Radiographic measurements of the normal distal radius: reliability of computer-aided CT versus physicians’ radiograph interpretation

We examined the reliability of a computer-aided cone-beam CT analysis of radiographic parameters of 50 normal distal radii and compared it with interobserver agreement of measurements made by three groups of physicians on two-dimensional plain radiographs. The intra-rater reliability of the computer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hand surgery, European volume European volume, 2021-02, Vol.46 (2), p.176-183
Hauptverfasser: Suojärvi, Nora, Lindfors, Nina, Höglund, Theresa, Sippo, Robert, Waris, Eero
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 183
container_issue 2
container_start_page 176
container_title The Journal of hand surgery, European volume
container_volume 46
creator Suojärvi, Nora
Lindfors, Nina
Höglund, Theresa
Sippo, Robert
Waris, Eero
description We examined the reliability of a computer-aided cone-beam CT analysis of radiographic parameters of 50 normal distal radii and compared it with interobserver agreement of measurements made by three groups of physicians on two-dimensional plain radiographs. The intra-rater reliability of the computer-aided analysis was evaluated on 33 wrists imaged twice by cone-beam CT. The longitudinal axis, anterior tilt, radial inclination and ulnar variance were measured. The reliability of computer-aided analysis was excellent (intraclass correlation coefficient (ICC) 0.94–0.96) while the interobserver agreement of two-dimensional radiograph interpretation was good (ulnar variance, ICC 0.80–0.84) to poor (anterior tilt and radial inclination, ICC 0.20–0.42). We conclude that computer-aided cone-beam CT analysis was a reliable tool for radiographic parameter determination, whereas physicians demonstrated substantial variability especially in interpreting the angular parameters.
doi_str_mv 10.1177/1753193420968399
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2457967948</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1753193420968399</sage_id><sourcerecordid>2457967948</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-f2c5e515c3a9fdf094b8b4811b6090d50cb7584bd9f35335e6e35ae827b33b903</originalsourceid><addsrcrecordid>eNp1kM1O3DAUha2qqEwH9qyQl92kteM4jtmhEf2RkJDQsI5s52bGKImDr1Npdl31HXg9noQMQ1lUYnUX5zvn6hxCzjj7yrlS37iSgmtR5EyXldD6A1nkrBBZmVf6I1ns5WyvH5PPiPeMyUrz8hM5FoIXFWdqQf7emsaHTTTj1jvag8EpQg9DQhpamrZAhxB709HGY5pPnPEJL2iEzhvrO592e9CFfpwSxMz4Bhq6WtPfEHFCOm536J03Az79eXxxH55RP8z4GCGZ5MNwQo5a0yGcvt4luft-tV79zK5vfvxaXV5nTiidsjZ3EiSXThjdNi3Tha3s3ITbkmnWSOasklVhG90KKYSEEoQ0UOXKCmE1E0vy5ZA7xvAwAaa69-ig68wAYcI6L6TSpdJFNaPsgLoYECO09Rh9b-Ku5qzer1__v_5sOX9Nn2wPzZvh39wzkB0ANBuo78MUh7nt-4HPIWmQaQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2457967948</pqid></control><display><type>article</type><title>Radiographic measurements of the normal distal radius: reliability of computer-aided CT versus physicians’ radiograph interpretation</title><source>SAGE Complete A-Z List</source><source>Alma/SFX Local Collection</source><creator>Suojärvi, Nora ; Lindfors, Nina ; Höglund, Theresa ; Sippo, Robert ; Waris, Eero</creator><creatorcontrib>Suojärvi, Nora ; Lindfors, Nina ; Höglund, Theresa ; Sippo, Robert ; Waris, Eero</creatorcontrib><description>We examined the reliability of a computer-aided cone-beam CT analysis of radiographic parameters of 50 normal distal radii and compared it with interobserver agreement of measurements made by three groups of physicians on two-dimensional plain radiographs. The intra-rater reliability of the computer-aided analysis was evaluated on 33 wrists imaged twice by cone-beam CT. The longitudinal