Development of a dynamic deformable thorax phantom for the quality management of deformable image registration

•We developed a dynamic deformable thorax phantom for DIR commissioning and QA.•Our phantom can create various deformation patterns with various marker patterns.•DIR results with different marker settings and DIR parameters were obtained using this phantom. The purpose of this study was to develop a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physica medica 2020-09, Vol.77, p.100-107
Hauptverfasser: Sugawara, Yasuharu, Kadoya, Noriyuki, Kotabe, Kazuki, Nakajima, Yujiro, Ikeda, Ryutaro, Tanabe, Shunpei, Ohashi, Haruna, Jingu, Keiichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 107
container_issue
container_start_page 100
container_title Physica medica
container_volume 77
creator Sugawara, Yasuharu
Kadoya, Noriyuki
Kotabe, Kazuki
Nakajima, Yujiro
Ikeda, Ryutaro
Tanabe, Shunpei
Ohashi, Haruna
Jingu, Keiichi
description •We developed a dynamic deformable thorax phantom for DIR commissioning and QA.•Our phantom can create various deformation patterns with various marker patterns.•DIR results with different marker settings and DIR parameters were obtained using this phantom. The purpose of this study was to develop a novel dynamic deformable thorax phantom for deformable image registration (DIR) quality assurance (QA) and to verify as a tool for commissioning and DIR QA. The phantom consists of a base phantom, an inner phantom, and a motor-derived piston. The base phantom is an acrylic cylinder phantom with a diameter of 180 mm. The inner phantom consists of deformable, 20 mm thick disk-shaped sponges. To evaluate the physical characteristics of the phantom, we evaluated its image quality and deformation. DIR accuracies were evaluated using the three types of commercially DIR software (MIM, RayStation, and Velocity AI) to test the feasibility of this phantom. We used different DIR parameters to test the impact of parameters on DIR accuracy in various phantom settings. To evaluate DIR accuracy, a target registration error (TRE) was calculated using the anatomical landmark points. The three locations (i.e., distal, middle, and proximal positions) had different displacement amounts. This result indicated that the inner phantom was not moved but deformed. In cases with different phantom settings and marker settings, the ranges of the average TRE were 0.63–15.60 mm (MIM). In cases with different DIR parameters settings, the ranges of the average TRE were as follows: 0.73–7.10 mm (MIM), 8.25–8.66 mm (RayStation), and 8.26–8.43 mm (Velocity). These results suggest that our phantom could evaluate the detailed DIR behaviors with TRE. Therefore, this is indicative of the potential usefulness of our phantom in DIR commissioning and QA.
doi_str_mv 10.1016/j.ejmp.2020.08.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2436394305</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S112017972030199X</els_id><sourcerecordid>2436394305</sourcerecordid><originalsourceid>FETCH-LOGICAL-c399t-40c5a6687b1bef1941ab0a74da572488f42fdf5add534e31a0eaf928a200b6b83</originalsourceid><addsrcrecordid>eNp9kM1LxDAQxYso-PkPeMrRS-sk_QYvsn6C4EXBW5i2k92UtukmWXH_e7OsgidPMzzeb5j3ouiSQ8KBF9d9Qv04JwIEJFAlAOVBdMJLkcW85h-HYecCYl7W5XF06lwPkAqR5yfRdEefNJh5pMkzoxiybjvhqFvWkTJ2xGYg5lfG4hebVzh5M7KgB4nYeoOD9ls24oRL-r3wh9Nj0JmlpXbeotdmOo-OFA6OLn7mWfT-cP-2eIpfXh-fF7cvcZvWtY8zaHMsiqpseEOK1xnHBrDMOsxDpqpSmVCdyrHr8jSjlCMQqlpUKACaoqnSs-hqf3e2Zr0h5-WoXUvDgBOZjZMiS4u0zlLIg1Xsra01zllScrbhcbuVHOSuXNnLXblyV66ESoZyA3SzhyiE-NRkpWs1TS112lLrZWf0f_g3vluFbQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2436394305</pqid></control><display><type>article</type><title>Development of a dynamic deformable thorax phantom for the quality management of deformable image registration</title><source>Elsevier ScienceDirect Journals</source><creator>Sugawara, Yasuharu ; Kadoya, Noriyuki ; Kotabe, Kazuki ; Nakajima, Yujiro ; Ikeda, Ryutaro ; Tanabe, Shunpei ; Ohashi, Haruna ; Jingu, Keiichi</creator><creatorcontrib>Sugawara, Yasuharu ; Kadoya, Noriyuki ; Kotabe, Kazuki ; Nakajima, Yujiro ; Ikeda, Ryutaro ; Tanabe, Shunpei ; Ohashi, Haruna ; Jingu, Keiichi</creatorcontrib><description>•We developed a dynamic deformable thorax phantom for DIR commissioning and QA.