Diagnosis of slow ventricular tachycardia by cardiac resynchronization devices utilizing a desynchronization detection algorithm

Some cardiac resynchronization therapy (CRT) devices equipped with left ventricular (LV) sensing can develop a specific desynchronization rhythm. Contemporary BIOTRONIK devices are designed with an algorithm called “CRT pacing interrupt” exclusively designed to record the occurrence of the specific...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of electrocardiology 2020-03, Vol.59, p.140-146
Hauptverfasser: Barold, S. Serge, Kucher, Andreas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 146
container_issue
container_start_page 140
container_title Journal of electrocardiology
container_volume 59
creator Barold, S. Serge
Kucher, Andreas
description Some cardiac resynchronization therapy (CRT) devices equipped with left ventricular (LV) sensing can develop a specific desynchronization rhythm. Contemporary BIOTRONIK devices are designed with an algorithm called “CRT pacing interrupt” exclusively designed to record the occurrence of the specific form of desynchronization. We report six patients in whom the CRT pacing interrupt function permitted the diagnosis of slow ventricular tachycardia (VT). Slow VT was defined as slower than the programmed VT intervention rates. Although the CRT pacing interrupt function is not designed to detect slow VT, certain episodes of the CRT pacing interrupt function were falsely interpreted by the device as a desynchronization arrhythmia, and the recordings then provided data consistent with the presence of slow VT. The CRT pacing interrupt algorithm permitted a diagnosis of slow VT irrespective of the relationship of LV upper rate interval and cycle length of slow VT.
doi_str_mv 10.1016/j.jelectrocard.2020.02.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2369411268</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022073619309628</els_id><sourcerecordid>2444986042</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-535ef7b2e71a19c5a8362fded83062dfc4d7d4d2911ce6751affb4900007f6a43</originalsourceid><addsrcrecordid>eNqNkU1v1DAQhi0EokvhLyALLlwSxh9xEm6o5UuqxKU9W157vOsoGxc7WbQ98dPr1RaE6IXTjEbPzPvaLyFvGNQMmHo_1AOOaOcUrUmu5sChBl4DtE_IijWCV50U8JSsADivoBXqjLzIeQCAnrf8OTkTnEHTQbMivy6D2Uwxh0yjp3mMP-kepzkFu4wm0dnY7eGoEgxdH-ipszRhPkx2m-IU7swc4kQd7oPFTJc5jOEuTBtqyuwxNRffx86Mm5jCvN29JM-8GTO-eqjn5Obzp-uLr9XV9y_fLj5eVVZCN1eNaNC3a44tM6y3jemE4t6h6wQo7ryVrnXS8Z4xi6ptmPF-LfvyZGi9MlKck3enu7cp_lgwz3oXssVxNBPGJWsuVC8Z46or6Nt_0CEuaSruNJdS9p0CyQv14UTZFHNO6PVtCjuTDpqBPuakB_13TvqYkwaui6Oy_PpBYlnv0P1Z_R1MAS5PAJY_2QdMOtuAk0UXUjmpXQz_o3MPy8iuUA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2444986042</pqid></control><display><type>article</type><title>Diagnosis of slow ventricular tachycardia by cardiac resynchronization devices utilizing a desynchronization detection algorithm</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Barold, S. Serge ; Kucher, Andreas</creator><creatorcontrib>Barold, S. Serge ; Kucher, Andreas</creatorcontrib><description>Some cardiac resynchronization therapy (CRT) devices equipped with left ventricular (LV) sensing can develop a specific desynchronization rhythm. Contemporary BIOTRONIK devices are designed with an algorithm called “CRT pacing interrupt” exclusively designed to record the occurrence of the specific form of desynchronization. We report six patients in whom the CRT pacing interrupt function permitted the diagnosis of slow ventricular tachycardia (VT). Slow VT was defined as slower than the programmed VT intervention rates. Although the CRT pacing interrupt function is not designed to detect slow VT, certain episodes of the CRT pacing interrupt function were falsely interpreted by the device as a desynchronization arrhythmia, and the recordings then provided data consistent with the presence of slow VT. The CRT pacing interrupt algorithm permitted a diagnosis of slow VT irrespective of the relationship of LV upper rate interval and cycle length of slow VT.