An alternative procedure to leukapheresis for peripheral hematopoietic progenitor cell collection in very‐low‐weight children: A single pediatric center experience
Background PBSC collection using a blood cell separator in very low weight patients can be frequently complicated by severe adverse effects and technical difficulties. Material and Methods From March 2013 to January 2017, 14 PBSC collections were performed in 12 children weighing less than 10 kg, af...
Gespeichert in:
Veröffentlicht in: | Journal of clinical apheresis 2020-09, Vol.35 (5), p.406-412 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 412 |
---|---|
container_issue | 5 |
container_start_page | 406 |
container_title | Journal of clinical apheresis |
container_volume | 35 |
creator | Becherucci, Valentina Ermini, Stefano Piccini, Luisa Bisin, Silvia Gori, Valentina Gentile, Francesca Ceccantini, Riccardo De Rienzo, Elena Bindi, Barbara Pavan, Paola Cunial, Vanessa Allegro, Elisa Brugnolo, Francesca Maggio, Daniela Calzolari, Daniela Maccarelli, Erika Galli, Silvia Muricci, Sonia Berchielli, Marco Tintori, Veronica Sardi, Iacopo Bambi, Franco |
description | Background
PBSC collection using a blood cell separator in very low weight patients can be frequently complicated by severe adverse effects and technical difficulties.
Material and Methods
From March 2013 to January 2017, 14 PBSC collections were performed in 12 children weighing less than 10 kg, affected by different solid tumours. PBSC collection was performed with a “homemade” aseptically assembled circuit. The circuit is composed by a 150 mL collection bag connected with a 4 stopcock ramp, perfused with ACD. This circuit allows collection of a specific total blood amount from CVC, depending on CD34+/kg target.
Results
Mean CD34+cell performance per collection was 9.3 × 106/kg. Tolerance to the procedure was very good as none of the patients experienced complications, with the exception of a patient who showed mild cyanosis and pallor after collection. Moreover, no bleeding or thrombotic complications have been observed. To date, 16 PBSC reinfusions have been performed in 7 children with a mean CD34+ cells viability of 98.1% ± 2.7 and mean WBC viability of 57% ± 10. Cell recovery after thawing was 87% ± 10.8. A rapid graft intake for both neutrophils and platelets, between day 7 and 20 after reinfusion was observed.
Discussion
The procedure of total blood collection without the use of a cell separator is feasible and allows a good PBSC collection without significant side effects in very low‐weight children. Moreover, this method could represent a valid and safe alternative to leukapheresis in patients where classic procedure could be difficult to apply. |
doi_str_mv | 10.1002/jca.21813 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2427293606</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2444300449</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3533-1bf1aec969075cf6c7b760386083ea51e283fb7064f80fa8ce23a3dfb58a152b3</originalsourceid><addsrcrecordid>eNp1kcuOFCEUhonROO3owhcwJG7GRc8coC6Uu07H8ZJJ3Oi6QlGnumlpKIGatnfzCL6F7-WTSNmjCxM3kJCP7_DzE_KcwSUD4Fc7rS45k0w8IAsGjVwyBuwhWUAtxJIXZXNGnsS4A4CmEeVjciZ4zUBCuSA_Vo4qmzA4lcwt0jF4jf0UkCZPLU5f1LjFgNFEOvhARwxmPlCWbnGvkh-9wWT0fG-DzqTMaLSWam8t6mS8o8bRWwzHn3ffrT_k9YBms01Ub43tA7rXdEWjcRubh2NvVApZp9HlN1H8Ng9Ep_EpeTQoG_HZ_X5OPl-_-bR-t7z5-Pb9enWz1KLMYVk3MIW6qRqoSz1Uuu7qCoSsQApUJUMuxdDVUBWDhEFJjVwo0Q9dKRUreSfOycXJmwN9nTCmdm_inEg59FNsecFr3ogKqoy-_Afd-Sn_o52pohAARdFk6tWJ0sHHGHBox2D2KhxbBu3cXpvba3-3l9kX98ap22P_l_xTVwauTsDBWDz-39R-WK9Oyl9dS6lI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2444300449</pqid></control><display><type>article</type><title>An alternative procedure to leukapheresis for peripheral hematopoietic progenitor