Experimental validation of the ANTS2 code for modelling optical photon transport in monolithic LYSO crystals

•ANTS2 Monte Carlo code was used to model the transport of optical photons in scintillation-based detectors for PET.•Study of the LYSO background spectrum of monolithic LYSO crystals.•Several optical properties of the scintillator surface wrapping (diffuse reflective, specular reflective or absorben...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica medica 2021-01, Vol.81, p.215-226
Hauptverfasser: Lara-Camacho, Víctor Manuel, Hernández-Acevedo, Edgar Marcial, Alva-Sánchez, Héctor, Murrieta-Rodríguez, Tirso, Martínez-Dávalos, Arnulfo, Moranchel, Mario, Rodríguez-Villafuerte, Mercedes
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 226
container_issue
container_start_page 215
container_title Physica medica
container_volume 81
creator Lara-Camacho, Víctor Manuel
Hernández-Acevedo, Edgar Marcial
Alva-Sánchez, Héctor
Murrieta-Rodríguez, Tirso
Martínez-Dávalos, Arnulfo
Moranchel, Mario
Rodríguez-Villafuerte, Mercedes
description •ANTS2 Monte Carlo code was used to model the transport of optical photons in scintillation-based detectors for PET.•Study of the LYSO background spectrum of monolithic LYSO crystals.•Several optical properties of the scintillator surface wrapping (diffuse reflective, specular reflective or absorbent) were considered.•Good agreement between simulated and experimental data for all cases was found. In this work the scintillation energy spectra originating from the background radioactivity from polished monolithic lutetium yttrium oxyorthosilicate coupled to position-sensitive silicon photomultipliers (SiPM) was studied using the open source Monte Carlo simulation package ANTS2. Two crystal sizes, fully and partially covering the photosensor area, three surface crystal wrappings (black, specular or diffuse) and the full signal formation process in the photosensor were considered. The simulation results were validated with experimental data acquired under the same geometric and detector operating conditions. In all cases ANTS2 simulated spectra have very good agreement with experimental results, reproducing the expected shape, with correct onset and end at 88 and 1190 keV, respectively, as well as sharp edges at the reference energies of 88, 88 + 202, 88 + 307 and 88 + 202 + 307 keV. The normalized root-mean square error between simulated and measured spectra varied between 4.3% and 10.4%.
doi_str_mv 10.1016/j.ejmp.2020.12.022
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2480265073</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1120179721000016</els_id><sourcerecordid>2480265073</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-1cb027bce560661998559000ae9d1b38d53f913bb3a5a6f472d2cc09cf71fa753</originalsourceid><addsrcrecordid>eNp9kE1rGzEQhkVJqPPRP9BD0TGXdaXRateCXkxwm4JJDkkgPQmtdraW2V1tJdnE_z4yTnvsaQbxvC-ah5DPnM0549XX7Ry3wzQHBvkB5gzgA7ngNZQFV_zlLO8cWMFrVc_IZYxbxgSAlB_JTIhyAaVQF6RfvU4Y3IBjMj3dm961Jjk_Ut_RtEG6vH96BGp9i7TzgQ556Xs3_qZ-Ss7myLTxKeMpmDFOPiTqxkyNvndp4yxd_3p8oDYcYq6P1-S8ywM_vc8r8vx99XR7V6wffvy8Xa4LK2SVCm4bBnVjUVasqrhSCykVY8ygankjFq0UneKiaYSRpurKGlqwlinb1bwztRRX5ObUOwX_Z4cx6cFFmz9uRvS7qKFcMKgkq0VG4YTa4GMM2Okp2zDhoDnTR8t6q4-W9dGy5qCz5Rz68t6_awZs_0X-as3AtxOA-cq9w6CjdThabF1Am3Tr3f_63wDHWY7Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2480265073</pqid></control><display><type>article</type><title>Experimental validation of the ANTS2 code for modelling optical photon transport in monolithic LYSO crystals</title><source>Elsevier ScienceDirect Journals</source><creator>Lara-Camacho, Víctor Manuel ; Hernández-Acevedo, Edgar Marcial ; Alva-Sánchez, Héctor ; Murrieta-Rodríguez, Tirso ; Martínez-Dávalos, Arnulfo ; Moranchel, Mario ; Rodríguez-Villafuerte, Mercedes</creator><creatorcontrib>Lara-Camacho, Víctor Manuel ; Hernández-Acevedo, Edgar Marcial ; Alva-Sánchez, Héctor ; Murrieta-Rodríguez, Tirso ; Martínez-Dávalos, Arnulfo ; Moranchel, Mario ; Rodríguez-Villafuerte, Mercedes</creatorcontrib><description>•ANTS2 Monte Carlo code was used to model the transport of optical photons in scintillation-based detectors for PET.•Study of the LYSO background spectrum of monolithic LYSO crystals.•Several optical properties of the scintillator surface wrapping (diffuse reflective, specular reflective or absorbent) were considered.