Two-Year Results of a Multicenter Prospective Observational Study of the Zenith Spiral-Z Limb Deployed in the External Iliac Artery During Endovascular Aneurysm Repair

Background:Limited data is available on the use of a polyester graft limb with a helical stent configuration deployed in the external iliac artery (EIA) during endovascular aneurysm repair (EVAR), so we prospectively analyzed the efficacy of the Zenith Spiral-Z limb deployed in the EIA.Methods and R...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation Journal 2020/09/25, Vol.84(10), pp.1764-1770
Hauptverfasser: Fujimura, Naoki, Imazuru, Tomohiro, Matsumura, Hitoshi, Shibata, Tsuyoshi, Furuyama, Tadashi, Kaneko, Kenjiro, Uchiyama, Hidetoshi, Morikage, Noriyasu, Uchida, Takayuki, Teshima, Eiichi, Yamaoka, Terutoshi, Masuhara, Hiroshi, Ueda, Hideki, Arakawa, Mamoru, Norimatsu, Togo, Obara, Hideaki, Onitsuka, Seiji
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background:Limited data is available on the use of a polyester graft limb with a helical stent configuration deployed in the external iliac artery (EIA) during endovascular aneurysm repair (EVAR), so we prospectively analyzed the efficacy of the Zenith Spiral-Z limb deployed in the EIA.Methods and Results:Patients undergoing EVAR using a Zenith stent-graft and Spiral-Z limb deployed in the EIA were prospectively registered in 24 Japanese institutions from June 2017 to November 2017. In total, 65 patients (74 limbs) (mean age: 77.1±8.0 years, 87.7% men, mean abdominal aortic aneurysm (AAA) diameter: 51.9±7.2 mm, mean iliac artery aneurysm (IAA) diameter: 38.3±10.0 mm) were registered and followed up. The most common reason for deployment in the EIA was a common IAA (43 limbs, 58.1%), and 8 limbs (10.8%) had a bare nitinol stent placed at the Spiral-Z limb. A total of 61 patients (70 limbs) completed a 24-month follow-up. There were 2 Spiral-Z limb stenoses and 1 occlusion, leading to a primary patency of 95.5% and a secondary patency of 100%, at 24 months. Buttock claudication occurred in 24.3% of the limbs treated at 1 month but decreased to 4.3% at 24 months.Conclusions:Our multicenter prospective study showed that Spiral-Z limb deployed in the EIA was associated with satisfactory results and seems to be a durable option, even in the era of iliac branch devices.
ISSN:1346-9843
1347-4820
1347-4820
DOI:10.1253/circj.CJ-20-0195