Preconcentration of noble metals on alumina prior to analysis by inductively coupled plasma mass spectrometry: Application to geological samples

A preconcentration method for the determination of noble metals (Ag, Au, Ir, Os, Pd, Pt, Re, Rh, Ru) was developed using alumina as a sorbent. The method involves an off-line preconcentration analytical procedure: the formation of chloro-complexes of these elements with HCl, loading of the chloro-co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2020-11, Vol.1136, p.151-156
Hauptverfasser: Asfaw, Alemayehu, MacFarlane, William R., Beauchemin, Diane
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 156
container_issue
container_start_page 151
container_title Analytica chimica acta
container_volume 1136
creator Asfaw, Alemayehu
MacFarlane, William R.
Beauchemin, Diane
description A preconcentration method for the determination of noble metals (Ag, Au, Ir, Os, Pd, Pt, Re, Rh, Ru) was developed using alumina as a sorbent. The method involves an off-line preconcentration analytical procedure: the formation of chloro-complexes of these elements with HCl, loading of the chloro-complexes on alumina followed by elution of analytes and analysis by inductively coupled plasma mass spectrometry. The effects of HCl/HNO3 concentration in the sample digest, mass of alumina, and concentration of eluents (HCl and HNO3)/thiourea were studied using multivariate experimental designs. Using 2 M HCl as eluent, detection limits were improved by a factor of 10–20 for Ag, Ir, Os, Pd, Pt, and Ru, and 3–5 for Re and Rh compared to those achieved by direct nebulization (i.e. without preconcentration). Accuracy was verified through analysis of CDN-PGMS-19 ore reference material. Using 2 M HCl for elution, the results for Ag, Pd and Pt agreed with the reference values obtained based on aqua regia digestion (which does not achieve total dissolution). For the determination of Au, evaporation of HNO3 and elution with thiourea were required. [Display omitted] •Acidic alumina can retain Ag, Au, Ir, Os, Pd, Pt, Re, Rh, and Ru.•Elution with 2 M HCl improved detection limits 10–20 fold for Ag, Ir, Os, Pd, Pt, and Ru.•Elution with 2 M HCl improved detection limits 3–5 fold for Re and Rh.•The determination of Au requires evaporation of HNO3 from digests.•The determination of Au requires that 3% thiourea be present in the eluent.
doi_str_mv 10.1016/j.aca.2020.09.046
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2452981959</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000326702030979X</els_id><sourcerecordid>2452981959</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-1ffbd60ad63b04c0b306e932aff48215ce8c838a02c10eddc45b267a67bd6cf83</originalsourceid><addsrcrecordid>eNp9kM9q3DAQh0Vpods0D5Cbjr3YGUler92eQug_CLSH9izG8jhokS1XIwf8Fn3kKmzPOQ0zzPcb5hPiRkGtQLW35xod1ho01NDX0LSvxEF1J1M1RjevxQEATKXbE7wV75jPpdUKmoP4-zORi4ujJSfMPi4yTnKJQyA5U8bAsowwbLNfUK7JxyRzlLhg2NmzHHbpl3Fz2T9R2KWL2xpolGtAnlHOyCx5JZdTLGlp_yjv1jV4d7lUgh4phvhYBkEyzoXl9-LNVM7S9f96JX5_-fzr_lv18OPr9_u7h8oZA7lS0zSMLeDYmgEaB4OBlnqjcZqaTqujo851pkPQTgGNo2uOQ3kf21PB3NSZK_Hhkrum-Gcjznb27CgEXChubHVz1H2n-mNfVtVl1aXInGiyRcSMabcK7LN9e7bFvn22b6G3xX5hPl0YKj88eUqWnafiefRFeLZj9C_Q_wCxlpF2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2452981959</pqid></control><display><type>article</type><title>Preconcentration of noble metals on alumina prior to analysis by inductively coupled plasma mass spectrometry: Application to geological samples</title><source>Access via ScienceDirect (Elsevier)</source><creator>Asfaw, Alemayehu ; MacFarlane, William R. ; Beauchemin, Diane</creator><creatorcontrib>Asfaw, Alemayehu ; MacFarlane, William R. ; Beauchemin, Diane</creatorcontrib><description>A preconcentration method for the determination of noble metals (Ag, Au, Ir, Os, Pd, Pt, Re, Rh, Ru) was developed using alumina as a sorbent. The method involves an off-line preconcentration analytical procedure: the formation of chloro-complexes of these elements with HCl, loading of the chloro-complexes on alumina followed by elution of analytes and analysis by inductively coupled plasma