•Our phantom can create various deformation patterns with various marker patterns.•DIR results with different marker settings and DIR parameters were obtained using this phantom. The purpose of this study was to develop a novel dynamic deformable thorax phantom for deformable image registration (DIR) quality assurance (QA) and to verify as a tool for commissioning and DIR QA. The phantom consists of a base phantom, an inner phantom, and a motor-derived piston. The base phantom is an acrylic cylinder phantom with a diameter of 180 mm. The inner phantom consists of deformable, 20 mm thick disk-shaped sponges. To evaluate the physical characteristics of the phantom, we evaluated its image quality and deformation. DIR accuracies were evaluated using the three types of commercially DIR software (MIM, RayStation, and Velocity AI) to test the feasibility of this phantom. We used different DIR parameters to test the impact of parameters on DIR accuracy in various phantom settings. To evaluate DIR accuracy, a target registration error (TRE) was calculated using the anatomical landmark points. The three locations (i.e., distal, middle, and proximal positions) had different displacement amounts. This result indicated that the inner phantom was not moved but deformed. In cases with different phantom settings and marker settings, the ranges of the average TRE were 0.63–15.60 mm (MIM). In cases with different DIR parameters settings, the ranges of the average TRE were as follows: 0.73–7.10 mm (MIM), 8.25–8.66 mm (RayStation), and 8.26–8.43 mm (Velocity). These results suggest that our phantom could evaluate the detailed DIR behaviors with TRE. Therefore, this is indicative of the potential usefulness of our phantom in DIR commissioning and QA.</description><identifier>ISSN: 1120-1797</identifier><identifier>EISSN: 1724-191X</identifier><identifier>DOI: 10.1016/j.ejmp.2020.08.007</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Deformable image registration ; Physical phantom ; Quality assurance ; Radiotherapy ; Target registration error</subject><ispartof>Physica medica, 2020-09, Vol.77, p.100-107</ispartof><rights>2020 Associazione Italiana di Fisica Medica</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c399t-40c5a6687b1bef1941ab0a74da572488f42fdf5add534e31a0eaf928a200b6b83</citedby><cites>FETCH-LOGICAL-c399t-40c5a6687b1bef1941ab0a74da572488f42fdf5add534e31a0eaf928a200b6b83</cites><orcidid>0000-0001-5018-3800</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S112017972030199X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Sugawara, Yasuharu</creatorcontrib><creatorcontrib>Kadoya, Noriyuki</creatorcontrib><creatorcontrib>Kotabe, Kazuki</creatorcontrib><creatorcontrib>Nakajima, Yujiro</creatorcontrib><creatorcontrib>Ikeda, Ryutaro</creatorcontrib><creatorcontrib>Tanabe, Shunpei</creatorcontrib><creatorcontrib>Ohashi, Haruna</creatorcontrib><creatorcontrib>Jingu, Keiichi</creatorcontrib><title>Development of a dynamic deformable thorax phantom for the quality management of deformable image registration</title><title>Physica medica</title><description>•We developed a dynamic deformable thorax phantom for DIR commissioning and QA.•Our phantom can create various deformation patterns with various marker patterns.