Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators

BACKGROUNDIn spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life. OBJECTIVETo carry out the translation, cross-cultural adapt...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arquivos brasileiros de cardiologia 2020-05, Vol.114 (5), p.764-772
Hauptverfasser: Silva, Katia Regina, Costa, Roberto, Melo, Giovanna Regina Garcia de Oliveira, Rebustini, Flávio, Benedetto, Marcos Sidney, Nagumo, Marcia Mitie, Sears, Samuel F
Format: Artikel
Sprache:eng ; por
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 772
container_issue 5
container_start_page 764
container_title Arquivos brasileiros de cardiologia
container_volume 114
creator Silva, Katia Regina
Costa, Roberto
Melo, Giovanna Regina Garcia de Oliveira
Rebustini, Flávio
Benedetto, Marcos Sidney
Nagumo, Marcia Mitie
Sears, Samuel F
description BACKGROUNDIn spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life. OBJECTIVETo carry out the translation, cross-cultural adaptation and validation of the Florida Shock Anxiety Scale (FSAS) scale into Brazilian Portuguese. METHODSIn this psychometric study, construct validity was performed by exploratory (EFA) and confirmatory (CFA) factor analyses, and by item response theory (IRT). The adjustment indexes of the CFA were: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) and RMSR (Root Mean Square of Residuals). Reliability was evaluated through Cronbach's Alpha, McDonald's Omega and Greatest Lower Bound (GLB). The analyses were carried out with the programs SPSS 23 and Factor 10.8.01. A 5 percent significance level was used. RESULTSThe final Portuguese version of the FSAS was administered to 151 ICD patients, with a mean age of 55.7 ± 14.1 years, and predominantly male. The parallel analysis indicated that the FSAS is unidimensional, with an explained variance of 64.4%. The correlations ranged from 0.31 to 0.77, factor loadings from 0.67 to 0.86, and communalities from 0.46 to 0.74. The adjustment indexes of the CFA were above the quality threshold. Satisfactory reliability evidence was provided by the FSAS. CONCLUSIONSThe FSAS-Br showed consistent validity and reliability evidence. Therefore, it can be used in ICD patients in Brazil. (Arq Bras Cardiol. 2020; 114(5):764-772).
doi_str_mv 10.36660/abc.20190255
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_2409191435</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2409191435</sourcerecordid><originalsourceid>FETCH-LOGICAL-p188t-1bc42a85e4f48efcb43457187733e822d114410fc55e559d3169056045e54b273</originalsourceid><addsrcrecordid>eNo1j01LAzEYhIMgWKtH7zl62ZrP3eyx1rYWCgrVXks2-4ZG001N0vrxB_zbLqinYXiYYQahK0pGvCxLcqMbM2KE1oRJeYIGtKxUIWhFztB5Si-EMFZxOUDfa-1d6_Innh5dC50BHCzOW8C3UX8573SH1xCTC90_mPkQXavxahvMKx53Hw76-MpoD9iGiB91dtDlhN9d3uLFbu91l3XT04mOrQtHiBkivgPrmui81znEdIFOrfYJLv90iJ5n06fJfbF8mC8m42Wxp0rlgjZGMK0kCCsUWNMILmRFVVVxDoqxllIhKLFGSpCybjktayJLInormv7yEF3_9u5jeDtAypudSwb6FR2EQ9owQWpaU8El_wHvY2Qv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2409191435</pqid></control><display><type>article</type><title>Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators</title><source>DOAJ Directory of Open Access Journals</source><source>PubMed Central Open Access</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Silva, Katia Regina ; Costa, Roberto ; Melo, Giovanna Regina Garcia de Oliveira ; Rebustini, Flávio ; Benedetto, Marcos Sidney ; Nagumo, Marcia Mitie ; Sears, Samuel F</creator><creatorcontrib>Silva, Katia Regina ; Costa, Roberto ; Melo, Giovanna Regina Garcia de Oliveira ; Rebustini, Flávio ; Benedetto, Marcos Sidney ; Nagumo, Marcia Mitie ; Sears, Samuel F</creatorcontrib><description>BACKGROUNDIn spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life. OBJECTIVETo carry out the translation, cross-cultural adaptation and validation of the Florida Shock Anxiety Scale (FSAS) scale into Brazilian Portuguese. METHODSIn this psychometric study, construct validity was performed by exploratory (EFA) and confirmatory (CFA) factor analyses, and by item response theory (IRT). The adjustment indexes of the CFA were: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) and RMSR (Root