Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique

Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2020-01, Vol.45 (3), p.252-255
Hauptverfasser: Miura, Hideharu, Ozawa, Shuichi, Nakao, Minoru, Doi, Yoshiko, Kubo, Katsumaro, Kenjo, Masahiko, Nagata, Yasushi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 255
container_issue 3
container_start_page 252
container_title Medical dosimetry : official journal of the American Association of Medical Dosimetrists
container_volume 45
creator Miura, Hideharu
Ozawa, Shuichi
Nakao, Minoru
Doi, Yoshiko
Kubo, Katsumaro
Kenjo, Masahiko
Nagata, Yasushi
description Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor >3 mm in the 3D vector. No displacement >5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.
doi_str_mv 10.1016/j.meddos.2020.01.003
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2356616248</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0958394720300133</els_id><sourcerecordid>2356616248</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</originalsourceid><addsrcrecordid>eNp9kMtuFDEQRS1ERCaBP0DISzbdlNvu1wYJRQlEisSGrC0_atIedbcHPwZllV-PhwmIFSsv6tS9rkPIewY1A9Z92tULWutj3UADNbAagL8iGzb0vBLQNK_JBsZ2qPgo-nNyEeMOAFoB_A055w10XDR8Q56uD2rOKjm_Ur-lbk0YdECVpmrys6VzXh9oyosPdO-j-80F3Advs3HazS490l8uTfSAJhXo4Oe8IJ1cTP4hqIXm6I4JE9J_YxOaaXU_M74lZ1s1R3z38l6S-5vrH1ffqrvvX2-vvtxVRsCQKtWpAYTRndGjNT3XprVKCGBljMICG7VgrVbAhxEHPRox9C2ztrUWew2WX5KPp9zy9VIbk1xcNDjPakWfo2x423Wsa8RQUHFCTfAxBtzKfXCLCo-SgTyqlzt5Ui-P6iUwWdSXtQ8vDVmX8d-lP64L8PkEYLnz4DDIaByuBq0LRZ603v2_4RmgQprX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2356616248</pqid></control><display><type>article</type><title>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</title><source>Elsevier ScienceDirect Journals</source><creator>Miura, Hideharu ; Ozawa, Shuichi ; Nakao, Minoru ; Doi, Yoshiko ; Kubo, Katsumaro ; Kenjo, Masahiko ; Nagata, Yasushi</creator><creatorcontrib>Miura, Hideharu ; Ozawa, Shuichi ; Nakao, Minoru ; Doi, Yoshiko ; Kubo, Katsumaro ; Kenjo, Masahiko ; Nagata, Yasushi</creatorcontrib><description>Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor &gt;3 mm in the 3D vector. No displacement &gt;5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.</description><identifier>ISSN: 0958-3947</identifier><identifier>EISSN: 1873-4022</identifier><identifier>DOI: 10.1016/j.meddos.2020.01.003</identifier><identifier>PMID: 32063423</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Abches system ; Breath-hold ; Interbreath-hold reproducibility ; Lung ; Respiratory management</subject><ispartof>Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2020-01, Vol.45 (3), p.252-255</ispartof><rights>2020 American Association of Medical Dosimetrists</rights><rights>Copyright © 2020 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</citedby><cites>FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</cites><orcidid>0000-0001-5473-4956</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0958394720300133$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32063423$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miura, Hideharu</creatorcontrib><creatorcontrib>Ozawa, Shuichi</creatorcontrib><creatorcontrib>Nakao, Minoru</creatorcontrib><creatorcontrib>Doi, Yoshiko</creatorcontrib><creatorcontrib>Kubo, Katsumaro</creatorcontrib><creatorcontrib>Kenjo, Masahiko</creatorcontrib><creatorcontrib>Nagata, Yasushi</creatorcontrib><title>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</title><title>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</title><addtitle>Med Dosim</addtitle><description>Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor &gt;3 mm in the 3D vector. No displacement &gt;5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.