Evaluation of cone-beam computed tomography over a small field of view in a water bath based on the modulation transfer function with repeating-edge oversampling

Purpose: The spatial resolution of cone-beam computed tomography (CBCT) in small fields of view (FOVs) is important for clinical applications. However, it is difficult to measure spatial resolution reliably due to error factors such as noise. The aim of this study was to obtain a modulation transfer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Oral Science 2021, Vol.63(1), pp.87-91
Hauptverfasser: Ito, Motohiro, Hayashi, Yusuke, Matsumoto, Kunihito, Arai, Yoshinori, Honda, Kazuya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 91
container_issue 1
container_start_page 87
container_title Journal of Oral Science
container_volume 63
creator Ito, Motohiro
Hayashi, Yusuke
Matsumoto, Kunihito
Arai, Yoshinori
Honda, Kazuya
description Purpose: The spatial resolution of cone-beam computed tomography (CBCT) in small fields of view (FOVs) is important for clinical applications. However, it is difficult to measure spatial resolution reliably due to error factors such as noise. The aim of this study was to obtain a modulation transfer function (MTF) more accurately.Methods: A CBCT apparatus was used with small FOV. An aluminum pipe slightly tilted at an inclination ratio of 77/3 (25.7) was used as the measurement phantom. The MTF was calculated from the edge image of the phantom. The actual oversampling ratio was determined by regression analysis. The experiment was repeated 16 times and the edge-spread function (ESF) was approximated by the least-square method. Furthermore, a low-pass filter (LPF) was applied to eliminate the component at frequencies above the Nyquist frequency. Finally, the MTF was calculated from the pre-processed ESF.Results: Results showed that pre-processing reduced the noise of the ESF. The MTFs at frequencies of 1.0 and 2.0 LP/mm were 0.59 and 0.18, respectively, in air and 0.52 and 0.16, respectively, in water.Conclusion: The repeating-edge oversampling method combined with ESF pre-processing improved the accuracy of the MTF under clinically relevant conditions with a phantom.
doi_str_mv 10.2334/josnusd.20-0479
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2470028825</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2470028825</sourcerecordid><originalsourceid>FETCH-LOGICAL-c444t-d3a8564c5c1c59b662267e15c06c0796437a9f433066e678769f0c47290d7f5a3</originalsourceid><addsrcrecordid>eNo9kT9v2zAQxYWiRZMmmbsVHLso4T-R0lgEblIgQJd2Js7U0ZZBiSpJ2cjH6TctHbtejoe733sH4lXVZ0bvuRDyYRfStKT-ntOaSt29q65Z29Jadly9L72QovRCXlWfUtpRKrnSzcfqSgjBGGXiuvq72oNfIA9hIsERGyas1whj6cZ5ydiTHMawiTBvX0nYYyRA0gjeEzeg74-a_YAHMkxlcYBcgDXkbSmpaItp3iIZQ7_4040cYUquUG6Z7NvkMBQ84owFmDY19ht8O5RgnH2Z3FYfHPiEd-f3pvr9ffXr8bl--fn04_HbS22llLnuBbSNkraxzDbdWile_oqssVRZqjslhYbOSSGoUqh0q1XnqJWad7TXrgFxU309-c4x_FkwZTMOyaL3MGFYkuFSU8rbljcFfTihNoaUIjozx2GE-GoYNcdczDkXw6k55lIUX87my3rE_sL_D6IAqxOwSxk2eAEg5sF6vBgqYdixnI0ve7uFaHAS_wDGcaZO</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2470028825</pqid></control><display><type>article</type><title>Evaluation of cone-beam computed tomography over a small field of view in a water bath based on the modulation transfer function with repeating-edge oversampling</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Freely Accessible Japanese Titles</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Ito, Motohiro ; Hayashi, Yusuke ; Matsumoto, Kunihito ; Arai, Yoshinori ; Honda, Kazuya</creator><creatorcontrib>Ito, Motohiro ; Hayashi, Yusuke ; Matsumoto, Kunihito ; Arai, Yoshinori ; Honda, Kazuya</creatorcontrib><description>Purpose: The spatial resolution of cone-beam computed tomography (CBCT) in small fields of view (FOVs) is important for clinical applications. However, it is difficult to measure spatial resolution reliably due to error factors such as noise. The aim of this study was to obtain a modulation transfer function (MTF) more accurately.Methods: A CBCT apparatus was used with small FOV. An aluminum pipe slightly tilted at an inclination ratio of 77/3 (25.7) was used as the measurement phantom. The MTF was calculated from the edge image of the phantom. The actual oversampling ratio was determined by regression analysis. The experiment was repeated 16 times and the edge-spread function (ESF) was approximated by the least-square method. Furthermore, a low-pass filter (LPF) was applied to eliminate the component at frequencies above the Nyquist frequency. Finally, the MTF was calculated from the pre-processed ESF.Results: Results showed that pre-processing reduced the noise of the ESF. The MTFs at frequencies of 1.0 and 2.0 LP/mm were 0.59 and 0.18, respectively, in air and 0.52 and 0.16, respectively, in water.Conclusion: The repeating-edge oversampling method combined with ESF pre-processing improved the accuracy of the MTF under clinically relevant conditions with a phantom.