Usefulness of Transesophageal Echocardiography in the Evaluation of Celiac Trunk and Superior Mesenteric Artery Involvement in Acute Aortic Dissection

Mesenteric ischemia is a serious complication of acute aortic dissection (AAD), and its early diagnosis is vital for prognosis and appropriate treatment indication. Arteries affected by this complication are the celiac trunk and superior mesenteric artery, and their evaluation is usually based on co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society of Echocardiography 2021-04, Vol.34 (4), p.327-335
Hauptverfasser: Moral, Sergio, Avegliano, Gustavo, Cuéllar, Hug, Ballesteros, Esther, Rodríguez-Palomares, Jose, Teixidó, Gisela, Galian, Laura, Gutiérrez, Laura, Evangelista, Arturo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 335
container_issue 4
container_start_page 327
container_title Journal of the American Society of Echocardiography
container_volume 34
creator Moral, Sergio
Avegliano, Gustavo
Cuéllar, Hug
Ballesteros, Esther
Rodríguez-Palomares, Jose
Teixidó, Gisela
Galian, Laura
Gutiérrez, Laura
Evangelista, Arturo
description Mesenteric ischemia is a serious complication of acute aortic dissection (AAD), and its early diagnosis is vital for prognosis and appropriate treatment indication. Arteries affected by this complication are the celiac trunk and superior mesenteric artery, and their evaluation is usually based on computed tomographic angiography. Transesophageal echocardiography is also a useful technique for diagnosing AAD and is essential in monitoring surgical or endovascular treatment when computed tomographic angiography is not available. However, the usefulness of transesophageal echocardiography for evaluating celiac trunk and superior mesenteric artery involvement and mesenteric ischemia mechanisms in AAD is not well established. Real-time information on mesenteric malperfusion is needed at the bedside, in primary care facilities, and in the operating room to achieve prompt diagnosis and better therapeutic management. The aims of this review are to assess the role of TEE to diagnose celiac trunk and superior mesenteric artery involvement in AAD, determine the mechanisms that can cause flow obstruction in patients with mesenteric ischemia, and analyze possible implications in the treatment of this complication. •TEE is useful for evaluating CTr and SMA involvement in AAD.•TEE can distinguish between static and dynamic obstruction mechanisms.•TEE performed in AAD evaluation should routinely include study of the CTr and SMA.•TEE is useful to monitor treatment according to the mechanism of vessel obstruction.
doi_str_mv 10.1016/j.echo.2020.12.019
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2474844023</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0894731720308130</els_id><sourcerecordid>2474844023</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-4010322320427351b6a668da49b5412c17f1946b8544e9df0de23ca90fcea90e3</originalsourceid><addsrcrecordid>eNp9kU1PGzEQhq2qqKS0f6AH5GMvG8Yf-yVxidK0IIE4AGfL8c4Spxt7sXcj5Y_we_EqwJHLzGj0vO_Ifgn5xWDOgBUX2zmajZ9z4GnB58DqL2TGoC6zoqzzr2QGVS2zUrDylHyPcQsAeQXwjZwKIao8Bz4jL48R27FzGCP1LX0I2kWMvt_oJ9QdXaUDRofG-qeg-82BWkeHDdLVXnejHqx3k2qJndUmiUf3n2rX0Puxx2B9oLcY0Q1pNnQRUj_Qa7f33R53aT2ZLcw4IF34MCTkj40RzeT6g5y0uov4862fkce_q4flVXZz9-96ubjJjMiLIZPAQHAuOEheipytC10UVaNlvc4l44aVLatlsa5yKbFuWmiQC6NraA2miuKM_D769sE_jxgHtbPRYNdph36MistSVlICFwnlR9QEH2PAVvXB7nQ4KAZqykNt1ZSHmvJQjKuURxKdv_mP6x02H5L3ABJweQQwvXJvMahoLDqDjQ3pK1Tj7Wf-rzJOniA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2474844023</pqid></control><display><type>article</type><title>Usefulness of Transesophageal Echocardiography in the Evaluation of Celiac Trunk and Superior Mesenteric Artery Involvement in Acute Aortic