cell collection in very‐low‐weight children: A single pediatric center experience</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Becherucci, Valentina ; Ermini, Stefano ; Piccini, Luisa ; Bisin, Silvia ; Gori, Valentina ; Gentile, Francesca ; Ceccantini, Riccardo ; De Rienzo, Elena ; Bindi, Barbara ; Pavan, Paola ; Cunial, Vanessa ; Allegro, Elisa ; Brugnolo, Francesca ; Maggio, Daniela ; Calzolari, Daniela ; Maccarelli, Erika ; Galli, Silvia ; Muricci, Sonia ; Berchielli, Marco ; Tintori, Veronica ; Sardi, Iacopo ; Bambi, Franco</creator><creatorcontrib>Becherucci, Valentina ; Ermini, Stefano ; Piccini, Luisa ; Bisin, Silvia ; Gori, Valentina ; Gentile, Francesca ; Ceccantini, Riccardo ; De Rienzo, Elena ; Bindi, Barbara ; Pavan, Paola ; Cunial, Vanessa ; Allegro, Elisa ; Brugnolo, Francesca ; Maggio, Daniela ; Calzolari, Daniela ; Maccarelli, Erika ; Galli, Silvia ; Muricci, Sonia ; Berchielli, Marco ; Tintori, Veronica ; Sardi, Iacopo ; Bambi, Franco</creatorcontrib><description>Background
PBSC collection using a blood cell separator in very low weight patients can be frequently complicated by severe adverse effects and technical difficulties.
Material and Methods
From March 2013 to January 2017, 14 PBSC collections were performed in 12 children weighing less than 10 kg, affected by different solid tumours. PBSC collection was performed with a “homemade” aseptically assembled circuit. The circuit is composed by a 150 mL collection bag connected with a 4 stopcock ramp, perfused with ACD. This circuit allows collection of a specific total blood amount from CVC, depending on CD34+/kg target.
Results
Mean CD34+cell performance per collection was 9.3 × 106/kg. Tolerance to the procedure was very good as none of the patients experienced complications, with the exception of a patient who showed mild cyanosis and pallor after collection. Moreover, no bleeding or thrombotic complications have been observed. To date, 16 PBSC reinfusions have been performed in 7 children with a mean CD34+ cells viability of 98.1% ± 2.7 and mean WBC viability of 57% ± 10. Cell recovery after thawing was 87% ± 10.8. A rapid graft intake for both neutrophils and platelets, between day 7 and 20 after reinfusion was observed.
Discussion
The procedure of total blood collection without the use of a cell separator is feasible and allows a good PBSC collection without significant side effects in very low‐weight children. Moreover, this method could represent a valid and safe alternative to leukapheresis in patients where classic procedure could be difficult to apply.</description><identifier>ISSN: 0733-2459</identifier><identifier>EISSN: 1098-1101</identifier><identifier>DOI: 10.1002/jca.21813</identifier><identifier>PMID: 32710805</identifier><language>eng</language><publisher>Hoboken, USA: John Wiley & Sons, Inc</publisher><subject>autologous transplantation ; Blood ; bloodletting procedure ; CD34 ; infants ; leukapheresis procedure ; Leukemia ; Pediatrics ; peripheral blood stem cell collection ; Stem cells</subject><ispartof>Journal of clinical apheresis, 2020-09, Vol.35 (5), p.406-412</ispartof><rights>2020 Wiley Periodicals LLC</rights><rights>2020 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3533-1bf1aec969075cf6c7b760386083ea51e283fb7064f80fa8ce23a3dfb58a152b3</citedby><cites>FETCH-LOGICAL-c3533-1bf1aec969075cf6c7b760386083ea51e283fb7064f80fa8ce23a3dfb58a152b3</cites><orcidid>0000-0002-1945-8324 ; 0000-0002-2711-0088</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjca.21813$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjca.21813$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32710805$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Becherucci, Valentina</creatorcontrib><creatorcontrib>Ermini, Stefano</creatorcontrib><creatorcontrib>Piccini, Luisa</creatorcontrib><creatorcontrib>Bisin, Silvia</creatorcontrib><creatorcontrib>Gori, Valentina</creatorcontrib><creatorcontrib>Gentile, Francesca</creatorcontrib><creatorcontrib>Ceccantini, Riccardo</creatorcontrib><creatorcontrib>De