Micro–computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments
The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of c...
Gespeichert in:
Veröffentlicht in: | Journal of endodontics 2021-02, Vol.47 (2), p.309-314 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 314 |
---|---|
container_issue | 2 |
container_start_page | 309 |
container_title | Journal of endodontics |
container_volume | 47 |
creator | Miguéns-Vila, Ramón Martín-Biedma, Benjamín De-Deus, Gustavo Belladonna, Felipe G. Peña-López, Alejandro Castelo-Baz, Pablo |
description | The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro–computed tomographic analysis.
Twenty-four human mandibular molars with curved roots were scanned in a micro–computed tomographic device using an isotropic resolution of 6.78 μm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre- and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks.
Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems.
Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks. |
doi_str_mv | 10.1016/j.joen.2020.10.014 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2454134856</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0099239920307767</els_id><sourcerecordid>2454134856</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-23fc9948a468e9adce3dd17c663c933d3898d2b093caed4fdc7d6dfbf79618503</originalsourceid><addsrcrecordid>eNp9kc9uEzEQxi1ERUPhBTggHzk0qb3ef5a4oFDSSG2DUBBHy7FnicOuvdjeFG68Aw_R9-JJ8JJQbpxGM_p932jmQ-gFJTNKaHmxm-0c2FlGsnEwIzR_hCa0ruopK4r8MZoQwvk0Y5yfoqch7AihFWPVE3TKGOEl5WyC7m-M8u7Xj5_Kdf0QQeO169xnL_utUfhyL9tBRuMsdg1-CzYaK1v8R6O8VF8Clk0Ej9976KV_IOeD3yerD85FPJdJEvCdiduEubXsE79wrT7Hn-QeVhaOnbT6H3AL3yJe2hD90KW14Rk6aZINPD_WM_Tx3eV6fjW9Xi2W8zfXU8WKMqZjG8V5Xsu8rIFLrYBpTStVlkxxxjSrea2zDeFMSdB5o1WlS91smir9oy4IO0OvDr69d18HCFF0JihoW2nBDUFkeZFTltdFmdDsgKZnhOChEb03nfTfBSViDEjsxBiQGAMaZymgJHp59B82HegHyd9EEvD6AEC6cm_Ai6AMWAXaeFBRaGf-5_8bey-mEg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2454134856</pqid></control><display><type>article</type><title>Micro–computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Miguéns-Vila, Ramón ; Martín-Biedma, Benjamín ; De-Deus, Gustavo ; Belladonna, Felipe G. ; Peña-López, Alejandro ; Castelo-Baz, Pablo</creator><creatorcontrib>Miguéns-Vila, Ramón ; Martín-Biedma, Benjamín ; De-Deus, Gustavo ; Belladonna, Felipe G. ; Peña-López, Alejandro ; Castelo-Baz, Pablo</creatorcontrib><description>The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro–computed tomographic analysis.
Twenty-four human mandibular molars with curved roots were scanned in a micro–computed tomographic device using an isotropic resolution of 6.78 μm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre- and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks.
Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems.
Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks.</description><identifier>ISSN: 0099-2399</identifier><identifier>EISSN: 1878-3554</identifier><identifier>DOI: 10.1016/j.joen.2020.10.014</identifier><identifier>PMID: 33096193</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Cross-Sectional Studies ; Curved root canals ; Dental Pulp Cavity - diagnostic imaging ; Dentin - diagnostic imaging ; dentinal defects ; Dentistry ; Gold ; Humans ; microcracks ; micro–computed tomography ; Root Canal Preparation ; X-Ray Microtomography</subject><ispartof>Journal of endodontics, 2021-02, Vol.47 (2), p.309-314</ispartof><rights>2020 American Association of Endodontists</rights><rights>Copyright © 2020 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-23fc9948a468e9adce3dd17c663c933d3898d2b093caed4fdc7d6dfbf79618503</citedby><cites>FETCH-LOGICAL-c356t-23fc9948a468e9adce3dd17c663c933d3898d2b093caed4fdc7d6dfbf79618503</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0099239920307767$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33096193$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miguéns-Vila, Ramón</creatorcontrib><creatorcontrib>Martín-Biedma, Benjamín</creatorcontrib><creatorcontrib>De-Deus, Gustavo</creatorcontrib><creatorcontrib>Belladonna, Felipe G.</creatorcontrib><creatorcontrib>Peña-López, Alejandro</creatorcontrib><creatorcontrib>Castelo-Baz, Pablo</creatorcontrib><title>Micro–computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments</title><title>Journal of endodontics</title><addtitle>J Endod</addtitle><description>The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro–computed tomographic analysis.
Twenty-four human mandibular molars with curved roots were scanned in a micro–computed tomographic device using an isotropic resolution of 6.78 μm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre- and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks.
Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems.
Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks.</description><subject>Cross-Sectional Studies</subject><subject>Curved root canals</subject><subject>Dental Pulp Cavity - diagnostic imaging</subject><subject>Dentin - diagnostic imaging</subject><subject>dentinal defects</subject><subject>Dentistry</subject><subject>Gold</subject><subject>Humans</subject><subject>microcracks</subject><subject>micro–computed tomography</subject><subject>Root Canal Preparation</subject><subject>X-Ray Microtomography</subject><issn>0099-2399</issn><issn>1878-3554</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc9uEzEQxi1ERUPhBTggHzk0qb3ef5a4oFDSSG2DUBBHy7FnicOuvdjeFG68Aw_R9-JJ8JJQbpxGM_p932jmQ-gFJTNKaHmxm-0c2FlGsnEwIzR_hCa0ruopK4r8MZoQwvk0Y5yfoqch7AihFWPVE3TKGOEl5WyC7m-M8u7Xj5_Kdf0QQeO169xnL_utUfhyL9tBRuMsdg1-CzYaK1v8R6O8VF8Clk0Ej9976KV_IOeD3yerD85FPJdJEvCdiduEubXsE79wrT7Hn-QeVhaOnbT6H3AL3yJe2hD90KW14Rk6aZINPD_WM_Tx3eV6fjW9Xi2W8zfXU8WKMqZjG8V5Xsu8rIFLrYBpTStVlkxxxjSrea2zDeFMSdB5o1WlS91smir9oy4IO0OvDr69d18HCFF0JihoW2nBDUFkeZFTltdFmdDsgKZnhOChEb03nfTfBSViDEjsxBiQGAMaZymgJHp59B82HegHyd9EEvD6AEC6cm_Ai6AMWAXaeFBRaGf-5_8bey-mEg</recordid><startdate>202102</startdate><enddate>202102</enddate><creator>Miguéns-Vila, Ramón</creator><creator>Martín-Biedma, Benjamín</creator><creator>De-Deus, Gustavo</creator><creator>Belladonna, Felipe G.</creator><creator>Peña-López, Alejandro</creator><creator>Castelo-Baz, Pablo</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202102</creationdate><title>Micro–computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments</title><author>Miguéns-Vila, Ramón ; Martín-Biedma, Benjamín ; De-Deus, Gustavo ; Belladonna, Felipe G. ; Peña-López, Alejandro ; Castelo-Baz, Pablo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-23fc9948a468e9adce3dd17c663c933d3898d2b093caed4fdc7d6dfbf79618503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Cross-Sectional Studies</topic><topic>Curved root canals</topic><topic>Dental Pulp Cavity - diagnostic imaging</topic><topic>Dentin - diagnostic imaging</topic><topic>dentinal defects</topic><topic>Dentistry</topic><topic>Gold</topic><topic>Humans</topic><topic>microcracks</topic><topic>micro–computed tomography</topic><topic>Root Canal Preparation</topic><topic>X-Ray Microtomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miguéns-Vila, Ramón</creatorcontrib><creatorcontrib>Martín-Biedma, Benjamín</creatorcontrib><creatorcontrib>De-Deus, Gustavo</creatorcontrib><creatorcontrib>Belladonna, Felipe G.</creatorcontrib><creatorcontrib>Peña-López, Alejandro</creatorcontrib><creatorcontrib>Castelo-Baz, Pablo</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of endodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miguéns-Vila, Ramón</au><au>Martín-Biedma, Benjamín</au><au>De-Deus, Gustavo</au><au>Belladonna, Felipe G.</au><au>Peña-López, Alejandro</au><au>Castelo-Baz, Pablo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Micro–computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments</atitle><jtitle>Journal of endodontics</jtitle><addtitle>J Endod</addtitle><date>2021-02</date><risdate>2021</risdate><volume>47</volume><issue>2</issue><spage>309</spage><epage>314</epage><pages>309-314</pages><issn>0099-2399</issn><eissn>1878-3554</eissn><abstract>The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro–computed tomographic analysis.
Twenty-four human mandibular molars with curved roots were scanned in a micro–computed tomographic device using an isotropic resolution of 6.78 μm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre- and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks.
Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems.
Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>33096193</pmid><doi>10.1016/j.joen.2020.10.014</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0099-2399 |
ispartof | Journal of endodontics, 2021-02, Vol.47 (2), p.309-314 |
issn | 0099-2399 1878-3554 |
language | eng |
recordid | cdi_proquest_miscellaneous_2454134856 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Cross-Sectional Studies Curved root canals Dental Pulp Cavity - diagnostic imaging Dentin - diagnostic imaging dentinal defects Dentistry Gold Humans microcracks micro–computed tomography Root Canal Preparation X-Ray Microtomography |
title | Micro–computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T08%3A15%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Micro%E2%80%93computed%20Tomographic%20Evaluation%20of%20Dentinal%20Microcracks%20after%20Preparation%20of%20Curved%20Root%20Canals%20with%20ProTaper%20Gold,%20WaveOne%20Gold,%20and%20ProTaper%20Next%20Instruments&rft.jtitle=Journal%20of%20endodontics&rft.au=Migu%C3%A9ns-Vila,%20Ram%C3%B3n&rft.date=2021-02&rft.volume=47&rft.issue=2&rft.spage=309&rft.epage=314&rft.pages=309-314&rft.issn=0099-2399&rft.eissn=1878-3554&rft_id=info:doi/10.1016/j.joen.2020.10.014&rft_dat=%3Cproquest_cross%3E2454134856%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2454134856&rft_id=info:pmid/33096193&rft_els_id=S0099239920307767&rfr_iscdi=true |