Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams

Positron emission tomography (PET) has been used for dose verification in charged particle therapy. The causes of washout of positron emitters by physiological functions should be clarified for accurate dose verification. In this study, we visualized the distribution of irradiated radioactive beams,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2020-05, Vol.65 (10), p.105011-105011
Hauptverfasser: Toramatsu, Chie, Mohammadi, Akram, Wakizaka, Hidekazu, Seki, Chie, Nishikido, Fumihiko, Sato, Shinji, Kanno, Iwao, Takahashi, Miwako, Karasawa, Kumiko, Hirano, Yoshiyuki, Yamaya, Taiga
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 105011
container_issue 10
container_start_page 105011
container_title Physics in medicine & biology
container_volume 65
creator Toramatsu, Chie
Mohammadi, Akram
Wakizaka, Hidekazu
Seki, Chie
Nishikido, Fumihiko
Sato, Shinji
Kanno, Iwao
Takahashi, Miwako
Karasawa, Kumiko
Hirano, Yoshiyuki
Yamaya, Taiga
description Positron emission tomography (PET) has been used for dose verification in charged particle therapy. The causes of washout of positron emitters by physiological functions should be clarified for accurate dose verification. In this study, we visualized the distribution of irradiated radioactive beams, 11C and 15O beams, in the rabbit whole-body using our original depth-of-interaction (DOI)-PET prototype to add basic data for biological washout effect correction. Time activity curves of the irradiated field and organs were measured immediately after the irradiations. All data were corrected for physical decay before further analysis. We also collected expired gas of the rabbit during beam irradiation and the energy spectrum was measured with a germanium detector. Irradiated radioactive beams into the brain were distributed to the whole body due to the biological washout process, and the implanted 11C and 15O ions were concentrated in the regions which had high blood volume. The 11C-labelled 11CO2 was detected in expired gas under the 11C beam irradiation, while no significant signal was detected under the 15O beam irradiation as a form of C15O2. Results suggested that the implanted 11C ions form molecules that diffuse out to the whole body by undergoing perfusion, then, they are incorporated into the blood-gas exchange in the respiratory system. This study provides basic data for modelling of the biological washout effect.
doi_str_mv 10.1088/1361-6560/ab8532
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_2385731249</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2385731249</sourcerecordid><originalsourceid>FETCH-LOGICAL-i211t-df9a42000f6a1c5c307592906e610d317375165d823a4b1ed1ed70ff76f63d0c3</originalsourceid><addsrcrecordid>eNpVkEtLxDAQgIMo7vq4e5IcPVidSTZp602X9QGCHvQckqbVLG1T0xbx35u1PhAGBoZvXh8hRwhnCFl2jlxiIoWEc20ywdkWmf-WtskcgGOSoxAzstf3awDEjC12yYwzxgWIdE7UlfO1f3GFrum77l_9ONDG27KuXftCKx-oaxNT6oY-rp4uaNDGuIGaoF1LXQjaOj0431LzQRGXVLeWonigX6XY1R-QnUrXfXn4nffJ8_XqaXmb3D_c3C0v7xPHEIfEVrleMACopMZCFBxSkbMcZCkRLMeUpwKlsBnjemGwtDFSqKpUVpJbKPg-OZnmdsG_jWU_qMb1RXxDt6Ufe8V4JlKObJFH9PgbHU1TWtUF1-jwoX6kROB0Apzv1NqPoY2XKwS1ca42gtVGsJqc_63-h3eNidTUJaJ41dmKfwK7Xnw_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2385731249</pqid></control><display><type>article</type><title>Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Toramatsu, Chie ; Mohammadi, Akram ; Wakizaka, Hidekazu ; Seki, Chie ; Nishikido, Fumihiko ; Sato, Shinji ; Kanno, Iwao ; Takahashi, Miwako ; Karasawa, Kumiko ; Hirano, Yoshiyuki ; Yamaya, Taiga</creator><creatorcontrib>Toramatsu, Chie ; Mohammadi, Akram ; Wakizaka, Hidekazu ; Seki, Chie ; Nishikido, Fumihiko ; Sato, Shinji ; Kanno, Iwao ; Takahashi, Miwako ; Karasawa, Kumiko ; Hirano, Yoshiyuki ; Yamaya, Taiga</creatorcontrib><description>Positron emission tomography (PET) has been used for dose verification in charged particle therapy. The causes of washout of positron emitters by physiological functions should be clarified for accurate dose verification. In this study, we visualized the distribution of irradiated radioactive beams, 11C and 15O beams, in the rabbit whole-body using our original depth-of-interaction (DOI)-PET prototype to add basic data for biological washout effect correction. Time activity curves of the irradiated field and organs were measured immediately after the irradiations. All data were corrected for physical decay before further analysis. We also collected expired gas of the rabbit during beam irradiation and the energy spectrum was measured with a germanium detector. Irradiated radioactive beams into the brain were distributed to the whole body due to the biological washout process, and the implanted 11C and 15O ions were concentrated in the regions which had high blood volume. The 11C-labelled 11CO2 was detected in expired gas under the 11C beam irradiation, while no significant signal was detected under the 15O beam irradiation as a form of C15O2. Results suggested that the implanted 11C ions form molecules that diffuse out to the whole body by undergoing perfusion, then, they are incorporated into the blood-gas exchange in the respiratory system. This study provides basic data for modelling of the biological washout effect.