Transapical off‐pump mitral valve repair with NeoChord implantation: A systematic review

Introduction Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising out...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiac surgery 2021-04, Vol.36 (4), p.1492-1498
Hauptverfasser: Ahmed, Ahmed, Abdel‐Aziz, Tarek A., AlAsaad, Mohannad M. R., Majthoob, Motaz
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1498
container_issue 4
container_start_page 1492
container_title Journal of cardiac surgery
container_volume 36
creator Ahmed, Ahmed
Abdel‐Aziz, Tarek A.
AlAsaad, Mohannad M. R.
Majthoob, Motaz
description Introduction Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising outcomes. This study aims to conduct a systematic review of the published literature that discusses the technical feasibility and outcome of transapical off‐pump MVr with NeoChord DS1000 device implantation in the treatment of degenerative MR. Methods This review was performed according to the PRISMA statement. Databases searched in this review included Pubmed, Web of Science, Scopus, and Cochrane databases for systematic reviews. All English articles on humans reporting isolated MVr using NeoChord DS1000 device were included provided that basic preoperative data, operative specifications, and postoperative mortality and morbidity were reported. Results This review included six studies comprised 249 patients who had NeoChord mitral procedure. Almost all patients included had severe MR (243/249, 97.6%). Operative success was achieved in 241 out of the 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia was reported in six patients (2.4%) and significant bleeding was reported in eight patients (3.2%). Conclusion Awaiting more evidence, NeoChord mitral procedure appears to be a promising procedure that can be considered in selected cases.
doi_str_mv 10.1111/jocs.15350
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2480279619</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2480279619</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3650-9f73838d4c1e62c5cc10c71f2752c6b6f678bce91b52fac661da699e47240d623</originalsourceid><addsrcrecordid>eNp9kLtOwzAUQC0EoqWw8AHII0JK8SuOw1ZFPFXRgbKwRI7jqK6SJthJq258At_Il-CSwoiXK18dHV0dAM4xGmP_rpe1cmMc0hAdgCEOGQoEjvEhGCIheIAYQwNw4twSIUIYRcdgQCmLOIvEELzNrVw52RglS1gXxdfHZ9NVDaxMa_1mLcu1hlY30li4Me0CPus6WdQ2h6ZqSrlqZWvq1Q2cQLd1ra78V3l-bfTmFBwVsnT6bD9H4PXudp48BNPZ_WMymQaK8hAFcRFRQUXOFNacqFApjFSECxKFRPGMFzwSmdIxzkJSSMU5ziWPY80iwlDOCR2By97b2Pq9065NK-OULv11uu5cSphAJIo5jj161aPK1s5ZXaSNNZW02xSjdNcy3bVMf1p6-GLv7bJK53_obzwP4B7YmFJv_1GlT7PkpZd-AwWagGE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2480279619</pqid></control><display><type>article</type><title>Transapical off‐pump mitral valve repair with NeoChord implantation: A systematic review</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>Ahmed, Ahmed ; Abdel‐Aziz, Tarek A. ; AlAsaad, Mohannad M. R. ; Majthoob, Motaz</creator><creatorcontrib>Ahmed, Ahmed ; Abdel‐Aziz, Tarek A. ; AlAsaad, Mohannad M. R. ; Majthoob, Motaz</creatorcontrib><description>Introduction Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising outcomes. This study aims to conduct a systematic review of the published literature that discusses the technical feasibility and outcome of transapical off‐pump MVr with NeoChord DS1000 device implantation in the treatment of degenerative MR. Methods This review was performed according to the PRISMA statement. Databases searched in this review included Pubmed, Web of Science, Scopus, and Cochrane databases for systematic reviews. All English articles on humans reporting isolated MVr using NeoChord DS1000 device were included provided that basic preoperative data, operative specifications, and postoperative mortality and morbidity were reported. Results This review included six studies comprised 249 patients who had NeoChord mitral procedure. Almost all patients included had severe MR (243/249, 97.6%). Operative success was achieved in 241 out of the 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia was reported in six patients (2.4%) and significant bleeding was reported in eight patients (3.2%). Conclusion Awaiting more evidence, NeoChord mitral procedure appears to be a promising procedure that can be considered in selected cases.