Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study

The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular li...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 2020-05, Vol.35 (5), p.1290-1296
Hauptverfasser: Shin, Won Chul, Moon, Nam Hoon, Jeon, Se Bin, Suh, Kuen Tak
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1296
container_issue 5
container_start_page 1290
container_title The Journal of arthroplasty
container_volume 35
creator Shin, Won Chul
Moon, Nam Hoon
Jeon, Se Bin
Suh, Kuen Tak
description The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA). In this retrospective cohort study, we evaluated 112 primary THAs performed by a single experienced arthroplasty surgeon at our institution between March 2000 and December 2003. Patients were classified based on the type of acetabular liner used: standard or elevated-rim liner. For evaluation of surgical outcomes, the following data were collected: acetabular cup position (anteversion and inclination), wear rate (linear and volumetric), presence of osteolysis, history of reoperation (all-cause and wear-related), complications (deep joint infection, dislocation, and periprosthetic fracture), and Harris hip score at last follow-up. Linear and volumetric wear rates were 0.028 mm/y (0.000-0.145 mm/y) and 11.641 mm3/y (0.000-70.000 mm3/y) in the standard group and 0.026 mm/y (0.000-0.094mm/y) and 9.706 mm3/y (0.000-33.000 mm3/y) in the elevated-rim group, respectively. These rates were not significantly different between groups. One case of osteolysis was confirmed in the standard group, whereas no osteolysis was observed in the elevated-rim group. We suggest that elevated-rim highly cross-linked polyethylene acetabular liners might be a good implant option that can be used safely.
doi_str_mv 10.1016/j.arth.2019.12.026
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2346301335</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540319311751</els_id><sourcerecordid>2346301335</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-87d32382faf5b38a6c595b0f5dc120cd5a3fa09487723069b7560a6a8691c0183</originalsourceid><addsrcrecordid>eNp9kcFuEzEURUcIREPhB1ggL1kwwR7HkxnEJozaBimoVdMKsbIc-03i4LGntifV_C2fUkcpLFm9he-9z--eLHtP8JRgUn7eT4WPu2mBST0lxRQX5YtsQhgt8mqGy5fZBFcVzdkM07PsTQh7jAlhbPY6O6Okrigr2ST707iuF14HZ5Fr0XrwWy2FQddDlK6DgL5BfASwaB2FVcIrlAa6MHAQEVR-qzu01NudGVHjXQj5StvfoNCNMyPE3WjAAlpIiGIzGOFRegYfkLboxutO-BHduZjWLXWPFukY73ojQhzRTx136Ie2uhs6RFj-C5L70hnjHvP7_gtaa7s1kDdgI_hP6BZiWt-DjPoAqHE752P68qDGt9mrVpgA757neXZ_eXHXLPPV9dX3ZrHKZSoi5tVc0YJWRStatqGVKCWr2Qa3TElSYKmYoK3A9ayazwuKy3ozZyUWpajKmkhMKnqefTzl9t49DBAi73SQYIyw4IbACzorKSaUsiQtTlJ5rMxDy_tTGZxgfiTL9_xIlh_JclLwRDaZPjznD5sO1D_LX5RJ8PUkgHTlQYPnQWqwEpT2qReunP5f_hPArrhx</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2346301335</pqid></control><display><type>article</type><title>Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Shin, Won Chul ; Moon, Nam Hoon ; Jeon, Se Bin ; Suh, Kuen Tak</creator><creatorcontrib>Shin, Won Chul ; Moon, Nam Hoon ; Jeon, Se Bin ; Suh, Kuen Tak</creatorcontrib><description>The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA). In this retrospective cohort study, we evaluated 112 primary THAs performed by a single experienced arthroplasty surgeon at our institution between March 2000 and December 2003. Patients were classified based on the type of acetabular liner used: standard or elevated-rim liner. For evaluation of surgical outcomes, the following data were collected: acetabular cup position (anteversion and inclination), wear rate (linear and volumetric), presence of osteolysis, history of reoperation (all-cause and wear-related), complications (deep joint infection, dislocation, and periprosthetic fracture), and Harris hip score at last follow-up. Linear and volumetric wear rates were 0.028 mm/y (0.000-0.145 mm/y) and 11.641 mm3/y (0.000-70.000 mm3/y) in the standard group and 0.026 mm/y (0.000-0.094mm/y) and 9.706 mm3/y (0.000-33.000 mm3/y) in the elevated-rim group, respectively. These rates were not significantly different between groups. One case of osteolysis was confirmed in the standard group, whereas no osteolysis was observed in the elevated-rim group. We suggest that elevated-rim highly cross-linked polyethylene acetabular liners might be a good implant option that can be used safely.