The impact of low pressure pneumoperitoneum in robotic assisted radical prostatectomy: a prospective, randomized, double blinded trial
Background Robotic surgery has revolutionized postoperative outcomes across surgical specialties. However, the use of pneumoperitoneum comes with known risks given the change in physiological parameters that accompany its utilization. A recent internal review found a 7% decrease in postoperative ile...
Gespeichert in:
Veröffentlicht in: | World journal of urology 2021-07, Vol.39 (7), p.2469-2474 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2474 |
---|---|
container_issue | 7 |
container_start_page | 2469 |
container_title | World journal of urology |
container_volume | 39 |
creator | Rohloff, Matthew Peifer, Greggory Shakuri-Rad, Jaschar Maatman, Thomas J. |
description | Background
Robotic surgery has revolutionized postoperative outcomes across surgical specialties. However, the use of pneumoperitoneum comes with known risks given the change in physiological parameters that accompany its utilization. A recent internal review found a 7% decrease in postoperative ileus rates when utilizing a pneumoperitoneum of 12 mmHg over the standard 15 mmHg in robotic assisted radical prostatectomies (RARP).
Objective
The purpose of this study is to prospectively evaluate the utility of lower pressure pneumoperitoneum by comparing 8 mmHg and 12 mmHg during RARP.
Design, setting and partcipants
Patients were randomly assigned to undergo robotic assisted radical prostatectomy at a pneumoperitoneum pressure of 12 mmHg or 8 mmHg.
Outcome measurements and statistical analysis
The primary outcome was development of postoperative ileus and secondary outcomes were length of operation, estimated blood loss and positive surgical margin status.
Results and limitations
A total of 201 patients were analyzed; 96 patients at 8 mmHg and 105 patients at 12 mmHg. The groups were adequately matched as there were no differences between demographic parameters or medical comorbidities. There was a decrease in postoperative ileus rates with lower pneumoperitoneum pressures; 2% at 8 mmHg and 4.8% at 12 mmHg. There were no clinically significant differences in estimated blood loss, total length of operative time and positive margin status.
Conclusions
Lower pressure pneumoperitoneum during robotic assisted radical prostatectomy is non-inferior to higher pressure pneumoperitoneum levels and the experienced surgeon may safely perform this operation at 8 mmHg to take advantage of the proposed benefits. |
doi_str_mv | 10.1007/s00345-020-03486-4 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2451853960</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2451853960</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-51f02eb9997628f0afc5d2ac6f117a4e392178a8eeb5949c474a17f329a2b37b3</originalsourceid><addsrcrecordid>eNp9kc9OFjEUxRsjkU_0BVyQJm5cMNL_nbIzBJSEhA2sm07njpbMTIe2g8EH4LkpfCgJC1e97f2d03tzEPpEyVdKiD7MhHAhG8JIU4tWNeIN2lDBedNqpt6iDdFMNMK0fBe9z_maEKoVke_QLudEasPVBt1f_gIcpsX5guOAx_gbLwlyXhPgZYZ1igukUOJjicOMU-xiCR67nEMu0OPk-uDdWFUxF1fAlzjdHWH39LDUa7iFg0rNfZzCH-gPcB_XbgTcjWHuq0FJwY0f0M7gxgwfn889dHV6cnn8ozm_-H52_O288VzL0kg6EAadMUYr1g7EDV72zHk1UKqdAG4Y1a1rATpphPFCC0f1wJlxrOO643voy9a3TnezQi52CtnDOLoZ4potE5K2khtFKvr5FXod1zTX6SyTUivdKkkrxbaUr-vmBINdUphcurOU2MeU7DYlW1OyTylZUUX7z9ZrN0H_T_I3lgrwLZBra_4J6eXv_9g-AJM2nzo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2557678651</pqid></control><display><type>article</type><title>The impact of low pressure pneumoperitoneum in robotic assisted radical prostatectomy: a prospective, randomized, double blinded trial</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>Rohloff, Matthew ; Peifer, Greggory ; Shakuri-Rad, Jaschar ; Maatman, Thomas J.</creator><creatorcontrib>Rohloff, Matthew ; Peifer, Greggory ; Shakuri-Rad, Jaschar ; Maatman, Thomas J.</creatorcontrib><description>Background
Robotic surgery has revolutionized postoperative outcomes across surgical specialties. However, the use of pneumoperitoneum comes with known risks given the change in physiological parameters that accompany its utilization. A recent internal review found a 7% decrease in postoperative ileus rates when utilizing a pneumoperitoneum of 12 mmHg over the standard 15 mmHg in robotic assisted radical prostatectomies (RARP).