</description><identifier>ISSN: 0022-0736</identifier><identifier>EISSN: 1532-8430</identifier><identifier>DOI: 10.1016/j.jelectrocard.2020.02.007</identifier><identifier>PMID: 32105805</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Cardiac arrhythmia ; Cardiac resynchronization therapy ; Cardiovascular disease ; Desynchronization rhythm ; Electrocardiography ; Left ventricular pacing ; Medical diagnosis ; Ventricular tachycardia</subject><ispartof>Journal of electrocardiology, 2020-03, Vol.59, p.140-146</ispartof><rights>2020 Elsevier Inc.</rights><rights>Copyright © 2020 Elsevier Inc. All rights reserved.</rights><rights>Copyright Elsevier Science Ltd. Mar/Apr 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-535ef7b2e71a19c5a8362fded83062dfc4d7d4d2911ce6751affb4900007f6a43</citedby><cites>FETCH-LOGICAL-c408t-535ef7b2e71a19c5a8362fded83062dfc4d7d4d2911ce6751affb4900007f6a43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jelectrocard.2020.02.007$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32105805$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Barold, S. Serge</creatorcontrib><creatorcontrib>Kucher, Andreas</creatorcontrib><title>Diagnosis of slow ventricular tachycardia by cardiac resynchronization devices utilizing a desynchronization detection algorithm</title><title>Journal of electrocardiology</title><addtitle>J Electrocardiol</addtitle><description>Some cardiac resynchronization therapy (CRT) devices equipped with left ventricular (LV) sensing can develop a specific desynchronization rhythm. Contemporary BIOTRONIK devices are designed with an algorithm called “CRT pacing interrupt” exclusively designed to record the occurrence of the specific form of desynchronization. We report six patients in whom the CRT pacing interrupt function permitted the diagnosis of slow ventricular tachycardia (VT). Slow VT was defined as slower than the programmed VT intervention rates. Although the CRT pacing interrupt function is not designed to detect slow VT, certain episodes of the CRT pacing interrupt function were falsely interpreted by the device as a desynchronization arrhythmia, and the recordings then provided data consistent with the presence of slow VT. The CRT pacing interrupt algorithm permitted a diagnosis of slow VT irrespective of the relationship of LV upper rate interval and cycle length of slow VT.</description><subject>Cardiac arrhythmia</subject><subject>Cardiac resynchronization therapy</subject><subject>Cardiovascular disease</subject><subject>Desynchronization rhythm</subject><subject>Electrocardiography</subject><subject>Left ventricular pacing</subject><subject>Medical diagnosis</subject><subject>Ventricular tachycardia</subject><issn>0022-0736</issn><issn>1532-8430</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqNkU1v1DAQhi0EokvhLyALLlwSxh9xEm6o5UuqxKU9W157vOsoGxc7WbQ98dPr1RaE6IXTjEbPzPvaLyFvGNQMmHo_1AOOaOcUrUmu5sChBl4DtE_IijWCV50U8JSsADivoBXqjLzIeQCAnrf8OTkTnEHTQbMivy6D2Uwxh0yjp3mMP-kepzkFu4wm0dnY7eGoEgxdH-ipszRhPkx2m-IU7swc4kQd7oPFTJc5jOEuTBtqyuwxNRffx86Mm5jCvN29JM-8GTO-eqjn5Obzp-uLr9XV9y_fLj5eVVZCN1eNaNC3a44tM6y3jemE4t6h6wQo7ryVrnXS8Z4xi6ptmPF-LfvyZGi9MlKck3enu7cp_lgwz3oXssVxNBPGJWsuVC8Z46or6Nt_0CEuaSruNJdS9p0CyQv14UTZFHNO6PVtCjuTDpqBPuakB_13TvqYkwaui6Oy_PpBYlnv0P1Z_R1MAS5PAJY_2QdMOtuAk0UXUjmpXQz_o3MPy8iuUA</recordid><startdate>202003</startdate><enddate>202003</enddate><creator>Barold, S. Serge</creator><creator>Kucher, Andreas</creator><general>Elsevier Inc</general><general>Elsevier