Influence of different post-contrast time points on dynamic contrast-enhanced (DCE) MRI T staging in breast cancer

•MD measured at TP1 was significantly different from those obtained at TPs 2-5.•T stage definition of BCLs is influenced by the TP used for MD measurement.•TPs 3, 4 and 5 are the preferred TPs for the assessment of T stage of BCLs.•Both axial and sagittal planes are useful for MD measurements of BCL...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of radiology 2020-03, Vol.124, p.108819-108819, Article 108819
Hauptverfasser: Romeo, Valeria, Picariello, Valentina, Pignata, Alma, Mancusi, Valeria, Stanzione, Arnaldo, Cuocolo, Renato, Di Crescenzo, Rosa, Accurso, Antonello, Staibano, Stefania, Imbriaco, Massimo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 108819
container_issue
container_start_page 108819
container_title European journal of radiology
container_volume 124
creator Romeo, Valeria
Picariello, Valentina
Pignata, Alma
Mancusi, Valeria
Stanzione, Arnaldo
Cuocolo, Renato
Di Crescenzo, Rosa
Accurso, Antonello
Staibano, Stefania
Imbriaco, Massimo
description •MD measured at TP1 was significantly different from those obtained at TPs 2-5.•T stage definition of BCLs is influenced by the TP used for MD measurement.•TPs 3, 4 and 5 are the preferred TPs for the assessment of T stage of BCLs.•Both axial and sagittal planes are useful for MD measurements of BCLs. to assess whether MRI T stage of breast cancer lesions (BCLs) is affected by maximum diameter (MD) measured at different post-contrast time points (TPs) on different acquisition planes on dynamic contrast-enhanced (DCE) MRI sequence. 53 DCE-MRI examinations of patients with BCLs were retrospectively selected. MD of BCLs was measured on axial, coronal and sagittal planes on DCE images at five different post-contrast TPs. Friedman test followed by Bonferroni-adjusted Wilcoxon-signed rank test for post-hoc analysis was performed to evaluate differences among the five measurements. Reliability of the measurements was evaluated with the intraclass correlation coefficient analysis. Differences between pathological and MRI T stage assessed at each TP on each acquisition plane were assessed using the Wilcoxon-sign rank test; p values
doi_str_mv 10.1016/j.ejrad.2020.108819
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2343040544</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0720048X20300085</els_id><sourcerecordid>2343040544</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-8e768a47a96659a14a55aaa195d2f67533b29b0b1e79cffb0880965316ec1a123</originalsourceid><addsrcrecordid>eNp9kE1P3DAQhi0E6m63_QVIlY9wyOKPJI4PHNBCYSUQEqISN8txxtSrjbPYTiX-PQ4LPXIaaeaZd-wHoWNKlpTQ-myzhE3Q3ZIRNnWahsoDNKeNYIUQTByiORGMFKRsnmboe4wbQkhVSvYNzTiVVVNzOkdh7e12BG8ADxZ3zloI4BPeDTEVZvAp6Jhwcj3klvMp4sHj7tXr3hn8OS_A_9U5osMnl6urU3z3sMaPOCb97Pwzdh63AaYYM0HhBzqyehvh50ddoD-_rx5XN8Xt_fV6dXFbGF7JVDQg6kaXQsu6rqSmpa4qrXV-ecdsLSrOWyZb0lIQ0ljbZgFE1hWnNRiqKeMLdLLP3YXhZYSYVO-ige1WexjGqBgvOSmzkjKjfI-aMMQYwKpdcL0Or4oSNclWG_UuW02y1V523vr1cWBse-j-73zazcD5HoD8zX8OgorGTa47F8Ak1Q3uywNvPQmQnQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2343040544</pqid></control><display><type>article</type><title>Influence of different post-contrast time points on dynamic contrast-enhanced (DCE) MRI T staging in breast cancer</title><source>Access via ScienceDirect (Elsevier)</source><creator>Romeo, Valeria ; Picariello, Valentina ; Pignata, Alma ; Mancusi, Valeria ; Stanzione, Arnaldo ; Cuocolo, Renato ; Di Crescenzo, Rosa ; Accurso, Antonello ; Staibano, Stefania ; Imbriaco, Massimo</creator><creatorcontrib>Romeo, Valeria ; Picariello, Valentina ; Pignata, Alma ; Mancusi, Valeria ; Stanzione, Arnaldo ; Cuocolo, Renato ; Di Crescenzo, Rosa ; Accurso, Antonello ; Staibano, Stefania ; Imbriaco, Massimo</creatorcontrib><description>•MD measured at TP1 was significantly different from those obtained at TPs 2-5.•T stage definition of BCLs is influenced by the TP used for MD measurement.