Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss

PURPOSETo verify the speech perception in subjects with ear malformation and unilateral hearing loss, fitted with two types of amplification as follows: conventional hearing aids and softband (band with vibrator bone). METHODThe study included fifteen subjects of both sexes who presented congenital...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:CoDAS (São Paulo) 2020-01, Vol.32 (4), p.e20190047-e20190047
Hauptverfasser: Matos, Izabella Lima de, Ferreira, Maria Carolina, Mondelli, Maria Fernanda Capoani Garcia
Format: Artikel
Sprache:eng ; por
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e20190047
container_issue 4
container_start_page e20190047
container_title CoDAS (São Paulo)
container_volume 32
creator Matos, Izabella Lima de
Ferreira, Maria Carolina
Mondelli, Maria Fernanda Capoani Garcia
description PURPOSETo verify the speech perception in subjects with ear malformation and unilateral hearing loss, fitted with two types of amplification as follows: conventional hearing aids and softband (band with vibrator bone). METHODThe study included fifteen subjects of both sexes who presented congenital malformation of the middle or outer ear, diagnosed with unilateral conductive or mixed hearing loss, moderate to severe hearing loss, age range between 15 to 25 years and, prescription from a specialist doctor for hearing device fitting. We performed the speech perception assessment without amplification after the hearing aid and softband fitting, with the hearing aid linked to the bone vibrator (conventional) and the softband (band with the bone vibrator). The subjects were evaluated using the Hearing in Noise Test (HINT), in silence and in noise. RESULTSSeven subjects with unilateral ear malformation were evaluated, 57.1 % had impairment in the right ear and 42.9 % in the left ear. Regarding the type and the level of hearing loss, 71 % of all subjects included in the sample presented moderate conductive hearing loss. The assessment of speech perception was performed during silence, frontal noise, lateral noise and, during three specifics situations: no amplification, with conventional hearing aid and with the softband. The results with the amplification devices were positive in all evaluated conditions. CONCLUSIONEvaluated subjects presented improvement in speech perception, in silence, frontal noise and lateral noise situations, regardless of the type of amplification; however, the difference was not statistically significant.
doi_str_mv 10.1590/2317-1782/20202019047
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_2430978573</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2430978573</sourcerecordid><originalsourceid>FETCH-LOGICAL-p188t-675fb2a09ad3a701bca732d3a62d3660554a38fe3eb9338438bbcbda8b07b2883</originalsourceid><addsrcrecordid>eNo9jFtLw0AUhBdBsNT-BGEffYndS5LdPJbiDQq-6HM5uzmxWzabmJNU_PdWIzIwMwwfw9iNFHeyqMRaaWkyaaxaK_EjWYncXLDF_37FVkRHIYSUqtC5WLDTJkH8okC8azj1iP7Aexw89mPoEv8M44FD28fQBA-_U42n4JF4SJwmd0Q_0owhDLyF2HRDO5OQaj6lEGHEASI_nIGQ3nnsiK7ZZQORcPWXS_b2cP-6fcp2L4_P280u66W1Y1aaonEKRAW1BiOk82C0OvfybGUpiiIHbRvU6Cqtba6tc97VYJ0wTlmrl-x2_u2H7mNCGvdtII8xQsJuor3KtaiMLYzW3_B7YgI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2430978573</pqid></control><display><type>article</type><title>Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss</title><source>DOAJ Directory of Open Access Journals</source><creator>Matos, Izabella Lima de ; Ferreira, Maria Carolina ; Mondelli, Maria Fernanda Capoani Garcia</creator><creatorcontrib>Matos, Izabella Lima de ; Ferreira, Maria Carolina ; Mondelli, Maria Fernanda Capoani Garcia</creatorcontrib><description>PURPOSETo verify the speech perception in subjects with ear malformation and unilateral hearing loss, fitted with two types of amplification as follows: conventional hearing aids and softband (band with vibrator bone). METHODThe study included fifteen subjects of both sexes who presented congenital malformation of the middle or outer ear, diagnosed