2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry

Purpose To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T1 mapping at 7 T in mice and for MR thermometry. Methods The 2D‐MP2RAGE sequence was performed with the following parameters: TI1‐TI2‐MP2RAGETR = 1000‐3000‐9000 ms. The multiple dead times within the sequence were used...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in medicine 2020-09, Vol.84 (3), p.1430-1440
Hauptverfasser: Faller, Thibaut L., Trotier, Aurélien J., Rousseau, Alice F., Franconi, Jean‐Michel, Miraux, Sylvain, Ribot, Emeline J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1440
container_issue 3
container_start_page 1430
container_title Magnetic resonance in medicine
container_volume 84
creator Faller, Thibaut L.
Trotier, Aurélien J.
Rousseau, Alice F.
Franconi, Jean‐Michel
Miraux, Sylvain
Ribot, Emeline J.
description Purpose To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T1 mapping at 7 T in mice and for MR thermometry. Methods The 2D‐MP2RAGE sequence was performed with the following parameters: TI1‐TI2‐MP2RAGETR = 1000‐3000‐9000 ms. The multiple dead times within the sequence were used for interleaved multislice acquisition, enabling one to acquire six slices in 9 seconds. The excitation pulse shape, inversion selectivity, and interslice gap were optimized. In vitro comparison with the inversion‐recovery sequence was performed. The T1 variations with temperature were measured on tubes with T1 ranging from 800 ms to 2000 ms. The sequence was used to acquire T1 maps continuously during 30 minutes on the brain and abdomen of healthy mice. Results A three‐lobe cardinal sine excitation pulse, combined with an inversion slice thickness and an interslice gap of respectively 150% and 50% of the imaging slice thickness, led to a SD and bias of the T1 measurements below 1% and 2%, respectively. A linear dependence of T1 with temperature was measured between 10°C and 60°C. In vivo, less than 1% variation was measured between successive T1 maps in the mouse brain. In the abdomen, no obvious in‐plane motion artifacts were observed but respiratory motion in the slice dimension led to 6% T1 underestimation. Conclusion The multislice MP2RAGE sequence could be used for fast whole‐body T1 mapping and MR thermometry. Its reconstruction method would enable on‐the‐fly reconstruction.
doi_str_mv 10.1002/mrm.28220
format Article
fullrecord <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_proquest_miscellaneous_2408539705</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2408539705</sourcerecordid><originalsourceid>FETCH-LOGICAL-p2910-2cf29acc64b9ee25a06bf72716126487614fd6f62b844bdcb11fc501c7ad21f43</originalsourceid><addsrcrecordid>eNpdkMFOwzAQRC0EEqVw4A8sceGS1t44ccytKqUgNQJV5Ww5qV1SxUmIHaH-PW7LidOuVm9WM4PQPSUTSghMbW8nkAGQCzSiCUAEiWCXaEQ4I1FMBbtGN87tCSFCcDZCe3jGdqh95eqq1Dj_gPVsucBOfw-6CQfT9tgo5_GGYqu6rmp2WHnM8eYJz7ouiJSv2gb7Ftt2cBpXVu1OULPF-Rr7L93b1mrfH27RlVG103d_c4w-Xxab-Wu0el--zWerqANBSQSlAaHKMmWF0BoSRdLCcOA0pZCyjKeUmW1qUigyxoptWVBqyoTQkqstUMPiMXo8_-36NqRwXtrKlbquVaODRQmMZEksOEkC-vAP3bdD3wR3R4pnjNI0C9T0TP1UtT7Irg8Z-4OkRB4rl6Fyeapc5uv8tMS_t4JzzA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2407841168</pqid></control><display><type>article</type><title>2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Faller, Thibaut L. ; Trotier, Aurélien J. ; Rousseau, Alice F. ; Franconi, Jean‐Michel ; Miraux, Sylvain ; Ribot, Emeline J.</creator><creatorcontrib>Faller, Thibaut L. ; Trotier, Aurélien J. ; Rousseau, Alice F. ; Franconi, Jean‐Michel ; Miraux, Sylvain ; Ribot, Emeline J.</creatorcontrib><description>Purpose To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T1 mapping at 7 T in mice and for MR thermometry. Methods The 2D‐MP2RAGE sequence was performed with the following parameters: TI1‐TI2‐MP2RAGETR = 1000‐3000‐9000 ms. The multiple dead times within the sequence were used for interleaved multislice acquisition, enabling one to acquire six slices in 9 seconds. The excitation pulse shape, inversion selectivity, and interslice gap were optimized. In vitro comparison with the inversion‐recovery sequence was performed. The T1 variations with temperature were measured on tubes with T1 ranging from 800 ms to 2000 ms. The sequence was used to acquire T1 maps continuously during 30 minutes on the brain and abdomen of healthy mice. Results A three‐lobe cardinal sine excitation pulse, combined with an inversion slice thickness and an interslice gap of respectively 150% and 50% of the imaging slice thickness, led to a SD and bias of the T1 measurements below 1% and 2%, respectively. A linear dependence of T1 with temperature was measured between 10°C and 60°C. In vivo, less than 1% variation was measured between successive T1 maps in the mouse brain. In the abdomen, no obvious in‐plane motion artifacts were observed but respiratory motion in the slice dimension led to 6% T1 underestimation. Conclusion The multislice MP2RAGE sequence could be used for fast whole‐body T1 mapping and MR thermometry. Its reconstruction method would enable on‐the‐fly reconstruction.