Surgical Challenges of Heart Mate 3 Pump Implantation in Aneurysmally Changed Heart Ventricles
We presented surgical treatment of three patients indicated for implantation of a permanent mechanical circulatory support device and with the associated left ventricular aneurysms. In order to evade the left ventricular rupture, adverse thromboembolic events and provide safe implantation of the inf...
Gespeichert in:
Veröffentlicht in: | The Heart surgery forum 2020-06, Vol.23 (3), p.E393-E396 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | E396 |
---|---|
container_issue | 3 |
container_start_page | E393 |
container_title | The Heart surgery forum |
container_volume | 23 |
creator | Terzic, Dusko Nestorovic, Emilija Markovic, Dejan Kovacevic Kostic, Natasa Djordjevic, Aleksandar Karan, Radmila Cubrilo, Marko Stojiljkovic, Vladimir Milićević, Vladimir Cumic, Jelena Putnik, Svetozar |
description | We presented surgical treatment of three patients indicated for implantation of a permanent mechanical circulatory support device and with the associated left ventricular aneurysms. In order to evade the left ventricular rupture, adverse thromboembolic events and provide safe implantation of the inflow cannula, LVAD HM3 implantation together with the reconstruction of the left ventricular aneurysmal wall was performed in two patients. Regarding the third patient, LVAD implantation upon the reconstruction of the left ventricular wall was abandoned because there was no safe location for placement of the inflow cannula. |
doi_str_mv | 10.1532/hsf.2721 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2412210925</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2412210925</sourcerecordid><originalsourceid>FETCH-LOGICAL-c283t-e5c8d3ddf15756bc375325f0619c70ade557c6fcb849db5ffc58ba7cd82beb7c3</originalsourceid><addsrcrecordid>eNpFkMtOwzAQRS0EoqUg8QXISzYp8bi2k2VVAa0EAonHksixx21QHsVOFv17XFFgNbO452rmEHLJ0ikTHG42wU1BATsiYyYAEiklHMc9zbOEC8ZG5CyEzzQFCSBPyYiDgFmeqTH5eBn8ujK6pouNrmts1xho5-gSte_po-6Rcvo8NFu6ara1bnvdV11Lq5bOWxz8LjSR2u3hSNoD9o5t7ytTYzgnJ07XAS8Oc0Le7m5fF8vk4el-tZg_JAYy3icoTGa5tY4JJWRpuIpfCZdKlhuVaotCKCOdKbNZbkvhnBFZqZWxGZRYKsMn5Pqnd-u7rwFDXzRVMFjHi7EbQgEzBhB1gPiPGt-F4NEVW1812u8KlhZ7m0W0WextxujVoXUoG7R_wV99_BsujHCr</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2412210925</pqid></control><display><type>article</type><title>Surgical Challenges of Heart Mate 3 Pump Implantation in Aneurysmally Changed Heart Ventricles</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Terzic, Dusko ; Nestorovic, Emilija ; Markovic, Dejan ; Kovacevic Kostic, Natasa ; Djordjevic, Aleksandar ; Karan, Radmila ; Cubrilo, Marko ; Stojiljkovic, Vladimir ; Milićević, Vladimir ; Cumic, Jelena ; Putnik, Svetozar</creator><creatorcontrib>Terzic, Dusko ; Nestorovic, Emilija ; Markovic, Dejan ; Kovacevic Kostic, Natasa ; Djordjevic, Aleksandar ; Karan, Radmila ; Cubrilo, Marko ; Stojiljkovic, Vladimir ; Milićević, Vladimir ; Cumic, Jelena ; Putnik, Svetozar</creatorcontrib><description>We presented surgical treatment of three patients indicated for implantation of a permanent mechanical circulatory support device and with the associated left ventricular aneurysms. In order to evade the left ventricular rupture, adverse thromboembolic events and provide safe implantation of the inflow cannula, LVAD HM3 implantation together with the reconstruction of the left ventricular aneurysmal wall was performed in two patients. Regarding the third patient, LVAD implantation upon the reconstruction of the left ventricular wall was abandoned because there was no safe location for placement of the inflow cannula.