•TPs 3, 4 and 5 are the preferred TPs for the assessment of T stage of BCLs.•Both axial and sagittal planes are useful for MD measurements of BCLs. to assess whether MRI T stage of breast cancer lesions (BCLs) is affected by maximum diameter (MD) measured at different post-contrast time points (TPs) on different acquisition planes on dynamic contrast-enhanced (DCE) MRI sequence. 53 DCE-MRI examinations of patients with BCLs were retrospectively selected. MD of BCLs was measured on axial, coronal and sagittal planes on DCE images at five different post-contrast TPs. Friedman test followed by Bonferroni-adjusted Wilcoxon-signed rank test for post-hoc analysis was performed to evaluate differences among the five measurements. Reliability of the measurements was evaluated with the intraclass correlation coefficient analysis. Differences between pathological and MRI T stage assessed at each TP on each acquisition plane were assessed using the Wilcoxon-sign rank test; p values &lt;0.05 were considered statistically significant. on axial, coronal and sagittal planes, MD measured at TP1 was significantly different (p &lt; 0.0001) compared to those obtained at the subsequent TPs. No significant differences were found between MD measured at TPs 3, 4 and 5. Intra and inter-observer reliability resulted as very good, with ICC ranging between 0.915–0.992 and 0.845–0.911, respectively. MRI T stage assessed at TP1 on axial and sagittal plane as well as at all TPs on coronal plane was significantly different from pathological T stage. MRI T stage definition of BCLs is significantly affected by the TP used for lesions’ MD measurement. TPs 3, 4 and 5 are the preferred TPs for the assessment of MRI T stage of BCLs on both axial and sagittal planes.</description><identifier>ISSN: 0720-048X</identifier><identifier>EISSN: 1872-7727</identifier><identifier>DOI: 10.1016/j.ejrad.2020.108819</identifier><identifier>PMID: 31958631</identifier><language>eng</language><publisher>Ireland: Elsevier B.V</publisher><subject>Breast cancer ; Breast MRI ; DCE-MRI ; MRI T-Stage ; Post-contrast time points ; Pre-operative MRI</subject><ispartof>European journal of radiology, 2020-03, Vol.124, p.108819-108819, Article 108819</ispartof><rights>2020 Elsevier B.V.</rights><rights>Copyright © 2020 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-8e768a47a96659a14a55aaa195d2f67533b29b0b1e79cffb0880965316ec1a123</citedby><cites>FETCH-LOGICAL-c359t-8e768a47a96659a14a55aaa195d2f67533b29b0b1e79cffb0880965316ec1a123</cites><orcidid>0000-0002-1603-6396</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ejrad.2020.108819$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31958631$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Romeo, Valeria</creatorcontrib><creatorcontrib>Picariello, Valentina</creatorcontrib><creatorcontrib>Pignata, Alma</creatorcontrib><creatorcontrib>Mancusi, Valeria</creatorcontrib><creatorcontrib>Stanzione, Arnaldo</creatorcontrib><creatorcontrib>Cuocolo, Renato</creatorcontrib><creatorcontrib>Di Crescenzo, Rosa</creatorcontrib><creatorcontrib>Accurso, Antonello</creatorcontrib><creatorcontrib>Staibano, Stefania</creatorcontrib><creatorcontrib>Imbriaco, Massimo</creatorcontrib><title>Influence of different post-contrast time points on dynamic contrast-enhanced (DCE) MRI T staging in breast cancer</title><title>European journal of radiology</title><addtitle>Eur J Radiol</addtitle><description>•MD measured at TP1 was significantly different from those obtained at TPs 2-5.•T stage definition of BCLs is influenced by the TP used for MD measurement.•TPs 3, 4 and 5 are the preferred TPs for the assessment of T stage of BCLs.•Both axial and sagittal planes are useful for MD measurements of BCLs. to assess whether MRI T stage of breast cancer lesions (BCLs) is affected by maximum diameter (MD) measured at different post-contrast time points (TPs) on different acquisition planes on dynamic contrast-enhanced (DCE) MRI sequence. 