axis, anterior tilt, radial inclination and ulnar variance were measured. The reliability of computer-aided analysis was excellent (intraclass correlation coefficient (ICC) 0.94–0.96) while the interobserver agreement of two-dimensional radiograph interpretation was good (ulnar variance, ICC 0.80–0.84) to poor (anterior tilt and radial inclination, ICC 0.20–0.42). We conclude that computer-aided cone-beam CT analysis was a reliable tool for radiographic parameter determination, whereas physicians demonstrated substantial variability especially in interpreting the angular parameters.</description><identifier>ISSN: 1753-1934</identifier><identifier>EISSN: 2043-6289</identifier><identifier>DOI: 10.1177/1753193420968399</identifier><identifier>PMID: 33148107</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>The Journal of hand surgery, European volume, 2021-02, Vol.46 (2), p.176-183</ispartof><rights>The Author(s) 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-f2c5e515c3a9fdf094b8b4811b6090d50cb7584bd9f35335e6e35ae827b33b903</citedby><cites>FETCH-LOGICAL-c379t-f2c5e515c3a9fdf094b8b4811b6090d50cb7584bd9f35335e6e35ae827b33b903</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1753193420968399$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1753193420968399$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,778,782,21806,27911,27912,43608,43609</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33148107$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Suojärvi, Nora</creatorcontrib><creatorcontrib>Lindfors, Nina</creatorcontrib><creatorcontrib>Höglund, Theresa</creatorcontrib><creatorcontrib>Sippo, Robert</creatorcontrib><creatorcontrib>Waris, Eero</creatorcontrib><title>Radiographic measurements of the normal distal radius: reliability of computer-aided CT versus physicians’ radiograph interpretation</title><title>The Journal of hand surgery, European volume</title><addtitle>J Hand Surg Eur Vol</addtitle><description>We examined the reliability of a computer-aided cone-beam CT analysis of radiographic parameters of 50 normal distal radii and compared it with interobserver agreement of measurements made by three groups of physicians on two-dimensional plain radiographs. The intra-rater reliability of the computer-aided analysis was evaluated on 33 wrists imaged twice by cone-beam CT. The longitudinal axis, anterior tilt, radial inclination and ulnar variance were measured. The reliability of computer-aided analysis was excellent (intraclass correlation coefficient (ICC) 0.94–0.96) while the interobserver agreement of two-dimensional radiograph interpretation was good (ulnar variance, ICC 0.80–0.84) to poor (anterior tilt and radial inclination, ICC 0.20–0.42). We conclude that computer-aided cone-beam CT analysis was a reliable tool for radiographic parameter determination, whereas physicians demonstrated substantial variability especially in interpreting the angular parameters.</description><issn>1753-1934</issn><issn>2043-6289</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1kM1O3DAUha2qqEwH9qyQl92kteM4jtmhEf2RkJDQsI5s52bGKImDr1Npdl31HXg9noQMQ1lUYnUX5zvn6hxCzjj7yrlS37iSgmtR5EyXldD6A1nkrBBZmVf6I1ns5WyvH5PPiPeMyUrz8hM5FoIXFWdqQf7emsaHTTTj1jvag8EpQg9DQhpamrZAhxB709HGY5pPnPEJL2iEzhvrO592e9CFfpwSxMz4Bhq6WtPfEHFCOm536J03Az79eXxxH55RP8z4GCGZ5MNwQo5a0yGcvt4luft-tV79zK5vfvxaXV5nTiidsjZ3EiSXThjdNi3Tha3s3ITbkmnWSOasklVhG90KKYSEEoQ0UOXKCmE1E0vy5ZA7xvAwAaa69-ig68wAYcI6L6TSpdJFNaPsgLoYECO09Rh9b-Ku5qzer1__v_5sOX9Nn2wPzZvh39wzkB0ANBuo78MUh7nt-4HPIWmQaQ</recordid><startdate>202102</startdate><enddate>202102</enddate><creator>Suojärvi, Nora</creator><creator>Lindfors, Nina</creator><creator>Höglund, Theresa</creator><creator>Sippo, Robert</creator><creator>Waris, Eero</creator><general>SAGE Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202102</creationdate><title>Radiographic