Retention of removable complete dentures made with different posterior palatal seal techniques and oral health quality of life: A clinical study

How different methods of recording posterior palatal seal affect removable complete-denture retention and oral health quality of life is unclear. The purpose of this clinical study was to compare the retention and oral health quality of life (OHIP-14) between conventional and arbitrary posterior pal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 2021-09, Vol.126 (3), p.393-397
Hauptverfasser: Tharakan, Sanjana Rebecca, Chander, Naveen Gopi, Anitha, Kuttae Viswanathan, Balasubramaniam, Muthukumar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 397
container_issue 3
container_start_page 393
container_title The Journal of prosthetic dentistry
container_volume 126
creator Tharakan, Sanjana Rebecca
Chander, Naveen Gopi
Anitha, Kuttae Viswanathan
Balasubramaniam, Muthukumar
description How different methods of recording posterior palatal seal affect removable complete-denture retention and oral health quality of life is unclear. The purpose of this clinical study was to compare the retention and oral health quality of life (OHIP-14) between conventional and arbitrary posterior palatal seal techniques in participants with removable complete dentures. Edentulous patients were recruited according to definitive criteria. The participants were randomly divided into conventional and arbitrary seal. After the delivery of the denture, the retention was evaluated with a force gauge dynamometer and at 3, 6, 9, and 12 months. Denture satisfaction was evaluated with the OHIP-14 questionnaire. Data were statistically analyzed by using the t test and repeated measure ANOVA (α=.05). The mean ±standard deviation values (N) for conventional seal at 0, 3, 6, 9, and 12 months by dynamometer in the anterior region ranged from 4.73 ±0.78 to 4.90 ±0.81 and in the posterior region between 5.07 ±0.84 and 5.31 ±0.99. Dynamometer values for arbitrary seal in the anterior region were from 4.56 ±0.77 to 4.88 ±0.81, and in the posterior, it varied between 4.74 ±0.74 and 5.15 ±0.81. Force gauge values (N) for conventional and arbitrary seal were in the range of 18.35 ±2.84 to 20.69 ±3.89. The general mean ±SD OHIP-14 was higher for the conventional seal at 3.12 ±0.25 than for the arbitrary seal at 2.73 ±0.23 The difference between the conventional and arbitrary seal techniques was not statistically significant (P>.05) No significant difference in complete denture retention was detected between the 2 posterior palatal seal techniques. Oral health quality of life was higher with the conventional seal technique.
doi_str_mv 10.1016/j.prosdent.2020.08.005
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2444603995</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391320304327</els_id><sourcerecordid>2444603995</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-3f8c2af86bfabb2cbea07cbb1cfd3371232530b617e397bb728ca3972b0995913</originalsourceid><addsrcrecordid>eNqFUctuHCEQRFGieO3kFyyOucy4gZ1XTrEs5yFZihQlZwRMo2XFDGNgHO1f5JPDaO1ccwHUXdXVVBFyzaBmwNqbY73EkEacc82BQw19DdC8IjsGQ1e1_Z69JjsAzisxMHFBLlM6AkDfdOwtuRB8aFjfwY78-YG5DHFhpsHSiFN4UtojNWFafGnRTWKNmOikRqS_XT7Q0VmLsdTpElLG6EKki_IqK08TliOjOczucS0sNY80xFI7lEbhPq7Ku3zaxLyz-JHeUuPd7MzGzet4ekfeWOUTvn--r8ivz_c_775WD9-_fLu7faiMaPtcCdsbrmzfaqu05kajgs5ozYwdhegYF7wRoFvWoRg6rTveG1VeXMMwNMWSK_LhPLf4uG2a5eSSQe_VjGFNku_3-xZEARdoe4aaYnmKaOUS3aTiSTKQWxryKF_SkFsaEnpZ0ijE62eNVU84_qO92F8An84ALD99chhlMg5ng6OLaLIcg_ufxl979qKi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2444603995</pqid></control><display><type>article</type><title>Retention of removable complete dentures made with different posterior palatal seal techniques and oral health quality of life: A clinical study</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Tharakan, Sanjana Rebecca ; Chander, Naveen Gopi ; Anitha, Kuttae Viswanathan ; Balasubramaniam, Muthukumar</creator><creatorcontrib>Tharakan, Sanjana Rebecca ; Chander, Naveen Gopi ; Anitha, Kuttae Viswanathan ; Balasubramaniam, Muthukumar</creatorcontrib><description>How different methods of recording posterior palatal seal affect removable complete-denture retention and oral health quality of life is unclear. The purpose of this clinical study was to compare the retention and oral health quality of life (OHIP-14) between conventional and arbitrary posterior palatal seal techniques in participants with removable complete dentures. Edentulous patients were recruited according to definitive criteria. The participants were randomly divided into conventional and arbitrary seal. After the delivery of the denture, the retention was evaluated with a force gauge dynamometer and at 3, 6, 9, and 12 months. Denture satisfaction was evaluated with the OHIP-14 questionnaire. Data were statistically