Effect of different grinding protocols on surface characteristics and fatigue behavior of yttria-stabilized zirconia polycrystalline: An in vitro study
Zirconia frameworks milled by computer-aided design and computer-aided manufacturing (CAD-CAM) often require clinical adjustments. In addition, zirconia prefabricated abutments can also require customization to achieve an adequate emergence profile. However, the influence of grinding adjustment on t...
Gespeichert in:
Veröffentlicht in: | The Journal of prosthetic dentistry 2020-10, Vol.124 (4), p.486.e1-486.e8 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Zirconia frameworks milled by computer-aided design and computer-aided manufacturing (CAD-CAM) often require clinical adjustments. In addition, zirconia prefabricated abutments can also require customization to achieve an adequate emergence profile. However, the influence of grinding adjustment on the surface characteristics and mechanical behavior of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and the best grinding protocol is unclear.
The purpose of this in vitro study was to evaluate the effect of different grinding protocols on the surface characteristics, phase transformation, and mechanical behavior of Y-TZP for frameworks and implant abutments.
Bar-shaped specimens were fabricated according to ISO 6872-2016 and divided into 3 groups: GC (control, untreated), GA (grinding and finishing with medium and fine diamond rotary instruments using high-speed handpiece under constant water cooling), and GB (grinding and finishing with coarse and medium diamond rotary instruments, respectively, using slow-speed handpiece without water cooling). After specimen grinding, the topography and surface roughness were evaluated by using a laser confocal microscope, the Young modulus was measured by the impulse excitation technique, and crystallographic phase transformation was analyzed by X-ray diffraction. Specimens were then submitted to step-stress accelerated life testing (n=18). The surface roughness and Young modulus results were analyzed by 1-way ANOVA and the Tukey honestly significant difference test (α=.05). The data of step-stress accelerated life testing were analyzed by the survival probability considering the number of cycles and force until fracture.
Statistically significant differences were found among groups considering surface roughness (GA>GB>GC) (PGA=GC) (P=.003). X-ray diffraction showed that grinding leads to phase transformation, GC showed only tetragonal phase, while GA and GB showed tetragonal and monoclinic phases. No statistically significant difference (P |
---|---|