Objective
The purpose of this study is to prospectively evaluate the utility of lower pressure pneumoperitoneum by comparing 8 mmHg and 12 mmHg during RARP.
Design, setting and partcipants
Patients were randomly assigned to undergo robotic assisted radical prostatectomy at a pneumoperitoneum pressure of 12 mmHg or 8 mmHg.
Outcome measurements and statistical analysis
The primary outcome was development of postoperative ileus and secondary outcomes were length of operation, estimated blood loss and positive surgical margin status.
Results and limitations
A total of 201 patients were analyzed; 96 patients at 8 mmHg and 105 patients at 12 mmHg. The groups were adequately matched as there were no differences between demographic parameters or medical comorbidities. There was a decrease in postoperative ileus rates with lower pneumoperitoneum pressures; 2% at 8 mmHg and 4.8% at 12 mmHg. There were no clinically significant differences in estimated blood loss, total length of operative time and positive margin status.
Conclusions
Lower pressure pneumoperitoneum during robotic assisted radical prostatectomy is non-inferior to higher pressure pneumoperitoneum levels and the experienced surgeon may safely perform this operation at 8 mmHg to take advantage of the proposed benefits.</description><identifier>ISSN: 0724-4983</identifier><identifier>EISSN: 1433-8726</identifier><identifier>DOI: 10.1007/s00345-020-03486-4</identifier><identifier>PMID: 33057936</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Cancer surgery ; Double-Blind Method ; Humans ; Male ; Medicine ; Medicine & Public Health ; Nephrology ; Oncology ; Original Article ; Patients ; Pneumoperitoneum, Artificial - methods ; Pressure ; Prospective Studies ; Prostate cancer ; Prostatectomy ; Prostatectomy - methods ; Prostatic Neoplasms - surgery ; Robotic surgery ; Robotic Surgical Procedures ; Statistical analysis ; Urological surgery ; Urology</subject><ispartof>World journal of urology, 2021-07, Vol.39 (7), p.2469-2474</ispartof><rights>Springer-Verlag GmbH Germany, part of Springer Nature 2020</rights><rights>2020. Springer-Verlag GmbH Germany, part of Springer Nature.</rights><rights>Springer-Verlag GmbH Germany, part of Springer Nature 2020.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-51f02eb9997628f0afc5d2ac6f117a4e392178a8eeb5949c474a17f329a2b37b3</citedby><cites>FETCH-LOGICAL-c375t-51f02eb9997628f0afc5d2ac6f117a4e392178a8eeb5949c474a17f329a2b37b3</cites><orcidid>0000-0003-4182-0374</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00345-020-03486-4$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00345-020-03486-4$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33057936$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rohloff, Matthew</creatorcontrib><creatorcontrib>Peifer, Greggory</creatorcontrib><creatorcontrib>Shakuri-Rad, Jaschar</creatorcontrib><creatorcontrib>Maatman, Thomas J.</creatorcontrib><title>The impact of low pressure pneumoperitoneum in robotic assisted radical prostatectomy: a prospective, randomized, double blinded trial</title><title>World journal of urology</title><addtitle>World J Urol</addtitle><addtitle>World J Urol</addtitle><description>Background
Robotic surgery has revolutionized postoperative outcomes across surgical specialties. However, the use of pneumoperitoneum comes with known risks given the change in physiological parameters that accompany its utilization. A recent internal review found a 7% decrease in postoperative ileus rates when utilizing a pneumoperitoneum of 12 mmHg over the standard 15 mmHg in robotic assisted radical prostatectomies (RARP).
Objective
The purpose of this study is to prospectively evaluate the utility of lower pressure pneumoperitoneum by comparing 8 mmHg and 12 mmHg during RARP.
Design, setting and partcipants
Patients were randomly assigned to undergo robotic assisted radical prostatectomy at a pneumoperitoneum pressure of 12 mmHg or 8 mmHg.
