Direct Puncture Tunnel Method for Establishing the Retroperitoneal Cavity: Anatomic Confirmation and Clinical Experience

The feasibility and safety of the direct puncture tunnel method to establish the retroperitoneal cavity was assessed by CT and clinical experience. Ten patients who underwent retroperitoneoscopic procedure were scanned by CT in the lateral decubitus position. The distance between the lumbar fascia a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endourology 2020-03, Vol.34 (3), p.298-303
Hauptverfasser: Lan, Jianhua, Liao, Banghua, Ai, Jianzhong, Zhou, Liang, Wang, Kunjie
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 303
container_issue 3
container_start_page 298
container_title Journal of endourology
container_volume 34
creator Lan, Jianhua
Liao, Banghua
Ai, Jianzhong
Zhou, Liang
Wang, Kunjie
description The feasibility and safety of the direct puncture tunnel method to establish the retroperitoneal cavity was assessed by CT and clinical experience. Ten patients who underwent retroperitoneoscopic procedure were scanned by CT in the lateral decubitus position. The distance between the lumbar fascia and psoas major muscle (L-P distance) on the puncture line was measured. The angle between the puncture line and the posterior colon margin (P-C angle) was also measured. In total, 292 patients who underwent retroperitoneoscopic procedure were used to establish the retroperitoneal cavity using the direct puncture tunnel method, and complications in these patients were evaluated. The average L-P distance was 25.0 mm (left side) and 25.5 mm (right side) in the lateral decubitus position. The average P-C angle was 26.8° (left side) and 29.7° (right side). The retroperitoneal cavity was well established in all 292 patients, and no visceral or blood vessel injury occurred. CT scans in the lateral recumbent position indicate that there are no visceral and large blood vessels on the puncture path. The scans also provide a window for inserting the first trocar blindly into the retroperitoneum. A high success rate and low complication rate were observed clinically for the direct puncture tunnel method. We consider the direct puncture tunnel method to be a simple, effective, and safe way to establish the retroperitoneal cavity.
doi_str_mv 10.1089/end.2019.0699
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2344278438</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2344278438</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-3c0621e3f593c1050c5b589a55016222a32a095ef7a580d23c14748fd82f34233</originalsourceid><addsrcrecordid>eNo90DtPwzAQwHELgWgpjKzII0uKH3ESs1WhPKQiECoSW-Q6F2qU2MV2UPvtScVjuuF-d8MfoXNKppQU8gpsPWWEyinJpDxAYypEnkhC3g7ReNizJM8lGaGTED4IoTyj_BiNOJU5F0U2Rtsb40FH_NxbHXsPeNlbCy1-hLh2NW6cx_MQ1ao1YW3sO45rwC8QvduAN9FZUC0u1ZeJu2s8syq6zmhcOtsY36lonMXK1rhsjTV6oPPt_g6shlN01Kg2wNnvnKDX2_myvE8WT3cP5WyRaM5ZTLgmGaPAGyG5pkQQLVaikEoIQjPGmOJMESmgyZUoSM0GlOZp0dQFa3jKOJ-gy5-_G-8-ewix6kzQ0LbKgutDxXiasrxIeTHQ5Idq70Lw0FQbbzrldxUl1T52NcSu9rGrfezBX_y-7lcd1P_6ry7_BuNmezA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2344278438</pqid></control><display><type>article</type><title>Direct Puncture Tunnel Method for Establishing the Retroperitoneal Cavity: Anatomic Confirmation and Clinical Experience</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Lan, Jianhua ; Liao, Banghua ; Ai, Jianzhong ; Zhou, Liang ; Wang, Kunjie</creator><creatorcontrib>Lan, Jianhua ; Liao, Banghua ; Ai, Jianzhong ; Zhou, Liang ; Wang, Kunjie</creatorcontrib><description>The feasibility and safety of the direct puncture tunnel method to establish the retroperitoneal cavity was assessed by CT and clinical experience. Ten patients who underwent retroperitoneoscopic procedure were scanned by CT in the lateral decubitus position. The distance between the lumbar fascia and psoas major muscle (L-P distance) on the puncture line was measured. The angle between the puncture line and the posterior colon margin (P-C angle) was also measured. In total, 292 patients who underwent retroperitoneoscopic procedure were used to establish the retroperitoneal cavity using the direct puncture tunnel method, and complications in these patients were evaluated. The average L-P distance was 25.0 mm (left side) and 25.5 mm (right side) in the