measurements of the normal distal radius: reliability of computer-aided CT versus physicians’ radiograph interpretation</title><author>Suojärvi, Nora ; Lindfors, Nina ; Höglund, Theresa ; Sippo, Robert ; Waris, Eero</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-f2c5e515c3a9fdf094b8b4811b6090d50cb7584bd9f35335e6e35ae827b33b903</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Suojärvi, Nora</creatorcontrib><creatorcontrib>Lindfors, Nina</creatorcontrib><creatorcontrib>Höglund, Theresa</creatorcontrib><creatorcontrib>Sippo, Robert</creatorcontrib><creatorcontrib>Waris, Eero</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery, European volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Suojärvi, Nora</au><au>Lindfors, Nina</au><au>Höglund, Theresa</au><au>Sippo, Robert</au><au>Waris, Eero</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiographic measurements of the normal distal radius: reliability of computer-aided CT versus physicians’ radiograph interpretation</atitle><jtitle>The Journal of hand surgery, European volume</jtitle><addtitle>J Hand Surg Eur Vol</addtitle><date>2021-02</date><risdate>2021</risdate><volume>46</volume><issue>2</issue><spage>176</spage><epage>183</epage><pages>176-183</pages><issn>1753-1934</issn><eissn>2043-6289</eissn><abstract>We examined the reliability of a computer-aided cone-beam CT analysis of radiographic parameters of 50 normal distal radii and compared it with interobserver agreement of measurements made by three groups of physicians on two-dimensional plain radiographs. The intra-rater reliability of the computer-aided analysis was evaluated on 33 wrists imaged twice by cone-beam CT. The longitudinal axis, anterior tilt, radial inclination and ulnar variance were measured. The reliability of computer-aided analysis was excellent (intraclass correlation coefficient (ICC) 0.94–0.96) while the interobserver agreement of two-dimensional radiograph interpretation was good (ulnar variance, ICC 0.80–0.84) to poor (anterior tilt and radial inclination, ICC 0.20–0.42). We conclude that computer-aided cone-beam CT analysis was a reliable tool for radiographic parameter determination, whereas physicians demonstrated substantial variability especially in interpreting the angular parameters.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>33148107</pmid><doi>10.1177/1753193420968399</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1753-1934
ispartof The Journal of hand surgery, European volume, 2021-02, Vol.46 (2), p.176-183
issn 1753-1934
2043-6289
language eng
recordid cdi_proquest_miscellaneous_2457967948
source SAGE Complete A-Z List; Alma/SFX Local Collection
title Radiographic measurements of the normal distal radius: reliability of computer-aided CT versus physicians’ radiograph interpretation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T12%3A09%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiographic%20measurements%20of%20the%20normal%20distal%20radius:%20reliability%20of%20computer-aided%20CT%20versus%20physicians%E2%80%99%20radiograph%20interpretation&rft.jtitle=The%20Journal%20of%20hand%20surgery,%20European%20volume&rft.au=Suoj%C3%A4rvi,%20Nora&rft.date=2021-02&rft.volume=46&rft.issue=2&rft.spage=176&rft.epage=183&rft.pages=176-183&rft.issn=1753-1934&rft.eissn=2043-6289&rft_id=info:doi/10.1177/1753193420968399&rft_dat=%3Cproquest_cross%3E2457967948%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2457967948&rft_id=info:pmid/33148107&rft_sage_id=10.1177_1753193420968399&rfr_iscdi=true