Outcome measurements and statistical analysis
The primary outcome was development of postoperative ileus and secondary outcomes were length of operation, estimated blood loss and positive surgical margin status.
Results and limitations
A total of 201 patients were analyzed; 96 patients at 8 mmHg and 105 patients at 12 mmHg. The groups were adequately matched as there were no differences between demographic parameters or medical comorbidities. There was a decrease in postoperative ileus rates with lower pneumoperitoneum pressures; 2% at 8 mmHg and 4.8% at 12 mmHg. There were no clinically significant differences in estimated blood loss, total length of operative time and positive margin status.
Conclusions
Lower pressure pneumoperitoneum during robotic assisted radical prostatectomy is non-inferior to higher pressure pneumoperitoneum levels and the experienced surgeon may safely perform this operation at 8 mmHg to take advantage of the proposed benefits.</description><subject>Cancer surgery</subject><subject>Double-Blind Method</subject><subject>Humans</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Nephrology</subject><subject>Oncology</subject><subject>Original Article</subject><subject>Patients</subject><subject>Pneumoperitoneum, Artificial - methods</subject><subject>Pressure</subject><subject>Prospective Studies</subject><subject>Prostate cancer</subject><subject>Prostatectomy</subject><subject>Prostatectomy - methods</subject><subject>Prostatic Neoplasms - surgery</subject><subject>Robotic surgery</subject><subject>Robotic Surgical Procedures</subject><subject>Statistical analysis</subject><subject>Urological surgery</subject><subject>Urology</subject><issn>0724-4983</issn><issn>1433-8726</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNp9kc9OFjEUxRsjkU_0BVyQJm5cMNL_nbIzBJSEhA2sm07njpbMTIe2g8EH4LkpfCgJC1e97f2d03tzEPpEyVdKiD7MhHAhG8JIU4tWNeIN2lDBedNqpt6iDdFMNMK0fBe9z_maEKoVke_QLudEasPVBt1f_gIcpsX5guOAx_gbLwlyXhPgZYZ1igukUOJjicOMU-xiCR67nEMu0OPk-uDdWFUxF1fAlzjdHWH39LDUa7iFg0rNfZzCH-gPcB_XbgTcjWHuq0FJwY0f0M7gxgwfn889dHV6cnn8ozm_-H52_O288VzL0kg6EAadMUYr1g7EDV72zHk1UKqdAG4Y1a1rATpphPFCC0f1wJlxrOO643voy9a3TnezQi52CtnDOLoZ4potE5K2khtFKvr5FXod1zTX6SyTUivdKkkrxbaUr-vmBINdUphcurOU2MeU7DYlW1OyTylZUUX7z9ZrN0H_T_I3lgrwLZBra_4J6eXv_9g-AJM2nzo</recordid><startdate>20210701</startdate><enddate>20210701</enddate><creator>Rohloff, Matthew</creator><creator>Peifer, Greggory</creator><creator>Shakuri-Rad, Jaschar</creator><creator>Maatman, Thomas J.</creator><general>Springer Berlin Heidelberg</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7T5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4182-0374</orcidid></search><sort><creationdate>20210701</creationdate><title>The impact of low pressure pneumoperitoneum in robotic assisted radical prostatectomy: a prospective, randomized, double blinded trial</title><author>Rohloff, Matthew ; Peifer, Greggory ; Shakuri-Rad, Jaschar ; Maatman, Thomas J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-51f02eb9997628f0afc5d2ac6f117a4e392178a8eeb5949c474a17f329a2b37b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Cancer surgery</topic><topic>Double-Blind Method</topic><topic>Humans</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Nephrology</topic><topic>Oncology</topic><topic>Original Article</topic><topic>Patients</topic><topic>Pneumoperitoneum, Artificial - methods</topic><topic>Pressure</topic><topic>Prospective Studies</topic><topic>Prostate cancer</topic><topic>Prostatectomy</topic><topic>Prostatectomy - methods</topic><topic>Prostatic Neoplasms - surgery</topic><topic>Robotic surgery</topic><topic>Robotic Surgical Procedures</topic><topic>Statistical analysis</topic><topic>Urological surgery</topic><topic>Urology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rohloff, Matthew</creatorcontrib><creatorcontrib>Peifer, Greggory</creatorcontrib><creatorcontrib>Shakuri-Rad, Jaschar</creatorcontrib><creatorcontrib>Maatman, Thomas J.