Spectrophotometric determination of platinum with iodide and pyronine G
A sensitive and selective spectrophotometric procedure for the determination of platinum is described. The method is based on the interaction of Pyronine G with the hexaiodoplatinate (IV) anion to form a pink product that is stable for 24 h when stabilised with gelatin. Platinum concentrations as lo...
Gespeichert in:
Veröffentlicht in: | Analyst (London) 1984-01, Vol.109 (11), p.1405-1407 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1407 |
---|---|
container_issue | 11 |
container_start_page | 1405 |
container_title | Analyst (London) |
container_volume | 109 |
creator | Jaya, Sambamoorthy Rao, Talasila Prasada Ramakrishna, Tiruvesaloor Venkatrama |
description | A sensitive and selective spectrophotometric procedure for the determination of platinum is described. The method is based on the interaction of Pyronine G with the hexaiodoplatinate (IV) anion to form a pink product that is stable for 24 h when stabilised with gelatin. Platinum concentrations as low as 0.02 p.p.m. can be readily determined. The method is precise and has been applied to the determination of platinum in synthetic alloys and mineral samples and palladium foil. 10 ref.--AA |
doi_str_mv | 10.1039/AN9840901405 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_24408743</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>24408743</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-a0307e06bcbdb1a755df593cdb32700aa24cd36a2b21df3d7200b37015a692c83</originalsourceid><addsrcrecordid>eNpFkE1LxDAYhIMouH7c_AE5iCerb776cVxEV2HRg3oub5OUjbRJTbKI_97KLnqaGXhmDkPIBYMbBqK5XT43tYQGmAR1QBZMlLJQiteHZAEAouClksfkJKWPOTJQsCCr18nqHMO0CTmMNkenqbHZxtF5zC54Gno6DbP125F-ubyhLhhnLEVv6PQdg3fe0tUZOepxSPZ8r6fk_eH-7e6xWL-snu6W60IL1uQCQUBloex0ZzqGlVKmV43QphO8AkDkUhtRIu84M70wFQfoRAVMYdlwXYtTcrXbnWL43NqU29ElbYcBvQ3b1HIpoa6kmMHrHahjSCnavp2iGzF-twza37da9P9vzfjlfheTxqGP6LVLf5264XMFxA8v8mmr</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>24408743</pqid></control><display><type>article</type><title>Spectrophotometric determination of platinum with iodide and pyronine G</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Jaya, Sambamoorthy ; Rao, Talasila Prasada ; Ramakrishna, Tiruvesaloor Venkatrama</creator><creatorcontrib>Jaya, Sambamoorthy ; Rao, Talasila Prasada ; Ramakrishna, Tiruvesaloor Venkatrama</creatorcontrib><description>A sensitive and selective spectrophotometric procedure for the determination of platinum is described. The method is based on the interaction of Pyronine G with the hexaiodoplatinate (IV) anion to form a pink product that is stable for 24 h when stabilised with gelatin. Platinum concentrations as low as 0.02 p.p.m. can be readily determined. The method is precise and has been applied to the determination of platinum in synthetic alloys and mineral samples and palladium foil. 10 ref.--AA</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/AN9840901405</identifier><identifier>CODEN: ANALAO</identifier><language>eng</language><publisher>Cambridge: Royal Society of Chemistry</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; Spectrometric and optical methods</subject><ispartof>Analyst (London), 1984-01, Vol.109 (11), p.1405-1407</ispartof><rights>1985 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-a0307e06bcbdb1a755df593cdb32700aa24cd36a2b21df3d7200b37015a692c83</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,2818,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=8920390$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Jaya, Sambamoorthy</creatorcontrib><creatorcontrib>Rao, Talasila Prasada</creatorcontrib><creatorcontrib>Ramakrishna, Tiruvesaloor Venkatrama</creatorcontrib><title>Spectrophotometric determination of platinum with iodide and pyronine G</title><title>Analyst (London)</title><description>A sensitive and selective spectrophotometric procedure for the determination of platinum is described. The method is based on the interaction of Pyronine G with the hexaiodoplatinate (IV) anion to form a pink product that is stable for 24 h when stabilised with gelatin. Platinum concentrations as low as 0.02 p.p.m. can be readily determined. The method is precise and has been applied to the determination of platinum in synthetic alloys and mineral samples and palladium foil. 10 ref.