Safety and feasibility of same-day discharge after esophageal endoscopic submucosal dissection

Endoscopic submucosal dissection (ESD) is used for treating early luminal GI cancers. ESD is the standard of care in Asia, where it results in multiday admissions for observation. The goal of our study was to evaluate the safety and feasibility of same-day discharge (SDD) after ESD. This is a retros...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2021-04, Vol.93 (4), p.853-860
Hauptverfasser: Hanada, Yuri, Wang, Kenneth K.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 860
container_issue 4
container_start_page 853
container_title Gastrointestinal endoscopy
container_volume 93
creator Hanada, Yuri
Wang, Kenneth K.
description Endoscopic submucosal dissection (ESD) is used for treating early luminal GI cancers. ESD is the standard of care in Asia, where it results in multiday admissions for observation. The goal of our study was to evaluate the safety and feasibility of same-day discharge (SDD) after ESD. This is a retrospective cohort study of adults who underwent similar esophageal ESD with a Clutch Cutter device (DP2618DT; Fujifilm) at the Mayo Clinic (Rochester, Minn, USA) from 2017 to 2019 with a single endoscopist. The primary end point was postprocedural adverse events within 7 days of ESD. Of 96 patients (75% male, mean age, 70 ± 10.3 years) undergoing a total of 140 ESDs, 85 were SDD versus 55 admissions. Of the 55 admits, 53 were discharged within 24 hours, whereas 2 were admitted for 2 to 3 days for reasons unrelated to the ESD procedure. Admissions were more likely to have a history of antiplatelet/anticoagulant use (56.4% vs 34.1%; P = .01) and higher mean American Society of Anesthesiologists (ASA) score (3.2 vs 2.9; P = .007). Admissions had larger resections (28.6 vs 20.1 mm; P < .0001) with longer procedural durations (103.4 vs 62 minutes; P < .0001). Among SDDs, no intraprocedural or postprocedural adverse events were seen. Among admissions, 1 (1.8% vs 0%; P = .39) experienced intraprocedural bleeding requiring endoscopic intervention, 1 required transfusion before discharge within 24 hours of ESD (1.8% vs 0%; P = .39), and 1 required rehospitalization and endoscopic intervention within 7 days to address an active bleed along the resection margin (1.8% vs 0%; P = .39). SDD after esophageal ESD is safe and feasible. An experienced endoscopist can determine if SDD can be considered in patients with ASA physical classification status ≤2 who undergo resections off antiplatelet/anticoagulant therapy and do not experience intraprocedural adverse events.
doi_str_mv 10.1016/j.gie.2020.07.037
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2428555288</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0016510720346320</els_id><sourcerecordid>2428555288</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-f0a93f3c738b29efb72fb2262143d8c9c24c1ddb5b5c50ccb678a862e136d4dc3</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRS0EoqXwAWxQlmwS_GjiRKwQ4iVVYgFssZzxuHWVxsVOkfr3uGphycoa69yrmUPIJaMFo6y6WRZzhwWnnBZUFlTIIzJmtJF5JWVzTMY0QXnJqByRsxiXlNKaC3ZKRoJLzqYNG5PPN21x2Ga6N5lFHV3rOpdmb7OoV5gbvc2Mi7DQYY6ZtgOGDKNfL_QcdZdhb3wEv3aQxU272oCP6TcFIsLgfH9OTqzuIl4c3gn5eHx4v3_OZ69PL_d3sxxEKYbcUt0IK0CKuuUN2lZy23JepSWFqaEBPgVmTFu2JZQUoK1kreuKIxOVmRoQE3K9710H_7XBOKhVWhq7TvfoN1HxKa_LsuR1nVC2RyH4GANatQ5upcNWMap2WtVSJa1qp1VRqZLWlLk61Kcj0fwlfj0m4HYPYDry22FQERz2gMaFZEIZ7_6p_wFdHomx</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2428555288</pqid></control><display><type>article</type><title>Safety and feasibility of same-day discharge after esophageal endoscopic submucosal dissection</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Hanada, Yuri ; Wang, Kenneth K.</creator><creatorcontrib>Hanada, Yuri ; Wang, Kenneth K.</creatorcontrib><description>Endoscopic submucosal dissection (ESD) is used for treating early luminal GI cancers. ESD is the standard of care in Asia, where it results in multiday admissions for observation. The goal of our study was to evaluate the safety and feasibility of same-day discharge (SDD) after ESD. This is a retrospective cohort study of adults who underwent similar esophageal ESD with a Clutch Cutter device (DP2618DT; Fujifilm) at the Mayo Clinic (Rochester, Minn, USA) from 2017 to 2019 with a single endoscopist. The primary end point was postprocedural adverse events within 7 days of ESD. Of 96 patients (75% male, mean age, 70 ± 10.3 years) undergoing a total