Mean Square of Residuals). Reliability was evaluated through Cronbach's Alpha, McDonald's Omega and Greatest Lower Bound (GLB). The analyses were carried out with the programs SPSS 23 and Factor 10.8.01. A 5 percent significance level was used. RESULTSThe final Portuguese version of the FSAS was administered to 151 ICD patients, with a mean age of 55.7 ± 14.1 years, and predominantly male. The parallel analysis indicated that the FSAS is unidimensional, with an explained variance of 64.4%. The correlations ranged from 0.31 to 0.77, factor loadings from 0.67 to 0.86, and communalities from 0.46 to 0.74. The adjustment indexes of the CFA were above the quality threshold. Satisfactory reliability evidence was provided by the FSAS. CONCLUSIONSThe FSAS-Br showed consistent validity and reliability evidence. Therefore, it can be used in ICD patients in Brazil. (Arq Bras Cardiol. 2020; 114(5):764-772).</description><identifier>EISSN: 1678-4170</identifier><identifier>DOI: 10.36660/abc.20190255</identifier><language>eng ; por</language><ispartof>Arquivos brasileiros de cardiologia, 2020-05, Vol.114 (5), p.764-772</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27924,27925</link.rule.ids></links><search><creatorcontrib>Silva, Katia Regina</creatorcontrib><creatorcontrib>Costa, Roberto</creatorcontrib><creatorcontrib>Melo, Giovanna Regina Garcia de Oliveira</creatorcontrib><creatorcontrib>Rebustini, Flávio</creatorcontrib><creatorcontrib>Benedetto, Marcos Sidney</creatorcontrib><creatorcontrib>Nagumo, Marcia Mitie</creatorcontrib><creatorcontrib>Sears, Samuel F</creatorcontrib><title>Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators</title><title>Arquivos brasileiros de cardiologia</title><description>BACKGROUNDIn spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life. OBJECTIVETo carry out the translation, cross-cultural adaptation and validation of the Florida Shock Anxiety Scale (FSAS) scale into Brazilian Portuguese. METHODSIn this psychometric study, construct validity was performed by exploratory (EFA) and confirmatory (CFA) factor analyses, and by item response theory (IRT). The adjustment indexes of the CFA were: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) and RMSR (Root Mean Square of Residuals). Reliability was evaluated through Cronbach's Alpha, McDonald's Omega and Greatest Lower Bound (GLB). The analyses were carried out with the programs SPSS 23 and Factor 10.8.01. A 5 percent significance level was used. RESULTSThe final Portuguese version of the FSAS was administered to 151 ICD patients, with a mean age of 55.7 ± 14.1 years, and predominantly male. The parallel analysis indicated that the FSAS is unidimensional, with an explained variance of 64.4%. The correlations ranged from 0.31 to 0.77, factor loadings from 0.67 to 0.86, and communalities from 0.46 to 0.74. The adjustment indexes of the CFA were above the quality threshold. Satisfactory reliability evidence was provided by the FSAS. CONCLUSIONSThe FSAS-Br showed consistent validity and reliability evidence. Therefore, it can be used in ICD patients in Brazil. (Arq Bras Cardiol. 2020; 114(5):764-772).</description><issn>1678-4170</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNo1j01LAzEYhIMgWKtH7zl62ZrP3eyx1rYWCgrVXks2-4ZG001N0vrxB_zbLqinYXiYYQahK0pGvCxLcqMbM2KE1oRJeYIGtKxUIWhFztB5Si-EMFZxOUDfa-1d6_Innh5dC50BHCzOW8C3UX8573SH1xCTC90_mPkQXavxahvMKx53Hw76-MpoD9iGiB91dtDlhN9d3uLFbu91l3XT04mOrQtHiBkivgPrmui81znEdIFOrfYJLv90iJ5n06fJfbF8mC8m42Wxp0rlgjZGMK0kCCsUWNMILmRFVVVxDoqxllIhKLFGSpCybjktayJLInormv7yEF3_9u5jeDtAypudSwb6FR2EQ9owQWpaU8El_wHvY2Qv</recordid><startdate>20200501</startdate><enddate>20200501</enddate><creator>Silva, Katia Regina</creator><creator>Costa, Roberto</creator><creator>Melo, Giovanna Regina Garcia de Oliveira</creator><creator>Rebustini, Flávio</creator><creator>Benedetto, Marcos Sidney</creator><creator>Nagumo, Marcia Mitie</creator><creator>Sears, Samuel F</creator><scope>7X8</scope></search><sort><creationdate>20200501</creationdate><title>Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators</title><author>Silva, Katia Regina ; Costa, Roberto ; Melo, Giovanna Regina Garcia de Oliveira ; Rebustini, Flávio ; Benedetto, Marcos Sidney ; Nagumo, Marcia Mitie ; Sears, Samuel F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p188t-1bc42a85e4f48efcb43457187733e822d114410fc55e559d3169056045e54b273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; por</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Silva, Katia Regina</creatorcontrib><creatorcontrib>Costa, Roberto</creatorcontrib><creatorcontrib>Melo, Giovanna Regina Garcia de Oliveira</creatorcontrib><creatorcontrib>Rebustini, Flávio</creatorcontrib><creatorcontrib>Benedetto, Marcos Sidney</creatorcontrib><creatorcontrib>Nagumo, Marcia Mitie</creatorcontrib><creatorcontrib>Sears, Samuel F</creatorcontrib><collection>MEDLINE - Academic</collection><jtitle>Arquivos brasileiros de cardiologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Silva, Katia Regina</au><au>Costa, Roberto</au><au>Melo, Giovanna Regina Garcia de Oliveira</au><au>Rebustini, Flávio</au><au>Benedetto, Marcos Sidney</au><au>Nagumo, Marcia Mitie</au><au>Sears, Samuel F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators</atitle><jtitle>Arquivos brasileiros de cardiologia</jtitle><date>2020-05-01</date><risdate>2020</risdate><volume>114</volume><issue>5</issue><spage>764</spage><epage>772</epage><pages>764-772</pages><eissn>1678-4170</eissn><abstract>BACKGROUNDIn spite of proven effectiveness of implantable cardioverter defibrillators (ICDs), shock therapy delivered by the device may result in increased levels of anxiety and depression, leading to deleterious effects on quality of life. OBJECTIVETo carry out the translation, cross-cultural adaptation and validation of the Florida Shock Anxiety Scale (FSAS) scale into Brazilian Portuguese. METHODSIn this psychometric study, construct validity was performed by exploratory (EFA) and confirmatory (CFA) factor analyses, and by item response theory (IRT). The adjustment indexes of the CFA were: Robust Mean-Scaled Chi Square/df NNFI, CFI (Comparative Fit Index), GFI (Goodness Fit Index), AGFI (Adjusted Goodness Fit Index), RMSEA (Root Mean Square Error of Approximation) and RMSR (Root Mean Square of Residuals). Reliability was evaluated through Cronbach's Alpha, McDonald's Omega and Greatest Lower Bound (GLB). The analyses were carried out with the programs SPSS 23 and Factor 10.8.01. A 5 percent significance level was used. RESULTSThe final Portuguese version of the FSAS was administered to 151 ICD patients, with a mean age of 55.7 ± 14.1 years, and predominantly male. The parallel analysis indicated that the FSAS is unidimensional, with an explained variance of 64.4%. The correlations ranged from 0.31 to 0.77, factor loadings from 0.67 to 0.86, and communalities from 0.46 to 0.74. The adjustment indexes of the CFA were above the quality threshold. Satisfactory reliability evidence was provided by the FSAS. CONCLUSIONSThe FSAS-Br showed consistent validity and reliability evidence. Therefore, it can be used in ICD patients in Brazil. (Arq Bras Cardiol. 2020; 114(5):764-772).</abstract><doi>10.36660/abc.20190255</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 1678-4170
ispartof Arquivos brasileiros de cardiologia, 2020-05, Vol.114 (5), p.764-772
issn 1678-4170
language eng ; por
recordid cdi_proquest_miscellaneous_2409191435
source DOAJ Directory of Open Access Journals; PubMed Central Open Access; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
title Validity Evidence of the Brazilian Version of the Florida Shock Anxiety Scale for Patients with Implantable Cardioverter Defibrillators
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T12%3A47%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Validity%20Evidence%20of%20the%20Brazilian%20Version%20of%20the%20Florida%20Shock%20Anxiety%20Scale%20for%20Patients%20with%20Implantable%20Cardioverter%20Defibrillators&rft.jtitle=Arquivos%20brasileiros%20de%20cardiologia&rft.au=Silva,%20Katia%20Regina&rft.date=2020-05-01&rft.volume=114&rft.issue=5&rft.spage=764&rft.epage=772&rft.pages=764-772&rft.eissn=1678-4170&rft_id=info:doi/10.36660/abc.20190255&rft_dat=%3Cproquest%3E2409191435%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2409191435&rft_id=info:pmid/&rfr_iscdi=true