with unilateral conductive or mixed hearing loss, moderate to severe hearing loss, age range between 15 to 25 years and, prescription from a specialist doctor for hearing device fitting. We performed the speech perception assessment without amplification after the hearing aid and softband fitting, with the hearing aid linked to the bone vibrator (conventional) and the softband (band with the bone vibrator). The subjects were evaluated using the Hearing in Noise Test (HINT), in silence and in noise. RESULTSSeven subjects with unilateral ear malformation were evaluated, 57.1 % had impairment in the right ear and 42.9 % in the left ear. Regarding the type and the level of hearing loss, 71 % of all subjects included in the sample presented moderate conductive hearing loss. The assessment of speech perception was performed during silence, frontal noise, lateral noise and, during three specifics situations: no amplification, with conventional hearing aid and with the softband. The results with the amplification devices were positive in all evaluated conditions. CONCLUSIONEvaluated subjects presented improvement in speech perception, in silence, frontal noise and lateral noise situations, regardless of the type of amplification; however, the difference was not statistically significant.</description><identifier>EISSN: 2317-1782</identifier><identifier>DOI: 10.1590/2317-1782/20202019047</identifier><language>eng ; por</language><ispartof>CoDAS (São Paulo), 2020-01, Vol.32 (4), p.e20190047-e20190047</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,862,27907,27908</link.rule.ids></links><search><creatorcontrib>Matos, Izabella Lima de</creatorcontrib><creatorcontrib>Ferreira, Maria Carolina</creatorcontrib><creatorcontrib>Mondelli, Maria Fernanda Capoani Garcia</creatorcontrib><title>Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss</title><title>CoDAS (São Paulo)</title><description>PURPOSETo verify the speech perception in subjects with ear malformation and unilateral hearing loss, fitted with two types of amplification as follows: conventional hearing aids and softband (band with vibrator bone). METHODThe study included fifteen subjects of both sexes who presented congenital malformation of the middle or outer ear, diagnosed with unilateral conductive or mixed hearing loss, moderate to severe hearing loss, age range between 15 to 25 years and, prescription from a specialist doctor for hearing device fitting. We performed the speech perception assessment without amplification after the hearing aid and softband fitting, with the hearing aid linked to the bone vibrator (conventional) and the softband (band with the bone vibrator). The subjects were evaluated using the Hearing in Noise Test (HINT), in silence and in noise. RESULTSSeven subjects with unilateral ear malformation were evaluated, 57.1 % had impairment in the right ear and 42.9 % in the left ear. Regarding the type and the level of hearing loss, 71 % of all subjects included in the sample presented moderate conductive hearing loss. The assessment of speech perception was performed during silence, frontal noise, lateral noise and, during three specifics situations: no amplification, with conventional hearing aid and with the softband. The results with the amplification devices were positive in all evaluated conditions. CONCLUSIONEvaluated subjects presented improvement in speech perception, in silence, frontal noise and lateral noise situations, regardless of the type of amplification; however, the difference was not statistically significant.