Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments Correlate Better With Legacy Measures in Knee Cartilage Patients at Postoperative Than at Preoperative Assessment

To define the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF), Pain Interference (PI), and Depression computer adaptive tests (CATs) in patients undergoing knee cartilage surgical procedures. The PROMIS PF, PI, and Depression CA...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arthroscopy 2020-05, Vol.36 (5), p.1419-1428
Hauptverfasser: Nwachukwu, Benedict U., Beletsky, Alexander, Naveen, Neal, Southworth, Taylor M., Okoroha, Kelechi R., Forsythe, Brian, Verma, Nikhil, Yanke, Adam, Cole, Brian J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1428
container_issue 5
container_start_page 1419
container_title Arthroscopy
container_volume 36
creator Nwachukwu, Benedict U.
Beletsky, Alexander
Naveen, Neal
Southworth, Taylor M.
Okoroha, Kelechi R.
Forsythe, Brian
Verma, Nikhil
Yanke, Adam
Cole, Brian J.
description To define the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF), Pain Interference (PI), and Depression computer adaptive tests (CATs) in patients undergoing knee cartilage surgical procedures. The PROMIS PF, PI, and Depression CATs were administered preoperatively and at 6 months alongside legacy knee patient-reported outcome measures (PROMs) in patients undergoing knee cartilage surgical procedures. Statistical analysis consisted of the time to completion, psychometric analysis for correlative strengths, absolute and relative floor and ceiling effects, and Cohen effect size. Our study included 250 patients (57.2% male patients), averaging 1.87, 1.53, and 1.91 minutes for completion of the PF, PI, and Depression CATs, respectively. Preoperatively, the PROMIS PF and PI CATs showed wide ranges of correlation coefficients with respect to function (r = 0.14-0.72 and r = 0.29-0.77, respectively) and health-related quality-of-life PROMs (r = 0.64-0.70). At 6 months, the PROMIS PF CAT (r = 0.82-0.93) and PI CAT (r = 0.77-0.93) both exhibited excellent correlations with respect to legacy function and health-related quality-of-life PROMs except for the Marx Activity Rating Scale (r = 0.36-0.44). None of the PROMIS instruments exhibited any significant floor or ceiling effects. The PROMIS PF, PI, and Depression CATs performed better with respect to legacy PROMs in the postoperative period than the preoperative period. In addition, the PROMIS PF and PI measures performed best with respect to the International Knee Documentation Committee questionnaire, and no floor or ceiling effects were identified for the PROMIS instruments. The PROMIS instruments may be more suited to track outcomes postoperatively than to establish preoperative baselines in cartilage surgery patients. Level IV, retrospective case series.
doi_str_mv 10.1016/j.arthro.2020.01.036
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2352633095</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0749806320301183</els_id><sourcerecordid>2352633095</sourcerecordid><originalsourceid>FETCH-LOGICAL-c362t-1075d38ce3c4e16a62406f51d0245715db9fc6d3564101c9a1264745101ad683</originalsourceid><addsrcrecordid>eNp9UU1vEzEQtRCIhsI_QMjHctjFX-tNLkgl4iMiVaI2EkfL9c42jnbXweOtlF_HX8MhKdw4WX7zZt7Me4S85azkjOsPu9LGtI2hFEywkvGSSf2MTHgldCGF5M_JhNVqVkyZlhfkFeKOMSblVL4kF1IwWfFaTcivtU0ehlTcwj7EBA1djcmFHpDegMUxQp-rdDG0IfaZGgZ6d8AEPb1a365uFnfvcw1THI80pPMQI3Q2Af0EKUGkP3za0iU8WHd4GojUD_T7AEDn-QLf2Qeg5y2Q2kTXAVPYQ8zQI9DN1g5_0Aj_wGtEQDxKviYvWtshvDm_l2Tz5fNm_q1Yrr4u5tfLwkktUsFZXTVy6kA6BVxbLRTTbcUbJlRV86q5n7VON7LSKpvrZpYLrWpV5Y9t9FRekqvT2H0MP0fAZHqPDrrODhBGNEJm26VksypT1YnqYkCM0Jp99L2NB8OZOSZnduaUnDkmZxg3Obnc9u6sMN730PxteooqEz6eCJDPfPQQDbrsmYPGR3DJNMH_X-E3kgqu4Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2352633095</pqid></control><display><type>article</type><title>Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments Correlate Better With Legacy Measures in Knee Cartilage Patients at Postoperative Than at Preoperative Assessment</title><source>Elsevier ScienceDirect Journals</source><creator>Nwachukwu, Benedict U. ; Beletsky, Alexander ; Naveen, Neal ; Southworth, Taylor M. ; Okoroha, Kelechi R. ; Forsythe, Brian ; Verma, Nikhil ; Yanke, Adam ; Cole, Brian J.