analyzed by using the t test and repeated measure ANOVA (α=.05). The mean ±standard deviation values (N) for conventional seal at 0, 3, 6, 9, and 12 months by dynamometer in the anterior region ranged from 4.73 ±0.78 to 4.90 ±0.81 and in the posterior region between 5.07 ±0.84 and 5.31 ±0.99. Dynamometer values for arbitrary seal in the anterior region were from 4.56 ±0.77 to 4.88 ±0.81, and in the posterior, it varied between 4.74 ±0.74 and 5.15 ±0.81. Force gauge values (N) for conventional and arbitrary seal were in the range of 18.35 ±2.84 to 20.69 ±3.89. The general mean ±SD OHIP-14 was higher for the conventional seal at 3.12 ±0.25 than for the arbitrary seal at 2.73 ±0.23 The difference between the conventional and arbitrary seal techniques was not statistically significant (P&gt;.05) No significant difference in complete denture retention was detected between the 2 posterior palatal seal techniques. Oral health quality of life was higher with the conventional seal technique.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2020.08.005</identifier><identifier>PMID: 32951870</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Denture Retention ; Denture, Complete ; Humans ; Mouth, Edentulous ; Oral Health ; Patient Satisfaction ; Quality of Life</subject><ispartof>The Journal of prosthetic dentistry, 2021-09, Vol.126 (3), p.393-397</ispartof><rights>2020 Editorial Council for the Journal of Prosthetic Dentistry</rights><rights>Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-3f8c2af86bfabb2cbea07cbb1cfd3371232530b617e397bb728ca3972b0995913</citedby><cites>FETCH-LOGICAL-c368t-3f8c2af86bfabb2cbea07cbb1cfd3371232530b617e397bb728ca3972b0995913</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.prosdent.2020.08.005$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32951870$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tharakan, Sanjana Rebecca</creatorcontrib><creatorcontrib>Chander, Naveen Gopi</creatorcontrib><creatorcontrib>Anitha, Kuttae Viswanathan</creatorcontrib><creatorcontrib>Balasubramaniam, Muthukumar</creatorcontrib><title>Retention of removable complete dentures made with different posterior palatal seal techniques and oral health quality of life: A clinical study</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>How different methods of recording posterior palatal seal affect removable complete-denture retention and oral health quality of life is unclear. The purpose of this clinical study was to compare the retention and oral health quality of life (OHIP-14) between conventional and arbitrary posterior palatal seal techniques in participants with removable complete dentures. Edentulous patients were recruited according to definitive criteria. The participants were randomly divided into conventional and arbitrary seal. After the delivery of the denture, the retention was evaluated with a force gauge dynamometer and at 3, 6, 9, and 12 months. Denture satisfaction was evaluated with the OHIP-14 questionnaire. Data were statistically analyzed by using the t test and repeated measure ANOVA (α=.05). The mean ±standard deviation values (N) for conventional seal at 0, 3, 6, 9, and 12 months by dynamometer in the anterior region ranged from 4.73 ±0.78 to 4.90 ±0.81 and in the posterior region between 5.07 ±0.84 and 5.31 ±0.99. Dynamometer values for arbitrary seal in the anterior region were from 4.56 ±0.77 to 4.88 ±0.81, and in the posterior, it varied between 4.74 ±0.74 and 5.15 ±0.81. Force gauge values (N) for conventional and arbitrary seal were in the range of 18.35 ±2.84 to 20.69 ±3.89. The general mean ±SD OHIP-14 was higher for the conventional seal at 3.12 ±0.25 than for the arbitrary seal at 2.73 ±0.23 The difference between the conventional and arbitrary seal techniques was not statistically significant (P&gt;.05) No significant difference in complete denture retention was detected between the 2 posterior palatal seal techniques. Oral health quality of life was higher with the conventional seal technique.</description><subject>Denture Retention</subject><subject>Denture, Complete</subject><subject>Humans</subject><subject>Mouth, Edentulous</subject><subject>Oral Health</subject><subject>Patient Satisfaction</subject><subject>Quality of Life</subject><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFUctuHCEQRFGieO3kFyyOucy4gZ1XTrEs5yFZihQlZwRMo2XFDGNgHO1f5JPDaO1ccwHUXdXVVBFyzaBmwNqbY73EkEacc82BQw19DdC8IjsGQ1e1_Z69JjsAzisxMHFBLlM6AkDfdOwtuRB8aFjfwY78-YG5DHFhpsHSiFN4UtojNWFafGnRTWKNmOikRqS_XT7Q0VmLsdTpElLG6EKki_IqK08TliOjOczucS0sNY80xFI7lEbhPq7Ku3zaxLyz-JHeUuPd7MzGzet4ekfeWOUTvn--r8ivz_c_775WD9-_fLu7faiMaPtcCdsbrmzfaqu05kajgs5ozYwdhegYF7wRoFvWoRg6rTveG1VeXMMwNMWSK_LhPLf4uG2a5eSSQe_VjGFNku_3-xZEARdoe4aaYnmKaOUS3aTiSTKQWxryKF_SkFsaEnpZ0ijE62eNVU84_qO92F8An84ALD99chhlMg5ng6OLaLIcg_ufxl979qKi</recordid><startdate>202109</startdate><enddate>202109</enddate><creator>Tharakan, Sanjana