Dissection</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Moral, Sergio ; Avegliano, Gustavo ; Cuéllar, Hug ; Ballesteros, Esther ; Rodríguez-Palomares, Jose ; Teixidó, Gisela ; Galian, Laura ; Gutiérrez, Laura ; Evangelista, Arturo</creator><creatorcontrib>Moral, Sergio ; Avegliano, Gustavo ; Cuéllar, Hug ; Ballesteros, Esther ; Rodríguez-Palomares, Jose ; Teixidó, Gisela ; Galian, Laura ; Gutiérrez, Laura ; Evangelista, Arturo</creatorcontrib><description>Mesenteric ischemia is a serious complication of acute aortic dissection (AAD), and its early diagnosis is vital for prognosis and appropriate treatment indication. Arteries affected by this complication are the celiac trunk and superior mesenteric artery, and their evaluation is usually based on computed tomographic angiography. Transesophageal echocardiography is also a useful technique for diagnosing AAD and is essential in monitoring surgical or endovascular treatment when computed tomographic angiography is not available. However, the usefulness of transesophageal echocardiography for evaluating celiac trunk and superior mesenteric artery involvement and mesenteric ischemia mechanisms in AAD is not well established. Real-time information on mesenteric malperfusion is needed at the bedside, in primary care facilities, and in the operating room to achieve prompt diagnosis and better therapeutic management. The aims of this review are to assess the role of TEE to diagnose celiac trunk and superior mesenteric artery involvement in AAD, determine the mechanisms that can cause flow obstruction in patients with mesenteric ischemia, and analyze possible implications in the treatment of this complication. •TEE is useful for evaluating CTr and SMA involvement in AAD.•TEE can distinguish between static and dynamic obstruction mechanisms.•TEE performed in AAD evaluation should routinely include study of the CTr and SMA.•TEE is useful to monitor treatment according to the mechanism of vessel obstruction.</description><identifier>ISSN: 0894-7317</identifier><identifier>EISSN: 1097-6795</identifier><identifier>DOI: 10.1016/j.echo.2020.12.019</identifier><identifier>PMID: 33385502</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Acute aortic dissection ; Celiac trunk ; Mesenteric ischemia ; Superior mesenteric artery ; Transesophageal echocardiography</subject><ispartof>Journal of the American Society of Echocardiography, 2021-04, Vol.34 (4), p.327-335</ispartof><rights>2021 American Society of Echocardiography</rights><rights>Copyright © 2021 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-4010322320427351b6a668da49b5412c17f1946b8544e9df0de23ca90fcea90e3</citedby><cites>FETCH-LOGICAL-c356t-4010322320427351b6a668da49b5412c17f1946b8544e9df0de23ca90fcea90e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0894731720308130$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33385502$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Moral, Sergio</creatorcontrib><creatorcontrib>Avegliano, Gustavo</creatorcontrib><creatorcontrib>Cuéllar, Hug</creatorcontrib><creatorcontrib>Ballesteros, Esther</creatorcontrib><creatorcontrib>Rodríguez-Palomares, Jose</creatorcontrib><creatorcontrib>Teixidó, Gisela</creatorcontrib><creatorcontrib>Galian, Laura</creatorcontrib><creatorcontrib>Gutiérrez, Laura</creatorcontrib><creatorcontrib>Evangelista, Arturo</creatorcontrib><title>Usefulness of Transesophageal Echocardiography in the Evaluation of Celiac Trunk and Superior Mesenteric Artery Involvement in Acute Aortic Dissection</title><title>Journal of the American Society of Echocardiography</title><addtitle>J Am Soc Echocardiogr</addtitle><description>Mesenteric ischemia is a serious complication of acute aortic dissection (AAD), and its early diagnosis is vital for prognosis and appropriate treatment indication. Arteries