lateral decubitus position. The average P-C angle was 26.8° (left side) and 29.7° (right side). The retroperitoneal cavity was well established in all 292 patients, and no visceral or blood vessel injury occurred. CT scans in the lateral recumbent position indicate that there are no visceral and large blood vessels on the puncture path. The scans also provide a window for inserting the first trocar blindly into the retroperitoneum. A high success rate and low complication rate were observed clinically for the direct puncture tunnel method. We consider the direct puncture tunnel method to be a simple, effective, and safe way to establish the retroperitoneal cavity.</description><identifier>ISSN: 0892-7790</identifier><identifier>EISSN: 1557-900X</identifier><identifier>DOI: 10.1089/end.2019.0699</identifier><identifier>PMID: 31973586</identifier><language>eng</language><publisher>United States</publisher><subject>Humans ; Psoas Muscles ; Punctures ; Retroperitoneal Space - diagnostic imaging ; Retroperitoneal Space - surgery ; Tomography, X-Ray Computed</subject><ispartof>Journal of endourology, 2020-03, Vol.34 (3), p.298-303</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-3c0621e3f593c1050c5b589a55016222a32a095ef7a580d23c14748fd82f34233</citedby><cites>FETCH-LOGICAL-c332t-3c0621e3f593c1050c5b589a55016222a32a095ef7a580d23c14748fd82f34233</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27907,27908</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31973586$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lan, Jianhua</creatorcontrib><creatorcontrib>Liao, Banghua</creatorcontrib><creatorcontrib>Ai, Jianzhong</creatorcontrib><creatorcontrib>Zhou, Liang</creatorcontrib><creatorcontrib>Wang, Kunjie</creatorcontrib><title>Direct Puncture Tunnel Method for Establishing the Retroperitoneal Cavity: Anatomic Confirmation and Clinical Experience</title><title>Journal of endourology</title><addtitle>J Endourol</addtitle><description>The feasibility and safety of the direct puncture tunnel method to establish the retroperitoneal cavity was assessed by CT and clinical experience. Ten patients who underwent retroperitoneoscopic procedure were scanned by CT in the lateral decubitus position. The distance between the lumbar fascia and psoas major muscle (L-P distance) on the puncture line was measured. The angle between the puncture line and the posterior colon margin (P-C angle) was also measured. In total, 292 patients who underwent retroperitoneoscopic procedure were used to establish the retroperitoneal cavity using the direct puncture tunnel method, and complications in these patients were evaluated. The average L-P distance was 25.0 mm (left side) and 25.5 mm (right side) in the lateral decubitus position. The average P-C angle was 26.8° (left side) and 29.7° (right side). The retroperitoneal cavity was well established in all 292 patients, and no visceral or blood vessel injury occurred. CT scans in the lateral recumbent position indicate that there are no visceral and large blood vessels on the puncture path. The scans also provide a window for inserting the first trocar blindly into the retroperitoneum. A high success rate and low complication rate were observed clinically for the direct puncture tunnel method. We consider the direct puncture tunnel method to be a simple, effective, and safe way to establish the retroperitoneal cavity.</description><subject>Humans</subject><subject>Psoas Muscles</subject><subject>Punctures</subject><subject>Retroperitoneal Space - diagnostic imaging</subject><subject>Retroperitoneal Space - surgery</subject><subject>Tomography, X-Ray Computed</subject><issn>0892-7790</issn><issn>1557-900X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo90DtPwzAQwHELgWgpjKzII0uKH3ESs1WhPKQiECoSW-Q6F2qU2MV2UPvtScVjuuF-d8MfoXNKppQU8gpsPWWEyinJpDxAYypEnkhC3g7ReNizJM8lGaGTED4IoTyj_BiNOJU5F0U2Rtsb40FH_NxbHXsPeNlbCy1-hLh2NW6cx_MQ1ao1YW3sO45rwC8QvduAN9FZUC0u1ZeJu2s8syq6zmhcOtsY36lonMXK1rhsjTV6oPPt_g6shlN01Kg2wNnvnKDX2_myvE8WT3cP5WyRaM5ZTLgmGaPAGyG5pkQQLVaikEoIQjPGmOJMESmgyZUoSM0GlOZp0dQFa3jKOJ-gy5-_G-8-ewix6kzQ0LbKgutDxXiasrxIeTHQ5Idq70Lw0FQbbzrldxUl1T52NcSu9rGrfezBX_y-7lcd1P_6ry7_BuNmezA</recordid><startdate>202003</startdate><enddate>202003</enddate><creator>Lan, Jianhua</creator><creator>Liao, Banghua</creator><creator>Ai, Jianzhong</creator><creator>Zhou, Liang</creator><creator>Wang, Kunjie</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202003</creationdate><title>Direct