Comparison of Subthreshold 577 and 810 nm Micropulse Laser Effects on Heat-Shock Protein Activation Kinetics: Implications for Treatment Efficacy and Safety
To compare the safety and efficacy of 810 versus 577 nm laser wavelengths for micropulse subthreshold (sublethal) laser treatment by mathematical analysis. Two different representative laser parameter sets for micropulsed subthreshold diode laser treatment, one employing 810 nm and the other 577 nm,...
Gespeichert in:
Veröffentlicht in: | Translational vision science & technology 2020-04, Vol.9 (5), p.23-23 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 23 |
---|---|
container_issue | 5 |
container_start_page | 23 |
container_title | Translational vision science & technology |
container_volume | 9 |
creator | Chang, David B Luttrull, Jeffrey K |
description | To compare the safety and efficacy of 810 versus 577 nm laser wavelengths for micropulse subthreshold (sublethal) laser treatment by mathematical analysis.
Two different representative laser parameter sets for micropulsed subthreshold diode laser treatment, one employing 810 nm and the other 577 nm, are compared with regard to efficacy by analysis of the kinetics of laser-induced heat-shock protein (HSP) activation; and for safety, by scaling law analysis.
Kinetics analysis of laser-induced HSP activation shows that the primary therapeutic effect of laser is thermal incitement of a long-term wavelength-independent increase in the rate of HSP-mediated protein repair specific to sick and dysfunctional cells, rather than from short-term increases in free intracellular HSP concentrations. Scaling law analysis of the same 810 and 577 nm laser parameters, however, finds treatment safety highly wavelength-sensitive, favoring 810 over 577 nm.
Mathematical analyses of the effects retinal laser-induced HSP activation provide important insights into the mechanism of action and the importance of wavelength selection in modern retinal laser therapy. Our analyses find 810 and 577 nm to be equally effective, but 810 nm having a significantly wider therapeutic range/safety margin, and thus less likely to cause inadvertent, and thus unpredictable, laser-induced retinal damage, than 577 nm.
Mathematical analysis of enzyme reaction kinetics provides important insights into the mechanism of action and clinical implications of wavelength selection in modern retinal laser therapy. |
doi_str_mv | 10.1167/tvst.9.5.23 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2436393034</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2436393034</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-4acfed1643627078832af118d8bc3ab8ba797409d90c5622dae56b320b70cac13</originalsourceid><addsrcrecordid>eNpNUU1LxDAQDaK4onvyLjkK0pqPtmm9Lcv6gSsKu55DmiZstG1qkgr7X_yxZv3Cucww7817zAwApxilGBfsMrz7kFZpnhK6B44ILrKE5BXe_1dPwNT7FxSjKPMsKw7BhJKS4KzKj8DH3HaDcMbbHloNV2MdNk75jW0bmDMGRd_AEiPYd_DBSGeHsfUKLoVXDi60VjJ4GEdvlQjJamPlK3xyNijTw5kM5l0EE9F706tgpL-Cd93QGvnV9VBbB9cuTnaqDzu1iMjtl-VKaBW2J-BAi-g3_cnH4Pl6sZ7fJsvHm7v5bJlISoqQZEJq1cR1aUEYYmVJidAYl01ZSyrqshasYhmqmgrJvCCkESovakpQzVB0xPQYnH_rDs6-jcoH3hkvVduKXtnRcxKVaUURzSL14psab-G9U5oPznTCbTlGfPcRvvsIr3jOCY3ssx_hse5U88f9vT_9BOiiiE8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2436393034</pqid></control><display><type>article</type><title>Comparison of Subthreshold 577 and 810 nm Micropulse Laser Effects on Heat-Shock Protein Activation Kinetics: Implications for Treatment Efficacy and Safety</title><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Chang, David B ; Luttrull, Jeffrey K</creator><creatorcontrib>Chang, David B ; Luttrull, Jeffrey K</creatorcontrib><description>To compare the safety and efficacy of 810 versus 577 nm laser wavelengths for micropulse subthreshold (sublethal) laser treatment by mathematical analysis.
Two different representative laser parameter sets for micropulsed subthreshold diode laser treatment, one employing 810 nm and the other 577 nm, are compared with regard to efficacy by analysis of the kinetics of laser-induced heat-shock protein (HSP) activation; and for safety, by scaling law analysis.
