SVPWM control strategy for a three phase five level dual inverter fed open-end winding induction motor

A Space Vector Pulse Width Modulation (SVPWM) control strategy is proposed for a three phase five level dual inverter fed open-end winding induction motor. This system includes 2 three level Neutral Point Clamped (NPC) inverters, which is supplied by two isolated dc power supplies. The conventional...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ISA transactions 2020-07, Vol.102, p.105-116
Hauptverfasser: Ramasamy, Palanisamy, Krishnasamy, Vijayakumar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 116
container_issue
container_start_page 105
container_title ISA transactions
container_volume 102
creator Ramasamy, Palanisamy
Krishnasamy, Vijayakumar
description A Space Vector Pulse Width Modulation (SVPWM) control strategy is proposed for a three phase five level dual inverter fed open-end winding induction motor. This system includes 2 three level Neutral Point Clamped (NPC) inverters, which is supplied by two isolated dc power supplies. The conventional SVPWM has more complexity in reference vector identification and switching time calculation. The reference vector for proposed five level SVPWM scheme is tracked using three level voltage vector and offset voltage, where 5-level hexagonal region is divided into seven 3-level hexagonal regions. The proposed SVPWM leads to reduce the complexity in switching time calculation, Total Harmonic Distortion (THD) reduction, Minimization of Common Mode Voltage (CMV) and low voltage stresses across the switching devices. Also this system estimate the phase current of the five level dual inverter fed open-end winding induction motor. The results obtained using simulation and hardware are compared and verified using Digital Signal Processor. [Display omitted] •Common Mode Voltage of 5-level dual NPC inverter is minimized to 24.5 V, which is Vdc/12 times of input voltage.•THD is reduced to 0.21% for output voltage and 2.75% for output current of 5-level dual NPC inverter.•Three phase five level output is generated using 2 three level NPC inverter with open-end winding induction motor using SVPWM scheme.•This system reduces the complexity in switching time calculation and reference vector identification.
doi_str_mv 10.1016/j.isatra.2020.02.034
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2377343541</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0019057820300987</els_id><sourcerecordid>2377343541</sourcerecordid><originalsourceid>FETCH-LOGICAL-c362t-b2c5d27e17d3d4b721cecc79d37cd1e2ba2dd91ee0bfc698b51fe5ed4731147b3</originalsourceid><addsrcrecordid>eNp9kEtLAzEQx4Motla_gUiOXnbNY7fpXgQpvqCi4OsYssmspmyTmmQr_fZuafXoaWDm_2B-CJ1SklNCxxfz3EaVgsoZYSQnLCe82ENDOhFV1q_YPhoSQquMlGIyQEcxzgkhrKwmh2jAGR1XrGJD1Dy_Pb0_YO1dCr7FsQ9M8LHGjQ9Y4fQZAPDyU0XAjV0BbmEFLTadarF1KwgJAm7AYL8El4Ez-Ns6Y91HfzWdTtY7vPDJh2N00Kg2wslujtDrzfXL9C6bPd7eT69mmeZjlrKa6dIwAVQYbopaMKpBa1EZLrShwGrFjKkoAKkbPa4mdUkbKMEUglNaiJqP0Pk2dxn8VwcxyYWNGtpWOfBdlIwLwQteFrSXFlupDj7GAI1cBrtQYS0pkRvCci63hOWGsCRM9oR729muoasXYP5Mv0h7weVWAP2fKwtBRm3BaTA2gE7SePt_ww-eIpAt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2377343541</pqid></control><display><type>article</type><title>SVPWM control strategy for a three phase five level dual inverter fed open-end winding induction motor</title><source>Access via ScienceDirect (Elsevier)</source><creator>Ramasamy, Palanisamy ; Krishnasamy, Vijayakumar</creator><creatorcontrib>Ramasamy, Palanisamy ; Krishnasamy, Vijayakumar</creatorcontrib><description>A Space Vector Pulse Width Modulation (SVPWM) control strategy is proposed for a three phase five level dual inverter fed open-end winding induction motor. This system includes 2 three level Neutral Point Clamped (NPC) inverters, which is supplied by two isolated dc power supplies. The conventional SVPWM has more complexity in reference vector identification and switching time calculation. The reference vector for proposed five level SVPWM scheme is tracked using three level voltage vector and offset voltage, where 5-level hexagonal region is divided into seven 3-level hexagonal regions. The proposed SVPWM leads to reduce the complexity in switching time calculation, Total Harmonic Distortion (THD) reduction, Minimization of Common Mode Voltage (CMV) and low voltage stresses across the switching devices. Also this system estimate the phase current of the five level dual inverter fed open-end winding induction motor. The results obtained using simulation and hardware are compared and verified using Digital Signal Processor. [Display omitted] •Common Mode Voltage of 5-level dual NPC inverter is minimized to 24.5 V, which is Vdc/12 times of input voltage.