•DIR results with different marker settings and DIR parameters were obtained using this phantom. The purpose of this study was to develop a novel dynamic deformable thorax phantom for deformable image registration (DIR) quality assurance (QA) and to verify as a tool for commissioning and DIR QA. The phantom consists of a base phantom, an inner phantom, and a motor-derived piston. The base phantom is an acrylic cylinder phantom with a diameter of 180 mm. The inner phantom consists of deformable, 20 mm thick disk-shaped sponges. To evaluate the physical characteristics of the phantom, we evaluated its image quality and deformation. DIR accuracies were evaluated using the three types of commercially DIR software (MIM, RayStation, and Velocity AI) to test the feasibility of this phantom. We used different DIR parameters to test the impact of parameters on DIR accuracy in various phantom settings. To evaluate DIR accuracy, a target registration error (TRE) was calculated using the anatomical landmark points. The three locations (i.e., distal, middle, and proximal positions) had different displacement amounts. This result indicated that the inner phantom was not moved but deformed. In cases with different phantom settings and marker settings, the ranges of the average TRE were 0.63–15.60 mm (MIM). In cases with different DIR parameters settings, the ranges of the average TRE were as follows: 0.73–7.10 mm (MIM), 8.25–8.66 mm (RayStation), and 8.26–8.43 mm (Velocity). These results suggest that our phantom could evaluate the detailed DIR behaviors with TRE. Therefore, this is indicative of the potential usefulness of our phantom in DIR commissioning and QA.</description><subject>Deformable image registration</subject><subject>Physical phantom</subject><subject>Quality assurance</subject><subject>Radiotherapy</subject><subject>Target registration error</subject><issn>1120-1797</issn><issn>1724-191X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kM1LxDAQxYso-PkPeMrRS-sk_QYvsn6C4EXBW5i2k92UtukmWXH_e7OsgidPMzzeb5j3ouiSQ8KBF9d9Qv04JwIEJFAlAOVBdMJLkcW85h-HYecCYl7W5XF06lwPkAqR5yfRdEefNJh5pMkzoxiybjvhqFvWkTJ2xGYg5lfG4hebVzh5M7KgB4nYeoOD9ls24oRL-r3wh9Nj0JmlpXbeotdmOo-OFA6OLn7mWfT-cP-2eIpfXh-fF7cvcZvWtY8zaHMsiqpseEOK1xnHBrDMOsxDpqpSmVCdyrHr8jSjlCMQqlpUKACaoqnSs-hqf3e2Zr0h5-WoXUvDgBOZjZMiS4u0zlLIg1Xsra01zllScrbhcbuVHOSuXNnLXblyV66ESoZyA3SzhyiE-NRkpWs1TS112lLrZWf0f_g3vluFbQ</recordid><startdate>202009</startdate><enddate>202009</enddate><creator>Sugawara, Yasuharu</creator><creator>Kadoya, Noriyuki</creator><creator>Kotabe, Kazuki</creator><creator>Nakajima, Yujiro</creator><creator>Ikeda, Ryutaro</creator><creator>Tanabe, Shunpei</creator><creator>Ohashi, Haruna</creator><creator>Jingu, Keiichi</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5018-3800</orcidid></search><sort><creationdate>202009</creationdate><title>Development of a dynamic deformable thorax phantom for the quality management of deformable image registration</title><author>Sugawara, Yasuharu ; Kadoya, Noriyuki ; Kotabe, Kazuki ; Nakajima, Yujiro ; Ikeda, Ryutaro ; Tanabe, Shunpei ; Ohashi, Haruna ; Jingu, Keiichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c399t-40c5a6687b1bef1941ab0a74da572488f42fdf5add534e31a0eaf928a200b6b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Deformable image registration</topic><topic>Physical phantom</topic><topic>Quality assurance</topic><topic>Radiotherapy</topic><topic>Target registration error</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sugawara, Yasuharu</creatorcontrib><creatorcontrib>Kadoya, Noriyuki</creatorcontrib><creatorcontrib>Kotabe, Kazuki</creatorcontrib><creatorcontrib>Nakajima, Yujiro</creatorcontrib><creatorcontrib>Ikeda, Ryutaro</creatorcontrib><creatorcontrib>Tanabe, Shunpei</creatorcontrib><creatorcontrib>Ohashi, Haruna</creatorcontrib><creatorcontrib>Jingu, Keiichi</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physica