53 DCE-MRI examinations of patients with BCLs were retrospectively selected. MD of BCLs was measured on axial, coronal and sagittal planes on DCE images at five different post-contrast TPs. Friedman test followed by Bonferroni-adjusted Wilcoxon-signed rank test for post-hoc analysis was performed to evaluate differences among the five measurements. Reliability of the measurements was evaluated with the intraclass correlation coefficient analysis. Differences between pathological and MRI T stage assessed at each TP on each acquisition plane were assessed using the Wilcoxon-sign rank test; p values &lt;0.05 were considered statistically significant. on axial, coronal and sagittal planes, MD measured at TP1 was significantly different (p &lt; 0.0001) compared to those obtained at the subsequent TPs. No significant differences were found between MD measured at TPs 3, 4 and 5. Intra and inter-observer reliability resulted as very good, with ICC ranging between 0.915–0.992 and 0.845–0.911, respectively. MRI T stage assessed at TP1 on axial and sagittal plane as well as at all TPs on coronal plane was significantly different from pathological T stage. MRI T stage definition of BCLs is significantly affected by the TP used for lesions’ MD measurement. TPs 3, 4 and 5 are the preferred TPs for the assessment of MRI T stage of BCLs on both axial and sagittal planes.</description><subject>Breast cancer</subject><subject>Breast MRI</subject><subject>DCE-MRI</subject><subject>MRI T-Stage</subject><subject>Post-contrast time points</subject><subject>Pre-operative MRI</subject><issn>0720-048X</issn><issn>1872-7727</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kE1P3DAQhi0E6m63_QVIlY9wyOKPJI4PHNBCYSUQEqISN8txxtSrjbPYTiX-PQ4LPXIaaeaZd-wHoWNKlpTQ-myzhE3Q3ZIRNnWahsoDNKeNYIUQTByiORGMFKRsnmboe4wbQkhVSvYNzTiVVVNzOkdh7e12BG8ADxZ3zloI4BPeDTEVZvAp6Jhwcj3klvMp4sHj7tXr3hn8OS_A_9U5osMnl6urU3z3sMaPOCb97Pwzdh63AaYYM0HhBzqyehvh50ddoD-_rx5XN8Xt_fV6dXFbGF7JVDQg6kaXQsu6rqSmpa4qrXV-ecdsLSrOWyZb0lIQ0ljbZgFE1hWnNRiqKeMLdLLP3YXhZYSYVO-ige1WexjGqBgvOSmzkjKjfI-aMMQYwKpdcL0Or4oSNclWG_UuW02y1V523vr1cWBse-j-73zazcD5HoD8zX8OgorGTa47F8Ak1Q3uywNvPQmQnQ</recordid><startdate>202003</startdate><enddate>202003</enddate><creator>Romeo, Valeria</creator><creator>Picariello, Valentina</creator><creator>Pignata, Alma</creator><creator>Mancusi, Valeria</creator><creator>Stanzione, Arnaldo</creator><creator>Cuocolo, Renato</creator><creator>Di Crescenzo, Rosa</creator><creator>Accurso, Antonello</creator><creator>Staibano, Stefania</creator><creator>Imbriaco, Massimo</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1603-6396</orcidid></search><sort><creationdate>202003</creationdate><title>Influence of different post-contrast time points on dynamic contrast-enhanced (DCE) MRI T staging in breast cancer</title><author>Romeo, Valeria ; Picariello, Valentina ; Pignata, Alma ; Mancusi, Valeria ; Stanzione, Arnaldo ; Cuocolo, Renato ; Di Crescenzo, Rosa ; Accurso, Antonello ; Staibano, Stefania ; Imbriaco, Massimo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-8e768a47a96659a14a55aaa195d2f67533b29b0b1e79cffb0880965316ec1a123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Breast cancer</topic><topic>Breast MRI</topic><topic>DCE-MRI</topic><topic>MRI T-Stage</topic><topic>Post-contrast time points</topic><topic>Pre-operative MRI</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Romeo, Valeria</creatorcontrib><creatorcontrib>Picariello, Valentina</creatorcontrib><creatorcontrib>Pignata, Alma</creatorcontrib><creatorcontrib>Mancusi, Valeria</creatorcontrib><creatorcontrib>Stanzione, Arnaldo</creatorcontrib><creatorcontrib>Cuocolo, Renato</creatorcontrib><creatorcontrib>Di Crescenzo, Rosa</creatorcontrib><creatorcontrib>Accurso, Antonello</creatorcontrib><creatorcontrib>Staibano, Stefania</creatorcontrib><creatorcontrib>Imbriaco, Massimo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Romeo, Valeria</au><au>Picariello, Valentina</au><au>Pignata, Alma</au><au>Mancusi, Valeria</au><au>Stanzione, Arnaldo</au><au>Cuocolo, Renato</au><au>Di