Community hospital stethoscope cleaning practices and contamination rates
•Stethoscope disinfection efficiency.•Hospital acquired infections caused by stethoscope.•Stethoscope cleaning practices.•Stethoscope contamination with bacteria.•Guidelines for stethoscope disinfection. In the United States, nosocomial infections are estimated to cause 72,000 annual deaths. The ste...
Gespeichert in:
Veröffentlicht in: | American journal of infection control 2020-11, Vol.48 (11), p.1365-1369 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1369 |
---|---|
container_issue | 11 |
container_start_page | 1365 |
container_title | American journal of infection control |
container_volume | 48 |
creator | Alali, Sukaina Ali Shrestha, Ekta Kansakar, Aswin Ratna Parekh, Amishi Dadkhah, Shahriar Peacock, W. Frank |
description | •Stethoscope disinfection efficiency.•Hospital acquired infections caused by stethoscope.•Stethoscope cleaning practices.•Stethoscope contamination with bacteria.•Guidelines for stethoscope disinfection.
In the United States, nosocomial infections are estimated to cause 72,000 annual deaths. The stethoscope, commonly used, is rarely reported as a potential vector. Our study aims to describe stethoscope contamination and the effect of self-reported cleaning practices among health care providers in a community hospital setting.
Stethoscopes were collected at random times from health care providers and cultured per standard techniques. Providers answered a structured questionnaire related to their cleaning practices. Differences in bacterial growth rates and the impact of profession, cleaning frequency, and prior sanitization were evaluated.
Of 104 cultured stethoscopes, 44% were from residents and medical students, from which 76% had bacterial growth, and 56% were from attendings, nurses, and respiratory therapists who had 91.4% growth (95% = confidence interval 0.62-0.86 and 0.81-0.96, respectively). Overall, 86.5% of providers claimed disinfection frequency compliant with Center for Disease Control and Prevention guidelines but there were no statistical differences between self-reported cleaning frequency or methods, and the presence of bacteria.
Most stethoscopes are contaminated with bacteria, the presence of which was not affected by reported cleaning strategies. |
doi_str_mv | 10.1016/j.ajic.2020.04.019 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2398159105</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0196655320302662</els_id><sourcerecordid>2398159105</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-e1f506e7b3648f2334b66d58c7b1a3eeab14b3ef816a00bbbcc7b35f144f4c4e3</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhi0EoqXwBxhQRpYEO_5II7Ggio9KlVhgtmznAo4SO9guUv89qVoYmU5399wr3YPQNcEFwUTcdYXqrClKXOICswKT-gTNCS-rnJa1OEXzaSJywTmdoYsYO4xxTQU_RzNaUoErVs3ReuWHYets2mWfPo42qT6LCdLUGD9CZnpQzrqPbAzKJGsgZso1mfEuqcE6lax3WVAJ4iU6a1Uf4epYF-j96fFt9ZJvXp_Xq4dNbigXKQfSciyg0lSwZVtSyrQQDV-aShNFAZQmTFNol0QojLXWZtpQ3hLGWmYY0AW6PeSOwX9tISY52Gig75UDv42ypPWS8JpgPqHlATXBxxiglWOwgwo7SbDcK5Sd3CuUe4USMzkJm45ujvlbPUDzd_LrbALuDwBMX35bCDIaC85AYwOYJBtv_8v_ATLcg6M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2398159105</pqid></control><display><type>article</type><title>Community hospital stethoscope cleaning practices and contamination rates</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Alali, Sukaina Ali ; Shrestha, Ekta ; Kansakar, Aswin Ratna ; Parekh, Amishi ; Dadkhah, Shahriar ; Peacock, W. Frank</creator><creatorcontrib>Alali, Sukaina Ali ; Shrestha, Ekta ; Kansakar, Aswin Ratna ; Parekh, Amishi ; Dadkhah, Shahriar ; Peacock, W. Frank</creatorcontrib><description>•Stethoscope disinfection efficiency.•Hospital acquired infections caused by stethoscope.•Stethoscope cleaning practices.•Stethoscope contamination with bacteria.•Guidelines for stethoscope disinfection.
In the United States, nosocomial infections are estimated to cause 72,000 annual deaths. The stethoscope, commonly used, is rarely reported as a potential vector. Our study aims to describe stethoscope contamination and the effect of self-reported cleaning practices among health care providers in a community hospital setting.
Stethoscopes were collected at random times from health care providers and cultured per standard techniques. Providers answered a structured questionnaire related to their cleaning practices. Differences in bacterial growth rates and the impact of profession, cleaning frequency, and prior sanitization were evaluated.
