Recurrent laryngeal nerve management in transoral endoscopic thyroidectomy
•The incidence of temporary and permanent RLN dysfunction were 5.9% and 0.5%. A disrupted point (type 1 injury) could be identified in 7/12 nerves; 5 nerve injuries were classified as global.•3 lesions occurred at RLN laryngeal entry point, during nerve identification. Four type 1 injuries were at d...
Gespeichert in:
Veröffentlicht in: | Oral oncology 2020-09, Vol.108, p.104755-104755, Article 104755 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The incidence of temporary and permanent RLN dysfunction were 5.9% and 0.5%. A disrupted point (type 1 injury) could be identified in 7/12 nerves; 5 nerve injuries were classified as global.•3 lesions occurred at RLN laryngeal entry point, during nerve identification. Four type 1 injuries were at distal 1 cm of the RLN course, during earliest nerve dissection (1 injury).•Mechanisms of injury were thermal (58%) during energy-based device use.•Two traction injuries occurred during earliest nerve dissection.
The mechanism of recurrent laryngeal nerve (RLN) injury was investigated during a TransOral Endoscopic Thyroidectomy Vestibular Approach (TOETVA).
The function of 185 nerves at risk (NAR) was recorded with intermitted intraoperative neural monitoring (I-IONM). The RLN electromyography (EMG) was delineated during: (a) a pre-dissection vagal nerve stimulation; (b) a RLN stimulation at initial visualization; (c) at nerve dissection; and (d) at the final verification of the entire RLN route. The location, genesis, segmental or diffuse and the outcomes of RLN injuries were catalogued.
Twelve nerves (6.4%) lost the EMG signal and the incidences of temporary and permanent RLN dysfunction were 5.9% and 0.5%. A disrupted point (type 1 injury) could be identified in 7/12 nerves (58%). Five (42%) nerve injuries were classified as global (type 2). Of the seven type 1 injuries, 3 lesions occurred at the RLN laryngeal entry point during the nerve identification. Four type 1 injuries were at the distal 1 cm of the RLN course and during the early nerve dissection. No proximal (>2 cm) injuries occurred. The mechanisms of the injuries were thermal (58%) during the energy-based device use at the ligament of Berry dissection or at the dividing small branches of the inferior thyroid artery. Two (16%) traction injuries occurred during the early nerve dissection. In 2 cases we could not elucidate the mechanism of RLN injury (16%) and 1 injury (8%) was caused by the connective tissue constricting band of. The thermal RLN lesions had longer recovery times.
The RLN palsy occurs in TOETVA, even when combined with an endoscopic magnification, IONM, early nerve identification, cranial to caudal dissection and top-down view. The thermal RLN injury was the most frequent cause and all injuries occurred at the distal RLN course. |
---|---|
ISSN: | 1368-8375 1879-0593 |