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/ab8532</identifier><identifier>PMID: 32235057</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>adaptive therapy ; biological model ; biological washout effect ; in-beam PET ; particle therapy ; rabbit brain ; radioisotope beam</subject><ispartof>Physics in medicine &amp; biology, 2020-05, Vol.65 (10), p.105011-105011</ispartof><rights>2020 Institute of Physics and Engineering in Medicine</rights><rights>2020 Institute of Physics and Engineering in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0003-2334-1986 ; 0000-0002-3274-4261</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/ab8532/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53821,53868</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32235057$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Toramatsu, Chie</creatorcontrib><creatorcontrib>Mohammadi, Akram</creatorcontrib><creatorcontrib>Wakizaka, Hidekazu</creatorcontrib><creatorcontrib>Seki, Chie</creatorcontrib><creatorcontrib>Nishikido, Fumihiko</creatorcontrib><creatorcontrib>Sato, Shinji</creatorcontrib><creatorcontrib>Kanno, Iwao</creatorcontrib><creatorcontrib>Takahashi, Miwako</creatorcontrib><creatorcontrib>Karasawa, Kumiko</creatorcontrib><creatorcontrib>Hirano, Yoshiyuki</creatorcontrib><creatorcontrib>Yamaya, Taiga</creatorcontrib><title>Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Positron emission tomography (PET) has been used for dose verification in charged particle therapy. The causes of washout of positron emitters by physiological functions should be clarified for accurate dose verification. In this study, we visualized the distribution of irradiated radioactive beams, 11C and 15O beams, in the rabbit whole-body using our original depth-of-interaction (DOI)-PET prototype to add basic data for biological washout effect correction. Time activity curves of the irradiated field and organs were measured immediately after the irradiations. All data were corrected for physical decay before further analysis. We also collected expired gas of the rabbit during beam irradiation and the energy spectrum was measured with a germanium detector. Irradiated radioactive beams into the brain were distributed to the whole body due to the biological washout process, and the implanted 11C and 15O ions were concentrated in the regions which had high blood volume. The 11C-labelled 11CO2 was detected in expired gas under the 11C beam irradiation, while no significant signal was detected under the 15O beam irradiation as a form of C15O2. Results suggested that the implanted 11C ions form molecules that diffuse out to the whole body by undergoing perfusion, then, they are incorporated into the blood-gas exchange in the respiratory system. This study provides basic data for modelling of the biological washout effect.</description><subject>adaptive therapy</subject><subject>biological model</subject><subject>biological washout effect</subject><subject>in-beam PET</subject><subject>particle therapy</subject><subject>rabbit brain</subject><subject>radioisotope beam</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpVkEtLxDAQgIMo7vq4e5IcPVidSTZp602X9QGCHvQckqbVLG1T0xbx35u1PhAGBoZvXh8hRwhnCFl2jlxiIoWEc20ywdkWmf-WtskcgGOSoxAzstf3awDEjC12yYwzxgWIdE7UlfO1f3GFrum77l_9ONDG27KuXftCKx-oaxNT6oY-rp4uaNDGuIGaoF1LXQjaOj0431LzQRGXVLeWonigX6XY1R-QnUrXfXn4nffJ8_XqaXmb3D_c3C0v7xPHEIfEVrleMACopMZCFBxSkbMcZCkRLMeUpwKlsBnjemGwtDFSqKpUVpJbKPg-OZnmdsG_jWU_qMb1RXxDt6Ufe8V4JlKObJFH9PgbHU1TWtUF1-jwoX6kROB0Apzv1NqPoY2XKwS1ca42gtVGsJqc_63-h3eNidTUJaJ41dmKfwK7Xnw_</recordid><startdate>20200521</startdate><enddate>20200521</enddate><creator>Toramatsu, Chie</creator><creator>Mohammadi, Akram</creator><creator>Wakizaka, Hidekazu</creator><creator>Seki, Chie</creator><creator>Nishikido, Fumihiko</creator><creator>Sato, Shinji</creator><creator>Kanno, Iwao</creator><creator>Takahashi, Miwako</creator><creator>Karasawa, Kumiko</creator><creator>Hirano, Yoshiyuki</creator><creator>Yamaya, Taiga</creator><general>IOP