Science Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope></search><sort><creationdate>202003</creationdate><title>Diagnosis of slow ventricular tachycardia by cardiac resynchronization devices utilizing a desynchronization detection algorithm</title><author>Barold, S. Serge ; Kucher, Andreas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-535ef7b2e71a19c5a8362fded83062dfc4d7d4d2911ce6751affb4900007f6a43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Cardiac arrhythmia</topic><topic>Cardiac resynchronization therapy</topic><topic>Cardiovascular disease</topic><topic>Desynchronization rhythm</topic><topic>Electrocardiography</topic><topic>Left ventricular pacing</topic><topic>Medical diagnosis</topic><topic>Ventricular tachycardia</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Barold, S. Serge</creatorcontrib><creatorcontrib>Kucher, Andreas</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of electrocardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Barold, S. Serge</au><au>Kucher, Andreas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnosis of slow ventricular tachycardia by cardiac resynchronization devices utilizing a desynchronization detection algorithm</atitle><jtitle>Journal of electrocardiology</jtitle><addtitle>J Electrocardiol</addtitle><date>2020-03</date><risdate>2020</risdate><volume>59</volume><spage>140</spage><epage>146</epage><pages>140-146</pages><issn>0022-0736</issn><eissn>1532-8430</eissn><abstract>Some cardiac resynchronization therapy (CRT) devices equipped with left ventricular (LV) sensing can develop a specific desynchronization rhythm. Contemporary BIOTRONIK devices are designed with an algorithm called “CRT pacing interrupt” exclusively designed to record the occurrence of the specific form of desynchronization. We report six patients in whom the CRT pacing interrupt function permitted the diagnosis of slow ventricular tachycardia (VT). Slow VT was defined as slower than the programmed VT intervention rates. Although the CRT pacing interrupt function is not designed to detect slow VT, certain episodes of the CRT pacing interrupt function were falsely interpreted by the device as a desynchronization arrhythmia, and the recordings then provided data consistent with the presence of slow VT. The CRT pacing interrupt algorithm permitted a diagnosis of slow VT irrespective of the relationship of LV upper rate interval and cycle length of slow VT.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32105805</pmid><doi>10.1016/j.jelectrocard.2020.02.007</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-0736
ispartof Journal of electrocardiology, 2020-03, Vol.59, p.140-146
issn 0022-0736
1532-8430
language eng
recordid cdi_proquest_miscellaneous_2369411268
source Elsevier ScienceDirect Journals Complete
subjects Cardiac arrhythmia
Cardiac resynchronization therapy
Cardiovascular disease
Desynchronization rhythm
Electrocardiography
Left ventricular pacing
Medical diagnosis
Ventricular tachycardia
title Diagnosis of slow ventricular tachycardia by cardiac resynchronization devices utilizing a desynchronization detection algorithm
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T12%3A18%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnosis%20of%20slow%20ventricular%20tachycardia%20by%20cardiac%20resynchronization%20devices%20utilizing%20a%20desynchronization%20detection%20algorithm&rft.jtitle=Journal%20of%20electrocardiology&rft.au=Barold,%20S.%20Serge&rft.date=2020-03&rft.volume=59&rft.spage=140&rft.epage=146&rft.pages=140-146&rft.issn=0022-0736&rft.eissn=1532-8430&rft_id=info:doi/10.1016/j.jelectrocard.2020.02.007&rft_dat=%3Cproquest_cross%3E2444986042%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2444986042&rft_id=info:pmid/32105805&rft_els_id=S0022073619309628&rfr_iscdi=true