Kinetics analysis of laser-induced HSP activation shows that the primary therapeutic effect of laser is thermal incitement of a long-term wavelength-independent increase in the rate of HSP-mediated protein repair specific to sick and dysfunctional cells, rather than from short-term increases in free intracellular HSP concentrations. Scaling law analysis of the same 810 and 577 nm laser parameters, however, finds treatment safety highly wavelength-sensitive, favoring 810 over 577 nm.
Mathematical analyses of the effects retinal laser-induced HSP activation provide important insights into the mechanism of action and the importance of wavelength selection in modern retinal laser therapy. Our analyses find 810 and 577 nm to be equally effective, but 810 nm having a significantly wider therapeutic range/safety margin, and thus less likely to cause inadvertent, and thus unpredictable, laser-induced retinal damage, than 577 nm.
Mathematical analysis of enzyme reaction kinetics provides important insights into the mechanism of action and clinical implications of wavelength selection in modern retinal laser therapy.</description><identifier>ISSN: 2164-2591</identifier><identifier>EISSN: 2164-2591</identifier><identifier>DOI: 10.1167/tvst.9.5.23</identifier><identifier>PMID: 32821495</identifier><language>eng</language><publisher>United States</publisher><subject>Heat-Shock Proteins ; Kinetics ; Laser Coagulation ; Retina ; Treatment Outcome</subject><ispartof>Translational vision science & technology, 2020-04, Vol.9 (5), p.23-23</ispartof><rights>Copyright 2020 The Authors.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c326t-4acfed1643627078832af118d8bc3ab8ba797409d90c5622dae56b320b70cac13</citedby><cites>FETCH-LOGICAL-c326t-4acfed1643627078832af118d8bc3ab8ba797409d90c5622dae56b320b70cac13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32821495$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chang, David B</creatorcontrib><creatorcontrib>Luttrull, Jeffrey K</creatorcontrib><title>Comparison of Subthreshold 577 and 810 nm Micropulse Laser Effects on Heat-Shock Protein Activation Kinetics: Implications for Treatment Efficacy and Safety</title><title>Translational vision science & technology</title><addtitle>Transl Vis Sci Technol</addtitle><description>To compare the safety and efficacy of 810 versus 577 nm laser wavelengths for micropulse subthreshold (sublethal) laser treatment by mathematical analysis.
Two different representative laser parameter sets for micropulsed subthreshold diode laser treatment, one employing 810 nm and the other 577 nm, are compared with regard to efficacy by analysis of the kinetics of laser-induced heat-shock protein (HSP) activation; and for safety, by scaling law analysis.
Kinetics analysis of laser-induced HSP activation shows that the primary therapeutic effect of laser is thermal incitement of a long-term wavelength-independent increase in the rate of HSP-mediated protein repair specific to sick and dysfunctional cells, rather than from short-term increases in free intracellular HSP concentrations. Scaling law analysis of the same 810 and 577 nm laser parameters, however, finds treatment safety highly wavelength-sensitive, favoring 810 over 577 nm.
Mathematical analyses of the effects retinal laser-induced HSP activation provide important insights into the mechanism of action and the importance of wavelength selection in modern retinal laser therapy. Our analyses find 810 and 577 nm to be equally effective, but 810 nm having a significantly wider therapeutic range/safety margin, and thus less likely to cause inadvertent, and thus unpredictable, laser-induced retinal damage, than 577 nm.