</description><identifier>ISSN: 1343-4934</identifier><identifier>EISSN: 1880-4926</identifier><identifier>DOI: 10.2334/josnusd.20-0479</identifier><identifier>PMID: 33311013</identifier><language>eng</language><publisher>Japan: Nihon University School of Dentistry</publisher><subject>computed tomography ; cone beam ; Cone-Beam Computed Tomography ; dental ; Dentistry ; Image Processing, Computer-Assisted ; modulation transfer function ; Phantoms, Imaging ; Water</subject><ispartof>Journal of Oral Science, 2021, Vol.63(1), pp.87-91</ispartof><rights>2021 by Nihon University School of Dentistry</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c444t-d3a8564c5c1c59b662267e15c06c0796437a9f433066e678769f0c47290d7f5a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33311013$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ito, Motohiro</creatorcontrib><creatorcontrib>Hayashi, Yusuke</creatorcontrib><creatorcontrib>Matsumoto, Kunihito</creatorcontrib><creatorcontrib>Arai, Yoshinori</creatorcontrib><creatorcontrib>Honda, Kazuya</creatorcontrib><title>Evaluation of cone-beam computed tomography over a small field of view in a water bath based on the modulation transfer function with repeating-edge oversampling</title><title>Journal of Oral Science</title><addtitle>J Oral Sci</addtitle><description>Purpose: The spatial resolution of cone-beam computed tomography (CBCT) in small fields of view (FOVs) is important for clinical applications. However, it is difficult to measure spatial resolution reliably due to error factors such as noise. The aim of this study was to obtain a modulation transfer function (MTF) more accurately.Methods: A CBCT apparatus was used with small FOV. An aluminum pipe slightly tilted at an inclination ratio of 77/3 (25.7) was used as the measurement phantom. The MTF was calculated from the edge image of the phantom. The actual oversampling ratio was determined by regression analysis. The experiment was repeated 16 times and the edge-spread function (ESF) was approximated by the least-square method. Furthermore, a low-pass filter (LPF) was applied to eliminate the component at frequencies above the Nyquist frequency. Finally, the MTF was calculated from the pre-processed ESF.Results: Results showed that pre-processing reduced the noise of the ESF. The MTFs at frequencies of 1.0 and 2.0 LP/mm were 0.59 and 0.18, respectively, in air and 0.52 and 0.16, respectively, in water.Conclusion: The repeating-edge oversampling method combined with ESF pre-processing improved the accuracy of the MTF under clinically relevant conditions with a phantom.</description><subject>computed tomography</subject><subject>cone beam</subject><subject>Cone-Beam Computed Tomography</subject><subject>dental</subject><subject>Dentistry</subject><subject>Image Processing, Computer-Assisted</subject><subject>modulation transfer function</subject><subject>Phantoms, Imaging</subject><subject>Water</subject><issn>1343-4934</issn><issn>1880-4926</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kT9v2zAQxYWiRZMmmbsVHLso4T-R0lgEblIgQJd2Js7U0ZZBiSpJ2cjH6TctHbtejoe733sH4lXVZ0bvuRDyYRfStKT-ntOaSt29q65Z29Jadly9L72QovRCXlWfUtpRKrnSzcfqSgjBGGXiuvq72oNfIA9hIsERGyas1whj6cZ5ydiTHMawiTBvX0nYYyRA0gjeEzeg74-a_YAHMkxlcYBcgDXkbSmpaItp3iIZQ7_4040cYUquUG6Z7NvkMBQ84owFmDY19ht8O5RgnH2Z3FYfHPiEd-f3pvr9ffXr8bl--fn04_HbS22llLnuBbSNkraxzDbdWile_oqssVRZqjslhYbOSSGoUqh0q1XnqJWad7TXrgFxU309-c4x_FkwZTMOyaL3MGFYkuFSU8rbljcFfTihNoaUIjozx2GE-GoYNcdczDkXw6k55lIUX87my3rE_sL_D6IAqxOwSxk2eAEg5sF6vBgqYdixnI0ve7uFaHAS_wDGcaZO</recordid><startdate>20210101</startdate><enddate>20210101</enddate><creator>Ito, Motohiro</creator><creator>Hayashi, Yusuke</creator><creator>Matsumoto, Kunihito</creator><creator>Arai, Yoshinori</creator><creator>Honda, Kazuya</creator><general>Nihon University School of Dentistry</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20210101</creationdate><title>Evaluation