--AA</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Spectrometric and optical methods</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1984</creationdate><recordtype>article</recordtype><recordid>eNpFkE1LxDAYhIMouH7c_AE5iCerb776cVxEV2HRg3oub5OUjbRJTbKI_97KLnqaGXhmDkPIBYMbBqK5XT43tYQGmAR1QBZMlLJQiteHZAEAouClksfkJKWPOTJQsCCr18nqHMO0CTmMNkenqbHZxtF5zC54Gno6DbP125F-ubyhLhhnLEVv6PQdg3fe0tUZOepxSPZ8r6fk_eH-7e6xWL-snu6W60IL1uQCQUBloex0ZzqGlVKmV43QphO8AkDkUhtRIu84M70wFQfoRAVMYdlwXYtTcrXbnWL43NqU29ElbYcBvQ3b1HIpoa6kmMHrHahjSCnavp2iGzF-twza37da9P9vzfjlfheTxqGP6LVLf5264XMFxA8v8mmr</recordid><startdate>19840101</startdate><enddate>19840101</enddate><creator>Jaya, Sambamoorthy</creator><creator>Rao, Talasila Prasada</creator><creator>Ramakrishna, Tiruvesaloor Venkatrama</creator><general>Royal Society of Chemistry</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19840101</creationdate><title>Spectrophotometric determination of platinum with iodide and pyronine G</title><author>Jaya, Sambamoorthy ; Rao, Talasila Prasada ; Ramakrishna, Tiruvesaloor Venkatrama</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-a0307e06bcbdb1a755df593cdb32700aa24cd36a2b21df3d7200b37015a692c83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1984</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jaya, Sambamoorthy</creatorcontrib><creatorcontrib>Rao, Talasila Prasada</creatorcontrib><creatorcontrib>Ramakrishna, Tiruvesaloor Venkatrama</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jaya, Sambamoorthy</au><au>Rao, Talasila Prasada</au><au>Ramakrishna, Tiruvesaloor Venkatrama</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Spectrophotometric determination of platinum with iodide and pyronine G</atitle><jtitle>Analyst (London)</jtitle><date>1984-01-01</date><risdate>1984</risdate><volume>109</volume><issue>11</issue><spage>1405</spage><epage>1407</epage><pages>1405-1407</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><coden>ANALAO</coden><abstract>A sensitive and selective spectrophotometric procedure for the determination of platinum is described. The method is based on the interaction of Pyronine G with the hexaiodoplatinate (IV) anion to form a pink product that is stable for 24 h when stabilised with gelatin. Platinum concentrations as low as 0.02 p.p.m. can be readily determined. The method is precise and has been applied to the determination of platinum in synthetic alloys and mineral samples and palladium foil. 10 ref.--AA</abstract><cop>Cambridge</cop><pub>Royal Society of Chemistry</pub><doi>10.1039/AN9840901405</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2654 |
ispartof | Analyst (London), 1984-01, Vol.109 (11), p.1405-1407 |
issn | 0003-2654 1364-5528 |
language | eng |
recordid | cdi_proquest_miscellaneous_24408743 |
source | Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection |
subjects | Analytical chemistry Chemistry Exact sciences and technology Spectrometric and optical methods |
title | Spectrophotometric determination of platinum with iodide and pyronine G |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T23%3A47%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Spectrophotometric%20determination%20of%20platinum%20with%20iodide%20and%20pyronine%20G&rft.jtitle=Analyst%20(London)&rft.au=Jaya,%20Sambamoorthy&rft.date=1984-01-01&rft.volume=109&rft.issue=11&rft.spage=1405&rft.epage=1407&rft.pages=1405-1407&rft.issn=0003-2654&rft.eissn=1364-5528&rft.coden=ANALAO&rft_id=info:doi/10.1039/AN9840901405&rft_dat=%3Cproquest_cross%3E24408743%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=24408743&rft_id=info:pmid/&rfr_iscdi=true |