Of 104 cultured stethoscopes, 44% were from residents and medical students, from which 76% had bacterial growth, and 56% were from attendings, nurses, and respiratory therapists who had 91.4% growth (95% = confidence interval 0.62-0.86 and 0.81-0.96, respectively). Overall, 86.5% of providers claimed disinfection frequency compliant with Center for Disease Control and Prevention guidelines but there were no statistical differences between self-reported cleaning frequency or methods, and the presence of bacteria.
Most stethoscopes are contaminated with bacteria, the presence of which was not affected by reported cleaning strategies.</description><identifier>ISSN: 0196-6553</identifier><identifier>EISSN: 1527-3296</identifier><identifier>DOI: 10.1016/j.ajic.2020.04.019</identifier><identifier>PMID: 32360747</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Cleaning strategies ; Disinfection ; Nosocomial infection ; Sanitization methods ; Stethoscope contamination</subject><ispartof>American journal of infection control, 2020-11, Vol.48 (11), p.1365-1369</ispartof><rights>2020 Association for Professionals in Infection Control and Epidemiology, Inc.</rights><rights>Copyright © 2020. Published by Elsevier Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-e1f506e7b3648f2334b66d58c7b1a3eeab14b3ef816a00bbbcc7b35f144f4c4e3</citedby><cites>FETCH-LOGICAL-c356t-e1f506e7b3648f2334b66d58c7b1a3eeab14b3ef816a00bbbcc7b35f144f4c4e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0196655320302662$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32360747$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Alali, Sukaina Ali</creatorcontrib><creatorcontrib>Shrestha, Ekta</creatorcontrib><creatorcontrib>Kansakar, Aswin Ratna</creatorcontrib><creatorcontrib>Parekh, Amishi</creatorcontrib><creatorcontrib>Dadkhah, Shahriar</creatorcontrib><creatorcontrib>Peacock, W. Frank</creatorcontrib><title>Community hospital stethoscope cleaning practices and contamination rates</title><title>American journal of infection control</title><addtitle>Am J Infect Control</addtitle><description>•Stethoscope disinfection efficiency.•Hospital acquired infections caused by stethoscope.•Stethoscope cleaning practices.•Stethoscope contamination with bacteria.•Guidelines for stethoscope disinfection.
In the United States, nosocomial infections are estimated to cause 72,000 annual deaths. The stethoscope, commonly used, is rarely reported as a potential vector. Our study aims to describe stethoscope contamination and the effect of self-reported cleaning practices among health care providers in a community hospital setting.
Stethoscopes were collected at random times from health care providers and cultured per standard techniques. Providers answered a structured questionnaire related to their cleaning practices. Differences in bacterial growth rates and the impact of profession, cleaning frequency, and prior sanitization were evaluated.
Of 104 cultured stethoscopes, 44% were from residents and medical students, from which 76% had bacterial growth, and 56% were from attendings, nurses, and respiratory therapists who had 91.4% growth (95% = confidence interval 0.62-0.86 and 0.81-0.96, respectively). Overall, 86.5% of providers claimed disinfection frequency compliant with Center for Disease Control and Prevention guidelines but there were no statistical differences between self-reported cleaning frequency or methods, and the presence of bacteria.
