Poly (alanine)/NaOH/ MoS2/MWCNTs modified carbon paste electrode for simultaneous detection of dopamine, ascorbic acid, serotonin and guanine

[Display omitted] •Electropolymerization of alanine on MoS2/acid-treated MWCNTs modified CPE.•The prepared electrode was used for the sensitive detection of DA, AA, 5-HT and GU.•Individual and simultaneous determination studies of DA, AA, 5-HT and GU.•Effective determination of target molecules in r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Colloids and surfaces, B, Biointerfaces B, Biointerfaces, 2020-12, Vol.196, p.111299-111299, Article 111299
Hauptverfasser: Kumar, Mohan, Wang, Miao, Kumara Swamy, B.E., Praveen, M., Zhao, Wei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 111299
container_issue
container_start_page 111299
container_title Colloids and surfaces, B, Biointerfaces
container_volume 196
creator Kumar, Mohan
Wang, Miao
Kumara Swamy, B.E.
Praveen, M.
Zhao, Wei
description [Display omitted] •Electropolymerization of alanine on MoS2/acid-treated MWCNTs modified CPE.•The prepared electrode was used for the sensitive detection of DA, AA, 5-HT and GU.•Individual and simultaneous determination studies of DA, AA, 5-HT and GU.•Effective determination of target molecules in real samples. The detection of biomolecules such as dopamine (DA), ascorbic acid (AA), serotonin (5-HT), and guanine (GU) is essential for biomedical chemistry and disease diagnosis. In this work, MoS2/acid-treated MWCNTs composite (Ms-atCNTs) was first prepared and then used to modify carbon paste electrode (CPE), followed by electropolymerization of alanine in the presence of NaOH. The resulting modified electrode (p-Aln/Ms-atCNTCPE) was tested for the simultaneous detection of DA, AA, 5-HT, and GU using cyclic voltammetry and differential pulse voltammetry in phosphate buffer solution (PBS). The p-Aln/Ms-atCNTCPE showed excellent electrochemical response towards the detection of DA, AA, 5-HT, and GU. The electrode was also effectively utilized for concentration variation studies of a mixture containing these biomolecules. The detection limits were found to be 0.08 μM, 3.9 μM, 0.1 μM, and 0.1 μM for DA, AA, 5-HT, and GU, respectively. Furthermore, the proposed sensor displayed favorable repeatability, stability, and selectivity, as well as the usefulness for the detection of target molecules in real samples, such as DA injections, vitamin C tablets, herring sperm DNA, and human blood serum.
doi_str_mv 10.1016/j.colsurfb.2020.111299
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2434472578</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S092777652030655X</els_id><sourcerecordid>2434472578</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-f99e799df0c4c57c71cd5c4d13dbeed1707ef90244452050fff208c282deae7a3</originalsourceid><addsrcrecordid>eNqFkM1KLDEQhYMoOP68gmTpBXsmSacn07t7GdQR_AMVlyFTqUiG7s7cpFvwIXxno61rVwVV55zifISccDbljM9nmymEJg3RraeCibzkXNT1DpnwhSoLWc7VLpmwWqhCqXm1Tw5S2jDGhORqQt7vQ_NGT01jOt_hn9mtuVvN6E14ELOb5-XtY6JtsN55tBRMXIeObk3qkWKD0MdgkboQafLt0PSmwzAkarHPN5-lwVEbtqbNyWfUJAhx7YEa8PaMJoyhD_kpNZ2lL8PX_yOy50yT8Ph7HpKni_PH5aq4vru8Wv67LqCUVV-4ukZV19YxkFApUBxsBdLy0q4RLVdMoatzQykrwSrmnBNsAWIhLBpUpjwkp2PuNob_A6Zetz4BNs1YQQtZSqlEpRZZOh-lEENKEZ3eRt-a-KY505_89Ub_8Nef_PXIPxv_jkbMRV49Rp3AYwdofcx8tA3-t4gP33CT4g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2434472578</pqid></control><display><type>article</type><title>Poly (alanine)/NaOH/ MoS2/MWCNTs modified carbon paste electrode for simultaneous detection of dopamine, ascorbic acid, serotonin and guanine</title><source>Elsevier ScienceDirect Journals</source><creator>Kumar, Mohan ; Wang, Miao ; Kumara Swamy, B.E. ; Praveen, M. ; Zhao, Wei</creator><creatorcontrib>Kumar, Mohan ; Wang, Miao ; Kumara Swamy, B.E. ; Praveen, M. ; Zhao, Wei</creatorcontrib><description>[Display omitted] •Electropolymerization of alanine on MoS2/acid-treated MWCNTs modified CPE.•The prepared electrode was used for the sensitive detection of DA, AA, 5-HT and GU.•Individual and simultaneous determination studies of DA, AA, 5-HT and GU.