</description><identifier>ISSN: 0886-0440</identifier><identifier>EISSN: 1540-8191</identifier><identifier>DOI: 10.1111/jocs.15350</identifier><identifier>PMID: 33476478</identifier><language>eng</language><publisher>United States</publisher><subject>Heart Valve Prosthesis Implantation ; Humans ; mitral regurgitation ; Mitral Valve - surgery ; Mitral Valve Insufficiency - surgery ; Mitral Valve Prolapse - surgery ; mitral valve repair ; NeoChord DS1000 ; Treatment Outcome</subject><ispartof>Journal of cardiac surgery, 2021-04, Vol.36 (4), p.1492-1498</ispartof><rights>2021 Wiley Periodicals LLC</rights><rights>2021 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3650-9f73838d4c1e62c5cc10c71f2752c6b6f678bce91b52fac661da699e47240d623</citedby><cites>FETCH-LOGICAL-c3650-9f73838d4c1e62c5cc10c71f2752c6b6f678bce91b52fac661da699e47240d623</cites><orcidid>0000-0003-4748-6282 ; 0000-0001-8502-9715</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fjocs.15350$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fjocs.15350$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33476478$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ahmed, Ahmed</creatorcontrib><creatorcontrib>Abdel‐Aziz, Tarek A.</creatorcontrib><creatorcontrib>AlAsaad, Mohannad M. R.</creatorcontrib><creatorcontrib>Majthoob, Motaz</creatorcontrib><title>Transapical off‐pump mitral valve repair with NeoChord implantation: A systematic review</title><title>Journal of cardiac surgery</title><addtitle>J Card Surg</addtitle><description>Introduction Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising outcomes. This study aims to conduct a systematic review of the published literature that discusses the technical feasibility and outcome of transapical off‐pump MVr with NeoChord DS1000 device implantation in the treatment of degenerative MR. Methods This review was performed according to the PRISMA statement. Databases searched in this review included Pubmed, Web of Science, Scopus, and Cochrane databases for systematic reviews. All English articles on humans reporting isolated MVr using NeoChord DS1000 device were included provided that basic preoperative data, operative specifications, and postoperative mortality and morbidity were reported. Results This review included six studies comprised 249 patients who had NeoChord mitral procedure. Almost all patients included had severe MR (243/249, 97.6%). Operative success was achieved in 241 out of the 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia was reported in six patients (2.4%) and significant bleeding was reported in eight patients (3.2%). Conclusion Awaiting more evidence, NeoChord mitral procedure appears to be a promising procedure that can be considered in selected cases.</description><subject>Heart Valve Prosthesis Implantation</subject><subject>Humans</subject><subject>mitral regurgitation</subject><subject>Mitral Valve - surgery</subject><subject>Mitral Valve Insufficiency - surgery</subject><subject>Mitral Valve Prolapse - surgery</subject><subject>mitral valve repair</subject><subject>NeoChord DS1000</subject><subject>Treatment Outcome</subject><issn>0886-0440</issn><issn>1540-8191</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kLtOwzAUQC0EoqWw8AHII0JK8SuOw1ZFPFXRgbKwRI7jqK6SJthJq258At_Il-CSwoiXK18dHV0dAM4xGmP_rpe1cmMc0hAdgCEOGQoEjvEhGCIheIAYQwNw4twSIUIYRcdgQCmLOIvEELzNrVw52RglS1gXxdfHZ9NVDaxMa_1mLcu1hlY30li4Me0CPus6WdQ2h6ZqSrlqZWvq1Q2cQLd1ra78V3l-bfTmFBwVsnT6bD9H4PXudp48BNPZ_WMymQaK8hAFcRFRQUXOFNacqFApjFSECxKFRPGMFzwSmdIxzkJSSMU5ziWPY80iwlDOCR2By97b2Pq9065NK-OULv11uu5cSphAJIo5jj161aPK1s5ZXaSNNZW02xSjdNcy3bVMf1p6-GLv7bJK53_obzwP4B7YmFJv_1GlT7PkpZd-AwWagGE</recordid><startdate>202104</startdate><enddate>202104</enddate><creator>Ahmed, Ahmed</creator><creator>Abdel‐Aziz, Tarek A.</creator><creator>AlAsaad, Mohannad M. R.