Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis

The purpose of this study is to analyze and compare stress distribution on bone screws and plate systems in locking and non-locking screw-plates design in lateral mandibular defects. Solid mathematical model of mandible was created by three-dimensional finite elements analysis and 25 mm length of la...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of stomatology, oral and maxillofacial surgery oral and maxillofacial surgery, 2021-09, Vol.122 (4), p.e65-e69
Hauptverfasser: Muftuoglu, G., Bayram, B., Aydin, P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e69
container_issue 4
container_start_page e65
container_title Journal of stomatology, oral and maxillofacial surgery
container_volume 122
creator Muftuoglu, G.
Bayram, B.
Aydin, P.
description The purpose of this study is to analyze and compare stress distribution on bone screws and plate systems in locking and non-locking screw-plates design in lateral mandibular defects. Solid mathematical model of mandible was created by three-dimensional finite elements analysis and 25 mm length of lateral resection (L defect) was performed on the model. Models were reconstructed with 2.4 locking and non-locking reconstruction plate system. Each masticator muscles attached to mandible were simulated as direction, attachment area and magnitude on 3D model to compare with reality. The stress formation on bone and hardware system were evaluated. The stress values on the cortical bone, plate and screw system were higher in conventional plate model than the locking system model. The highest stress values were measured in the proximal segment especially in conjunction with conventional screw system. Furthermore, the distribution of stress on the bone surface was more homogenous in the locking system. It is evident that the use of the locking system in 25 mm length lateral mandibular defects provides an additional advantage over conventional systems in reconstruction models.
doi_str_mv 10.1016/j.jormas.2020.10.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2458963325</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2468785520302627</els_id><sourcerecordid>2458963325</sourcerecordid><originalsourceid>FETCH-LOGICAL-c428t-8458ff775ce9d8e92e9599de7fa74cbc3c193d7d49dc4038eef65364ffd37d933</originalsourceid><addsrcrecordid>eNp9kEGPFCEQhYnRuJt1_4ExHL30CA1NNxcTM3HVZBMveiYMFIaxG0aK1szNny6d2TWePFG8vFcv9RHykrMdZ1y9Oe6OuSwWdz3rN2nH2PiEXPdSTd04DcPTf-Yrcot4ZIzxqVdKDs_JlRBcca70Nfm9z8vJlog50RzonN33mL5RmzxNOXWP_wIuJ6xldTU252m2FTp0BX5RPGOFhcZEN7HYmS4tHQ_rbAv1EMBVpIczDTHFChRmWCDV1mDnM0Z8QZ4FOyPcPrw35Ovd-y_7j9395w-f9u_uOyf7qXaTHKYQxnFwoP0Eugc9aO1hDHaU7uCE41r40UvtnWRiAghqEEqG4MXotRA35PVl76nkHytgNUtEB_NsE-QVTd8KtBKiH5pVXqyuZMQCwZxKXGw5G87Mht8czQW_2fBvasPfYq8eGtbDAv5v6BF2M7y9GKDd-TNCMegiJAc-Nr7V-Bz_3_AH_iubkQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2458963325</pqid></control><display><type>article</type><title>Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis</title><source>Alma/SFX Local Collection</source><creator>Muftuoglu, G. ; Bayram, B. ; Aydin, P.</creator><creatorcontrib>Muftuoglu, G. ; Bayram, B. ; Aydin, P.</creatorcontrib><description>The purpose of this study is to analyze and compare stress distribution on bone screws and plate systems in locking and non-locking screw-plates design in lateral mandibular defects. Solid mathematical model of mandible was created by three-dimensional finite elements analysis and 25 mm length of lateral resection (L defect) was performed on the model. Models were reconstructed with 2.4 locking and non-locking reconstruction plate system. Each masticator muscles attached to mandible were simulated as direction, attachment area and magnitude on 3D model to compare with reality. The stress formation on bone and hardware system were evaluated. The stress values on the cortical bone, plate and screw system were higher in conventional plate model than the locking system model. The highest stress values were measured in the proximal segment especially in conjunction with conventional screw system. Furthermore, the distribution of stress on the bone surface was more homogenous in the locking system. It is evident that the use of the locking system in 25 mm length lateral mandibular defects provides an additional advantage over conventional systems in reconstruction models.</description><identifier>ISSN: 2468-7855</identifier><identifier>EISSN: 2468-7855</identifier><identifier>DOI: 10.1016/j.jormas.2020.10.007</identifier><identifier>PMID: 33161169</identifier><language>eng</language><publisher>France: Elsevier Masson SAS</publisher><subject>Finite element analysis ; Locking plate systems ; Mandibular reconstruction</subject><ispartof>Journal of stomatology, oral and maxillofacial surgery, 2021-09, Vol.122 (4), p.e65-e69</ispartof><rights>2020 Elsevier Masson SAS</rights><rights>Copyright © 2020 Elsevier Masson SAS. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c428t-8458ff775ce9d8e92e9599de7fa74cbc3c193d7d49dc4038eef65364ffd37d933</citedby><cites>FETCH-LOGICAL-c428t-8458ff775ce9d8e92e9599de7fa74cbc3c193d7d49dc4038eef65364ffd37d933</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33161169$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Muftuoglu, G.</creatorcontrib><creatorcontrib>Bayram, B.</creatorcontrib><creatorcontrib>Aydin, P.