•Good agreement between simulated and experimental data for all cases was found. In this work the scintillation energy spectra originating from the background radioactivity from polished monolithic lutetium yttrium oxyorthosilicate coupled to position-sensitive silicon photomultipliers (SiPM) was studied using the open source Monte Carlo simulation package ANTS2. Two crystal sizes, fully and partially covering the photosensor area, three surface crystal wrappings (black, specular or diffuse) and the full signal formation process in the photosensor were considered. The simulation results were validated with experimental data acquired under the same geometric and detector operating conditions. In all cases ANTS2 simulated spectra have very good agreement with experimental results, reproducing the expected shape, with correct onset and end at 88 and 1190 keV, respectively, as well as sharp edges at the reference energies of 88, 88 + 202, 88 + 307 and 88 + 202 + 307 keV. The normalized root-mean square error between simulated and measured spectra varied between 4.3% and 10.4%.</description><identifier>ISSN: 1120-1797</identifier><identifier>EISSN: 1724-191X</identifier><identifier>DOI: 10.1016/j.ejmp.2020.12.022</identifier><identifier>PMID: 33482439</identifier><language>eng</language><publisher>Italy: Elsevier Ltd</publisher><subject>ANTS2 ; Intrinsic radioactivity ; Light transport ; LYSO ; Monte Carlo simulation ; PET</subject><ispartof>Physica medica, 2021-01, Vol.81, p.215-226</ispartof><rights>2021 Associazione Italiana di Fisica Medica</rights><rights>Copyright © 2021 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-1cb027bce560661998559000ae9d1b38d53f913bb3a5a6f472d2cc09cf71fa753</citedby><cites>FETCH-LOGICAL-c356t-1cb027bce560661998559000ae9d1b38d53f913bb3a5a6f472d2cc09cf71fa753</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1120179721000016$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33482439$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lara-Camacho, Víctor Manuel</creatorcontrib><creatorcontrib>Hernández-Acevedo, Edgar Marcial</creatorcontrib><creatorcontrib>Alva-Sánchez, Héctor</creatorcontrib><creatorcontrib>Murrieta-Rodríguez, Tirso</creatorcontrib><creatorcontrib>Martínez-Dávalos, Arnulfo</creatorcontrib><creatorcontrib>Moranchel, Mario</creatorcontrib><creatorcontrib>Rodríguez-Villafuerte, Mercedes</creatorcontrib><title>Experimental validation of the ANTS2 code for modelling optical photon transport in monolithic LYSO crystals</title><title>Physica medica</title><addtitle>Phys Med</addtitle><description>•ANTS2 Monte Carlo code was used to model the transport of optical photons in scintillation-based detectors for PET.•Study of the LYSO background spectrum of monolithic LYSO crystals.•Several optical properties of the scintillator surface wrapping (diffuse reflective, specular reflective or absorbent) were considered.•Good agreement between simulated and experimental data for all cases was found. In this work the scintillation energy spectra originating from the background radioactivity from polished monolithic lutetium yttrium oxyorthosilicate coupled to position-sensitive silicon photomultipliers (SiPM) was studied using the open source Monte Carlo simulation package ANTS2. Two crystal sizes, fully and partially covering the photosensor area, three surface crystal wrappings (black, specular or diffuse) and the full signal formation process in the photosensor were considered. The simulation results were validated with experimental data acquired under the same geometric and detector operating conditions. In all cases ANTS2 simulated spectra have very good agreement with experimental results, reproducing the expected shape, with correct onset and end at 88 and 1190 keV, respectively, as well as sharp edges at the reference energies of 88, 88 + 202, 88 + 307 and 88 + 202 + 307 keV. The normalized root-mean square error between simulated and measured spectra varied between 4.3% and 10.4%.</description><subject>ANTS2</subject><subject>Intrinsic radioactivity</subject><subject>Light transport</subject><subject>LYSO</subject><subject>Monte Carlo simulation</subject><subject>PET</subject><issn>1120-1797</issn><issn>1724-191X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kE1rGzEQhkVJqPPRP9BD0TGXdaXRateCXkxwm4JJDkkgPQmtdraW2V1tJdnE_z4yTnvsaQbxvC-ah5DPnM0549XX7Ry3wzQHBvkB5gzgA7ngNZQFV_zlLO8cWMFrVc_IZYxbxgSAlB_JTIhyAaVQF6RfvU4Y3IBjMj3dm961Jjk_Ut_RtEG6vH96BGp9i7TzgQ556Xs3_qZ-Ss7myLTxKeMpmDFOPiTqxkyNvndp4yxd_3p8oDYcYq6P1-S8ywM_vc8r8vx99XR7V6wffvy8Xa4LK2SVCm4bBnVjUVasqrhSCykVY8ygankjFq0UneKiaYSRpurKGlqwlinb1bwztRRX5ObUOwX_Z4cx6cFFmz9uRvS7qKFcMKgkq0VG4YTa4GMM2Okp2zDhoDnTR8t6q4-W9dGy5qCz5Rz68t6_awZs_0X-as3AtxOA-cq9w6CjdThabF1Am3Tr3f_63wDHWY7Q</recordid><startdate>202101</startdate><enddate>202101</enddate><creator>Lara-Camacho, Víctor Manuel</creator><creator>Hernández-Acevedo, Edgar