</creator><creatorcontrib>Nwachukwu, Benedict U. ; Beletsky, Alexander ; Naveen, Neal ; Southworth, Taylor M. ; Okoroha, Kelechi R. ; Forsythe, Brian ; Verma, Nikhil ; Yanke, Adam ; Cole, Brian J.</creatorcontrib><description>To define the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF), Pain Interference (PI), and Depression computer adaptive tests (CATs) in patients undergoing knee cartilage surgical procedures. The PROMIS PF, PI, and Depression CATs were administered preoperatively and at 6 months alongside legacy knee patient-reported outcome measures (PROMs) in patients undergoing knee cartilage surgical procedures. Statistical analysis consisted of the time to completion, psychometric analysis for correlative strengths, absolute and relative floor and ceiling effects, and Cohen effect size. Our study included 250 patients (57.2% male patients), averaging 1.87, 1.53, and 1.91 minutes for completion of the PF, PI, and Depression CATs, respectively. Preoperatively, the PROMIS PF and PI CATs showed wide ranges of correlation coefficients with respect to function (r = 0.14-0.72 and r = 0.29-0.77, respectively) and health-related quality-of-life PROMs (r = 0.64-0.70). At 6 months, the PROMIS PF CAT (r = 0.82-0.93) and PI CAT (r = 0.77-0.93) both exhibited excellent correlations with respect to legacy function and health-related quality-of-life PROMs except for the Marx Activity Rating Scale (r = 0.36-0.44). None of the PROMIS instruments exhibited any significant floor or ceiling effects. The PROMIS PF, PI, and Depression CATs performed better with respect to legacy PROMs in the postoperative period than the preoperative period. In addition, the PROMIS PF and PI measures performed best with respect to the International Knee Documentation Committee questionnaire, and no floor or ceiling effects were identified for the PROMIS instruments. The PROMIS instruments may be more suited to track outcomes postoperatively than to establish preoperative baselines in cartilage surgery patients. Level IV, retrospective case series.</description><identifier>ISSN: 0749-8063</identifier><identifier>EISSN: 1526-3231</identifier><identifier>DOI: 10.1016/j.arthro.2020.01.036</identifier><identifier>PMID: 32035174</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><ispartof>Arthroscopy, 2020-05, Vol.36 (5), p.1419-1428</ispartof><rights>2020 Arthroscopy Association of North America</rights><rights>Copyright © 2020 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c362t-1075d38ce3c4e16a62406f51d0245715db9fc6d3564101c9a1264745101ad683</citedby><cites>FETCH-LOGICAL-c362t-1075d38ce3c4e16a62406f51d0245715db9fc6d3564101c9a1264745101ad683</cites><orcidid>0000-0003-0519-4222 ; 0000-0001-9875-2769 ; 0000-0002-9601-4217 ; 0000-0002-4006-2113</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0749806320301183$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32035174$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nwachukwu, Benedict U.</creatorcontrib><creatorcontrib>Beletsky, Alexander</creatorcontrib><creatorcontrib>Naveen, Neal</creatorcontrib><creatorcontrib>Southworth, Taylor M.</creatorcontrib><creatorcontrib>Okoroha, Kelechi R.</creatorcontrib><creatorcontrib>Forsythe, Brian</creatorcontrib><creatorcontrib>Verma, Nikhil</creatorcontrib><creatorcontrib>Yanke, Adam</creatorcontrib><creatorcontrib>Cole, Brian J.