“Pumpology”: the Realistic Issues Associated with Pump Placement in Prosthetic Surgery
Purpose of Review The goal of this paper was to discuss the issues and/or overt complications associated with the 3-piece inflatable penile prosthesis (3-IPP) pump. We also addressed how to resolve such issues with or without surgical intervention. Recent Findings Numerous modifications of the 3-IPP...
Gespeichert in:
Veröffentlicht in: | Current urology reports 2021-01, Vol.22 (2), p.10-10, Article 10 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 10 |
---|---|
container_issue | 2 |
container_start_page | 10 |
container_title | Current urology reports |
container_volume | 22 |
creator | Fernandez-Crespo, Raul E. Buscaino, Kristina Carrion, Rafael |
description | Purpose of Review
The goal of this paper was to discuss the issues and/or overt complications associated with the 3-piece inflatable penile prosthesis (3-IPP) pump. We also addressed how to resolve such issues with or without surgical intervention.
Recent Findings
Numerous modifications of the 3-IPP pump have been introduced with multiple techniques to place the pump. These are largely dependent on the approach to place the 3-IPP. Pump issues may inevitably occur, and there are numerous special maneuvers that can be performed to resolve pump issues.
Summary
It is important for urologists to know maneuvers for pump malfunctions to prevent unnecessary surgical procedures and pump revision. Several studies are reviewed regarding pump issues and patient satisfaction; however, a more structured prospective research project is warranted to further evaluate these issues. |
doi_str_mv | 10.1007/s11934-020-01027-5 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2476561119</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2476561119</sourcerecordid><originalsourceid>FETCH-LOGICAL-c347t-d37a260f7b0bc718437f5a87f32b72bd7fb0c31a7c08a6f7f6f13a265067694a3</originalsourceid><addsrcrecordid>eNp9kMlOwzAQhi0EoqXwAhyQj1wCXhI74VZVLJUqUbFcuFiOY7epshQ7EeqtDwIv1yfBIYUjJ1sz_zea-QA4x-gKI8SvHcYJDQNEUIAwIjyIDsAQR77ESBwddn9fJJzyAThxboV8EsXhMRhQGhKU0GQI3nbbz3lbruuiXmx2268b2Cw1fNKyyF2TKzh1rtUOjp2rVS4bncGPvFnCDoHzQipd6qqBeQXntnYe7Zjn1i603ZyCIyMLp8_27wi83t2-TB6C2eP9dDKeBYqGvAkyyiVhyPAUpYrjOKTcRDLmhpKUkzTjJkWKYskViiUz3DCDqScixDhLQklH4LKfu7b1u1-2EWXulC4KWem6dYKEnEUMd7JGgPRR5bd1Vhuxtnkp7UZgJDqnoncqvCnx41REHrrYz2_TUmd_yK9EH6B9wPlW5U8Xq7q1lb_5v7HfcPaDuw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2476561119</pqid></control><display><type>article</type><title>“Pumpology”: the Realistic Issues Associated with Pump Placement in Prosthetic Surgery</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Fernandez-Crespo, Raul E. ; Buscaino, Kristina ; Carrion, Rafael</creator><creatorcontrib>Fernandez-Crespo, Raul E. ; Buscaino, Kristina ; Carrion, Rafael</creatorcontrib><description>Purpose of Review
The goal of this paper was to discuss the issues and/or overt complications associated with the 3-piece inflatable penile prosthesis (3-IPP) pump. We also addressed how to resolve such issues with or without surgical intervention.
Recent Findings
Numerous modifications of the 3-IPP pump have been introduced with multiple techniques to place the pump. These are largely dependent on the approach to place the 3-IPP. Pump issues may inevitably occur, and there are numerous special maneuvers that can be performed to resolve pump issues.
