Sagitta of ophthalmic lenses

Purpose To propose alternative formulas for the sagitta calculation of ophthalmic lenses. Methods Equation factoring. Results The conventional sagitta formula is algebraically inconsistent when applied to curves with direction‐oriented radii. It is possible to correct this problem by factoring it. C...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ophthalmic & physiological optics 2020-11, Vol.40 (6), p.828-829
1. Verfasser: Faria‐e‐Sousa, Sidney Julio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 829
container_issue 6
container_start_page 828
container_title Ophthalmic & physiological optics
container_volume 40
creator Faria‐e‐Sousa, Sidney Julio
description Purpose To propose alternative formulas for the sagitta calculation of ophthalmic lenses. Methods Equation factoring. Results The conventional sagitta formula is algebraically inconsistent when applied to curves with direction‐oriented radii. It is possible to correct this problem by factoring it. Conclusions The conventional sagitta formula can and should be replaced by unambiguous equations.
doi_str_mv 10.1111/opo.12732
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2444376928</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2454404332</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3302-ff599609302abe3d05163e1d0d26b8f647de73ac2c2f9d05754ca71b8ce6fa273</originalsourceid><addsrcrecordid>eNp10E1LxDAQBuAgCtbVg3cPBS966G6-0x5lWT9goYJ6DmmauF3SpjYtsv_eaD0J5jID80wYXgAuEVyi-Fa-90uEBcFHIEFUsAwRRI5BAnHsGYX5KTgLYQ8hFELkCbh6Ue_NOKrU29T3u3GnXNvo1JkumHAOTqxywVz81gV4u9-8rh-zbfnwtL7bZpoQiDNrWVFwWMReVYbUkCFODKphjXmVW05FbQRRGmtsizgVjGolUJVrw62Kxy7AzfxvP_iPyYRRtk3QxjnVGT8FiSmlRPAC55Fe_6F7Pw1dvC4qRimkhOCobmelBx_CYKzsh6ZVw0EiKL9zkjEn-ZNTtKvZfjbOHP6Hsnwu540vketm5Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2454404332</pqid></control><display><type>article</type><title>Sagitta of ophthalmic lenses</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Faria‐e‐Sousa, Sidney Julio</creator><creatorcontrib>Faria‐e‐Sousa, Sidney Julio</creatorcontrib><description>Purpose To propose alternative formulas for the sagitta calculation of ophthalmic lenses. Methods Equation factoring. Results The conventional sagitta formula is algebraically inconsistent when applied to curves with direction‐oriented radii. It is possible to correct this problem by factoring it. Conclusions The conventional sagitta formula can and should be replaced by unambiguous equations.</description><identifier>ISSN: 0275-5408</identifier><identifier>EISSN: 1475-1313</identifier><identifier>DOI: 10.1111/opo.12732</identifier><language>eng</language><publisher>London: Wiley Subscription Services, Inc</publisher><subject>lens thickness ; ophthalmic lenses ; sag ; sagitta</subject><ispartof>Ophthalmic &amp; physiological optics, 2020-11, Vol.40 (6), p.828-829</ispartof><rights>2020 The Author Ophthalmic &amp; Physiological Optics © 2020 The College of Optometrists</rights><rights>Copyright © 2020 The College of Optometrists</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3302-ff599609302abe3d05163e1d0d26b8f647de73ac2c2f9d05754ca71b8ce6fa273</citedby><cites>FETCH-LOGICAL-c3302-ff599609302abe3d05163e1d0d26b8f647de73ac2c2f9d05754ca71b8ce6fa273</cites><orcidid>0000-0003-3021-8476</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fopo.12732$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fopo.12732$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,27905,27906,45555,45556</link.rule.ids></links><search><creatorcontrib>Faria‐e‐Sousa, Sidney Julio</creatorcontrib><title>Sagitta of ophthalmic lenses</title><title>Ophthalmic &amp; physiological optics</title><description>Purpose To propose alternative formulas for the sagitta calculation of ophthalmic lenses. Methods Equation factoring. Results The conventional sagitta formula is algebraically inconsistent when applied to curves with direction‐oriented radii. It is possible to correct this problem by factoring it. Conclusions The conventional sagitta formula can and should be replaced by unambiguous equations.