</description><identifier>ISSN: 0740-3194</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.28220</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc</publisher><subject>2D multislice ; 7 T ; Abdomen ; Brain ; Brain mapping ; Excitation ; Image reconstruction ; Inversion ; Magnetic resonance imaging ; Mapping ; mouse ; MP2RAGE ; Neuroimaging ; Pulse shape ; Selectivity ; T1 mapping ; Temperature dependence ; Thermal imaging ; Thermometry ; Thickness ; Tubes</subject><ispartof>Magnetic resonance in medicine, 2020-09, Vol.84 (3), p.1430-1440</ispartof><rights>2020 International Society for Magnetic Resonance in Medicine</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-3063-1263</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.28220$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.28220$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids></links><search><creatorcontrib>Faller, Thibaut L.</creatorcontrib><creatorcontrib>Trotier, Aurélien J.</creatorcontrib><creatorcontrib>Rousseau, Alice F.</creatorcontrib><creatorcontrib>Franconi, Jean‐Michel</creatorcontrib><creatorcontrib>Miraux, Sylvain</creatorcontrib><creatorcontrib>Ribot, Emeline J.</creatorcontrib><title>2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry</title><title>Magnetic resonance in medicine</title><description>Purpose To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T1 mapping at 7 T in mice and for MR thermometry. Methods The 2D‐MP2RAGE sequence was performed with the following parameters: TI1‐TI2‐MP2RAGETR = 1000‐3000‐9000 ms. The multiple dead times within the sequence were used for interleaved multislice acquisition, enabling one to acquire six slices in 9 seconds. The excitation pulse shape, inversion selectivity, and interslice gap were optimized. In vitro comparison with the inversion‐recovery sequence was performed. The T1 variations with temperature were measured on tubes with T1 ranging from 800 ms to 2000 ms. The sequence was used to acquire T1 maps continuously during 30 minutes on the brain and abdomen of healthy mice. Results A three‐lobe cardinal sine excitation pulse, combined with an inversion slice thickness and an interslice gap of respectively 150% and 50% of the imaging slice thickness, led to a SD and bias of the T1 measurements below 1% and 2%, respectively. A linear dependence of T1 with temperature was measured between 10°C and 60°C. In vivo, less than 1% variation was measured between successive T1 maps in the mouse brain. In the abdomen, no obvious in‐plane motion artifacts were observed but respiratory motion in the slice dimension led to 6% T1 underestimation. Conclusion The multislice MP2RAGE sequence could be used for fast whole‐body T1 mapping and MR thermometry. Its reconstruction method would enable on‐the‐fly reconstruction.</description><subject>2D multislice</subject><subject>7 T</subject><subject>Abdomen</subject><subject>Brain</subject><subject>Brain mapping</subject><subject>Excitation</subject><subject>Image reconstruction</subject><subject>Inversion</subject><subject>Magnetic resonance imaging</subject><subject>Mapping</subject><subject>mouse</subject><subject>MP2RAGE</subject><subject>Neuroimaging</subject><subject>Pulse shape</subject><subject>Selectivity</subject><subject>T1 mapping</subject><subject>Temperature dependence</subject><subject>Thermal imaging</subject><subject>Thermometry</subject><subject>Thickness</subject><subject>Tubes</subject><issn>0740-3194</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpdkMFOwzAQRC0EEqVw4A8sceGS1t44ccytKqUgNQJV5Ww5qV1SxUmIHaH-PW7LidOuVm9WM4PQPSUTSghMbW8nkAGQCzSiCUAEiWCXaEQ4I1FMBbtGN87tCSFCcDZCe3jGdqh95eqq1Dj_gPVsucBOfw-6CQfT9tgo5_GGYqu6rmp2WHnM8eYJz7ouiJSv2gb7Ftt2cBpXVu1OULPF-Rr7L93b1mrfH27RlVG103d_c4w-Xxab-Wu0el--zWerqANBSQSlAaHKMmWF0BoSRdLCcOA0pZCyjKeUmW1qUigyxoptWVBqyoTQkqstUMPiMXo8_-36NqRwXtrKlbquVaODRQmMZEksOEkC-vAP3bdD3wR3R4pnjNI0C9T0TP1UtT7Irg8Z-4OkRB4rl6Fyeapc5uv8tMS_t4JzzA</recordid><startdate>202009</startdate><enddate>202009</enddate><creator>Faller, Thibaut L.</creator><creator>Trotier, Aurélien J.</creator><creator>Rousseau, Alice F.</creator><creator>Franconi, Jean‐Michel</creator><creator>Miraux, Sylvain</creator><creator>Ribot, Emeline J.