medica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sugawara, Yasuharu</au><au>Kadoya, Noriyuki</au><au>Kotabe, Kazuki</au><au>Nakajima, Yujiro</au><au>Ikeda, Ryutaro</au><au>Tanabe, Shunpei</au><au>Ohashi, Haruna</au><au>Jingu, Keiichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a dynamic deformable thorax phantom for the quality management of deformable image registration</atitle><jtitle>Physica medica</jtitle><date>2020-09</date><risdate>2020</risdate><volume>77</volume><spage>100</spage><epage>107</epage><pages>100-107</pages><issn>1120-1797</issn><eissn>1724-191X</eissn><abstract>•We developed a dynamic deformable thorax phantom for DIR commissioning and QA.•Our phantom can create various deformation patterns with various marker patterns.•DIR results with different marker settings and DIR parameters were obtained using this phantom. The purpose of this study was to develop a novel dynamic deformable thorax phantom for deformable image registration (DIR) quality assurance (QA) and to verify as a tool for commissioning and DIR QA. The phantom consists of a base phantom, an inner phantom, and a motor-derived piston. The base phantom is an acrylic cylinder phantom with a diameter of 180 mm. The inner phantom consists of deformable, 20 mm thick disk-shaped sponges. To evaluate the physical characteristics of the phantom, we evaluated its image quality and deformation. DIR accuracies were evaluated using the three types of commercially DIR software (MIM, RayStation, and Velocity AI) to test the feasibility of this phantom. We used different DIR parameters to test the impact of parameters on DIR accuracy in various phantom settings. To evaluate DIR accuracy, a target registration error (TRE) was calculated using the anatomical landmark points. The three locations (i.e., distal, middle, and proximal positions) had different displacement amounts. This result indicated that the inner phantom was not moved but deformed. In cases with different phantom settings and marker settings, the ranges of the average TRE were 0.63–15.60 mm (MIM). In cases with different DIR parameters settings, the ranges of the average TRE were as follows: 0.73–7.10 mm (MIM), 8.25–8.66 mm (RayStation), and 8.26–8.43 mm (Velocity). These results suggest that our phantom could evaluate the detailed DIR behaviors with TRE. Therefore, this is indicative of the potential usefulness of our phantom in DIR commissioning and QA.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.ejmp.2020.08.007</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-5018-3800</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1120-1797
ispartof Physica medica, 2020-09, Vol.77, p.100-107
issn 1120-1797
1724-191X
language eng
recordid cdi_proquest_miscellaneous_2436394305
source Elsevier ScienceDirect Journals
subjects Deformable image registration
Physical phantom
Quality assurance
Radiotherapy
Target registration error
title Development of a dynamic deformable thorax phantom for the quality management of deformable image registration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T17%3A38%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20dynamic%20deformable%20thorax%20phantom%20for%20the%20quality%20management%20of%20deformable%20image%20registration&rft.jtitle=Physica%20medica&rft.au=Sugawara,%20Yasuharu&rft.date=2020-09&rft.volume=77&rft.spage=100&rft.epage=107&rft.pages=100-107&rft.issn=1120-1797&rft.eissn=1724-191X&rft_id=info:doi/10.1016/j.ejmp.2020.08.007&rft_dat=%3Cproquest_cross%3E2436394305%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2436394305&rft_id=info:pmid/&rft_els_id=S112017972030199X&rfr_iscdi=true