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2019.12.026</identifier><identifier>PMID: 31983565</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>acetabular liner ; Arthroplasty, Replacement, Hip - adverse effects ; elevated-rim ; Follow-Up Studies ; highly cross-linked polyethylene ; Hip Prosthesis ; Humans ; liner wear ; Osteolysis - epidemiology ; Osteolysis - etiology ; Polyethylene ; Prosthesis Design ; Prosthesis Failure ; Reference Standards ; Retrospective Studies ; total hip arthroplasty ; Treatment Outcome</subject><ispartof>The Journal of arthroplasty, 2020-05, Vol.35 (5), p.1290-1296</ispartof><rights>2019 Elsevier Inc.</rights><rights>Copyright © 2019 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-87d32382faf5b38a6c595b0f5dc120cd5a3fa09487723069b7560a6a8691c0183</citedby><cites>FETCH-LOGICAL-c356t-87d32382faf5b38a6c595b0f5dc120cd5a3fa09487723069b7560a6a8691c0183</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0883540319311751$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31983565$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shin, Won Chul</creatorcontrib><creatorcontrib>Moon, Nam Hoon</creatorcontrib><creatorcontrib>Jeon, Se Bin</creatorcontrib><creatorcontrib>Suh, Kuen Tak</creatorcontrib><title>Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA). In this retrospective cohort study, we evaluated 112 primary THAs performed by a single experienced arthroplasty surgeon at our institution between March 2000 and December 2003. Patients were classified based on the type of acetabular liner used: standard or elevated-rim liner. For evaluation of surgical outcomes, the following data were collected: acetabular cup position (anteversion and inclination), wear rate (linear and volumetric), presence of osteolysis, history of reoperation (all-cause and wear-related), complications (deep joint infection, dislocation, and periprosthetic fracture), and Harris hip score at last follow-up. Linear and volumetric wear rates were 0.028 mm/y (0.000-0.145 mm/y) and 11.641 mm3/y (0.000-70.000 mm3/y) in the standard group and 0.026 mm/y (0.000-0.094mm/y) and 9.706 mm3/y (0.000-33.000 mm3/y) in the elevated-rim group, respectively. These rates were not significantly different between groups. One case of osteolysis was confirmed in the standard group, whereas no osteolysis was observed in the elevated-rim group. We suggest that elevated-rim highly cross-linked polyethylene acetabular liners might be a good implant option that can be used safely.</description><subject>acetabular liner</subject><subject>Arthroplasty, Replacement, Hip - adverse effects</subject><subject>elevated-rim</subject><subject>Follow-Up Studies</subject><subject>highly cross-linked polyethylene</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>liner wear</subject><subject>Osteolysis - epidemiology</subject><subject>Osteolysis - etiology</subject><subject>Polyethylene</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Reference Standards</subject><subject>Retrospective Studies</subject><subject>total hip arthroplasty</subject><subject>Treatment Outcome</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kcFuEzEURUcIREPhB1ggL1kwwR7HkxnEJozaBimoVdMKsbIc-03i4LGntifV_C2fUkcpLFm9he-9z--eLHtP8JRgUn7eT4WPu2mBST0lxRQX5YtsQhgt8mqGy5fZBFcVzdkM07PsTQh7jAlhbPY6O6Okrigr2ST707iuF14HZ5Fr0XrwWy2FQddDlK6DgL5BfASwaB2FVcIrlAa6MHAQEVR-qzu01NudGVHjXQj5StvfoNCNMyPE3WjAAlpIiGIzGOFRegYfkLboxutO-BHduZjWLXWPFukY73ojQhzRTx136Ie2uhs6RFj-C5L70hnjHvP7_gtaa7s1kDdgI_hP6BZiWt-DjPoAqHE752P68qDGt9mrVpgA757neXZ_eXHXLPPV9dX3ZrHKZSoi5tVc0YJWRStatqGVKCWr2Qa3TElSYKmYoK3A9ayazwuKy3ozZyUWpajKmkhMKnqefTzl9t49DBAi73SQYIyw4IbACzorKSaUsiQtTlJ5rMxDy_tTGZxgfiTL9_xIlh_JclLwRDaZPjznD5sO1D_LX5RJ8PUkgHTlQYPnQWqwEpT2qReunP5f_hPArrhx</recordid><startdate>202005</startdate><enddate>202005</enddate><creator>Shin, Won Chul</creator><creator>Moon, Nam Hoon</creator><creator>Jeon, Se Bin</creator><creator>Suh, Kuen