</creatorcontrib><title>Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments Correlate Better With Legacy Measures in Knee Cartilage Patients at Postoperative Than at Preoperative Assessment</title><title>Arthroscopy</title><addtitle>Arthroscopy</addtitle><description>To define the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF), Pain Interference (PI), and Depression computer adaptive tests (CATs) in patients undergoing knee cartilage surgical procedures. The PROMIS PF, PI, and Depression CATs were administered preoperatively and at 6 months alongside legacy knee patient-reported outcome measures (PROMs) in patients undergoing knee cartilage surgical procedures. Statistical analysis consisted of the time to completion, psychometric analysis for correlative strengths, absolute and relative floor and ceiling effects, and Cohen effect size. Our study included 250 patients (57.2% male patients), averaging 1.87, 1.53, and 1.91 minutes for completion of the PF, PI, and Depression CATs, respectively. Preoperatively, the PROMIS PF and PI CATs showed wide ranges of correlation coefficients with respect to function (r = 0.14-0.72 and r = 0.29-0.77, respectively) and health-related quality-of-life PROMs (r = 0.64-0.70). At 6 months, the PROMIS PF CAT (r = 0.82-0.93) and PI CAT (r = 0.77-0.93) both exhibited excellent correlations with respect to legacy function and health-related quality-of-life PROMs except for the Marx Activity Rating Scale (r = 0.36-0.44). None of the PROMIS instruments exhibited any significant floor or ceiling effects. The PROMIS PF, PI, and Depression CATs performed better with respect to legacy PROMs in the postoperative period than the preoperative period. In addition, the PROMIS PF and PI measures performed best with respect to the International Knee Documentation Committee questionnaire, and no floor or ceiling effects were identified for the PROMIS instruments. The PROMIS instruments may be more suited to track outcomes postoperatively than to establish preoperative baselines in cartilage surgery patients. Level IV, retrospective case series.</description><issn>0749-8063</issn><issn>1526-3231</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9UU1vEzEQtRCIhsI_QMjHctjFX-tNLkgl4iMiVaI2EkfL9c42jnbXweOtlF_HX8MhKdw4WX7zZt7Me4S85azkjOsPu9LGtI2hFEywkvGSSf2MTHgldCGF5M_JhNVqVkyZlhfkFeKOMSblVL4kF1IwWfFaTcivtU0ehlTcwj7EBA1djcmFHpDegMUxQp-rdDG0IfaZGgZ6d8AEPb1a365uFnfvcw1THI80pPMQI3Q2Af0EKUGkP3za0iU8WHd4GojUD_T7AEDn-QLf2Qeg5y2Q2kTXAVPYQ8zQI9DN1g5_0Aj_wGtEQDxKviYvWtshvDm_l2Tz5fNm_q1Yrr4u5tfLwkktUsFZXTVy6kA6BVxbLRTTbcUbJlRV86q5n7VON7LSKpvrZpYLrWpV5Y9t9FRekqvT2H0MP0fAZHqPDrrODhBGNEJm26VksypT1YnqYkCM0Jp99L2NB8OZOSZnduaUnDkmZxg3Obnc9u6sMN730PxteooqEz6eCJDPfPQQDbrsmYPGR3DJNMH_X-E3kgqu4Q</recordid><startdate>202005</startdate><enddate>202005</enddate><creator>Nwachukwu, Benedict U.</creator><creator>Beletsky, Alexander</creator><creator>Naveen, Neal</creator><creator>Southworth, Taylor M.</creator><creator>Okoroha, Kelechi R.</creator><creator>Forsythe, Brian</creator><creator>Verma, Nikhil</creator><creator>Yanke, Adam</creator><creator>Cole, Brian J.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0519-4222</orcidid><orcidid>https://orcid.org/0000-0001-9875-2769</orcidid><orcidid>https://orcid.org/0000-0002-9601-4217</orcidid><orcidid>https://orcid.org/0000-0002-4006-2113</orcidid></search><sort><creationdate>202005</creationdate><title>Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments Correlate Better With Legacy Measures in Knee Cartilage Patients at Postoperative Than at Preoperative Assessment</title><author>Nwachukwu, Benedict U. ; Beletsky, Alexander ; Naveen, Neal ; Southworth, Taylor M. ; Okoroha, Kelechi R. ; Forsythe, Brian ; Verma, Nikhil ; Yanke, Adam ; Cole, Brian J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c362t-1075d38ce3c4e16a62406f51d0245715db9fc6d3564101c9a1264745101ad683</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nwachukwu, Benedict U.</creatorcontrib><creatorcontrib>Beletsky, Alexander</creatorcontrib><creatorcontrib>Naveen, Neal</creatorcontrib><creatorcontrib>Southworth, Taylor M.</creatorcontrib><creatorcontrib>Okoroha, Kelechi R.</creatorcontrib><creatorcontrib>Forsythe, Brian</creatorcontrib><creatorcontrib>Verma, Nikhil</creatorcontrib><creatorcontrib>Yanke, Adam</creatorcontrib><creatorcontrib>Cole, Brian J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Arthroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nwachukwu, Benedict U.