Mathematical analysis of enzyme reaction kinetics provides important insights into the mechanism of action and clinical implications of wavelength selection in modern retinal laser therapy.</description><subject>Heat-Shock Proteins</subject><subject>Kinetics</subject><subject>Laser Coagulation</subject><subject>Retina</subject><subject>Treatment Outcome</subject><issn>2164-2591</issn><issn>2164-2591</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNUU1LxDAQDaK4onvyLjkK0pqPtmm9Lcv6gSsKu55DmiZstG1qkgr7X_yxZv3Cucww7817zAwApxilGBfsMrz7kFZpnhK6B44ILrKE5BXe_1dPwNT7FxSjKPMsKw7BhJKS4KzKj8DH3HaDcMbbHloNV2MdNk75jW0bmDMGRd_AEiPYd_DBSGeHsfUKLoVXDi60VjJ4GEdvlQjJamPlK3xyNijTw5kM5l0EE9F706tgpL-Cd93QGvnV9VBbB9cuTnaqDzu1iMjtl-VKaBW2J-BAi-g3_cnH4Pl6sZ7fJsvHm7v5bJlISoqQZEJq1cR1aUEYYmVJidAYl01ZSyrqshasYhmqmgrJvCCkESovakpQzVB0xPQYnH_rDs6-jcoH3hkvVduKXtnRcxKVaUURzSL14psab-G9U5oPznTCbTlGfPcRvvsIr3jOCY3ssx_hse5U88f9vT_9BOiiiE8</recordid><startdate>20200401</startdate><enddate>20200401</enddate><creator>Chang, David B</creator><creator>Luttrull, Jeffrey K</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20200401</creationdate><title>Comparison of Subthreshold 577 and 810 nm Micropulse Laser Effects on Heat-Shock Protein Activation Kinetics: Implications for Treatment Efficacy and Safety</title><author>Chang, David B ; Luttrull, Jeffrey K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-4acfed1643627078832af118d8bc3ab8ba797409d90c5622dae56b320b70cac13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Heat-Shock Proteins</topic><topic>Kinetics</topic><topic>Laser Coagulation</topic><topic>Retina</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chang, David B</creatorcontrib><creatorcontrib>Luttrull, Jeffrey K</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Translational vision science & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chang, David B</au><au>Luttrull, Jeffrey K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Subthreshold 577 and 810 nm Micropulse Laser Effects on Heat-Shock Protein Activation Kinetics: Implications for Treatment Efficacy and Safety</atitle><jtitle>Translational vision science & technology</jtitle><addtitle>Transl Vis Sci Technol</addtitle><date>2020-04-01</date><risdate>2020</risdate><volume>9</volume><issue>5</issue><spage>23</spage><epage>23</epage><pages>23-23</pages><issn>2164-2591</issn><eissn>2164-2591</eissn><abstract>To compare the safety and efficacy of 810 versus 577 nm laser wavelengths for micropulse subthreshold (sublethal) laser treatment by mathematical analysis.
Two different representative laser parameter sets for micropulsed subthreshold diode laser treatment, one employing 810 nm and the other 577 nm, are compared with regard to efficacy by analysis of the kinetics of laser-induced heat-shock protein (HSP) activation; and for safety, by scaling law analysis.
Kinetics analysis of laser-induced HSP activation shows that the primary therapeutic effect of laser is thermal incitement of a long-term wavelength-independent increase in the rate of HSP-mediated protein repair specific to sick and dysfunctional cells, rather than from short-term increases in free intracellular HSP concentrations. Scaling law analysis of the same 810 and 577 nm laser parameters, however, finds treatment safety highly wavelength-sensitive, favoring 810 over 577 nm.
Mathematical analyses of the effects retinal laser-induced HSP activation provide important insights into the mechanism of action and the importance of wavelength selection in modern retinal laser therapy. Our analyses find 810 and 577 nm to be equally effective, but 810 nm having a significantly wider therapeutic range/safety margin, and thus less likely to cause inadvertent, and thus unpredictable, laser-induced retinal damage, than 577 nm.
Mathematical analysis of enzyme reaction kinetics provides important insights into the mechanism of action and clinical implications of wavelength selection in modern retinal laser therapy.</abstract><cop>United States</cop><pmid>32821495</pmid><doi>10.1167/tvst.9.5.23</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2164-2591 |
ispartof | Translational vision science & technology, 2020-04, Vol.9 (5), p.23-23 |
issn | 2164-2591 2164-2591 |
language | eng |
recordid | cdi_proquest_miscellaneous_2436393034 |
source | MEDLINE; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central |
subjects | Heat-Shock Proteins Kinetics Laser Coagulation Retina Treatment Outcome |
title | Comparison of Subthreshold 577 and 810 nm Micropulse Laser Effects on Heat-Shock Protein Activation Kinetics: Implications for Treatment Efficacy and Safety |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T13%3A24%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Subthreshold%20577%20and%20810%20nm%20Micropulse%20Laser%20Effects%20on%20Heat-Shock%20Protein%20Activation%20Kinetics:%20Implications%20for%20Treatment%20Efficacy%20and%20Safety&rft.jtitle=Translational%20vision%20science%20&%20technology&rft.au=Chang,%20David%20B&rft.date=2020-04-01&rft.volume=9&rft.issue=5&rft.spage=23&rft.epage=23&rft.pages=23-23&rft.issn=2164-2591&rft.eissn=2164-2591&rft_id=info:doi/10.1167/tvst.9.5.23&rft_dat=%3Cproquest_cross%3E2436393034%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2436393034&rft_id=info:pmid/32821495&rfr_iscdi=true |