Publishing</general><scope>NPM</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-2334-1986</orcidid><orcidid>https://orcid.org/0000-0002-3274-4261</orcidid></search><sort><creationdate>20200521</creationdate><title>Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams</title><author>Toramatsu, Chie ; Mohammadi, Akram ; Wakizaka, Hidekazu ; Seki, Chie ; Nishikido, Fumihiko ; Sato, Shinji ; Kanno, Iwao ; Takahashi, Miwako ; Karasawa, Kumiko ; Hirano, Yoshiyuki ; Yamaya, Taiga</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i211t-df9a42000f6a1c5c307592906e610d317375165d823a4b1ed1ed70ff76f63d0c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>adaptive therapy</topic><topic>biological model</topic><topic>biological washout effect</topic><topic>in-beam PET</topic><topic>particle therapy</topic><topic>rabbit brain</topic><topic>radioisotope beam</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Toramatsu, Chie</creatorcontrib><creatorcontrib>Mohammadi, Akram</creatorcontrib><creatorcontrib>Wakizaka, Hidekazu</creatorcontrib><creatorcontrib>Seki, Chie</creatorcontrib><creatorcontrib>Nishikido, Fumihiko</creatorcontrib><creatorcontrib>Sato, Shinji</creatorcontrib><creatorcontrib>Kanno, Iwao</creatorcontrib><creatorcontrib>Takahashi, Miwako</creatorcontrib><creatorcontrib>Karasawa, Kumiko</creatorcontrib><creatorcontrib>Hirano, Yoshiyuki</creatorcontrib><creatorcontrib>Yamaya, Taiga</creatorcontrib><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Toramatsu, Chie</au><au>Mohammadi, Akram</au><au>Wakizaka, Hidekazu</au><au>Seki, Chie</au><au>Nishikido, Fumihiko</au><au>Sato, Shinji</au><au>Kanno, Iwao</au><au>Takahashi, Miwako</au><au>Karasawa, Kumiko</au><au>Hirano, Yoshiyuki</au><au>Yamaya, Taiga</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2020-05-21</date><risdate>2020</risdate><volume>65</volume><issue>10</issue><spage>105011</spage><epage>105011</epage><pages>105011-105011</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Positron emission tomography (PET) has been used for dose verification in charged particle therapy. The causes of washout of positron emitters by physiological functions should be clarified for accurate dose verification. In this study, we visualized the distribution of irradiated radioactive beams, 11C and 15O beams, in the rabbit whole-body using our original depth-of-interaction (DOI)-PET prototype to add basic data for biological washout effect correction. Time activity curves of the irradiated field and organs were measured immediately after the irradiations. All data were corrected for physical decay before further analysis. We also collected expired gas of the rabbit during beam irradiation and the energy spectrum was measured with a germanium detector. Irradiated radioactive beams into the brain were distributed to the whole body due to the biological washout process, and the implanted 11C and 15O ions were concentrated in the regions which had high blood volume. The 11C-labelled 11CO2 was detected in expired gas under the 11C beam irradiation, while no significant signal was detected under the 15O beam irradiation as a form of C15O2. Results suggested that the implanted 11C ions form molecules that diffuse out to the whole body by undergoing perfusion, then, they are incorporated into the blood-gas exchange in the respiratory system. This study provides basic data for modelling of the biological washout effect.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>32235057</pmid><doi>10.1088/1361-6560/ab8532</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0003-2334-1986</orcidid><orcidid>https://orcid.org/0000-0002-3274-4261</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2020-05, Vol.65 (10), p.105011-105011
issn 0031-9155
1361-6560
language eng
recordid cdi_proquest_miscellaneous_2385731249
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects adaptive therapy
biological model
biological washout effect
in-beam PET
particle therapy
rabbit brain
radioisotope beam
title Biological washout modelling for in-beam PET: rabbit brain irradiation by 11C and 15O ion beams
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T15%3A02%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biological%20washout%20modelling%20for%20in-beam%20PET:%20rabbit%20brain%20irradiation%20by%2011C%20and%2015O%20ion%20beams&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Toramatsu,%20Chie&rft.date=2020-05-21&rft.volume=65&rft.issue=10&rft.spage=105011&rft.epage=105011&rft.pages=105011-105011&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/ab8532&rft_dat=%3Cproquest_pubme%3E2385731249%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2385731249&rft_id=info:pmid/32235057&rfr_iscdi=true