</au><au>Beletsky, Alexander</au><au>Naveen, Neal</au><au>Southworth, Taylor M.</au><au>Okoroha, Kelechi R.</au><au>Forsythe, Brian</au><au>Verma, Nikhil</au><au>Yanke, Adam</au><au>Cole, Brian J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments Correlate Better With Legacy Measures in Knee Cartilage Patients at Postoperative Than at Preoperative Assessment</atitle><jtitle>Arthroscopy</jtitle><addtitle>Arthroscopy</addtitle><date>2020-05</date><risdate>2020</risdate><volume>36</volume><issue>5</issue><spage>1419</spage><epage>1428</epage><pages>1419-1428</pages><issn>0749-8063</issn><eissn>1526-3231</eissn><abstract>To define the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF), Pain Interference (PI), and Depression computer adaptive tests (CATs) in patients undergoing knee cartilage surgical procedures. The PROMIS PF, PI, and Depression CATs were administered preoperatively and at 6 months alongside legacy knee patient-reported outcome measures (PROMs) in patients undergoing knee cartilage surgical procedures. Statistical analysis consisted of the time to completion, psychometric analysis for correlative strengths, absolute and relative floor and ceiling effects, and Cohen effect size. Our study included 250 patients (57.2% male patients), averaging 1.87, 1.53, and 1.91 minutes for completion of the PF, PI, and Depression CATs, respectively. Preoperatively, the PROMIS PF and PI CATs showed wide ranges of correlation coefficients with respect to function (r = 0.14-0.72 and r = 0.29-0.77, respectively) and health-related quality-of-life PROMs (r = 0.64-0.70). At 6 months, the PROMIS PF CAT (r = 0.82-0.93) and PI CAT (r = 0.77-0.93) both exhibited excellent correlations with respect to legacy function and health-related quality-of-life PROMs except for the Marx Activity Rating Scale (r = 0.36-0.44). None of the PROMIS instruments exhibited any significant floor or ceiling effects. The PROMIS PF, PI, and Depression CATs performed better with respect to legacy PROMs in the postoperative period than the preoperative period. In addition, the PROMIS PF and PI measures performed best with respect to the International Knee Documentation Committee questionnaire, and no floor or ceiling effects were identified for the PROMIS instruments. The PROMIS instruments may be more suited to track outcomes postoperatively than to establish preoperative baselines in cartilage surgery patients. Level IV, retrospective case series.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>32035174</pmid><doi>10.1016/j.arthro.2020.01.036</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0003-0519-4222</orcidid><orcidid>https://orcid.org/0000-0001-9875-2769</orcidid><orcidid>https://orcid.org/0000-0002-9601-4217</orcidid><orcidid>https://orcid.org/0000-0002-4006-2113</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0749-8063
ispartof Arthroscopy, 2020-05, Vol.36 (5), p.1419-1428
issn 0749-8063
1526-3231
language eng
recordid cdi_proquest_miscellaneous_2352633095
source Elsevier ScienceDirect Journals
title Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments Correlate Better With Legacy Measures in Knee Cartilage Patients at Postoperative Than at Preoperative Assessment
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T21%3A20%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Patient-Reported%20Outcomes%20Measurement%20Information%20System%20(PROMIS)%20Instruments%20Correlate%20Better%20With%20Legacy%20Measures%20in%20Knee%20Cartilage%20Patients%20at%20Postoperative%20Than%20at%20Preoperative%20Assessment&rft.jtitle=Arthroscopy&rft.au=Nwachukwu,%20Benedict%20U.&rft.date=2020-05&rft.volume=36&rft.issue=5&rft.spage=1419&rft.epage=1428&rft.pages=1419-1428&rft.issn=0749-8063&rft.eissn=1526-3231&rft_id=info:doi/10.1016/j.arthro.2020.01.036&rft_dat=%3Cproquest_cross%3E2352633095%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2352633095&rft_id=info:pmid/32035174&rft_els_id=S0749806320301183&rfr_iscdi=true