of 140 ESDs, 85 were SDD versus 55 admissions. Of the 55 admits, 53 were discharged within 24 hours, whereas 2 were admitted for 2 to 3 days for reasons unrelated to the ESD procedure. Admissions were more likely to have a history of antiplatelet/anticoagulant use (56.4% vs 34.1%; P = .01) and higher mean American Society of Anesthesiologists (ASA) score (3.2 vs 2.9; P = .007). Admissions had larger resections (28.6 vs 20.1 mm; P &lt; .0001) with longer procedural durations (103.4 vs 62 minutes; P &lt; .0001). Among SDDs, no intraprocedural or postprocedural adverse events were seen. Among admissions, 1 (1.8% vs 0%; P = .39) experienced intraprocedural bleeding requiring endoscopic intervention, 1 required transfusion before discharge within 24 hours of ESD (1.8% vs 0%; P = .39), and 1 required rehospitalization and endoscopic intervention within 7 days to address an active bleed along the resection margin (1.8% vs 0%; P = .39). SDD after esophageal ESD is safe and feasible. An experienced endoscopist can determine if SDD can be considered in patients with ASA physical classification status ≤2 who undergo resections off antiplatelet/anticoagulant therapy and do not experience intraprocedural adverse events.</description><identifier>ISSN: 0016-5107</identifier><identifier>EISSN: 1097-6779</identifier><identifier>DOI: 10.1016/j.gie.2020.07.037</identifier><identifier>PMID: 32721491</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>Gastrointestinal endoscopy, 2021-04, Vol.93 (4), p.853-860</ispartof><rights>2021 American Society for Gastrointestinal Endoscopy</rights><rights>Copyright © 2021 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-f0a93f3c738b29efb72fb2262143d8c9c24c1ddb5b5c50ccb678a862e136d4dc3</citedby><cites>FETCH-LOGICAL-c353t-f0a93f3c738b29efb72fb2262143d8c9c24c1ddb5b5c50ccb678a862e136d4dc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.gie.2020.07.037$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3549,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32721491$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hanada, Yuri</creatorcontrib><creatorcontrib>Wang, Kenneth K.</creatorcontrib><title>Safety and feasibility of same-day discharge after esophageal endoscopic submucosal dissection</title><title>Gastrointestinal endoscopy</title><addtitle>Gastrointest Endosc</addtitle><description>Endoscopic submucosal dissection (ESD) is used for treating early luminal GI cancers. ESD is the standard of care in Asia, where it results in multiday admissions for observation. The goal of our study was to evaluate the safety and feasibility of same-day discharge (SDD) after ESD. This is a retrospective cohort study of adults who underwent similar esophageal ESD with a Clutch Cutter device (DP2618DT; Fujifilm) at the Mayo Clinic (Rochester, Minn, USA) from 2017 to 2019 with a single endoscopist. The primary end point was postprocedural adverse events within 7 days of ESD. Of 96 patients (75% male, mean age, 70 ± 10.3 years) undergoing a total of 140 ESDs, 85 were SDD versus 55 admissions. Of the 55 admits, 53 were discharged within 24 hours, whereas 2 were admitted for 2 to 3 days for reasons unrelated to the ESD procedure. Admissions were more likely to have a history of antiplatelet/anticoagulant use (56.4% vs 34.1%; P = .01) and higher mean American Society of Anesthesiologists (ASA) score (3.2 vs 2.9; P = .007). Admissions had larger resections (28.6 vs 20.1 mm; P &lt; .0001) with longer procedural durations (103.4 vs 62 minutes; P &lt; .0001). Among SDDs, no intraprocedural or postprocedural adverse events were seen. Among admissions, 1 (1.8% vs 0%; P = .39) experienced intraprocedural bleeding requiring endoscopic intervention, 1 required transfusion before discharge within 24 hours of ESD (1.8% vs 0%; P = .39), and 1 required rehospitalization and endoscopic intervention within 7 days to address an active bleed along the resection margin (1.8% vs 0%; P = .39). SDD after esophageal ESD is safe and feasible. An experienced endoscopist can determine if SDD can be considered in patients with ASA physical classification status ≤2 who undergo resections off antiplatelet/anticoagulant therapy and do not experience intraprocedural adverse events.