Rebecca</creator><creator>Chander, Naveen Gopi</creator><creator>Anitha, Kuttae Viswanathan</creator><creator>Balasubramaniam, Muthukumar</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202109</creationdate><title>Retention of removable complete dentures made with different posterior palatal seal techniques and oral health quality of life: A clinical study</title><author>Tharakan, Sanjana Rebecca ; Chander, Naveen Gopi ; Anitha, Kuttae Viswanathan ; Balasubramaniam, Muthukumar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-3f8c2af86bfabb2cbea07cbb1cfd3371232530b617e397bb728ca3972b0995913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Denture Retention</topic><topic>Denture, Complete</topic><topic>Humans</topic><topic>Mouth, Edentulous</topic><topic>Oral Health</topic><topic>Patient Satisfaction</topic><topic>Quality of Life</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tharakan, Sanjana Rebecca</creatorcontrib><creatorcontrib>Chander, Naveen Gopi</creatorcontrib><creatorcontrib>Anitha, Kuttae Viswanathan</creatorcontrib><creatorcontrib>Balasubramaniam, Muthukumar</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tharakan, Sanjana Rebecca</au><au>Chander, Naveen Gopi</au><au>Anitha, Kuttae Viswanathan</au><au>Balasubramaniam, Muthukumar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Retention of removable complete dentures made with different posterior palatal seal techniques and oral health quality of life: A clinical study</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2021-09</date><risdate>2021</risdate><volume>126</volume><issue>3</issue><spage>393</spage><epage>397</epage><pages>393-397</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>How different methods of recording posterior palatal seal affect removable complete-denture retention and oral health quality of life is unclear. The purpose of this clinical study was to compare the retention and oral health quality of life (OHIP-14) between conventional and arbitrary posterior palatal seal techniques in participants with removable complete dentures. Edentulous patients were recruited according to definitive criteria. The participants were randomly divided into conventional and arbitrary seal. After the delivery of the denture, the retention was evaluated with a force gauge dynamometer and at 3, 6, 9, and 12 months. Denture satisfaction was evaluated with the OHIP-14 questionnaire. Data were statistically analyzed by using the t test and repeated measure ANOVA (α=.05). The mean ±standard deviation values (N) for conventional seal at 0, 3, 6, 9, and 12 months by dynamometer in the anterior region ranged from 4.73 ±0.78 to 4.90 ±0.81 and in the posterior region between 5.07 ±0.84 and 5.31 ±0.99. Dynamometer values for arbitrary seal in the anterior region were from 4.56 ±0.77 to 4.88 ±0.81, and in the posterior, it varied between 4.74 ±0.74 and 5.15 ±0.81. Force gauge values (N) for conventional and arbitrary seal were in the range of 18.35 ±2.84 to 20.69 ±3.89. The general mean ±SD OHIP-14 was higher for the conventional seal at 3.12 ±0.25 than for the arbitrary seal at 2.73 ±0.23 The difference between the conventional and arbitrary seal techniques was not statistically significant (P&gt;.05) No significant difference in complete denture retention was detected between the 2 posterior palatal seal techniques. Oral health quality of life was higher with the conventional seal technique.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32951870</pmid><doi>10.1016/j.prosdent.2020.08.005</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-3913
ispartof The Journal of prosthetic dentistry, 2021-09, Vol.126 (3), p.393-397
issn 0022-3913
1097-6841
language eng
recordid cdi_proquest_miscellaneous_2444603995
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Denture Retention
Denture, Complete
Humans
Mouth, Edentulous
Oral Health
Patient Satisfaction
Quality of Life
title Retention of removable complete dentures made with different posterior palatal seal techniques and oral health quality of life: A clinical study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T22%3A47%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Retention%20of%20removable%20complete%20dentures%20made%20with%20different%20posterior%20palatal%20seal%20techniques%20and%20oral%20health%20quality%20of%20life:%20A%20clinical%20study&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Tharakan,%20Sanjana%20Rebecca&rft.date=2021-09&rft.volume=126&rft.issue=3&rft.spage=393&rft.epage=397&rft.pages=393-397&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2020.08.005&rft_dat=%3Cproquest_cross%3E2444603995%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2444603995&rft_id=info:pmid/32951870&rft_els_id=S0022391320304327&rfr_iscdi=true