mass spectrometry. The effects of HCl/HNO3 concentration in the sample digest, mass of alumina, and concentration of eluents (HCl and HNO3)/thiourea were studied using multivariate experimental designs. Using 2 M HCl as eluent, detection limits were improved by a factor of 10–20 for Ag, Ir, Os, Pd, Pt, and Ru, and 3–5 for Re and Rh compared to those achieved by direct nebulization (i.e. without preconcentration). Accuracy was verified through analysis of CDN-PGMS-19 ore reference material. Using 2 M HCl for elution, the results for Ag, Pd and Pt agreed with the reference values obtained based on aqua regia digestion (which does not achieve total dissolution). For the determination of Au, evaporation of HNO3 and elution with thiourea were required. [Display omitted] •Acidic alumina can retain Ag, Au, Ir, Os, Pd, Pt, Re, Rh, and Ru.•Elution with 2 M HCl improved detection limits 10–20 fold for Ag, Ir, Os, Pd, Pt, and Ru.•Elution with 2 M HCl improved detection limits 3–5 fold for Re and Rh.•The determination of Au requires evaporation of HNO3 from digests.•The determination of Au requires that 3% thiourea be present in the eluent.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2020.09.046</identifier><language>eng</language><publisher>Elsevier B.V</publisher><ispartof>Analytica chimica acta, 2020-11, Vol.1136, p.151-156</ispartof><rights>2020 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-1ffbd60ad63b04c0b306e932aff48215ce8c838a02c10eddc45b267a67bd6cf83</citedby><cites>FETCH-LOGICAL-c330t-1ffbd60ad63b04c0b306e932aff48215ce8c838a02c10eddc45b267a67bd6cf83</cites><orcidid>0000-0001-9631-1812</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.aca.2020.09.046$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Asfaw, Alemayehu</creatorcontrib><creatorcontrib>MacFarlane, William R.</creatorcontrib><creatorcontrib>Beauchemin, Diane</creatorcontrib><title>Preconcentration of noble metals on alumina prior to analysis by inductively coupled plasma mass spectrometry: Application to geological samples</title><title>Analytica chimica acta</title><description>A preconcentration method for the determination of noble metals (Ag, Au, Ir, Os, Pd, Pt, Re, Rh, Ru) was developed using alumina as a sorbent. The method involves an off-line preconcentration analytical procedure: the formation of chloro-complexes of these elements with HCl, loading of the chloro-complexes on alumina followed by elution of analytes and analysis by inductively coupled plasma mass spectrometry. The effects of HCl/HNO3 concentration in the sample digest, mass of alumina, and concentration of eluents (HCl and HNO3)/thiourea were studied using multivariate experimental designs. Using 2 M HCl as eluent, detection limits were improved by a factor of 10–20 for Ag, Ir, Os, Pd, Pt, and Ru, and 3–5 for Re and Rh compared to those achieved by direct nebulization (i.e. without preconcentration). Accuracy was verified through analysis of CDN-PGMS-19 ore reference material. Using 2 M HCl for elution, the results for Ag, Pd and Pt agreed with the reference values obtained based on aqua regia digestion (which does not achieve total dissolution). For the determination of Au, evaporation of HNO3 and elution with thiourea were required. [Display omitted] •Acidic alumina can retain Ag, Au, Ir, Os, Pd, Pt, Re, Rh, and Ru.•Elution with 2 M HCl improved detection limits 10–20 fold for Ag, Ir, Os, Pd, Pt, and Ru.•Elution with 2 M HCl improved detection limits 3–5 fold for Re and Rh.•The determination of Au requires evaporation of HNO3 from digests.•The determination of Au requires that 3% thiourea be present in the eluent.</description><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kM9q3DAQh0Vpods0D5Cbjr3YGUler92eQug_CLSH9izG8jhokS1XIwf8Fn3kKmzPOQ0zzPcb5hPiRkGtQLW35xod1ho01NDX0LSvxEF1J1M1RjevxQEATKXbE7wV75jPpdUKmoP4-zORi4ujJSfMPi4yTnKJQyA5U8bAsowwbLNfUK7JxyRzlLhg2NmzHHbpl3Fz2T9R2KWL2xpolGtAnlHOyCx5JZdTLGlp_yjv1jV4d7lUgh4phvhYBkEyzoXl9-LNVM7S9f96JX5_-fzr_lv18OPr9_u7h8oZA7lS0zSMLeDYmgEaB4OBlnqjcZqaTqujo851pkPQTgGNo2uOQ3kf21PB3NSZK_Hhkrum-Gcjznb27CgEXChubHVz1H2n-mNfVtVl1aXInGiyRcSMabcK7LN9e7bFvn22b6G3xX5hPl0YKj88eUqWnafiefRFeLZj9C_Q_wCxlpF2</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Asfaw, Alemayehu</creator><creator>MacFarlane, William R.