of cone-beam computed tomography over a small field of view in a water bath based on the modulation transfer function with repeating-edge oversampling</title><author>Ito, Motohiro ; Hayashi, Yusuke ; Matsumoto, Kunihito ; Arai, Yoshinori ; Honda, Kazuya</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c444t-d3a8564c5c1c59b662267e15c06c0796437a9f433066e678769f0c47290d7f5a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>computed tomography</topic><topic>cone beam</topic><topic>Cone-Beam Computed Tomography</topic><topic>dental</topic><topic>Dentistry</topic><topic>Image Processing, Computer-Assisted</topic><topic>modulation transfer function</topic><topic>Phantoms, Imaging</topic><topic>Water</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ito, Motohiro</creatorcontrib><creatorcontrib>Hayashi, Yusuke</creatorcontrib><creatorcontrib>Matsumoto, Kunihito</creatorcontrib><creatorcontrib>Arai, Yoshinori</creatorcontrib><creatorcontrib>Honda, Kazuya</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Oral Science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ito, Motohiro</au><au>Hayashi, Yusuke</au><au>Matsumoto, Kunihito</au><au>Arai, Yoshinori</au><au>Honda, Kazuya</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of cone-beam computed tomography over a small field of view in a water bath based on the modulation transfer function with repeating-edge oversampling</atitle><jtitle>Journal of Oral Science</jtitle><addtitle>J Oral Sci</addtitle><date>2021-01-01</date><risdate>2021</risdate><volume>63</volume><issue>1</issue><spage>87</spage><epage>91</epage><pages>87-91</pages><issn>1343-4934</issn><eissn>1880-4926</eissn><abstract>Purpose: The spatial resolution of cone-beam computed tomography (CBCT) in small fields of view (FOVs) is important for clinical applications. However, it is difficult to measure spatial resolution reliably due to error factors such as noise. The aim of this study was to obtain a modulation transfer function (MTF) more accurately.Methods: A CBCT apparatus was used with small FOV. An aluminum pipe slightly tilted at an inclination ratio of 77/3 (25.7) was used as the measurement phantom. The MTF was calculated from the edge image of the phantom. The actual oversampling ratio was determined by regression analysis. The experiment was repeated 16 times and the edge-spread function (ESF) was approximated by the least-square method. Furthermore, a low-pass filter (LPF) was applied to eliminate the component at frequencies above the Nyquist frequency. Finally, the MTF was calculated from the pre-processed ESF.Results: Results showed that pre-processing reduced the noise of the ESF. The MTFs at frequencies of 1.0 and 2.0 LP/mm were 0.59 and 0.18, respectively, in air and 0.52 and 0.16, respectively, in water.Conclusion: The repeating-edge oversampling method combined with ESF pre-processing improved the accuracy of the MTF under clinically relevant conditions with a phantom.</abstract><cop>Japan</cop><pub>Nihon University School of Dentistry</pub><pmid>33311013</pmid><doi>10.2334/josnusd.20-0479</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1343-4934
ispartof Journal of Oral Science, 2021, Vol.63(1), pp.87-91
issn 1343-4934
1880-4926
language eng
recordid cdi_proquest_miscellaneous_2470028825
source J-STAGE Free; MEDLINE; Freely Accessible Japanese Titles; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects computed tomography
cone beam
Cone-Beam Computed Tomography
dental
Dentistry
Image Processing, Computer-Assisted
modulation transfer function
Phantoms, Imaging
Water
title Evaluation of cone-beam computed tomography over a small field of view in a water bath based on the modulation transfer function with repeating-edge oversampling
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T20%3A51%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20cone-beam%20computed%20tomography%20over%20a%20small%20field%20of%20view%20in%20a%20water%20bath%20based%20on%20the%20modulation%20transfer%20function%20with%20repeating-edge%20oversampling&rft.jtitle=Journal%20of%20Oral%20Science&rft.au=Ito,%20Motohiro&rft.date=2021-01-01&rft.volume=63&rft.issue=1&rft.spage=87&rft.epage=91&rft.pages=87-91&rft.issn=1343-4934&rft.eissn=1880-4926&rft_id=info:doi/10.2334/josnusd.20-0479&rft_dat=%3Cproquest_cross%3E2470028825%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2470028825&rft_id=info:pmid/33311013&rfr_iscdi=true