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Immunology Abstracts</collection><collection>Health & Medical Collection (Proquest)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>World journal of urology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rohloff, Matthew</au><au>Peifer, Greggory</au><au>Shakuri-Rad, Jaschar</au><au>Maatman, Thomas J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The impact of low pressure pneumoperitoneum in robotic assisted radical prostatectomy: a prospective, randomized, double blinded trial</atitle><jtitle>World journal of urology</jtitle><stitle>World J Urol</stitle><addtitle>World J Urol</addtitle><date>2021-07-01</date><risdate>2021</risdate><volume>39</volume><issue>7</issue><spage>2469</spage><epage>2474</epage><pages>2469-2474</pages><issn>0724-4983</issn><eissn>1433-8726</eissn><abstract>Background
Robotic surgery has revolutionized postoperative outcomes across surgical specialties. However, the use of pneumoperitoneum comes with known risks given the change in physiological parameters that accompany its utilization. A recent internal review found a 7% decrease in postoperative ileus rates when utilizing a pneumoperitoneum of 12 mmHg over the standard 15 mmHg in robotic assisted radical prostatectomies (RARP).
Objective
The purpose of this study is to prospectively evaluate the utility of lower pressure pneumoperitoneum by comparing 8 mmHg and 12 mmHg during RARP.
Design, setting and partcipants
Patients were randomly assigned to undergo robotic assisted radical prostatectomy at a pneumoperitoneum pressure of 12 mmHg or 8 mmHg.
Outcome measurements and statistical analysis
The primary outcome was development of postoperative ileus and secondary outcomes were length of operation, estimated blood loss and positive surgical margin status.
Results and limitations
A total of 201 patients were analyzed; 96 patients at 8 mmHg and 105 patients at 12 mmHg. The groups were adequately matched as there were no differences between demographic parameters or medical comorbidities. There was a decrease in postoperative ileus rates with lower pneumoperitoneum pressures; 2% at 8 mmHg and 4.8% at 12 mmHg. There were no clinically significant differences in estimated blood loss, total length of operative time and positive margin status.
Conclusions
Lower pressure pneumoperitoneum during robotic assisted radical prostatectomy is non-inferior to higher pressure pneumoperitoneum levels and the experienced surgeon may safely perform this operation at 8 mmHg to take advantage of the proposed benefits.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>33057936</pmid><doi>10.1007/s00345-020-03486-4</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0003-4182-0374</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0724-4983 |
ispartof | World journal of urology, 2021-07, Vol.39 (7), p.2469-2474 |
issn | 0724-4983 1433-8726 |
language | eng |
recordid | cdi_proquest_miscellaneous_2451853960 |
source | MEDLINE; SpringerLink Journals |
subjects | Cancer surgery Double-Blind Method Humans Male Medicine Medicine & Public Health Nephrology Oncology Original Article Patients Pneumoperitoneum, Artificial - methods Pressure Prospective Studies Prostate cancer Prostatectomy Prostatectomy - methods Prostatic Neoplasms - surgery Robotic surgery Robotic Surgical Procedures Statistical analysis Urological surgery Urology |
title | The impact of low pressure pneumoperitoneum in robotic assisted radical prostatectomy: a prospective, randomized, double blinded trial |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T07%3A56%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20impact%20of%20low%20pressure%20pneumoperitoneum%20in%20robotic%20assisted%20radical%20prostatectomy:%20a%20prospective,%20randomized,%20double%20blinded%20trial&rft.jtitle=World%20journal%20of%20urology&rft.au=Rohloff,%20Matthew&rft.date=2021-07-01&rft.volume=39&rft.issue=7&rft.spage=2469&rft.epage=2474&rft.pages=2469-2474&rft.issn=0724-4983&rft.eissn=1433-8726&rft_id=info:doi/10.1007/s00345-020-03486-4&rft_dat=%3Cproquest_cross%3E2451853960%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2557678651&rft_id=info:pmid/33057936&rfr_iscdi=true |