affected by this complication are the celiac trunk and superior mesenteric artery, and their evaluation is usually based on computed tomographic angiography. Transesophageal echocardiography is also a useful technique for diagnosing AAD and is essential in monitoring surgical or endovascular treatment when computed tomographic angiography is not available. However, the usefulness of transesophageal echocardiography for evaluating celiac trunk and superior mesenteric artery involvement and mesenteric ischemia mechanisms in AAD is not well established. Real-time information on mesenteric malperfusion is needed at the bedside, in primary care facilities, and in the operating room to achieve prompt diagnosis and better therapeutic management. The aims of this review are to assess the role of TEE to diagnose celiac trunk and superior mesenteric artery involvement in AAD, determine the mechanisms that can cause flow obstruction in patients with mesenteric ischemia, and analyze possible implications in the treatment of this complication. •TEE is useful for evaluating CTr and SMA involvement in AAD.•TEE can distinguish between static and dynamic obstruction mechanisms.•TEE performed in AAD evaluation should routinely include study of the CTr and SMA.•TEE is useful to monitor treatment according to the mechanism of vessel obstruction.</description><subject>Acute aortic dissection</subject><subject>Celiac trunk</subject><subject>Mesenteric ischemia</subject><subject>Superior mesenteric artery</subject><subject>Transesophageal echocardiography</subject><issn>0894-7317</issn><issn>1097-6795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kU1PGzEQhq2qqKS0f6AH5GMvG8Yf-yVxidK0IIE4AGfL8c4Spxt7sXcj5Y_we_EqwJHLzGj0vO_Ifgn5xWDOgBUX2zmajZ9z4GnB58DqL2TGoC6zoqzzr2QGVS2zUrDylHyPcQsAeQXwjZwKIao8Bz4jL48R27FzGCP1LX0I2kWMvt_oJ9QdXaUDRofG-qeg-82BWkeHDdLVXnejHqx3k2qJndUmiUf3n2rX0Puxx2B9oLcY0Q1pNnQRUj_Qa7f33R53aT2ZLcw4IF34MCTkj40RzeT6g5y0uov4862fkce_q4flVXZz9-96ubjJjMiLIZPAQHAuOEheipytC10UVaNlvc4l44aVLatlsa5yKbFuWmiQC6NraA2miuKM_D769sE_jxgHtbPRYNdph36MistSVlICFwnlR9QEH2PAVvXB7nQ4KAZqykNt1ZSHmvJQjKuURxKdv_mP6x02H5L3ABJweQQwvXJvMahoLDqDjQ3pK1Tj7Wf-rzJOniA</recordid><startdate>202104</startdate><enddate>202104</enddate><creator>Moral, Sergio</creator><creator>Avegliano, Gustavo</creator><creator>Cuéllar, Hug</creator><creator>Ballesteros, Esther</creator><creator>Rodríguez-Palomares, Jose</creator><creator>Teixidó, Gisela</creator><creator>Galian, Laura</creator><creator>Gutiérrez, Laura</creator><creator>Evangelista, Arturo</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202104</creationdate><title>Usefulness of Transesophageal Echocardiography in the Evaluation of Celiac Trunk and Superior Mesenteric Artery Involvement in Acute Aortic Dissection</title><author>Moral, Sergio ; Avegliano, Gustavo ; Cuéllar, Hug ; Ballesteros, Esther ; Rodríguez-Palomares, Jose ; Teixidó, Gisela ; Galian, Laura ; Gutiérrez, Laura ; Evangelista, Arturo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-4010322320427351b6a668da49b5412c17f1946b8544e9df0de23ca90fcea90e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Acute aortic dissection</topic><topic>Celiac trunk</topic><topic>Mesenteric ischemia</topic><topic>Superior mesenteric artery</topic><topic>Transesophageal echocardiography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Moral, Sergio</creatorcontrib><creatorcontrib>Avegliano, Gustavo</creatorcontrib><creatorcontrib>Cuéllar, Hug</creatorcontrib><creatorcontrib>Ballesteros, Esther</creatorcontrib><creatorcontrib>Rodríguez-Palomares, Jose</creatorcontrib><creatorcontrib>Teixidó, Gisela</creatorcontrib><creatorcontrib>Galian, Laura</creatorcontrib><creatorcontrib>Gutiérrez, Laura</creatorcontrib><creatorcontrib>Evangelista, Arturo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society