Puncture Tunnel Method for Establishing the Retroperitoneal Cavity: Anatomic Confirmation and Clinical Experience</title><author>Lan, Jianhua ; Liao, Banghua ; Ai, Jianzhong ; Zhou, Liang ; Wang, Kunjie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-3c0621e3f593c1050c5b589a55016222a32a095ef7a580d23c14748fd82f34233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Humans</topic><topic>Psoas Muscles</topic><topic>Punctures</topic><topic>Retroperitoneal Space - diagnostic imaging</topic><topic>Retroperitoneal Space - surgery</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lan, Jianhua</creatorcontrib><creatorcontrib>Liao, Banghua</creatorcontrib><creatorcontrib>Ai, Jianzhong</creatorcontrib><creatorcontrib>Zhou, Liang</creatorcontrib><creatorcontrib>Wang, Kunjie</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of endourology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lan, Jianhua</au><au>Liao, Banghua</au><au>Ai, Jianzhong</au><au>Zhou, Liang</au><au>Wang, Kunjie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct Puncture Tunnel Method for Establishing the Retroperitoneal Cavity: Anatomic Confirmation and Clinical Experience</atitle><jtitle>Journal of endourology</jtitle><addtitle>J Endourol</addtitle><date>2020-03</date><risdate>2020</risdate><volume>34</volume><issue>3</issue><spage>298</spage><epage>303</epage><pages>298-303</pages><issn>0892-7790</issn><eissn>1557-900X</eissn><abstract>The feasibility and safety of the direct puncture tunnel method to establish the retroperitoneal cavity was assessed by CT and clinical experience. Ten patients who underwent retroperitoneoscopic procedure were scanned by CT in the lateral decubitus position. The distance between the lumbar fascia and psoas major muscle (L-P distance) on the puncture line was measured. The angle between the puncture line and the posterior colon margin (P-C angle) was also measured. In total, 292 patients who underwent retroperitoneoscopic procedure were used to establish the retroperitoneal cavity using the direct puncture tunnel method, and complications in these patients were evaluated. The average L-P distance was 25.0 mm (left side) and 25.5 mm (right side) in the lateral decubitus position. The average P-C angle was 26.8° (left side) and 29.7° (right side). The retroperitoneal cavity was well established in all 292 patients, and no visceral or blood vessel injury occurred. CT scans in the lateral recumbent position indicate that there are no visceral and large blood vessels on the puncture path. The scans also provide a window for inserting the first trocar blindly into the retroperitoneum. A high success rate and low complication rate were observed clinically for the direct puncture tunnel method. We consider the direct puncture tunnel method to be a simple, effective, and safe way to establish the retroperitoneal cavity.</abstract><cop>United States</cop><pmid>31973586</pmid><doi>10.1089/end.2019.0699</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0892-7790
ispartof Journal of endourology, 2020-03, Vol.34 (3), p.298-303
issn 0892-7790
1557-900X
language eng
recordid cdi_proquest_miscellaneous_2344278438
source MEDLINE; Alma/SFX Local Collection
subjects Humans
Psoas Muscles
Punctures
Retroperitoneal Space - diagnostic imaging
Retroperitoneal Space - surgery
Tomography, X-Ray Computed
title Direct Puncture Tunnel Method for Establishing the Retroperitoneal Cavity: Anatomic Confirmation and Clinical Experience
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T16%3A13%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct%20Puncture%20Tunnel%20Method%20for%20Establishing%20the%20Retroperitoneal%20Cavity:%20Anatomic%20Confirmation%20and%20Clinical%20Experience&rft.jtitle=Journal%20of%20endourology&rft.au=Lan,%20Jianhua&rft.date=2020-03&rft.volume=34&rft.issue=3&rft.spage=298&rft.epage=303&rft.pages=298-303&rft.issn=0892-7790&rft.eissn=1557-900X&rft_id=info:doi/10.1089/end.2019.0699&rft_dat=%3Cproquest_cross%3E2344278438%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2344278438&rft_id=info:pmid/31973586&rfr_iscdi=true