</description><issn>0016-5107</issn><issn>1097-6779</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kMtOwzAQRS0EoqXwAWxQlmwS_GjiRKwQ4iVVYgFssZzxuHWVxsVOkfr3uGphycoa69yrmUPIJaMFo6y6WRZzhwWnnBZUFlTIIzJmtJF5JWVzTMY0QXnJqByRsxiXlNKaC3ZKRoJLzqYNG5PPN21x2Ga6N5lFHV3rOpdmb7OoV5gbvc2Mi7DQYY6ZtgOGDKNfL_QcdZdhb3wEv3aQxU272oCP6TcFIsLgfH9OTqzuIl4c3gn5eHx4v3_OZ69PL_d3sxxEKYbcUt0IK0CKuuUN2lZy23JepSWFqaEBPgVmTFu2JZQUoK1kreuKIxOVmRoQE3K9710H_7XBOKhVWhq7TvfoN1HxKa_LsuR1nVC2RyH4GANatQ5upcNWMap2WtVSJa1qp1VRqZLWlLk61Kcj0fwlfj0m4HYPYDry22FQERz2gMaFZEIZ7_6p_wFdHomx</recordid><startdate>202104</startdate><enddate>202104</enddate><creator>Hanada, Yuri</creator><creator>Wang, Kenneth K.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202104</creationdate><title>Safety and feasibility of same-day discharge after esophageal endoscopic submucosal dissection</title><author>Hanada, Yuri ; Wang, Kenneth K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-f0a93f3c738b29efb72fb2262143d8c9c24c1ddb5b5c50ccb678a862e136d4dc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hanada, Yuri</creatorcontrib><creatorcontrib>Wang, Kenneth K.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Gastrointestinal endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hanada, Yuri</au><au>Wang, Kenneth K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Safety and feasibility of same-day discharge after esophageal endoscopic submucosal dissection</atitle><jtitle>Gastrointestinal endoscopy</jtitle><addtitle>Gastrointest Endosc</addtitle><date>2021-04</date><risdate>2021</risdate><volume>93</volume><issue>4</issue><spage>853</spage><epage>860</epage><pages>853-860</pages><issn>0016-5107</issn><eissn>1097-6779</eissn><abstract>Endoscopic submucosal dissection (ESD) is used for treating early luminal GI cancers. ESD is the standard of care in Asia, where it results in multiday admissions for observation. The goal of our study was to evaluate the safety and feasibility of same-day discharge (SDD) after ESD. This is a retrospective cohort study of adults who underwent similar esophageal ESD with a Clutch Cutter device (DP2618DT; Fujifilm) at the Mayo Clinic (Rochester, Minn, USA) from 2017 to 2019 with a single endoscopist. The primary end point was postprocedural adverse events within 7 days of ESD. Of 96 patients (75% male, mean age, 70 ± 10.3 years) undergoing a total of 140 ESDs, 85 were SDD versus 55 admissions. Of the 55 admits, 53 were discharged within 24 hours, whereas 2 were admitted for 2 to 3 days for reasons unrelated to the ESD procedure. Admissions were more likely to have a history of antiplatelet/anticoagulant use (56.4% vs 34.1%; P = .01) and higher mean American Society of Anesthesiologists (ASA) score (3.2 vs 2.9; P = .007). Admissions had larger resections (28.6 vs 20.1 mm; P &lt; .0001) with longer procedural durations (103.4 vs 62 minutes; P &lt; .0001). Among SDDs, no intraprocedural or postprocedural adverse events were seen. Among admissions, 1 (1.8% vs 0%; P = .39) experienced intraprocedural bleeding requiring endoscopic intervention, 1 required transfusion before discharge within 24 hours of ESD (1.8% vs 0%; P = .39), and 1 required rehospitalization and endoscopic intervention within 7 days to address an active bleed along the resection margin (1.8% vs 0%; P = .39). SDD after esophageal ESD is safe and feasible. An experienced endoscopist can determine if SDD can be considered in patients with ASA physical classification status ≤2 who undergo resections off antiplatelet/anticoagulant therapy and do not experience intraprocedural adverse events.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32721491</pmid><doi>10.1016/j.gie.2020.07.037</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0016-5107
ispartof Gastrointestinal endoscopy, 2021-04, Vol.93 (4), p.853-860
issn 0016-5107
1097-6779
language eng
recordid cdi_proquest_miscellaneous_2428555288
source ScienceDirect Journals (5 years ago - present)
title Safety and feasibility of same-day discharge after esophageal endoscopic submucosal dissection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T16%3A47%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Safety%20and%20feasibility%20of%20same-day%20discharge%20after%20esophageal%20endoscopic%20submucosal%20dissection&rft.jtitle=Gastrointestinal%20endoscopy&rft.au=Hanada,%20Yuri&rft.date=2021-04&rft.volume=93&rft.issue=4&rft.spage=853&rft.epage=860&rft.pages=853-860&rft.issn=0016-5107&rft.eissn=1097-6779&rft_id=info:doi/10.1016/j.gie.2020.07.037&rft_dat=%3Cproquest_cross%3E2428555288%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2428555288&rft_id=info:pmid/32721491&rft_els_id=S0016510720346320&rfr_iscdi=true