</creator><creator>Beauchemin, Diane</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-9631-1812</orcidid></search><sort><creationdate>20201101</creationdate><title>Preconcentration of noble metals on alumina prior to analysis by inductively coupled plasma mass spectrometry: Application to geological samples</title><author>Asfaw, Alemayehu ; MacFarlane, William R. ; Beauchemin, Diane</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-1ffbd60ad63b04c0b306e932aff48215ce8c838a02c10eddc45b267a67bd6cf83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Asfaw, Alemayehu</creatorcontrib><creatorcontrib>MacFarlane, William R.</creatorcontrib><creatorcontrib>Beauchemin, Diane</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Asfaw, Alemayehu</au><au>MacFarlane, William R.</au><au>Beauchemin, Diane</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Preconcentration of noble metals on alumina prior to analysis by inductively coupled plasma mass spectrometry: Application to geological samples</atitle><jtitle>Analytica chimica acta</jtitle><date>2020-11-01</date><risdate>2020</risdate><volume>1136</volume><spage>151</spage><epage>156</epage><pages>151-156</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><abstract>A preconcentration method for the determination of noble metals (Ag, Au, Ir, Os, Pd, Pt, Re, Rh, Ru) was developed using alumina as a sorbent. The method involves an off-line preconcentration analytical procedure: the formation of chloro-complexes of these elements with HCl, loading of the chloro-complexes on alumina followed by elution of analytes and analysis by inductively coupled plasma mass spectrometry. The effects of HCl/HNO3 concentration in the sample digest, mass of alumina, and concentration of eluents (HCl and HNO3)/thiourea were studied using multivariate experimental designs. Using 2 M HCl as eluent, detection limits were improved by a factor of 10–20 for Ag, Ir, Os, Pd, Pt, and Ru, and 3–5 for Re and Rh compared to those achieved by direct nebulization (i.e. without preconcentration). Accuracy was verified through analysis of CDN-PGMS-19 ore reference material. Using 2 M HCl for elution, the results for Ag, Pd and Pt agreed with the reference values obtained based on aqua regia digestion (which does not achieve total dissolution). For the determination of Au, evaporation of HNO3 and elution with thiourea were required. [Display omitted] •Acidic alumina can retain Ag, Au, Ir, Os, Pd, Pt, Re, Rh, and Ru.•Elution with 2 M HCl improved detection limits 10–20 fold for Ag, Ir, Os, Pd, Pt, and Ru.•Elution with 2 M HCl improved detection limits 3–5 fold for Re and Rh.•The determination of Au requires evaporation of HNO3 from digests.•The determination of Au requires that 3% thiourea be present in the eluent.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.aca.2020.09.046</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0001-9631-1812</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2020-11, Vol.1136, p.151-156
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_2452981959
source Access via ScienceDirect (Elsevier)
title Preconcentration of noble metals on alumina prior to analysis by inductively coupled plasma mass spectrometry: Application to geological samples
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T00%3A10%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Preconcentration%20of%20noble%20metals%20on%20alumina%20prior%20to%20analysis%20by%20inductively%20coupled%20plasma%20mass%20spectrometry:%20Application%20to%20geological%20samples&rft.jtitle=Analytica%20chimica%20acta&rft.au=Asfaw,%20Alemayehu&rft.date=2020-11-01&rft.volume=1136&rft.spage=151&rft.epage=156&rft.pages=151-156&rft.issn=0003-2670&rft.eissn=1873-4324&rft_id=info:doi/10.1016/j.aca.2020.09.046&rft_dat=%3Cproquest_cross%3E2452981959%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2452981959&rft_id=info:pmid/&rft_els_id=S000326702030979X&rfr_iscdi=true