Crescenzo, Rosa</au><au>Accurso, Antonello</au><au>Staibano, Stefania</au><au>Imbriaco, Massimo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of different post-contrast time points on dynamic contrast-enhanced (DCE) MRI T staging in breast cancer</atitle><jtitle>European journal of radiology</jtitle><addtitle>Eur J Radiol</addtitle><date>2020-03</date><risdate>2020</risdate><volume>124</volume><spage>108819</spage><epage>108819</epage><pages>108819-108819</pages><artnum>108819</artnum><issn>0720-048X</issn><eissn>1872-7727</eissn><abstract>•MD measured at TP1 was significantly different from those obtained at TPs 2-5.•T stage definition of BCLs is influenced by the TP used for MD measurement.•TPs 3, 4 and 5 are the preferred TPs for the assessment of T stage of BCLs.•Both axial and sagittal planes are useful for MD measurements of BCLs. to assess whether MRI T stage of breast cancer lesions (BCLs) is affected by maximum diameter (MD) measured at different post-contrast time points (TPs) on different acquisition planes on dynamic contrast-enhanced (DCE) MRI sequence. 53 DCE-MRI examinations of patients with BCLs were retrospectively selected. MD of BCLs was measured on axial, coronal and sagittal planes on DCE images at five different post-contrast TPs. Friedman test followed by Bonferroni-adjusted Wilcoxon-signed rank test for post-hoc analysis was performed to evaluate differences among the five measurements. Reliability of the measurements was evaluated with the intraclass correlation coefficient analysis. Differences between pathological and MRI T stage assessed at each TP on each acquisition plane were assessed using the Wilcoxon-sign rank test; p values &lt;0.05 were considered statistically significant. on axial, coronal and sagittal planes, MD measured at TP1 was significantly different (p &lt; 0.0001) compared to those obtained at the subsequent TPs. No significant differences were found between MD measured at TPs 3, 4 and 5. Intra and inter-observer reliability resulted as very good, with ICC ranging between 0.915–0.992 and 0.845–0.911, respectively. MRI T stage assessed at TP1 on axial and sagittal plane as well as at all TPs on coronal plane was significantly different from pathological T stage. MRI T stage definition of BCLs is significantly affected by the TP used for lesions’ MD measurement. TPs 3, 4 and 5 are the preferred TPs for the assessment of MRI T stage of BCLs on both axial and sagittal planes.</abstract><cop>Ireland</cop><pub>Elsevier B.V</pub><pmid>31958631</pmid><doi>10.1016/j.ejrad.2020.108819</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-1603-6396</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0720-048X
ispartof European journal of radiology, 2020-03, Vol.124, p.108819-108819, Article 108819
issn 0720-048X
1872-7727
language eng
recordid cdi_proquest_miscellaneous_2343040544
source Access via ScienceDirect (Elsevier)
subjects Breast cancer
Breast MRI
DCE-MRI
MRI T-Stage
Post-contrast time points
Pre-operative MRI
title Influence of different post-contrast time points on dynamic contrast-enhanced (DCE) MRI T staging in breast cancer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T15%3A16%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20different%20post-contrast%20time%20points%20on%20dynamic%20contrast-enhanced%20(DCE)%20MRI%20T%20staging%20in%20breast%20cancer&rft.jtitle=European%20journal%20of%20radiology&rft.au=Romeo,%20Valeria&rft.date=2020-03&rft.volume=124&rft.spage=108819&rft.epage=108819&rft.pages=108819-108819&rft.artnum=108819&rft.issn=0720-048X&rft.eissn=1872-7727&rft_id=info:doi/10.1016/j.ejrad.2020.108819&rft_dat=%3Cproquest_cross%3E2343040544%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2343040544&rft_id=info:pmid/31958631&rft_els_id=S0720048X20300085&rfr_iscdi=true