Tak</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202005</creationdate><title>Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study</title><author>Shin, Won Chul ; Moon, Nam Hoon ; Jeon, Se Bin ; Suh, Kuen Tak</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-87d32382faf5b38a6c595b0f5dc120cd5a3fa09487723069b7560a6a8691c0183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>acetabular liner</topic><topic>Arthroplasty, Replacement, Hip - adverse effects</topic><topic>elevated-rim</topic><topic>Follow-Up Studies</topic><topic>highly cross-linked polyethylene</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>liner wear</topic><topic>Osteolysis - epidemiology</topic><topic>Osteolysis - etiology</topic><topic>Polyethylene</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Reference Standards</topic><topic>Retrospective Studies</topic><topic>total hip arthroplasty</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shin, Won Chul</creatorcontrib><creatorcontrib>Moon, Nam Hoon</creatorcontrib><creatorcontrib>Jeon, Se Bin</creatorcontrib><creatorcontrib>Suh, Kuen Tak</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shin, Won Chul</au><au>Moon, Nam Hoon</au><au>Jeon, Se Bin</au><au>Suh, Kuen Tak</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>2020-05</date><risdate>2020</risdate><volume>35</volume><issue>5</issue><spage>1290</spage><epage>1296</epage><pages>1290-1296</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA). In this retrospective cohort study, we evaluated 112 primary THAs performed by a single experienced arthroplasty surgeon at our institution between March 2000 and December 2003. Patients were classified based on the type of acetabular liner used: standard or elevated-rim liner. For evaluation of surgical outcomes, the following data were collected: acetabular cup position (anteversion and inclination), wear rate (linear and volumetric), presence of osteolysis, history of reoperation (all-cause and wear-related), complications (deep joint infection, dislocation, and periprosthetic fracture), and Harris hip score at last follow-up. Linear and volumetric wear rates were 0.028 mm/y (0.000-0.145 mm/y) and 11.641 mm3/y (0.000-70.000 mm3/y) in the standard group and 0.026 mm/y (0.000-0.094mm/y) and 9.706 mm3/y (0.000-33.000 mm3/y) in the elevated-rim group, respectively. These rates were not significantly different between groups. One case of osteolysis was confirmed in the standard group, whereas no osteolysis was observed in the elevated-rim group. We suggest that elevated-rim highly cross-linked polyethylene acetabular liners might be a good implant option that can be used safely.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>31983565</pmid><doi>10.1016/j.arth.2019.12.026</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 2020-05, Vol.35 (5), p.1290-1296
issn 0883-5403
1532-8406
language eng
recordid cdi_proquest_miscellaneous_2346301335
source MEDLINE; Elsevier ScienceDirect Journals
subjects acetabular liner
Arthroplasty, Replacement, Hip - adverse effects
elevated-rim
Follow-Up Studies
highly cross-linked polyethylene
Hip Prosthesis
Humans
liner wear
Osteolysis - epidemiology
Osteolysis - etiology
Polyethylene
Prosthesis Design
Prosthesis Failure
Reference Standards
Retrospective Studies
total hip arthroplasty
Treatment Outcome
title Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T23%3A39%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Surgical%20Outcomes%20Between%20Standard%20and%20Elevated-Rim%20Highly%20Cross-Linked%20Polyethylene%20Acetabular%20Liners%20in%20Primary%20Total%20Hip%20Arthroplasty%20With%20Minimum%2015-Year%20Follow-Up:%20Single-Center,%20Retrospective%20Cohort%20Study&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Shin,%20Won%20Chul&rft.date=2020-05&rft.volume=35&rft.issue=5&rft.spage=1290&rft.epage=1296&rft.pages=1290-1296&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2019.12.026&rft_dat=%3Cproquest_cross%3E2346301335%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2346301335&rft_id=info:pmid/31983565&rft_els_id=S0883540319311751&rfr_iscdi=true