCYke8Nx07RuUDIrtMPHbWwJ49fQuv__7v_dDaExJSknJH9ap3nllrOvSjGQ0JSwlNLtAQ1qwIikZyS7RkLCSJYRW1QDdhLAmkRCUX6MBYzwveCmGaFKvIPS4XuDWedyvAD9btdy6YAN2Lf4AY1XvrcbT4HYrtQTV4ZnzYJdb_OSMhXCLrlrVBbg7zRH6nE0X9Wsyf395qyfzROcs75OmgFwYLgyFRjSmNC00CggvmRJNXmmVc1Y2tFEVB8aF0JyTolWVaTkx1Ag2QvfHvTvvvvbxaLmxQUPXqS24fZBZEd_lghdFRMsjqr0LwUMrd95ulP-RlMiDPrmWZ33yoE8SJqOcGByfOvbNBsxf7OwrAo9HAOKn3xa8DNrCVkdNHnQvjbP_dfwCQgWEDw</recordid><startdate>20210901</startdate><enddate>20210901</enddate><creator>Sammer, Marla B.K.</creator><creator>Kan, J. Herman</creator><creator>Somcio, Ray</creator><creator>Sher, Andrew C.</creator><creator>Hansen, Carly M.</creator><creator>Pahlka, R. Benton</creator><creator>Guillerman, R. Paul</creator><creator>Seghers, Victor J.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20210901</creationdate><title>Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies</title><author>Sammer, Marla B.K. ; Kan, J. Herman ; Somcio, Ray ; Sher, Andrew C. ; Hansen, Carly M. ; Pahlka, R. Benton ; Guillerman, R. Paul ; Seghers, Victor J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c434t-b5e49d79d1eb9bd6dfebae0763a9b48ca4736b1ba87e3799c7705fa8df70d1d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sammer, Marla B.K.</creatorcontrib><creatorcontrib>Kan, J. Herman</creatorcontrib><creatorcontrib>Somcio, Ray</creatorcontrib><creatorcontrib>Sher, Andrew C.</creatorcontrib><creatorcontrib>Hansen, Carly M.</creatorcontrib><creatorcontrib>Pahlka, R. Benton</creatorcontrib><creatorcontrib>Guillerman, R. Paul</creatorcontrib><creatorcontrib>Seghers, Victor J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Current problems in diagnostic radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sammer, Marla B.K.</au><au>Kan, J. Herman</au><au>Somcio, Ray</au><au>Sher, Andrew C.</au><au>Hansen, Carly M.</au><au>Pahlka, R. Benton</au><au>Guillerman, R. Paul</au><au>Seghers, Victor J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies</atitle><jtitle>Current problems in diagnostic radiology</jtitle><addtitle>Curr Probl Diagn Radiol</addtitle><date>2021-09-01</date><risdate>2021</risdate><volume>50</volume><issue>5</issue><spage>566</spage><epage>570</epage><pages>566-570</pages><issn>0363-0188</issn><eissn>1535-6302</eissn><abstract>Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT has historically not been used in children given the typically higher radiation doses on CT compared with fluoroscopy. In distinction to an esophagram, CT does not require oral contrast nor presence of an onsite radiologist and can be interpreted remotely. At our institution, a dedicated CT protocol has been used for airway foreign bodies since 2015. Given the advantages of CT over esophagram, we retrospectively reviewed institutional radiation dose data from 2017 to 2020 for esophagrams, airway foreign body CT (FB-CT), and routine CT Chest to compare effective doses for each modality. For ages 1+ years, effective dose was lowest using the FB-CT protocol; esophagram mean dose showed the most variability, and was over double the dose of FB-CT for ages 5+ years. Routine CT chest doses were uniformly highest across all age ranges. Given these findings, we instituted a CT foreign body imaging protocol as the first-line imaging modality for radiolucent esophageal foreign body at our institution.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>33745769</pmid><doi>10.1067/j.cpradiol.2021.03.012</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0363-0188
ispartof Current problems in diagnostic radiology, 2021-09, Vol.50 (5), p.566-570
issn 0363-0188
1535-6302
language eng
recordid cdi_proquest_miscellaneous_2503679755
source Elsevier ScienceDirect Journals Complete
title Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T02%3A55%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Chest%20CT%20for%20the%20Diagnosis%20of%20Pediatric%20Esophageal%20Foreign%20Bodies&rft.jtitle=Current%20problems%20in%20diagnostic%20radiology&rft.au=Sammer,%20Marla%20B.K.&rft.date=2021-09-01&rft.volume=50&rft.issue=5&rft.spage=566&rft.epage=570&rft.pages=566-570&rft.issn=0363-0188&rft.eissn=1535-6302&rft_id=info:doi/10.1067/j.cpradiol.2021.03.012&rft_dat=%3Cproquest_cross%3E2503679755%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2503679755&rft_id=info:pmid/33745769&rft_els_id=S0363018821000475&rfr_iscdi=true