Summary
It is important for urologists to know maneuvers for pump malfunctions to prevent unnecessary surgical procedures and pump revision. Several studies are reviewed regarding pump issues and patient satisfaction; however, a more structured prospective research project is warranted to further evaluate these issues.</description><identifier>ISSN: 1527-2737</identifier><identifier>EISSN: 1534-6285</identifier><identifier>DOI: 10.1007/s11934-020-01027-5</identifier><identifier>PMID: 33420939</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Erectile Dysfunction - surgery ; Humans ; Male ; Medicine ; Medicine & Public Health ; Men's Health (R Carrion ; Nephrology ; Patient Satisfaction ; Penile Implantation - adverse effects ; Penile Implantation - instrumentation ; Penile Implantation - methods ; Penile Prosthesis - adverse effects ; Prospective Studies ; Prosthesis Design - adverse effects ; Prosthesis Failure - adverse effects ; Reoperation ; Section Editor ; Topical Collection on Men’s Health ; Urology</subject><ispartof>Current urology reports, 2021-01, Vol.22 (2), p.10-10, Article 10</ispartof><rights>The Author(s), under exclusive licence to Springer Science+Business Media, LLC part of Springer Nature 2021</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c347t-d37a260f7b0bc718437f5a87f32b72bd7fb0c31a7c08a6f7f6f13a265067694a3</citedby><cites>FETCH-LOGICAL-c347t-d37a260f7b0bc718437f5a87f32b72bd7fb0c31a7c08a6f7f6f13a265067694a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s11934-020-01027-5$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s11934-020-01027-5$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33420939$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fernandez-Crespo, Raul E.</creatorcontrib><creatorcontrib>Buscaino, Kristina</creatorcontrib><creatorcontrib>Carrion, Rafael</creatorcontrib><title>“Pumpology”: the Realistic Issues Associated with Pump Placement in Prosthetic Surgery</title><title>Current urology reports</title><addtitle>Curr Urol Rep</addtitle><addtitle>Curr Urol Rep</addtitle><description>Purpose of Review
The goal of this paper was to discuss the issues and/or overt complications associated with the 3-piece inflatable penile prosthesis (3-IPP) pump. We also addressed how to resolve such issues with or without surgical intervention.
Recent Findings
Numerous modifications of the 3-IPP pump have been introduced with multiple techniques to place the pump. These are largely dependent on the approach to place the 3-IPP. Pump issues may inevitably occur, and there are numerous special maneuvers that can be performed to resolve pump issues.
Summary
It is important for urologists to know maneuvers for pump malfunctions to prevent unnecessary surgical procedures and pump revision. Several studies are reviewed regarding pump issues and patient satisfaction; however, a more structured prospective research project is warranted to further evaluate these issues.</description><subject>Erectile Dysfunction - surgery</subject><subject>Humans</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Men's Health (R Carrion</subject><subject>Nephrology</subject><subject>Patient Satisfaction</subject><subject>Penile Implantation - adverse effects</subject><subject>Penile Implantation - instrumentation</subject><subject>Penile Implantation - methods</subject><subject>Penile Prosthesis - adverse effects</subject><subject>Prospective Studies</subject><subject>Prosthesis Design - adverse effects</subject><subject>Prosthesis Failure - adverse effects</subject><subject>Reoperation</subject><subject>Section Editor</subject><subject>Topical Collection on Men’s Health</subject><subject>Urology</subject><issn>1527-2737</issn><issn>1534-6285</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMlOwzAQhi0EoqXwAhyQj1wCXhI74VZVLJUqUbFcuFiOY7epshQ7EeqtDwIv1yfBIYUjJ1sz_zea-QA4x-gKI8SvHcYJDQNEUIAwIjyIDsAQR77ESBwddn9fJJzyAThxboV8EsXhMRhQGhKU0GQI3nbbz3lbruuiXmx2268b2Cw1fNKyyF2TKzh1rtUOjp2rVS4bncGPvFnCDoHzQipd6qqBeQXntnYe7Zjn1i603ZyCIyMLp8_27wi83t2-TB6C2eP9dDKeBYqGvAkyyiVhyPAUpYrjOKTcRDLmhpKUkzTjJkWKYskViiUz3DCDqScixDhLQklH4LKfu7b1u1-2EWXulC4KWem6dYKEnEUMd7JGgPRR5bd1Vhuxtnkp7UZgJDqnoncqvCnx41REHrrYz2_TUmd_yK9EH6B9wPlW5U8Xq7q1lb_5v7HfcPaDuw</recordid><startdate>20210109</startdate><enddate>20210109</enddate><creator>Fernandez-Crespo, Raul E.