</description><subject>lens thickness</subject><subject>ophthalmic lenses</subject><subject>sag</subject><subject>sagitta</subject><issn>0275-5408</issn><issn>1475-1313</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp10E1LxDAQBuAgCtbVg3cPBS966G6-0x5lWT9goYJ6DmmauF3SpjYtsv_eaD0J5jID80wYXgAuEVyi-Fa-90uEBcFHIEFUsAwRRI5BAnHsGYX5KTgLYQ8hFELkCbh6Ue_NOKrU29T3u3GnXNvo1JkumHAOTqxywVz81gV4u9-8rh-zbfnwtL7bZpoQiDNrWVFwWMReVYbUkCFODKphjXmVW05FbQRRGmtsizgVjGolUJVrw62Kxy7AzfxvP_iPyYRRtk3QxjnVGT8FiSmlRPAC55Fe_6F7Pw1dvC4qRimkhOCobmelBx_CYKzsh6ZVw0EiKL9zkjEn-ZNTtKvZfjbOHP6Hsnwu540vketm5Q</recordid><startdate>202011</startdate><enddate>202011</enddate><creator>Faria‐e‐Sousa, Sidney Julio</creator><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QG</scope><scope>7T5</scope><scope>7TK</scope><scope>H94</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-3021-8476</orcidid></search><sort><creationdate>202011</creationdate><title>Sagitta of ophthalmic lenses</title><author>Faria‐e‐Sousa, Sidney Julio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3302-ff599609302abe3d05163e1d0d26b8f647de73ac2c2f9d05754ca71b8ce6fa273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>lens thickness</topic><topic>ophthalmic lenses</topic><topic>sag</topic><topic>sagitta</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Faria‐e‐Sousa, Sidney Julio</creatorcontrib><collection>CrossRef</collection><collection>Animal Behavior Abstracts</collection><collection>Immunology Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Ophthalmic &amp; physiological optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Faria‐e‐Sousa, Sidney Julio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sagitta of ophthalmic lenses</atitle><jtitle>Ophthalmic &amp; physiological optics</jtitle><date>2020-11</date><risdate>2020</risdate><volume>40</volume><issue>6</issue><spage>828</spage><epage>829</epage><pages>828-829</pages><issn>0275-5408</issn><eissn>1475-1313</eissn><abstract>Purpose To propose alternative formulas for the sagitta calculation of ophthalmic lenses. Methods Equation factoring. Results The conventional sagitta formula is algebraically inconsistent when applied to curves with direction‐oriented radii. It is possible to correct this problem by factoring it. Conclusions The conventional sagitta formula can and should be replaced by unambiguous equations.</abstract><cop>London</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1111/opo.12732</doi><tpages>2</tpages><orcidid>https://orcid.org/0000-0003-3021-8476</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0275-5408
ispartof Ophthalmic & physiological optics, 2020-11, Vol.40 (6), p.828-829
issn 0275-5408
1475-1313
language eng
recordid cdi_proquest_miscellaneous_2444376928
source Wiley Online Library Journals Frontfile Complete
subjects lens thickness
ophthalmic lenses
sag
sagitta
title Sagitta of ophthalmic lenses
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T04%3A45%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sagitta%20of%20ophthalmic%20lenses&rft.jtitle=Ophthalmic%20&%20physiological%20optics&rft.au=Faria%E2%80%90e%E2%80%90Sousa,%20Sidney%20Julio&rft.date=2020-11&rft.volume=40&rft.issue=6&rft.spage=828&rft.epage=829&rft.pages=828-829&rft.issn=0275-5408&rft.eissn=1475-1313&rft_id=info:doi/10.1111/opo.12732&rft_dat=%3Cproquest_cross%3E2454404332%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2454404332&rft_id=info:pmid/&rfr_iscdi=true