</description><identifier>ISSN: 1098-3511</identifier><identifier>EISSN: 1522-6662</identifier><identifier>DOI: 10.1532/hsf.2721</identifier><identifier>PMID: 32524987</identifier><language>eng</language><publisher>United States</publisher><subject>Cardiac Surgical Procedures - methods ; Echocardiography ; Heart Aneurysm - diagnosis ; Heart Aneurysm - surgery ; Heart Ventricles - diagnostic imaging ; Heart Ventricles - surgery ; Heart-Assist Devices ; Humans ; Male ; Middle Aged ; Positron Emission Tomography Computed Tomography ; Prosthesis Design</subject><ispartof>The Heart surgery forum, 2020-06, Vol.23 (3), p.E393-E396</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c283t-e5c8d3ddf15756bc375325f0619c70ade557c6fcb849db5ffc58ba7cd82beb7c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32524987$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Terzic, Dusko</creatorcontrib><creatorcontrib>Nestorovic, Emilija</creatorcontrib><creatorcontrib>Markovic, Dejan</creatorcontrib><creatorcontrib>Kovacevic Kostic, Natasa</creatorcontrib><creatorcontrib>Djordjevic, Aleksandar</creatorcontrib><creatorcontrib>Karan, Radmila</creatorcontrib><creatorcontrib>Cubrilo, Marko</creatorcontrib><creatorcontrib>Stojiljkovic, Vladimir</creatorcontrib><creatorcontrib>Milićević, Vladimir</creatorcontrib><creatorcontrib>Cumic, Jelena</creatorcontrib><creatorcontrib>Putnik, Svetozar</creatorcontrib><title>Surgical Challenges of Heart Mate 3 Pump Implantation in Aneurysmally Changed Heart Ventricles</title><title>The Heart surgery forum</title><addtitle>Heart Surg Forum</addtitle><description>We presented surgical treatment of three patients indicated for implantation of a permanent mechanical circulatory support device and with the associated left ventricular aneurysms. In order to evade the left ventricular rupture, adverse thromboembolic events and provide safe implantation of the inflow cannula, LVAD HM3 implantation together with the reconstruction of the left ventricular aneurysmal wall was performed in two patients. Regarding the third patient, LVAD implantation upon the reconstruction of the left ventricular wall was abandoned because there was no safe location for placement of the inflow cannula.</description><subject>Cardiac Surgical Procedures - methods</subject><subject>Echocardiography</subject><subject>Heart Aneurysm - diagnosis</subject><subject>Heart Aneurysm - surgery</subject><subject>Heart Ventricles - diagnostic imaging</subject><subject>Heart Ventricles - surgery</subject><subject>Heart-Assist Devices</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Positron Emission Tomography Computed Tomography</subject><subject>Prosthesis Design</subject><issn>1098-3511</issn><issn>1522-6662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkMtOwzAQRS0EoqUg8QXISzYp8bi2k2VVAa0EAonHksixx21QHsVOFv17XFFgNbO452rmEHLJ0ikTHG42wU1BATsiYyYAEiklHMc9zbOEC8ZG5CyEzzQFCSBPyYiDgFmeqTH5eBn8ujK6pouNrmts1xho5-gSte_po-6Rcvo8NFu6ara1bnvdV11Lq5bOWxz8LjSR2u3hSNoD9o5t7ytTYzgnJ07XAS8Oc0Le7m5fF8vk4el-tZg_JAYy3icoTGa5tY4JJWRpuIpfCZdKlhuVaotCKCOdKbNZbkvhnBFZqZWxGZRYKsMn5Pqnd-u7rwFDXzRVMFjHi7EbQgEzBhB1gPiPGt-F4NEVW1812u8KlhZ7m0W0WextxujVoXUoG7R_wV99_BsujHCr</recordid><startdate>20200604</startdate><enddate>20200604</enddate><creator>Terzic, Dusko</creator><creator>Nestorovic, Emilija</creator><creator>Markovic, Dejan</creator><creator>Kovacevic Kostic, Natasa</creator><creator>Djordjevic, Aleksandar</creator><creator>Karan, Radmila</creator><creator>Cubrilo, Marko</creator><creator>Stojiljkovic, Vladimir</creator><creator>Milićević, Vladimir</creator><creator>Cumic, Jelena</creator><creator>Putnik, Svetozar</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20200604</creationdate><title>Surgical Challenges of Heart Mate 3 Pump Implantation in Aneurysmally Changed Heart Ventricles</title><author>Terzic, Dusko ; Nestorovic, Emilija ; Markovic, Dejan ; Kovacevic Kostic, Natasa ; Djordjevic, Aleksandar ; Karan, Radmila ; Cubrilo, Marko ; Stojiljkovic, Vladimir ; Milićević, Vladimir ; Cumic, Jelena ; Putnik, Svetozar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c283t-e5c8d3ddf15756bc375325f0619c70ade557c6fcb849db5ffc58ba7cd82beb7c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Cardiac