</creatorcontrib><title>Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis</title><title>Journal of stomatology, oral and maxillofacial surgery</title><addtitle>J Stomatol Oral Maxillofac Surg</addtitle><description>The purpose of this study is to analyze and compare stress distribution on bone screws and plate systems in locking and non-locking screw-plates design in lateral mandibular defects. Solid mathematical model of mandible was created by three-dimensional finite elements analysis and 25 mm length of lateral resection (L defect) was performed on the model. Models were reconstructed with 2.4 locking and non-locking reconstruction plate system. Each masticator muscles attached to mandible were simulated as direction, attachment area and magnitude on 3D model to compare with reality. The stress formation on bone and hardware system were evaluated. The stress values on the cortical bone, plate and screw system were higher in conventional plate model than the locking system model. The highest stress values were measured in the proximal segment especially in conjunction with conventional screw system. Furthermore, the distribution of stress on the bone surface was more homogenous in the locking system. It is evident that the use of the locking system in 25 mm length lateral mandibular defects provides an additional advantage over conventional systems in reconstruction models.</description><subject>Finite element analysis</subject><subject>Locking plate systems</subject><subject>Mandibular reconstruction</subject><issn>2468-7855</issn><issn>2468-7855</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kEGPFCEQhYnRuJt1_4ExHL30CA1NNxcTM3HVZBMveiYMFIaxG0aK1szNny6d2TWePFG8vFcv9RHykrMdZ1y9Oe6OuSwWdz3rN2nH2PiEXPdSTd04DcPTf-Yrcot4ZIzxqVdKDs_JlRBcca70Nfm9z8vJlog50RzonN33mL5RmzxNOXWP_wIuJ6xldTU252m2FTp0BX5RPGOFhcZEN7HYmS4tHQ_rbAv1EMBVpIczDTHFChRmWCDV1mDnM0Z8QZ4FOyPcPrw35Ovd-y_7j9395w-f9u_uOyf7qXaTHKYQxnFwoP0Eugc9aO1hDHaU7uCE41r40UvtnWRiAghqEEqG4MXotRA35PVl76nkHytgNUtEB_NsE-QVTd8KtBKiH5pVXqyuZMQCwZxKXGw5G87Mht8czQW_2fBvasPfYq8eGtbDAv5v6BF2M7y9GKDd-TNCMegiJAc-Nr7V-Bz_3_AH_iubkQ</recordid><startdate>20210901</startdate><enddate>20210901</enddate><creator>Muftuoglu, G.</creator><creator>Bayram, B.</creator><creator>Aydin, P.</creator><general>Elsevier Masson SAS</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20210901</creationdate><title>Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis</title><author>Muftuoglu, G. ; Bayram, B. ; Aydin, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c428t-8458ff775ce9d8e92e9599de7fa74cbc3c193d7d49dc4038eef65364ffd37d933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Finite element analysis</topic><topic>Locking plate systems</topic><topic>Mandibular reconstruction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Muftuoglu, G.</creatorcontrib><creatorcontrib>Bayram, B.</creatorcontrib><creatorcontrib>Aydin, P.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of stomatology, oral and maxillofacial surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Muftuoglu, G.</au><au>Bayram, B.</au><au>Aydin, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis</atitle><jtitle>Journal of stomatology, oral and maxillofacial surgery</jtitle><addtitle>J Stomatol Oral Maxillofac Surg</addtitle><date>2021-09-01</date><risdate>2021</risdate><volume>122</volume><issue>4</issue><spage>e65</spage><epage>e69</epage><pages>e65-e69</pages><issn>2468-7855</issn><eissn>2468-7855</eissn><abstract>The purpose of this study is to analyze and compare stress distribution on bone screws and plate systems in locking and non-locking screw-plates design in lateral mandibular defects. Solid mathematical model of mandible was created by three-dimensional finite elements analysis and 25 mm length of lateral resection (L defect) was performed on the model. Models were reconstructed with 2.4 locking and non-locking reconstruction plate system. Each masticator muscles attached to mandible were simulated as direction, attachment area and magnitude on 3D model to compare with reality. The stress formation on bone and hardware system were evaluated. The stress values on the cortical bone, plate and screw system were higher in conventional plate model than the locking system model. The highest stress values were measured in the proximal segment especially in conjunction with conventional screw system. Furthermore, the distribution of stress on the bone surface was more homogenous in the locking system. It is evident that the use of the locking system in 25 mm length lateral mandibular defects provides an additional advantage over conventional systems in reconstruction models.</abstract><cop>France</cop><pub>Elsevier Masson SAS</pub><pmid>33161169</pmid><doi>10.1016/j.jormas.2020.10.007</doi></addata></record>
fulltext fulltext
identifier ISSN: 2468-7855
ispartof Journal of stomatology, oral and maxillofacial surgery, 2021-09, Vol.122 (4), p.e65-e69
issn 2468-7855
2468-7855
language eng
recordid cdi_proquest_miscellaneous_2458963325
source Alma/SFX Local Collection
subjects Finite element analysis
Locking plate systems
Mandibular reconstruction
title Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T22%3A40%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20locking%20and%20non-locking%20reconstruction%20plate-screw%20system%20in%20lateral%20mandibular%20defects%20by%20finite%20element%20analysis&rft.jtitle=Journal%20of%20stomatology,%20oral%20and%20maxillofacial%20surgery&rft.au=Muftuoglu,%20G.&rft.date=2021-09-01&rft.volume=122&rft.issue=4&rft.spage=e65&rft.epage=e69&rft.pages=e65-e69&rft.issn=2468-7855&rft.eissn=2468-7855&rft_id=info:doi/10.1016/j.jormas.2020.10.007&rft_dat=%3Cproquest_cross%3E2458963325%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2458963325&rft_id=info:pmid/33161169&rft_els_id=S2468785520302627&rfr_iscdi=true