Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique
Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14...
Gespeichert in:
Veröffentlicht in: | Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2020-01, Vol.45 (3), p.252-255 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 255 |
---|---|
container_issue | 3 |
container_start_page | 252 |
container_title | Medical dosimetry : official journal of the American Association of Medical Dosimetrists |
container_volume | 45 |
creator | Miura, Hideharu Ozawa, Shuichi Nakao, Minoru Doi, Yoshiko Kubo, Katsumaro Kenjo, Masahiko Nagata, Yasushi |
description | Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor >3 mm in the 3D vector. No displacement >5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method. |
doi_str_mv | 10.1016/j.meddos.2020.01.003 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2356616248</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0958394720300133</els_id><sourcerecordid>2356616248</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</originalsourceid><addsrcrecordid>eNp9kMtuFDEQRS1ERCaBP0DISzbdlNvu1wYJRQlEisSGrC0_atIedbcHPwZllV-PhwmIFSsv6tS9rkPIewY1A9Z92tULWutj3UADNbAagL8iGzb0vBLQNK_JBsZ2qPgo-nNyEeMOAFoB_A055w10XDR8Q56uD2rOKjm_Ur-lbk0YdECVpmrys6VzXh9oyosPdO-j-80F3Advs3HazS490l8uTfSAJhXo4Oe8IJ1cTP4hqIXm6I4JE9J_YxOaaXU_M74lZ1s1R3z38l6S-5vrH1ffqrvvX2-vvtxVRsCQKtWpAYTRndGjNT3XprVKCGBljMICG7VgrVbAhxEHPRox9C2ztrUWew2WX5KPp9zy9VIbk1xcNDjPakWfo2x423Wsa8RQUHFCTfAxBtzKfXCLCo-SgTyqlzt5Ui-P6iUwWdSXtQ8vDVmX8d-lP64L8PkEYLnz4DDIaByuBq0LRZ603v2_4RmgQprX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2356616248</pqid></control><display><type>article</type><title>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</title><source>Elsevier ScienceDirect Journals</source><creator>Miura, Hideharu ; Ozawa, Shuichi ; Nakao, Minoru ; Doi, Yoshiko ; Kubo, Katsumaro ; Kenjo, Masahiko ; Nagata, Yasushi</creator><creatorcontrib>Miura, Hideharu ; Ozawa, Shuichi ; Nakao, Minoru ; Doi, Yoshiko ; Kubo, Katsumaro ; Kenjo, Masahiko ; Nagata, Yasushi</creatorcontrib><description>Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor >3 mm in the 3D vector. No displacement >5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.</description><identifier>ISSN: 0958-3947</identifier><identifier>EISSN: 1873-4022</identifier><identifier>DOI: 10.1016/j.meddos.2020.01.003</identifier><identifier>PMID: 32063423</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Abches system ; Breath-hold ; Interbreath-hold reproducibility ; Lung ; Respiratory management</subject><ispartof>Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2020-01, Vol.45 (3), p.252-255</ispartof><rights>2020 American Association of Medical Dosimetrists</rights><rights>Copyright © 2020 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</citedby><cites>FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</cites><orcidid>0000-0001-5473-4956</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0958394720300133$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32063423$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miura, Hideharu</creatorcontrib><creatorcontrib>Ozawa, Shuichi</creatorcontrib><creatorcontrib>Nakao, Minoru</creatorcontrib><creatorcontrib>Doi, Yoshiko</creatorcontrib><creatorcontrib>Kubo, Katsumaro</creatorcontrib><creatorcontrib>Kenjo, Masahiko</creatorcontrib><creatorcontrib>Nagata, Yasushi</creatorcontrib><title>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</title><title>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</title><addtitle>Med Dosim</addtitle><description>Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor >3 mm in the 3D vector. No displacement >5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.</description><subject>Abches system</subject><subject>Breath-hold</subject><subject>Interbreath-hold reproducibility</subject><subject>Lung</subject><subject>Respiratory management</subject><issn>0958-3947</issn><issn>1873-4022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kMtuFDEQRS1ERCaBP0DISzbdlNvu1wYJRQlEisSGrC0_atIedbcHPwZllV-PhwmIFSsv6tS9rkPIewY1A9Z92tULWutj3UADNbAagL8iGzb0vBLQNK_JBsZ2qPgo-nNyEeMOAFoB_A055w10XDR8Q56uD2rOKjm_Ur-lbk0YdECVpmrys6VzXh9oyosPdO-j-80F3Advs3HazS490l8uTfSAJhXo4Oe8IJ1cTP4hqIXm6I4JE9J_YxOaaXU_M74lZ1s1R3z38l6S-5vrH1ffqrvvX2-vvtxVRsCQKtWpAYTRndGjNT3XprVKCGBljMICG7VgrVbAhxEHPRox9C2ztrUWew2WX5KPp9zy9VIbk1xcNDjPakWfo2x423Wsa8RQUHFCTfAxBtzKfXCLCo-SgTyqlzt5Ui-P6iUwWdSXtQ8vDVmX8d-lP64L8PkEYLnz4DDIaByuBq0LRZ603v2_4RmgQprX</recordid><startdate>20200101</startdate><enddate>20200101</enddate><creator>Miura, Hideharu</creator><creator>Ozawa, Shuichi</creator><creator>Nakao, Minoru</creator><creator>Doi, Yoshiko</creator><creator>Kubo, Katsumaro</creator><creator>Kenjo, Masahiko</creator><creator>Nagata, Yasushi</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5473-4956</orcidid></search><sort><creationdate>20200101</creationdate><title>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</title><author>Miura, Hideharu ; Ozawa, Shuichi ; Nakao, Minoru ; Doi, Yoshiko ; Kubo, Katsumaro ; Kenjo, Masahiko ; Nagata, Yasushi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-a6a804cb6cb9dc73bc5da4401c40e4d019b415ba0389e8b9c48751dd5dde7b0d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Abches system</topic><topic>Breath-hold</topic><topic>Interbreath-hold reproducibility</topic><topic>Lung</topic><topic>Respiratory management</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miura, Hideharu</creatorcontrib><creatorcontrib>Ozawa, Shuichi</creatorcontrib><creatorcontrib>Nakao, Minoru</creatorcontrib><creatorcontrib>Doi, Yoshiko</creatorcontrib><creatorcontrib>Kubo, Katsumaro</creatorcontrib><creatorcontrib>Kenjo, Masahiko</creatorcontrib><creatorcontrib>Nagata, Yasushi</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miura, Hideharu</au><au>Ozawa, Shuichi</au><au>Nakao, Minoru</au><au>Doi, Yoshiko</au><au>Kubo, Katsumaro</au><au>Kenjo, Masahiko</au><au>Nagata, Yasushi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique</atitle><jtitle>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</jtitle><addtitle>Med Dosim</addtitle><date>2020-01-01</date><risdate>2020</risdate><volume>45</volume><issue>3</issue><spage>252</spage><epage>255</epage><pages>252-255</pages><issn>0958-3947</issn><eissn>1873-4022</eissn><abstract>Tumor geometric reproducibility for lung stereotactic body radiotherapy (SBRT) is an important issue in the breath-hold (BH) technique. We investigated the inter-BH reproducibility of the tumor position in expiratory BH using our proposed vector volume histogram (VVH) method. Subjects comprising 14 patients with lung cancer who were treated with lung SBRT under expiratory BH conditions were monitored by the Abches system. Multiple computed tomography (CT) scans were performed to evaluate the inter-BH reproducibility of the tumor position at the expiratory BH in the simulation session. Gross tumor volume was delineated by a physician. Deformable image registration was used to deform the images from the 3 expiratory BH-CTs to the treatment planning expiratory BH-CT. To evaluate the inter-BH reproducibility of the tumor positions, we measured the largest motion extent within the organ of 3 dimensions (left-right, LR; anterior-posterior, AP; cranio-caudal, CC) and a 3D vector using the VVH method. The average and standard deviations of the inter-BH reproducibility of the tumor position in the LR, AP, and CC directions, and the 3D vector were 1.7 ± 0.5, 2.0 ± 0.7, 2.1 ± 0.7, and 2.7 ± 0.7 mm, respectively. Ten patients exhibited inter-BH displacements of the lung tumor >3 mm in the 3D vector. No displacement >5 mm was observed in any direction for all patients. Our study indicated that the inter-BH variation of the tumor position was small for lung cancer patients, using the Abches system and the VVH method.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32063423</pmid><doi>10.1016/j.meddos.2020.01.003</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0001-5473-4956</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0958-3947 |
ispartof | Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2020-01, Vol.45 (3), p.252-255 |
issn | 0958-3947 1873-4022 |
language | eng |
recordid | cdi_proquest_miscellaneous_2356616248 |
source | Elsevier ScienceDirect Journals |
subjects | Abches system Breath-hold Interbreath-hold reproducibility Lung Respiratory management |
title | Evaluation of interbreath-hold lung tumor position reproducibility with vector volume histogram using the breath-hold technique |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T07%3A57%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20interbreath-hold%20lung%20tumor%20position%20reproducibility%20with%20vector%20volume%20histogram%20using%20the%20breath-hold%20technique&rft.jtitle=Medical%20dosimetry%20:%20official%20journal%20of%20the%20American%20Association%20of%20Medical%20Dosimetrists&rft.au=Miura,%20Hideharu&rft.date=2020-01-01&rft.volume=45&rft.issue=3&rft.spage=252&rft.epage=255&rft.pages=252-255&rft.issn=0958-3947&rft.eissn=1873-4022&rft_id=info:doi/10.1016/j.meddos.2020.01.003&rft_dat=%3Cproquest_cross%3E2356616248%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2356616248&rft_id=info:pmid/32063423&rft_els_id=S0958394720300133&rfr_iscdi=true |