</creator><general>Wiley Subscription Services, Inc</general><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-3063-1263</orcidid></search><sort><creationdate>202009</creationdate><title>2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry</title><author>Faller, Thibaut L. ; Trotier, Aurélien J. ; Rousseau, Alice F. ; Franconi, Jean‐Michel ; Miraux, Sylvain ; Ribot, Emeline J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p2910-2cf29acc64b9ee25a06bf72716126487614fd6f62b844bdcb11fc501c7ad21f43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>2D multislice</topic><topic>7 T</topic><topic>Abdomen</topic><topic>Brain</topic><topic>Brain mapping</topic><topic>Excitation</topic><topic>Image reconstruction</topic><topic>Inversion</topic><topic>Magnetic resonance imaging</topic><topic>Mapping</topic><topic>mouse</topic><topic>MP2RAGE</topic><topic>Neuroimaging</topic><topic>Pulse shape</topic><topic>Selectivity</topic><topic>T1 mapping</topic><topic>Temperature dependence</topic><topic>Thermal imaging</topic><topic>Thermometry</topic><topic>Thickness</topic><topic>Tubes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Faller, Thibaut L.</creatorcontrib><creatorcontrib>Trotier, Aurélien J.</creatorcontrib><creatorcontrib>Rousseau, Alice F.</creatorcontrib><creatorcontrib>Franconi, Jean‐Michel</creatorcontrib><creatorcontrib>Miraux, Sylvain</creatorcontrib><creatorcontrib>Ribot, Emeline J.</creatorcontrib><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Faller, Thibaut L.</au><au>Trotier, Aurélien J.</au><au>Rousseau, Alice F.</au><au>Franconi, Jean‐Michel</au><au>Miraux, Sylvain</au><au>Ribot, Emeline J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry</atitle><jtitle>Magnetic resonance in medicine</jtitle><date>2020-09</date><risdate>2020</risdate><volume>84</volume><issue>3</issue><spage>1430</spage><epage>1440</epage><pages>1430-1440</pages><issn>0740-3194</issn><eissn>1522-2594</eissn><abstract>Purpose To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T1 mapping at 7 T in mice and for MR thermometry. Methods The 2D‐MP2RAGE sequence was performed with the following parameters: TI1‐TI2‐MP2RAGETR = 1000‐3000‐9000 ms. The multiple dead times within the sequence were used for interleaved multislice acquisition, enabling one to acquire six slices in 9 seconds. The excitation pulse shape, inversion selectivity, and interslice gap were optimized. In vitro comparison with the inversion‐recovery sequence was performed. The T1 variations with temperature were measured on tubes with T1 ranging from 800 ms to 2000 ms. The sequence was used to acquire T1 maps continuously during 30 minutes on the brain and abdomen of healthy mice. Results A three‐lobe cardinal sine excitation pulse, combined with an inversion slice thickness and an interslice gap of respectively 150% and 50% of the imaging slice thickness, led to a SD and bias of the T1 measurements below 1% and 2%, respectively. A linear dependence of T1 with temperature was measured between 10°C and 60°C. In vivo, less than 1% variation was measured between successive T1 maps in the mouse brain. In the abdomen, no obvious in‐plane motion artifacts were observed but respiratory motion in the slice dimension led to 6% T1 underestimation. Conclusion The multislice MP2RAGE sequence could be used for fast whole‐body T1 mapping and MR thermometry. Its reconstruction method would enable on‐the‐fly reconstruction.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1002/mrm.28220</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-3063-1263</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 2020-09, Vol.84 (3), p.1430-1440
issn 0740-3194
1522-2594
language eng
recordid cdi_proquest_miscellaneous_2408539705
source Wiley Online Library Journals Frontfile Complete
subjects 2D multislice
7 T
Abdomen
Brain
Brain mapping
Excitation
Image reconstruction
Inversion
Magnetic resonance imaging
Mapping
mouse
MP2RAGE
Neuroimaging
Pulse shape
Selectivity
T1 mapping
Temperature dependence
Thermal imaging
Thermometry
Thickness
Tubes
title 2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T02%3A19%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=2D%20multislice%20MP2RAGE%20sequence%20for%20fast%20T1%20mapping%20at%207%20T:%20Application%20to%20mouse%20imaging%20and%20MR%20thermometry&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Faller,%20Thibaut%20L.&rft.date=2020-09&rft.volume=84&rft.issue=3&rft.spage=1430&rft.epage=1440&rft.pages=1430-1440&rft.issn=0740-3194&rft.eissn=1522-2594&rft_id=info:doi/10.1002/mrm.28220&rft_dat=%3Cproquest_wiley%3E2408539705%3C/proquest_wiley%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2407841168&rft_id=info:pmid/&rfr_iscdi=true