•Effective determination of target molecules in real samples. The detection of biomolecules such as dopamine (DA), ascorbic acid (AA), serotonin (5-HT), and guanine (GU) is essential for biomedical chemistry and disease diagnosis. In this work, MoS2/acid-treated MWCNTs composite (Ms-atCNTs) was first prepared and then used to modify carbon paste electrode (CPE), followed by electropolymerization of alanine in the presence of NaOH. The resulting modified electrode (p-Aln/Ms-atCNTCPE) was tested for the simultaneous detection of DA, AA, 5-HT, and GU using cyclic voltammetry and differential pulse voltammetry in phosphate buffer solution (PBS). The p-Aln/Ms-atCNTCPE showed excellent electrochemical response towards the detection of DA, AA, 5-HT, and GU. The electrode was also effectively utilized for concentration variation studies of a mixture containing these biomolecules. The detection limits were found to be 0.08 μM, 3.9 μM, 0.1 μM, and 0.1 μM for DA, AA, 5-HT, and GU, respectively. Furthermore, the proposed sensor displayed favorable repeatability, stability, and selectivity, as well as the usefulness for the detection of target molecules in real samples, such as DA injections, vitamin C tablets, herring sperm DNA, and human blood serum.</description><identifier>ISSN: 0927-7765</identifier><identifier>EISSN: 1873-4367</identifier><identifier>DOI: 10.1016/j.colsurfb.2020.111299</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Carbon paste electrode ; Dopamine ; MoS2 ; Poly (alanine) ; Serotonin</subject><ispartof>Colloids and surfaces, B, Biointerfaces, 2020-12, Vol.196, p.111299-111299, Article 111299</ispartof><rights>2020 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-f99e799df0c4c57c71cd5c4d13dbeed1707ef90244452050fff208c282deae7a3</citedby><cites>FETCH-LOGICAL-c345t-f99e799df0c4c57c71cd5c4d13dbeed1707ef90244452050fff208c282deae7a3</cites><orcidid>0000-0001-5407-6164</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.colsurfb.2020.111299$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids></links><search><creatorcontrib>Kumar, Mohan</creatorcontrib><creatorcontrib>Wang, Miao</creatorcontrib><creatorcontrib>Kumara Swamy, B.E.</creatorcontrib><creatorcontrib>Praveen, M.</creatorcontrib><creatorcontrib>Zhao, Wei</creatorcontrib><title>Poly (alanine)/NaOH/ MoS2/MWCNTs modified carbon paste electrode for simultaneous detection of dopamine, ascorbic acid, serotonin and guanine</title><title>Colloids and surfaces, B, Biointerfaces</title><description>[Display omitted] •Electropolymerization of alanine on MoS2/acid-treated MWCNTs modified CPE.•The prepared electrode was used for the sensitive detection of DA, AA, 5-HT and GU.•Individual and simultaneous determination studies of DA, AA, 5-HT and GU.•Effective determination of target molecules in real samples. The detection of biomolecules such as dopamine (DA), ascorbic acid (AA), serotonin (5-HT), and guanine (GU) is essential for biomedical chemistry and disease diagnosis. In this work, MoS2/acid-treated MWCNTs composite (Ms-atCNTs) was first prepared and then used to modify carbon paste electrode (CPE), followed by electropolymerization of alanine in the presence of NaOH. The resulting modified electrode (p-Aln/Ms-atCNTCPE) was tested for the simultaneous detection of DA, AA, 5-HT, and GU using cyclic voltammetry and differential pulse voltammetry in phosphate buffer solution (PBS). The p-Aln/Ms-atCNTCPE showed excellent electrochemical response towards the detection of DA, AA, 5-HT, and GU. The electrode was also effectively utilized for concentration variation studies of a mixture containing these biomolecules. The detection limits were found to be 0.08 μM, 3.9 μM, 0.1 μM, and 0.1 μM for DA, AA, 5-HT, and GU, respectively. Furthermore, the proposed sensor displayed favorable repeatability, stability, and selectivity, as well as the usefulness for the detection of target molecules in real samples, such as DA injections, vitamin C tablets, herring sperm DNA, and human blood serum.</description><subject>Carbon paste electrode</subject><subject>Dopamine</subject><subject>MoS2</subject><subject>Poly (alanine)</subject><subject>Serotonin</subject><issn>0927-7765</issn><issn>1873-4367</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkM1KLDEQhYMoOP68gmTpBXsmSacn07t7GdQR_AMVlyFTqUiG7s7cpFvwIXxno61rVwVV55zifISccDbljM9nmymEJg3RraeCibzkXNT1DpnwhSoLWc7VLpmwWqhCqXm1Tw5S2jDGhORqQt7vQ_NGT01jOt_hn9mtuVvN6E14ELOb5-XtY6JtsN55tBRMXIeObk3qkWKD0MdgkboQafLt0PSmwzAkarHPN5-lwVEbtqbNyWfUJAhx7YEa8PaMJoyhD_kpNZ2lL8PX_yOy50yT8Ph7HpKni_PH5aq4vru8Wv67LqCUVV-4ukZV19YxkFApUBxsBdLy0q4RLVdMoatzQykrwSrmnBNsAWIhLBpUpjwkp2PuNob_A6Zetz4BNs1YQQtZSqlEpRZZOh-lEENKEZ3eRt-a-KY505_89Ub_8Nef_PXIPxv_jkbMRV49Rp3AYwdofcx8tA3-t4gP33CT4g</recordid><startdate>202012</startdate><enddate>202012</enddate><creator>Kumar, Mohan</creator><creator>Wang, Miao</creator><creator>Kumara Swamy, B.E.</creator><creator>Praveen, M.