of Echocardiography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Moral, Sergio</au><au>Avegliano, Gustavo</au><au>Cuéllar, Hug</au><au>Ballesteros, Esther</au><au>Rodríguez-Palomares, Jose</au><au>Teixidó, Gisela</au><au>Galian, Laura</au><au>Gutiérrez, Laura</au><au>Evangelista, Arturo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Usefulness of Transesophageal Echocardiography in the Evaluation of Celiac Trunk and Superior Mesenteric Artery Involvement in Acute Aortic Dissection</atitle><jtitle>Journal of the American Society of Echocardiography</jtitle><addtitle>J Am Soc Echocardiogr</addtitle><date>2021-04</date><risdate>2021</risdate><volume>34</volume><issue>4</issue><spage>327</spage><epage>335</epage><pages>327-335</pages><issn>0894-7317</issn><eissn>1097-6795</eissn><abstract>Mesenteric ischemia is a serious complication of acute aortic dissection (AAD), and its early diagnosis is vital for prognosis and appropriate treatment indication. Arteries affected by this complication are the celiac trunk and superior mesenteric artery, and their evaluation is usually based on computed tomographic angiography. Transesophageal echocardiography is also a useful technique for diagnosing AAD and is essential in monitoring surgical or endovascular treatment when computed tomographic angiography is not available. However, the usefulness of transesophageal echocardiography for evaluating celiac trunk and superior mesenteric artery involvement and mesenteric ischemia mechanisms in AAD is not well established. Real-time information on mesenteric malperfusion is needed at the bedside, in primary care facilities, and in the operating room to achieve prompt diagnosis and better therapeutic management. The aims of this review are to assess the role of TEE to diagnose celiac trunk and superior mesenteric artery involvement in AAD, determine the mechanisms that can cause flow obstruction in patients with mesenteric ischemia, and analyze possible implications in the treatment of this complication. •TEE is useful for evaluating CTr and SMA involvement in AAD.•TEE can distinguish between static and dynamic obstruction mechanisms.•TEE performed in AAD evaluation should routinely include study of the CTr and SMA.•TEE is useful to monitor treatment according to the mechanism of vessel obstruction.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>33385502</pmid><doi>10.1016/j.echo.2020.12.019</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0894-7317
ispartof Journal of the American Society of Echocardiography, 2021-04, Vol.34 (4), p.327-335
issn 0894-7317
1097-6795
language eng
recordid cdi_proquest_miscellaneous_2474844023
source ScienceDirect Journals (5 years ago - present)
subjects Acute aortic dissection
Celiac trunk
Mesenteric ischemia
Superior mesenteric artery
Transesophageal echocardiography
title Usefulness of Transesophageal Echocardiography in the Evaluation of Celiac Trunk and Superior Mesenteric Artery Involvement in Acute Aortic Dissection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T18%3A50%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Usefulness%20of%20Transesophageal%20Echocardiography%20in%20the%20Evaluation%20of%20Celiac%20Trunk%20and%20Superior%20Mesenteric%20Artery%20Involvement%20in%20Acute%20Aortic%20Dissection&rft.jtitle=Journal%20of%20the%20American%20Society%20of%20Echocardiography&rft.au=Moral,%20Sergio&rft.date=2021-04&rft.volume=34&rft.issue=4&rft.spage=327&rft.epage=335&rft.pages=327-335&rft.issn=0894-7317&rft.eissn=1097-6795&rft_id=info:doi/10.1016/j.echo.2020.12.019&rft_dat=%3Cproquest_cross%3E2474844023%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2474844023&rft_id=info:pmid/33385502&rft_els_id=S0894731720308130&rfr_iscdi=true