Marcial</creator><creator>Alva-Sánchez, Héctor</creator><creator>Murrieta-Rodríguez, Tirso</creator><creator>Martínez-Dávalos, Arnulfo</creator><creator>Moranchel, Mario</creator><creator>Rodríguez-Villafuerte, Mercedes</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202101</creationdate><title>Experimental validation of the ANTS2 code for modelling optical photon transport in monolithic LYSO crystals</title><author>Lara-Camacho, Víctor Manuel ; Hernández-Acevedo, Edgar Marcial ; Alva-Sánchez, Héctor ; Murrieta-Rodríguez, Tirso ; Martínez-Dávalos, Arnulfo ; Moranchel, Mario ; Rodríguez-Villafuerte, Mercedes</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-1cb027bce560661998559000ae9d1b38d53f913bb3a5a6f472d2cc09cf71fa753</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>ANTS2</topic><topic>Intrinsic radioactivity</topic><topic>Light transport</topic><topic>LYSO</topic><topic>Monte Carlo simulation</topic><topic>PET</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lara-Camacho, Víctor Manuel</creatorcontrib><creatorcontrib>Hernández-Acevedo, Edgar Marcial</creatorcontrib><creatorcontrib>Alva-Sánchez, Héctor</creatorcontrib><creatorcontrib>Murrieta-Rodríguez, Tirso</creatorcontrib><creatorcontrib>Martínez-Dávalos, Arnulfo</creatorcontrib><creatorcontrib>Moranchel, Mario</creatorcontrib><creatorcontrib>Rodríguez-Villafuerte, Mercedes</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physica medica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lara-Camacho, Víctor Manuel</au><au>Hernández-Acevedo, Edgar Marcial</au><au>Alva-Sánchez, Héctor</au><au>Murrieta-Rodríguez, Tirso</au><au>Martínez-Dávalos, Arnulfo</au><au>Moranchel, Mario</au><au>Rodríguez-Villafuerte, Mercedes</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental validation of the ANTS2 code for modelling optical photon transport in monolithic LYSO crystals</atitle><jtitle>Physica medica</jtitle><addtitle>Phys Med</addtitle><date>2021-01</date><risdate>2021</risdate><volume>81</volume><spage>215</spage><epage>226</epage><pages>215-226</pages><issn>1120-1797</issn><eissn>1724-191X</eissn><abstract>•ANTS2 Monte Carlo code was used to model the transport of optical photons in scintillation-based detectors for PET.•Study of the LYSO background spectrum of monolithic LYSO crystals.•Several optical properties of the scintillator surface wrapping (diffuse reflective, specular reflective or absorbent) were considered.•Good agreement between simulated and experimental data for all cases was found. In this work the scintillation energy spectra originating from the background radioactivity from polished monolithic lutetium yttrium oxyorthosilicate coupled to position-sensitive silicon photomultipliers (SiPM) was studied using the open source Monte Carlo simulation package ANTS2. Two crystal sizes, fully and partially covering the photosensor area, three surface crystal wrappings (black, specular or diffuse) and the full signal formation process in the photosensor were considered. The simulation results were validated with experimental data acquired under the same geometric and detector operating conditions. In all cases ANTS2 simulated spectra have very good agreement with experimental results, reproducing the expected shape, with correct onset and end at 88 and 1190 keV, respectively, as well as sharp edges at the reference energies of 88, 88 + 202, 88 + 307 and 88 + 202 + 307 keV. The normalized root-mean square error between simulated and measured spectra varied between 4.3% and 10.4%.</abstract><cop>Italy</cop><pub>Elsevier Ltd</pub><pmid>33482439</pmid><doi>10.1016/j.ejmp.2020.12.022</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1120-1797
ispartof Physica medica, 2021-01, Vol.81, p.215-226
issn 1120-1797
1724-191X
language eng
recordid cdi_proquest_miscellaneous_2480265073
source Elsevier ScienceDirect Journals
subjects ANTS2
Intrinsic radioactivity
Light transport
LYSO
Monte Carlo simulation
PET
title Experimental validation of the ANTS2 code for modelling optical photon transport in monolithic LYSO crystals
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T09%3A34%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20validation%20of%20the%20ANTS2%20code%20for%20modelling%20optical%20photon%20transport%20in%20monolithic%20LYSO%20crystals&rft.jtitle=Physica%20medica&rft.au=Lara-Camacho,%20V%C3%ADctor%20Manuel&rft.date=2021-01&rft.volume=81&rft.spage=215&rft.epage=226&rft.pages=215-226&rft.issn=1120-1797&rft.eissn=1724-191X&rft_id=info:doi/10.1016/j.ejmp.2020.12.022&rft_dat=%3Cproquest_cross%3E2480265073%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2480265073&rft_id=info:pmid/33482439&rft_els_id=S1120179721000016&rfr_iscdi=true