</description><subject>Abches system</subject><subject>Breath-hold</subject><subject>Interbreath-hold reproducibility</subject><subject>Lung</subject><subject>Respiratory management</subject><issn>0958-3947</issn><issn>1873-4022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kMtuFDEQRS1ERCaBP0DISzbdlNvu1wYJRQlEisSGrC0_atIedbcHPwZllV-PhwmIFSsv6tS9rkPIewY1A9Z92tULWutj3UADNbAagL8iGzb0vBLQNK_JBsZ2qPgo-nNyEeMOAFoB_A055w10XDR8Q56uD2rOKjm_Ur-lbk0YdECVpmrys6VzXh9oyosPdO-j-80F3Advs3HazS490l8uTfSAJhXo4Oe8IJ1cTP4hqIXm6I4JE9J_YxOaaXU_M74lZ1s1R3z38l6S-5vrH1ffqrvvX2-vvtxVRsCQKtWpAYTRndGjNT3XprVKCGBljMICG7VgrVbAhxEHPRox9C2ztrUWew2WX5KPp9zy9VIbk1xcNDjPakWfo2x423Wsa8RQUHFCTfAxBtzKfXCLCo-SgTyqlzt5Ui-P6iUwWdSXtQ8vDVmX8d-lP64L8PkEYLnz4DDIaByuBq0LRZ603v2_4RmgQprX</recordid><startdate>20200101</startdate><enddate>20200101</enddate><creator>Miura, Hideharu</creator><creator>Ozawa, Shuichi</creator><creator>Nakao, Minoru</creator><creator>Doi, Yoshiko</creator><creator>Kubo, Katsumaro</creator><creator>Kenjo, Masahiko</creator><creator>Nagata, Yasushi</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5473-4956</orcidid></search><sort><creationdate>20200101</creationdate><title>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</title><author>Miura, Hideharu ; Ozawa, Shuichi ; Nakao, Minoru ; Doi, Yoshiko ; Kubo, Katsumaro ; Kenjo, Masahiko ; Nagata, Yasushi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Abches system</topic><topic>Breath-hold</topic><topic>Interbreath-hold reproducibility</topic><topic>Lung</topic><topic>Respiratory management</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miura, Hideharu</creatorcontrib><creatorcontrib>Ozawa, Shuichi</creatorcontrib><creatorcontrib>Nakao, Minoru</creatorcontrib><creatorcontrib>Doi, Yoshiko</creatorcontrib><creatorcontrib>Kubo, Katsumaro</creatorcontrib><creatorcontrib>Kenjo, Masahiko</creatorcontrib><creatorcontrib>Nagata, Yasushi</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miura, Hideharu</au><au>Ozawa, Shuichi</au><au>Nakao, Minoru</au><au>Doi, Yoshiko</au><au>Kubo, Katsumaro</au><au>Kenjo, Masahiko</au><au>Nagata, Yasushi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</atitle><jtitle>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</jtitle><addtitle>Med Dosim</addtitle><date>2020-01-01</date><risdate>2020</risdate><volume>45</volume><issue>3</issue><spage>252</spage><epage>255</epage><pages>252-255</pages><issn>0958-3947</issn><eissn>1873-4022</eissn><abstract>Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor &gt;3 mm in the 3D vector. No displacement &gt;5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32063423</pmid><doi>10.1016/j.meddos.2020.01.003</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0001-5473-4956</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0958-3947
ispartof Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2020-01, Vol.45 (3), p.252-255
issn 0958-3947
1873-4022
language eng
recordid cdi_proquest_miscellaneous_2356616248
source Elsevier ScienceDirect Journals
subjects Abches system
Breath-hold
Interbreath-hold reproducibility
Lung
Respiratory management
title Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T07%3A57%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20interbreath-hold%20lung%20tumor%20position%20reproducibility%20with%20vector%20volume%20histogram%20using%20the%20breath-hold%20technique&rft.jtitle=Medical%20dosimetry%20:%20official%20journal%20of%20the%20American%20Association%20of%20Medical%20Dosimetrists&rft.au=Miura,%20Hideharu&rft.date=2020-01-01&rft.volume=45&rft.issue=3&rft.spage=252&rft.epage=255&rft.pages=252-255&rft.issn=0958-3947&rft.eissn=1873-4022&rft_id=info:doi/10.1016/j.meddos.2020.01.003&rft_dat=%3Cproquest_cross%3E2356616248%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2356616248&rft_id=info:pmid/32063423&rft_els_id=S0958394720300133&rfr_iscdi=true