</creator><creator>Zhao, Wei</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5407-6164</orcidid></search><sort><creationdate>202012</creationdate><title>Poly (alanine)/NaOH/ MoS2/MWCNTs modified carbon paste electrode for simultaneous detection of dopamine, ascorbic acid, serotonin and guanine</title><author>Kumar, Mohan ; Wang, Miao ; Kumara Swamy, B.E. ; Praveen, M. ; Zhao, Wei</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-f99e799df0c4c57c71cd5c4d13dbeed1707ef90244452050fff208c282deae7a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Carbon paste electrode</topic><topic>Dopamine</topic><topic>MoS2</topic><topic>Poly (alanine)</topic><topic>Serotonin</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kumar, Mohan</creatorcontrib><creatorcontrib>Wang, Miao</creatorcontrib><creatorcontrib>Kumara Swamy, B.E.</creatorcontrib><creatorcontrib>Praveen, M.</creatorcontrib><creatorcontrib>Zhao, Wei</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Colloids and surfaces, B, Biointerfaces</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kumar, Mohan</au><au>Wang, Miao</au><au>Kumara Swamy, B.E.</au><au>Praveen, M.</au><au>Zhao, Wei</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Poly (alanine)/NaOH/ MoS2/MWCNTs modified carbon paste electrode for simultaneous detection of dopamine, ascorbic acid, serotonin and guanine</atitle><jtitle>Colloids and surfaces, B, Biointerfaces</jtitle><date>2020-12</date><risdate>2020</risdate><volume>196</volume><spage>111299</spage><epage>111299</epage><pages>111299-111299</pages><artnum>111299</artnum><issn>0927-7765</issn><eissn>1873-4367</eissn><abstract>[Display omitted] •Electropolymerization of alanine on MoS2/acid-treated MWCNTs modified CPE.•The prepared electrode was used for the sensitive detection of DA, AA, 5-HT and GU.•Individual and simultaneous determination studies of DA, AA, 5-HT and GU.•Effective determination of target molecules in real samples. The detection of biomolecules such as dopamine (DA), ascorbic acid (AA), serotonin (5-HT), and guanine (GU) is essential for biomedical chemistry and disease diagnosis. In this work, MoS2/acid-treated MWCNTs composite (Ms-atCNTs) was first prepared and then used to modify carbon paste electrode (CPE), followed by electropolymerization of alanine in the presence of NaOH. The resulting modified electrode (p-Aln/Ms-atCNTCPE) was tested for the simultaneous detection of DA, AA, 5-HT, and GU using cyclic voltammetry and differential pulse voltammetry in phosphate buffer solution (PBS). The p-Aln/Ms-atCNTCPE showed excellent electrochemical response towards the detection of DA, AA, 5-HT, and GU. The electrode was also effectively utilized for concentration variation studies of a mixture containing these biomolecules. The detection limits were found to be 0.08 μM, 3.9 μM, 0.1 μM, and 0.1 μM for DA, AA, 5-HT, and GU, respectively. Furthermore, the proposed sensor displayed favorable repeatability, stability, and selectivity, as well as the usefulness for the detection of target molecules in real samples, such as DA injections, vitamin C tablets, herring sperm DNA, and human blood serum.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.colsurfb.2020.111299</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0001-5407-6164</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0927-7765
ispartof Colloids and surfaces, B, Biointerfaces, 2020-12, Vol.196, p.111299-111299, Article 111299
issn 0927-7765
1873-4367
language eng
recordid cdi_proquest_miscellaneous_2434472578
source Elsevier ScienceDirect Journals
subjects Carbon paste electrode
Dopamine
MoS2
Poly (alanine)
Serotonin
title Poly (alanine)/NaOH/ MoS2/MWCNTs modified carbon paste electrode for simultaneous detection of dopamine, ascorbic acid, serotonin and guanine
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T12%3A28%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Poly%20(alanine)/NaOH/%20MoS2/MWCNTs%20modified%20carbon%20paste%20electrode%20for%20simultaneous%20detection%20of%20dopamine,%20ascorbic%20acid,%20serotonin%20and%20guanine&rft.jtitle=Colloids%20and%20surfaces,%20B,%20Biointerfaces&rft.au=Kumar,%20Mohan&rft.date=2020-12&rft.volume=196&rft.spage=111299&rft.epage=111299&rft.pages=111299-111299&rft.artnum=111299&rft.issn=0927-7765&rft.eissn=1873-4367&rft_id=info:doi/10.1016/j.colsurfb.2020.111299&rft_dat=%3Cproquest_cross%3E2434472578%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2434472578&rft_id=info:pmid/&rft_els_id=S092777652030655X&rfr_iscdi=true