Rienzo, Elena</creatorcontrib><creatorcontrib>Bindi, Barbara</creatorcontrib><creatorcontrib>Pavan, Paola</creatorcontrib><creatorcontrib>Cunial, Vanessa</creatorcontrib><creatorcontrib>Allegro, Elisa</creatorcontrib><creatorcontrib>Brugnolo, Francesca</creatorcontrib><creatorcontrib>Maggio, Daniela</creatorcontrib><creatorcontrib>Calzolari, Daniela</creatorcontrib><creatorcontrib>Maccarelli, Erika</creatorcontrib><creatorcontrib>Galli, Silvia</creatorcontrib><creatorcontrib>Muricci, Sonia</creatorcontrib><creatorcontrib>Berchielli, Marco</creatorcontrib><creatorcontrib>Tintori, Veronica</creatorcontrib><creatorcontrib>Sardi, Iacopo</creatorcontrib><creatorcontrib>Bambi, Franco</creatorcontrib><title>An alternative procedure to leukapheresis for peripheral hematopoietic progenitor cell collection in very‐low‐weight children: A single pediatric center experience</title><title>Journal of clinical apheresis</title><addtitle>J Clin Apher</addtitle><description>Background
PBSC collection using a blood cell separator in very low weight patients can be frequently complicated by severe adverse effects and technical difficulties.
Material and Methods
From March 2013 to January 2017, 14 PBSC collections were performed in 12 children weighing less than 10 kg, affected by different solid tumours. PBSC collection was performed with a “homemade” aseptically assembled circuit. The circuit is composed by a 150 mL collection bag connected with a 4 stopcock ramp, perfused with ACD. This circuit allows collection of a specific total blood amount from CVC, depending on CD34+/kg target.
Results
Mean CD34+cell performance per collection was 9.3 × 106/kg. Tolerance to the procedure was very good as none of the patients experienced complications, with the exception of a patient who showed mild cyanosis and pallor after collection. Moreover, no bleeding or thrombotic complications have been observed. To date, 16 PBSC reinfusions have been performed in 7 children with a mean CD34+ cells viability of 98.1% ± 2.7 and mean WBC viability of 57% ± 10. Cell recovery after thawing was 87% ± 10.8. A rapid graft intake for both neutrophils and platelets, between day 7 and 20 after reinfusion was observed.
Discussion
The procedure of total blood collection without the use of a cell separator is feasible and allows a good PBSC collection without significant side effects in very low‐weight children. Moreover, this method could represent a valid and safe alternative to leukapheresis in patients where classic procedure could be difficult to apply.</description><subject>autologous transplantation</subject><subject>Blood</subject><subject>bloodletting procedure</subject><subject>CD34</subject><subject>infants</subject><subject>leukapheresis procedure</subject><subject>Leukemia</subject><subject>Pediatrics</subject><subject>peripheral blood stem cell collection</subject><subject>Stem cells</subject><issn>0733-2459</issn><issn>1098-1101</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp1kcuOFCEUhonROO3owhcwJG7GRc8coC6Uu07H8ZJJ3Oi6QlGnumlpKIGatnfzCL6F7-WTSNmjCxM3kJCP7_DzE_KcwSUD4Fc7rS45k0w8IAsGjVwyBuwhWUAtxJIXZXNGnsS4A4CmEeVjciZ4zUBCuSA_Vo4qmzA4lcwt0jF4jf0UkCZPLU5f1LjFgNFEOvhARwxmPlCWbnGvkh-9wWT0fG-DzqTMaLSWam8t6mS8o8bRWwzHn3ffrT_k9YBms01Ub43tA7rXdEWjcRubh2NvVApZp9HlN1H8Ng9Ep_EpeTQoG_HZ_X5OPl-_-bR-t7z5-Pb9enWz1KLMYVk3MIW6qRqoSz1Uuu7qCoSsQApUJUMuxdDVUBWDhEFJjVwo0Q9dKRUreSfOycXJmwN9nTCmdm_inEg59FNsecFr3ogKqoy-_Afd-Sn_o52pohAARdFk6tWJ0sHHGHBox2D2KhxbBu3cXpvba3-3l9kX98ap22P_l_xTVwauTsDBWDz-39R-WK9Oyl9dS6lI</recordid><startdate>202009</startdate><enddate>202009</enddate><creator>Becherucci, Valentina</creator><creator>Ermini, Stefano</creator><creator>Piccini, Luisa</creator><creator>Bisin, Silvia</creator><creator>Gori, Valentina</creator><creator>Gentile, Francesca</creator><creator>Ceccantini, Riccardo</creator><creator>De