Organ Care System Lung resulted in lower apoptosis and iNOS expression in donor lungs

Ischemia‐reperfusion (IR) injury after lung transplantation is still today an important complication in up to 25% of patients. The Organ Care System (OCS) Lung, an advanced normothermic ex vivo lung perfusion system, was found to be effective in reducing primary graft dysfunction compared to standar...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of transplantation 2020-12, Vol.20 (12), p.3639-3648
Hauptverfasser: Calabrese, Fiorella, Schiavon, Marco, Perissinotto, Egle, Lunardi, Francesca, Marulli, Giuseppe, Di Gregorio, Guido, Pezzuto, Federica, Edith Vuljan, Stefania, Forin, Edoardo, Wiegmann, Bettina, Jonigk, Danny, Warnecke, Gregor, Rea, Federico