•THD is reduced to 0.21% for output voltage and 2.75% for output current of 5-level dual NPC inverter.•Three phase five level output is generated using 2 three level NPC inverter with open-end winding induction motor using SVPWM scheme.•This system reduces the complexity in switching time calculation and reference vector identification.</description><identifier>ISSN: 0019-0578</identifier><identifier>EISSN: 1879-2022</identifier><identifier>DOI: 10.1016/j.isatra.2020.02.034</identifier><identifier>PMID: 32169292</identifier><language>eng</language><publisher>United States: Elsevier Ltd</publisher><subject>Common Mode Voltage (CMV) ; Dual inverter ; Neutral Point Clamped (NPC) inverter ; Open-end winding induction motor ; Space Vector Pulse Width Modulation (SVPWM) ; Total Harmonic Distortion (THD)</subject><ispartof>ISA transactions, 2020-07, Vol.102, p.105-116</ispartof><rights>2020 ISA</rights><rights>Copyright © 2020 ISA. Published by Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c362t-b2c5d27e17d3d4b721cecc79d37cd1e2ba2dd91ee0bfc698b51fe5ed4731147b3</citedby><cites>FETCH-LOGICAL-c362t-b2c5d27e17d3d4b721cecc79d37cd1e2ba2dd91ee0bfc698b51fe5ed4731147b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.isatra.2020.02.034$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32169292$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ramasamy, Palanisamy</creatorcontrib><creatorcontrib>Krishnasamy, Vijayakumar</creatorcontrib><title>SVPWM control strategy for a three phase five level dual inverter fed open-end winding induction motor</title><title>ISA transactions</title><addtitle>ISA Trans</addtitle><description>A Space Vector Pulse Width Modulation (SVPWM) control strategy is proposed for a three phase five level dual inverter fed open-end winding induction motor. This system includes 2 three level Neutral Point Clamped (NPC) inverters, which is supplied by two isolated dc power supplies. The conventional SVPWM has more complexity in reference vector identification and switching time calculation. The reference vector for proposed five level SVPWM scheme is tracked using three level voltage vector and offset voltage, where 5-level hexagonal region is divided into seven 3-level hexagonal regions. The proposed SVPWM leads to reduce the complexity in switching time calculation, Total Harmonic Distortion (THD) reduction, Minimization of Common Mode Voltage (CMV) and low voltage stresses across the switching devices. Also this system estimate the phase current of the five level dual inverter fed open-end winding induction motor. The results obtained using simulation and hardware are compared and verified using Digital Signal Processor. [Display omitted] •Common Mode Voltage of 5-level dual NPC inverter is minimized to 24.5 V, which is Vdc/12 times of input voltage.•THD is reduced to 0.21% for output voltage and 2.75% for output current of 5-level dual NPC inverter.•Three phase five level output is generated using 2 three level NPC inverter with open-end winding induction motor using SVPWM scheme.•This system reduces the complexity in switching time calculation and reference vector identification.</description><subject>Common Mode Voltage (CMV)</subject><subject>Dual inverter</subject><subject>Neutral Point Clamped (NPC) inverter</subject><subject>Open-end winding induction motor</subject><subject>Space Vector Pulse Width Modulation (SVPWM)</subject><subject>Total Harmonic Distortion (THD)</subject><issn>0019-0578</issn><issn>1879-2022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kEtLAzEQx4Motla_gUiOXnbNY7fpXgQpvqCi4OsYssmspmyTmmQr_fZuafXoaWDm_2B-CJ1SklNCxxfz3EaVgsoZYSQnLCe82ENDOhFV1q_YPhoSQquMlGIyQEcxzgkhrKwmh2jAGR1XrGJD1Dy_Pb0_YO1dCr7FsQ9M8LHGjQ9Y4fQZAPDyU0XAjV0BbmEFLTadarF1KwgJAm7AYL8El4Ez-Ns6Y91HfzWdTtY7vPDJh2N00Kg2wslujtDrzfXL9C6bPd7eT69mmeZjlrKa6dIwAVQYbopaMKpBa1EZLrShwGrFjKkoAKkbPa4mdUkbKMEUglNaiJqP0Pk2dxn8VwcxyYWNGtpWOfBdlIwLwQteFrSXFlupDj7GAI1cBrtQYS0pkRvCci63hOWGsCRM9oR729muoasXYP5Mv0h7weVWAP2fKwtBRm3BaTA2gE7SePt_ww-eIpAt</recordid><startdate>20200701</startdate><enddate>20200701</enddate><creator>Ramasamy, Palanisamy</creator><creator>Krishnasamy, Vijayakumar</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20200701</creationdate><title>SVPWM