Surgical Procedures - methods</topic><topic>Echocardiography</topic><topic>Heart Aneurysm - diagnosis</topic><topic>Heart Aneurysm - surgery</topic><topic>Heart Ventricles - diagnostic imaging</topic><topic>Heart Ventricles - surgery</topic><topic>Heart-Assist Devices</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Positron Emission Tomography Computed Tomography</topic><topic>Prosthesis Design</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Terzic, Dusko</creatorcontrib><creatorcontrib>Nestorovic, Emilija</creatorcontrib><creatorcontrib>Markovic, Dejan</creatorcontrib><creatorcontrib>Kovacevic Kostic, Natasa</creatorcontrib><creatorcontrib>Djordjevic, Aleksandar</creatorcontrib><creatorcontrib>Karan, Radmila</creatorcontrib><creatorcontrib>Cubrilo, Marko</creatorcontrib><creatorcontrib>Stojiljkovic, Vladimir</creatorcontrib><creatorcontrib>Milićević, Vladimir</creatorcontrib><creatorcontrib>Cumic, Jelena</creatorcontrib><creatorcontrib>Putnik, Svetozar</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Heart surgery forum</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Terzic, Dusko</au><au>Nestorovic, Emilija</au><au>Markovic, Dejan</au><au>Kovacevic Kostic, Natasa</au><au>Djordjevic, Aleksandar</au><au>Karan, Radmila</au><au>Cubrilo, Marko</au><au>Stojiljkovic, Vladimir</au><au>Milićević, Vladimir</au><au>Cumic, Jelena</au><au>Putnik, Svetozar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Surgical Challenges of Heart Mate 3 Pump Implantation in Aneurysmally Changed Heart Ventricles</atitle><jtitle>The Heart surgery forum</jtitle><addtitle>Heart Surg Forum</addtitle><date>2020-06-04</date><risdate>2020</risdate><volume>23</volume><issue>3</issue><spage>E393</spage><epage>E396</epage><pages>E393-E396</pages><issn>1098-3511</issn><eissn>1522-6662</eissn><abstract>We presented surgical treatment of three patients indicated for implantation of a permanent mechanical circulatory support device and with the associated left ventricular aneurysms. In order to evade the left ventricular rupture, adverse thromboembolic events and provide safe implantation of the inflow cannula, LVAD HM3 implantation together with the reconstruction of the left ventricular aneurysmal wall was performed in two patients. Regarding the third patient, LVAD implantation upon the reconstruction of the left ventricular wall was abandoned because there was no safe location for placement of the inflow cannula.</abstract><cop>United States</cop><pmid>32524987</pmid><doi>10.1532/hsf.2721</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1098-3511 |
ispartof | The Heart surgery forum, 2020-06, Vol.23 (3), p.E393-E396 |
issn | 1098-3511 1522-6662 |
language | eng |
recordid | cdi_proquest_miscellaneous_2412210925 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Cardiac Surgical Procedures - methods Echocardiography Heart Aneurysm - diagnosis Heart Aneurysm - surgery Heart Ventricles - diagnostic imaging Heart Ventricles - surgery Heart-Assist Devices Humans Male Middle Aged Positron Emission Tomography Computed Tomography Prosthesis Design |
title | Surgical Challenges of Heart Mate 3 Pump Implantation in Aneurysmally Changed Heart Ventricles |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T18%3A56%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Surgical%20Challenges%20of%20Heart%20Mate%203%20Pump%20Implantation%20in%20Aneurysmally%20Changed%20Heart%20Ventricles&rft.jtitle=The%20Heart%20surgery%20forum&rft.au=Terzic,%20Dusko&rft.date=2020-06-04&rft.volume=23&rft.issue=3&rft.spage=E393&rft.epage=E396&rft.pages=E393-E396&rft.issn=1098-3511&rft.eissn=1522-6662&rft_id=info:doi/10.1532/hsf.2721&rft_dat=%3Cproquest_cross%3E2412210925%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2412210925&rft_id=info:pmid/32524987&rfr_iscdi=true |