Rienzo, Elena</creator><creator>Bindi, Barbara</creator><creator>Pavan, Paola</creator><creator>Cunial, Vanessa</creator><creator>Allegro, Elisa</creator><creator>Brugnolo, Francesca</creator><creator>Maggio, Daniela</creator><creator>Calzolari, Daniela</creator><creator>Maccarelli, Erika</creator><creator>Galli, Silvia</creator><creator>Muricci, Sonia</creator><creator>Berchielli, Marco</creator><creator>Tintori, Veronica</creator><creator>Sardi, Iacopo</creator><creator>Bambi, Franco</creator><general>John Wiley & Sons, Inc</general><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1945-8324</orcidid><orcidid>https://orcid.org/0000-0002-2711-0088</orcidid></search><sort><creationdate>202009</creationdate><title>An alternative procedure to leukapheresis for peripheral hematopoietic progenitor cell collection in very‐low‐weight children: A single pediatric center experience</title><author>Becherucci, Valentina ; Ermini, Stefano ; Piccini, Luisa ; Bisin, Silvia ; Gori, Valentina ; Gentile, Francesca ; Ceccantini, Riccardo ; De Rienzo, Elena ; Bindi, Barbara ; Pavan, Paola ; Cunial, Vanessa ; Allegro, Elisa ; Brugnolo, Francesca ; Maggio, Daniela ; Calzolari, Daniela ; Maccarelli, Erika ; Galli, Silvia ; Muricci, Sonia ; Berchielli, Marco ; Tintori, Veronica ; Sardi, Iacopo ; Bambi, Franco</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3533-1bf1aec969075cf6c7b760386083ea51e283fb7064f80fa8ce23a3dfb58a152b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>autologous transplantation</topic><topic>Blood</topic><topic>bloodletting procedure</topic><topic>CD34</topic><topic>infants</topic><topic>leukapheresis procedure</topic><topic>Leukemia</topic><topic>Pediatrics</topic><topic>peripheral blood stem cell collection</topic><topic>Stem cells</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Becherucci, Valentina</creatorcontrib><creatorcontrib>Ermini, Stefano</creatorcontrib><creatorcontrib>Piccini, Luisa</creatorcontrib><creatorcontrib>Bisin, Silvia</creatorcontrib><creatorcontrib>Gori, Valentina</creatorcontrib><creatorcontrib>Gentile, Francesca</creatorcontrib><creatorcontrib>Ceccantini, Riccardo</creatorcontrib><creatorcontrib>De Rienzo, Elena</creatorcontrib><creatorcontrib>Bindi, Barbara</creatorcontrib><creatorcontrib>Pavan, Paola</creatorcontrib><creatorcontrib>Cunial, Vanessa</creatorcontrib><creatorcontrib>Allegro, Elisa</creatorcontrib><creatorcontrib>Brugnolo, Francesca</creatorcontrib><creatorcontrib>Maggio, Daniela</creatorcontrib><creatorcontrib>Calzolari, Daniela</creatorcontrib><creatorcontrib>Maccarelli, Erika</creatorcontrib><creatorcontrib>Galli, Silvia</creatorcontrib><creatorcontrib>Muricci, Sonia</creatorcontrib><creatorcontrib>Berchielli, Marco</creatorcontrib><creatorcontrib>Tintori, Veronica</creatorcontrib><creatorcontrib>Sardi, Iacopo</creatorcontrib><creatorcontrib>Bambi, Franco</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of clinical apheresis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Becherucci, Valentina</au><au>Ermini, Stefano</au><au>Piccini, Luisa</au><au>Bisin, Silvia</au><au>Gori, Valentina</au><au>Gentile, Francesca</au><au>Ceccantini, Riccardo</au><au>De Rienzo, Elena</au><au>Bindi, Barbara</au><au>Pavan, Paola</au><au>Cunial, Vanessa</au><au>Allegro, Elisa</au><au>Brugnolo, Francesca</au><au>Maggio, Daniela</au><au>Calzolari, Daniela</au><au>Maccarelli, Erika</au><au>Galli, Silvia</au><au>Muricci, Sonia</au><au>Berchielli, Marco</au><au>Tintori, Veronica</au><au>Sardi, Iacopo</au><au>Bambi, Franco</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An