</creator><creator>Buscaino, Kristina</creator><creator>Carrion, Rafael</creator><general>Springer US</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20210109</creationdate><title>“Pumpology”: the Realistic Issues Associated with Pump Placement in Prosthetic Surgery</title><author>Fernandez-Crespo, Raul E. ; Buscaino, Kristina ; Carrion, Rafael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c347t-d37a260f7b0bc718437f5a87f32b72bd7fb0c31a7c08a6f7f6f13a265067694a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Erectile Dysfunction - surgery</topic><topic>Humans</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Men's Health (R Carrion</topic><topic>Nephrology</topic><topic>Patient Satisfaction</topic><topic>Penile Implantation - adverse effects</topic><topic>Penile Implantation - instrumentation</topic><topic>Penile Implantation - methods</topic><topic>Penile Prosthesis - adverse effects</topic><topic>Prospective Studies</topic><topic>Prosthesis Design - adverse effects</topic><topic>Prosthesis Failure - adverse effects</topic><topic>Reoperation</topic><topic>Section Editor</topic><topic>Topical Collection on Men’s Health</topic><topic>Urology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fernandez-Crespo, Raul E.</creatorcontrib><creatorcontrib>Buscaino, Kristina</creatorcontrib><creatorcontrib>Carrion, Rafael</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Current urology reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fernandez-Crespo, Raul E.</au><au>Buscaino, Kristina</au><au>Carrion, Rafael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>“Pumpology”: the Realistic Issues Associated with Pump Placement in Prosthetic Surgery</atitle><jtitle>Current urology reports</jtitle><stitle>Curr Urol Rep</stitle><addtitle>Curr Urol Rep</addtitle><date>2021-01-09</date><risdate>2021</risdate><volume>22</volume><issue>2</issue><spage>10</spage><epage>10</epage><pages>10-10</pages><artnum>10</artnum><issn>1527-2737</issn><eissn>1534-6285</eissn><abstract>Purpose of Review
The goal of this paper was to discuss the issues and/or overt complications associated with the 3-piece inflatable penile prosthesis (3-IPP) pump. We also addressed how to resolve such issues with or without surgical intervention.
Recent Findings
Numerous modifications of the 3-IPP pump have been introduced with multiple techniques to place the pump. These are largely dependent on the approach to place the 3-IPP. Pump issues may inevitably occur, and there are numerous special maneuvers that can be performed to resolve pump issues.
Summary
It is important for urologists to know maneuvers for pump malfunctions to prevent unnecessary surgical procedures and pump revision. Several studies are reviewed regarding pump issues and patient satisfaction; however, a more structured prospective research project is warranted to further evaluate these issues.</abstract><cop>New York</cop><pub>Springer US</pub><pmid>33420939</pmid><doi>10.1007/s11934-020-01027-5</doi><tpages>1</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1527-2737 |
ispartof | Current urology reports, 2021-01, Vol.22 (2), p.10-10, Article 10 |
issn | 1527-2737 1534-6285 |
language | eng |
recordid | cdi_proquest_miscellaneous_2476561119 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Erectile Dysfunction - surgery Humans Male Medicine Medicine & Public Health Men's Health (R Carrion Nephrology Patient Satisfaction Penile Implantation - adverse effects Penile Implantation - instrumentation Penile Implantation - methods Penile Prosthesis - adverse effects Prospective Studies Prosthesis Design - adverse effects Prosthesis Failure - adverse effects Reoperation Section Editor Topical Collection on Men’s Health Urology |
title | “Pumpology”: the Realistic Issues Associated with Pump Placement in Prosthetic Surgery |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T14%3A54%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=%E2%80%9CPumpology%E2%80%9D:%20the%20Realistic%20Issues%20Associated%20with%20Pump%20Placement%20in%20Prosthetic%20Surgery&rft.jtitle=Current%20urology%20reports&rft.au=Fernandez-Crespo,%20Raul%20E.&rft.date=2021-01-09&rft.volume=22&rft.issue=2&rft.spage=10&rft.epage=10&rft.pages=10-10&rft.artnum=10&rft.issn=1527-2737&rft.eissn=1534-6285&rft_id=info:doi/10.1007/s11934-020-01027-5&rft_dat=%3Cproquest_cross%3E2476561119%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2476561119&rft_id=info:pmid/33420939&rfr_iscdi=true |