An examination of methods for analysis of liquid metal corrosion
Methods of analyzing liquid metal penetration data are discussed and compared. Data on the corrosion of 2.25Cr--1Mo steel by liquid Li at 480 deg C are reanalyzed as an example, and a previously reported activation energy for a secondary penetration mechanism is corrected. 5 ref.--AA
Gespeichert in:
Veröffentlicht in: | J. Mater. Energy Syst.; (United States) 1986-12, Vol.8 (3), p.243-245 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Methods of analyzing liquid metal penetration data are discussed and compared. Data on the corrosion of 2.25Cr--1Mo steel by liquid Li at 480 deg C are reanalyzed as an example, and a previously reported activation energy for a secondary penetration mechanism is corrected. 5 ref.--AA |
---|---|
ISSN: | 0162-9719 2168-8133 |
DOI: | 10.1007/BF02833586 |