alternative procedure to leukapheresis for peripheral hematopoietic progenitor cell collection in very‐low‐weight children: A single pediatric center experience</atitle><jtitle>Journal of clinical apheresis</jtitle><addtitle>J Clin Apher</addtitle><date>2020-09</date><risdate>2020</risdate><volume>35</volume><issue>5</issue><spage>406</spage><epage>412</epage><pages>406-412</pages><issn>0733-2459</issn><eissn>1098-1101</eissn><abstract>Background
PBSC collection using a blood cell separator in very low weight patients can be frequently complicated by severe adverse effects and technical difficulties.
Material and Methods
From March 2013 to January 2017, 14 PBSC collections were performed in 12 children weighing less than 10 kg, affected by different solid tumours. PBSC collection was performed with a “homemade” aseptically assembled circuit. The circuit is composed by a 150 mL collection bag connected with a 4 stopcock ramp, perfused with ACD. This circuit allows collection of a specific total blood amount from CVC, depending on CD34+/kg target.
Results
Mean CD34+cell performance per collection was 9.3 × 106/kg. Tolerance to the procedure was very good as none of the patients experienced complications, with the exception of a patient who showed mild cyanosis and pallor after collection. Moreover, no bleeding or thrombotic complications have been observed. To date, 16 PBSC reinfusions have been performed in 7 children with a mean CD34+ cells viability of 98.1% ± 2.7 and mean WBC viability of 57% ± 10. Cell recovery after thawing was 87% ± 10.8. A rapid graft intake for both neutrophils and platelets, between day 7 and 20 after reinfusion was observed.
Discussion
The procedure of total blood collection without the use of a cell separator is feasible and allows a good PBSC collection without significant side effects in very low‐weight children. Moreover, this method could represent a valid and safe alternative to leukapheresis in patients where classic procedure could be difficult to apply.</abstract><cop>Hoboken, USA</cop><pub>John Wiley & Sons, Inc</pub><pmid>32710805</pmid><doi>10.1002/jca.21813</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-1945-8324</orcidid><orcidid>https://orcid.org/0000-0002-2711-0088</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0733-2459 |
ispartof | Journal of clinical apheresis, 2020-09, Vol.35 (5), p.406-412 |
issn | 0733-2459 1098-1101 |
language | eng |
recordid | cdi_proquest_miscellaneous_2427293606 |
source | Wiley Online Library Journals Frontfile Complete |
subjects | autologous transplantation Blood bloodletting procedure CD34 infants leukapheresis procedure Leukemia Pediatrics peripheral blood stem cell collection Stem cells |
title | An alternative procedure to leukapheresis for peripheral hematopoietic progenitor cell collection in very‐low‐weight children: A single pediatric center experience |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T23%3A52%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20alternative%20procedure%20to%20leukapheresis%20for%20peripheral%20hematopoietic%20progenitor%20cell%20collection%20in%20very%E2%80%90low%E2%80%90weight%20children:%20A%20single%20pediatric%20center%20experience&rft.jtitle=Journal%20of%20clinical%20apheresis&rft.au=Becherucci,%20Valentina&rft.date=2020-09&rft.volume=35&rft.issue=5&rft.spage=406&rft.epage=412&rft.pages=406-412&rft.issn=0733-2459&rft.eissn=1098-1101&rft_id=info:doi/10.1002/jca.21813&rft_dat=%3Cproquest_cross%3E2444300449%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2444300449&rft_id=info:pmid/32710805&rfr_iscdi=true |