control strategy for a three phase five level dual inverter fed open-end winding induction motor</title><author>Ramasamy, Palanisamy ; Krishnasamy, Vijayakumar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c362t-b2c5d27e17d3d4b721cecc79d37cd1e2ba2dd91ee0bfc698b51fe5ed4731147b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Common Mode Voltage (CMV)</topic><topic>Dual inverter</topic><topic>Neutral Point Clamped (NPC) inverter</topic><topic>Open-end winding induction motor</topic><topic>Space Vector Pulse Width Modulation (SVPWM)</topic><topic>Total Harmonic Distortion (THD)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ramasamy, Palanisamy</creatorcontrib><creatorcontrib>Krishnasamy, Vijayakumar</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>ISA transactions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ramasamy, Palanisamy</au><au>Krishnasamy, Vijayakumar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SVPWM control strategy for a three phase five level dual inverter fed open-end winding induction motor</atitle><jtitle>ISA transactions</jtitle><addtitle>ISA Trans</addtitle><date>2020-07-01</date><risdate>2020</risdate><volume>102</volume><spage>105</spage><epage>116</epage><pages>105-116</pages><issn>0019-0578</issn><eissn>1879-2022</eissn><abstract>A Space Vector Pulse Width Modulation (SVPWM) control strategy is proposed for a three phase five level dual inverter fed open-end winding induction motor. This system includes 2 three level Neutral Point Clamped (NPC) inverters, which is supplied by two isolated dc power supplies. The conventional SVPWM has more complexity in reference vector identification and switching time calculation. The reference vector for proposed five level SVPWM scheme is tracked using three level voltage vector and offset voltage, where 5-level hexagonal region is divided into seven 3-level hexagonal regions. The proposed SVPWM leads to reduce the complexity in switching time calculation, Total Harmonic Distortion (THD) reduction, Minimization of Common Mode Voltage (CMV) and low voltage stresses across the switching devices. Also this system estimate the phase current of the five level dual inverter fed open-end winding induction motor. The results obtained using simulation and hardware are compared and verified using Digital Signal Processor. [Display omitted] •Common Mode Voltage of 5-level dual NPC inverter is minimized to 24.5 V, which is Vdc/12 times of input voltage.•THD is reduced to 0.21% for output voltage and 2.75% for output current of 5-level dual NPC inverter.•Three phase five level output is generated using 2 three level NPC inverter with open-end winding induction motor using SVPWM scheme.•This system reduces the complexity in switching time calculation and reference vector identification.</abstract><cop>United States</cop><pub>Elsevier Ltd</pub><pmid>32169292</pmid><doi>10.1016/j.isatra.2020.02.034</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0019-0578
ispartof ISA transactions, 2020-07, Vol.102, p.105-116
issn 0019-0578
1879-2022
language eng
recordid cdi_proquest_miscellaneous_2377343541
source Access via ScienceDirect (Elsevier)
subjects Common Mode Voltage (CMV)
Dual inverter
Neutral Point Clamped (NPC) inverter
Open-end winding induction motor
Space Vector Pulse Width Modulation (SVPWM)
Total Harmonic Distortion (THD)
title SVPWM control strategy for a three phase five level dual inverter fed open-end winding induction motor
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T06%3A42%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SVPWM%20control%20strategy%20for%20a%20three%20phase%20five%20level%20dual%20inverter%20fed%20open-end%20winding%20induction%20motor&rft.jtitle=ISA%20transactions&rft.au=Ramasamy,%20Palanisamy&rft.date=2020-07-01&rft.volume=102&rft.spage=105&rft.epage=116&rft.pages=105-116&rft.issn=0019-0578&rft.eissn=1879-2022&rft_id=info:doi/10.1016/j.isatra.2020.02.034&rft_dat=%3Cproquest_cross%3E2377343541%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2377343541&rft_id=info:pmid/32169292&rft_els_id=S0019057820300987&rfr_iscdi=true