</description><issn>2317-1782</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNo9jFtLw0AUhBdBsNT-BGEffYndS5LdPJbiDQq-6HM5uzmxWzabmJNU_PdWIzIwMwwfw9iNFHeyqMRaaWkyaaxaK_EjWYncXLDF_37FVkRHIYSUqtC5WLDTJkH8okC8azj1iP7Aexw89mPoEv8M44FD28fQBA-_U42n4JF4SJwmd0Q_0owhDLyF2HRDO5OQaj6lEGHEASI_nIGQ3nnsiK7ZZQORcPWXS_b2cP-6fcp2L4_P280u66W1Y1aaonEKRAW1BiOk82C0OvfybGUpiiIHbRvU6Cqtba6tc97VYJ0wTlmrl-x2_u2H7mNCGvdtII8xQsJuor3KtaiMLYzW3_B7YgI</recordid><startdate>20200101</startdate><enddate>20200101</enddate><creator>Matos, Izabella Lima de</creator><creator>Ferreira, Maria Carolina</creator><creator>Mondelli, Maria Fernanda Capoani Garcia</creator><scope>7X8</scope></search><sort><creationdate>20200101</creationdate><title>Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss</title><author>Matos, Izabella Lima de ; Ferreira, Maria Carolina ; Mondelli, Maria Fernanda Capoani Garcia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p188t-675fb2a09ad3a701bca732d3a62d3660554a38fe3eb9338438bbcbda8b07b2883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; por</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Matos, Izabella Lima de</creatorcontrib><creatorcontrib>Ferreira, Maria Carolina</creatorcontrib><creatorcontrib>Mondelli, Maria Fernanda Capoani Garcia</creatorcontrib><collection>MEDLINE - Academic</collection><jtitle>CoDAS (São Paulo)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Matos, Izabella Lima de</au><au>Ferreira, Maria Carolina</au><au>Mondelli, Maria Fernanda Capoani Garcia</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss</atitle><jtitle>CoDAS (São Paulo)</jtitle><date>2020-01-01</date><risdate>2020</risdate><volume>32</volume><issue>4</issue><spage>e20190047</spage><epage>e20190047</epage><pages>e20190047-e20190047</pages><eissn>2317-1782</eissn><abstract>PURPOSETo verify the speech perception in subjects with ear malformation and unilateral hearing loss, fitted with two types of amplification as follows: conventional hearing aids and softband (band with vibrator bone). METHODThe study included fifteen subjects of both sexes who presented congenital malformation of the middle or outer ear, diagnosed with unilateral conductive or mixed hearing loss, moderate to severe hearing loss, age range between 15 to 25 years and, prescription from a specialist doctor for hearing device fitting. We performed the speech perception assessment without amplification after the hearing aid and softband fitting, with the hearing aid linked to the bone vibrator (conventional) and the softband (band with the bone vibrator). The subjects were evaluated using the Hearing in Noise Test (HINT), in silence and in noise. RESULTSSeven subjects with unilateral ear malformation were evaluated, 57.1 % had impairment in the right ear and 42.9 % in the left ear. Regarding the type and the level of hearing loss, 71 % of all subjects included in the sample presented moderate conductive hearing loss. The assessment of speech perception was performed during silence, frontal noise, lateral noise and, during three specifics situations: no amplification, with conventional hearing aid and with the softband. The results with the amplification devices were positive in all evaluated conditions. CONCLUSIONEvaluated subjects presented improvement in speech perception, in silence, frontal noise and lateral noise situations, regardless of the type of amplification; however, the difference was not statistically significant.</abstract><doi>10.1590/2317-1782/20202019047</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2317-1782
ispartof CoDAS (São Paulo), 2020-01, Vol.32 (4), p.e20190047-e20190047
issn 2317-1782
language eng ; por
recordid cdi_proquest_miscellaneous_2430978573
source DOAJ Directory of Open Access Journals
title Analysis of speech perception with amplification devices in subjects with ear malformation and unilateral hearing loss
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T21%3A59%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20speech%20perception%20with%20amplification%20devices%20in%20subjects%20with%20ear%20malformation%20and%20unilateral%20hearing%20loss&rft.jtitle=CoDAS%20(Sa%CC%83o%20Paulo)&rft.au=Matos,%20Izabella%20Lima%20de&rft.date=2020-01-01&rft.volume=32&rft.issue=4&rft.spage=e20190047&rft.epage=e20190047&rft.pages=e20190047-e20190047&rft.eissn=2317-1782&rft_id=info:doi/10.1590/2317-1782/20202019047&rft_dat=%3Cproquest%3E2430978573%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2430978573&rft_id=info:pmid/&rfr_iscdi=true