</creator><creator>Majthoob, Motaz</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4748-6282</orcidid><orcidid>https://orcid.org/0000-0001-8502-9715</orcidid></search><sort><creationdate>202104</creationdate><title>Transapical off‐pump mitral valve repair with NeoChord implantation: A systematic review</title><author>Ahmed, Ahmed ; Abdel‐Aziz, Tarek A. ; AlAsaad, Mohannad M. R. ; Majthoob, Motaz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3650-9f73838d4c1e62c5cc10c71f2752c6b6f678bce91b52fac661da699e47240d623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Heart Valve Prosthesis Implantation</topic><topic>Humans</topic><topic>mitral regurgitation</topic><topic>Mitral Valve - surgery</topic><topic>Mitral Valve Insufficiency - surgery</topic><topic>Mitral Valve Prolapse - surgery</topic><topic>mitral valve repair</topic><topic>NeoChord DS1000</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ahmed, Ahmed</creatorcontrib><creatorcontrib>Abdel‐Aziz, Tarek A.</creatorcontrib><creatorcontrib>AlAsaad, Mohannad M. R.</creatorcontrib><creatorcontrib>Majthoob, Motaz</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of cardiac surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ahmed, Ahmed</au><au>Abdel‐Aziz, Tarek A.</au><au>AlAsaad, Mohannad M. R.</au><au>Majthoob, Motaz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transapical off‐pump mitral valve repair with NeoChord implantation: A systematic review</atitle><jtitle>Journal of cardiac surgery</jtitle><addtitle>J Card Surg</addtitle><date>2021-04</date><risdate>2021</risdate><volume>36</volume><issue>4</issue><spage>1492</spage><epage>1498</epage><pages>1492-1498</pages><issn>0886-0440</issn><eissn>1540-8191</eissn><abstract>Introduction Mitral valve repair (MVr) is the gold standard for the treatment of degenerative mitral valve regurgitation (MR). The recently introduced NeoChord DS1000 has gained increasing recognition as a feasible, potentially safe, and effective procedure with minor complications and promising outcomes. This study aims to conduct a systematic review of the published literature that discusses the technical feasibility and outcome of transapical off‐pump MVr with NeoChord DS1000 device implantation in the treatment of degenerative MR. Methods This review was performed according to the PRISMA statement. Databases searched in this review included Pubmed, Web of Science, Scopus, and Cochrane databases for systematic reviews. All English articles on humans reporting isolated MVr using NeoChord DS1000 device were included provided that basic preoperative data, operative specifications, and postoperative mortality and morbidity were reported. Results This review included six studies comprised 249 patients who had NeoChord mitral procedure. Almost all patients included had severe MR (243/249, 97.6%). Operative success was achieved in 241 out of the 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia was reported in six patients (2.4%) and significant bleeding was reported in eight patients (3.2%). Conclusion Awaiting more evidence, NeoChord mitral procedure appears to be a promising procedure that can be considered in selected cases.</abstract><cop>United States</cop><pmid>33476478</pmid><doi>10.1111/jocs.15350</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-4748-6282</orcidid><orcidid>https://orcid.org/0000-0001-8502-9715</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0886-0440
ispartof Journal of cardiac surgery, 2021-04, Vol.36 (4), p.1492-1498
issn 0886-0440
1540-8191
language eng
recordid cdi_proquest_miscellaneous_2480279619
source MEDLINE; Wiley Online Library All Journals
subjects Heart Valve Prosthesis Implantation
Humans
mitral regurgitation
Mitral Valve - surgery
Mitral Valve Insufficiency - surgery
Mitral Valve Prolapse - surgery
mitral valve repair
NeoChord DS1000
Treatment Outcome
title Transapical off‐pump mitral valve repair with NeoChord implantation: A systematic review
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T16%3A21%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transapical%20off%E2%80%90pump%20mitral%20valve%20repair%20with%20NeoChord%20implantation:%20A%20systematic%20review&rft.jtitle=Journal%20of%20cardiac%20surgery&rft.au=Ahmed,%20Ahmed&rft.date=2021-04&rft.volume=36&rft.issue=4&rft.spage=1492&rft.epage=1498&rft.pages=1492-1498&rft.issn=0886-0440&rft.eissn=1540-8191&rft_id=info:doi/10.1111/jocs.15350&rft_dat=%3Cproquest_cross%3E2480279619%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2480279619&rft_id=info:pmid/33476478&rfr_iscdi=true