Most stethoscopes are contaminated with bacteria, the presence of which was not affected by reported cleaning strategies.</description><subject>Cleaning strategies</subject><subject>Disinfection</subject><subject>Nosocomial infection</subject><subject>Sanitization methods</subject><subject>Stethoscope contamination</subject><issn>0196-6553</issn><issn>1527-3296</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAQhi0EoqXwBxhQRpYEO_5II7Ggio9KlVhgtmznAo4SO9guUv89qVoYmU5399wr3YPQNcEFwUTcdYXqrClKXOICswKT-gTNCS-rnJa1OEXzaSJywTmdoYsYO4xxTQU_RzNaUoErVs3ReuWHYets2mWfPo42qT6LCdLUGD9CZnpQzrqPbAzKJGsgZso1mfEuqcE6lax3WVAJ4iU6a1Uf4epYF-j96fFt9ZJvXp_Xq4dNbigXKQfSciyg0lSwZVtSyrQQDV-aShNFAZQmTFNol0QojLXWZtpQ3hLGWmYY0AW6PeSOwX9tISY52Gig75UDv42ypPWS8JpgPqHlATXBxxiglWOwgwo7SbDcK5Sd3CuUe4USMzkJm45ujvlbPUDzd_LrbALuDwBMX35bCDIaC85AYwOYJBtv_8v_ATLcg6M</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Alali, Sukaina Ali</creator><creator>Shrestha, Ekta</creator><creator>Kansakar, Aswin Ratna</creator><creator>Parekh, Amishi</creator><creator>Dadkhah, Shahriar</creator><creator>Peacock, W. Frank</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20201101</creationdate><title>Community hospital stethoscope cleaning practices and contamination rates</title><author>Alali, Sukaina Ali ; Shrestha, Ekta ; Kansakar, Aswin Ratna ; Parekh, Amishi ; Dadkhah, Shahriar ; Peacock, W. Frank</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-e1f506e7b3648f2334b66d58c7b1a3eeab14b3ef816a00bbbcc7b35f144f4c4e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Cleaning strategies</topic><topic>Disinfection</topic><topic>Nosocomial infection</topic><topic>Sanitization methods</topic><topic>Stethoscope contamination</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Alali, Sukaina Ali</creatorcontrib><creatorcontrib>Shrestha, Ekta</creatorcontrib><creatorcontrib>Kansakar, Aswin Ratna</creatorcontrib><creatorcontrib>Parekh, Amishi</creatorcontrib><creatorcontrib>Dadkhah, Shahriar</creatorcontrib><creatorcontrib>Peacock, W. Frank</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of infection control</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Alali, Sukaina Ali</au><au>Shrestha, Ekta</au><au>Kansakar, Aswin Ratna</au><au>Parekh, Amishi</au><au>Dadkhah, Shahriar</au><au>Peacock, W. Frank</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Community hospital stethoscope cleaning practices and contamination rates</atitle><jtitle>American journal of infection control</jtitle><addtitle>Am J Infect Control</addtitle><date>2020-11-01</date><risdate>2020</risdate><volume>48</volume><issue>11</issue><spage>1365</spage><epage>1369</epage><pages>1365-1369</pages><issn>0196-6553</issn><eissn>1527-3296</eissn><abstract>•Stethoscope disinfection efficiency.•Hospital acquired infections caused by stethoscope.•Stethoscope cleaning practices.•Stethoscope contamination with bacteria.•Guidelines for stethoscope disinfection.
In the United States, nosocomial infections are estimated to cause 72,000 annual deaths. The stethoscope, commonly used, is rarely reported as a potential vector. Our study aims to describe stethoscope contamination and the effect of self-reported cleaning practices among health care providers in a community hospital setting.
Stethoscopes were collected at random times from health care providers and cultured per standard techniques. Providers answered a structured questionnaire related to their cleaning practices. Differences in bacterial growth rates and the impact of profession, cleaning frequency, and prior sanitization were evaluated.
Of 104 cultured stethoscopes, 44% were from residents and medical students, from which 76% had bacterial growth, and 56% were from attendings, nurses, and respiratory therapists who had 91.4% growth (95% = confidence interval 0.62-0.86 and 0.81-0.96, respectively). Overall, 86.5% of providers claimed disinfection frequency compliant with Center for Disease Control and Prevention guidelines but there were no statistical differences between self-reported cleaning frequency or methods, and the presence of bacteria.
Most stethoscopes are contaminated with bacteria, the presence of which was not affected by reported cleaning strategies.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32360747</pmid><doi>10.1016/j.ajic.2020.04.019</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0196-6553 |
ispartof | American journal of infection control, 2020-11, Vol.48 (11), p.1365-1369 |
issn | 0196-6553 1527-3296 |
language | eng |
recordid | cdi_proquest_miscellaneous_2398159105 |
source | Elsevier ScienceDirect Journals Complete |
subjects | Cleaning strategies Disinfection Nosocomial infection Sanitization methods Stethoscope contamination |
title | Community hospital stethoscope cleaning practices and contamination rates |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T18%3A38%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Community%20hospital%20stethoscope%20cleaning%20practices%20and%20contamination%20rates&rft.jtitle=American%20journal%20of%20infection%20control&rft.au=Alali,%20Sukaina%20Ali&rft.date=2020-11-01&rft.volume=48&rft.issue=11&rft.spage=1365&rft.epage=1369&rft.pages=1365-1369&rft.issn=0196-6553&rft.eissn=1527-3296&rft_id=info:doi/10.1016/j.ajic.2020.04.019&rft_dat=%3Cproquest_cross%3E2398159105%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2398159105&rft_id=info:pmid/32360747&rft_els_id=S0196655320302662&rfr_iscdi=true |