Automatic multi‐organ segmentation in dual‐energy CT (DECT) with dedicated 3D fully convolutional DECT networks
Purpose Dual‐energy computed tomography (DECT) has shown great potential in many clinical applications. By incorporating the information from two different energy spectra, DECT provides higher contrast and reveals more material differences of tissues compared to conventional single‐energy CT (SECT)....
Gespeichert in:
Veröffentlicht in: | Medical physics (Lancaster) 2020-02, Vol.47 (2), p.552-562 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 562 |
---|---|
container_issue | 2 |
container_start_page | 552 |
container_title | Medical physics (Lancaster) |
container_volume | 47 |
creator | Chen, Shuqing Zhong, Xia Hu, Shiyang Dorn, Sabrina Kachelrieß, Marc Lell, Michael Maier, Andreas |
description | Purpose
Dual‐energy computed tomography (DECT) has shown great potential in many clinical applications. By incorporating the information from two different energy spectra, DECT provides higher contrast and reveals more material differences of tissues compared to conventional single‐energy CT (SECT). Recent research shows that automatic multi‐organ segmentation of DECT data can improve DECT clinical applications. However, most segmentation methods are designed for SECT, while DECT has been significantly less pronounced in research. Therefore, a novel approach is required that is able to take full advantage of the extra information provided by DECT.
Methods
In the scope of this work, we proposed four three‐dimensional (3D) fully convolutional neural network algorithms for the automatic segmentation of DECT data. We incorporated the extra energy information differently and embedded the fusion of information in each of the network architectures.
Results
Quantitative evaluation using 45 thorax/abdomen DECT datasets acquired with a clinical dual‐source CT system was investigated. The segmentation of six thoracic and abdominal organs (left and right lungs, liver, spleen, and left and right kidneys) were evaluated using a fivefold cross‐validation strategy. In all of the tests, we achieved the best average Dice coefficients of 98% for the right lung, 98% for the left lung, 96% for the liver, 92% for the spleen, 95% for the right kidney, 93% for the left kidney, respectively. The network architectures exploit dual‐energy spectra and outperform deep learning for SECT.
Conclusions
The results of the cross‐validation show that our methods are feasible and promising. Successful tests on special clinical cases reveal that our methods have high adaptability in the practical application. |
doi_str_mv | 10.1002/mp.13950 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2323481636</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2323481636</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3550-5abec2ac48fd6e572d9c165d3069f30271402876398b81dbd33b4b4a3257b3633</originalsourceid><addsrcrecordid>eNp1kLtOwzAUhi0EgnKReALkEYbAsY-dy4habhIIhjJHju2UgBOXOKHqxiPwjDwJKQU2pjP83_mGj5BDBqcMgJ_V81OGmYQNMuIiwUhwyDbJCCATERcgd8huCM8AEKOEbbKDLGUxZHJEwnnf-Vp1laZ177rq8_3DtzPV0GBntW26YfENrRpqeuWG0Ta2nS3peEqPJxfj6QldVN0TNdZUWnXWUJzQsnduSbVv3rzrV-_K0RVLG9stfPsS9slWqVywBz93jzxeXkzH19Ht_dXN-Pw20iglRFIVVnOlRVqa2MqEm0yzWBqEOCsReMIE8DSJMUuLlJnCIBaiEAq5TAqMEffI8do7b_1rb0OX11XQ1jnVWN-HnCNHMYQY2D9Utz6E1pb5vK1q1S5zBvkqcV7P8-_EA3r0Y-2L2po_8LfpAERrYFE5u_xXlN89rIVflZCFkw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2323481636</pqid></control><display><type>article</type><title>Automatic multi‐organ segmentation in dual‐energy CT (DECT) with dedicated 3D fully convolutional DECT networks</title><source>Wiley Online Library All Journals</source><source>Alma/SFX Local Collection</source><creator>Chen, Shuqing ; Zhong, Xia ; Hu, Shiyang ; Dorn, Sabrina ; Kachelrieß, Marc ; Lell, Michael ; Maier, Andreas</creator><creatorcontrib>Chen, Shuqing ; Zhong, Xia ; Hu, Shiyang ; Dorn, Sabrina ; Kachelrieß, Marc ; Lell, Michael ; Maier, Andreas</creatorcontrib><description>Purpose
Dual‐energy computed tomography (DECT) has shown great potential in many clinical applications. By incorporating the information from two different energy spectra, DECT provides higher contrast and reveals more material differences of tissues compared to conventional single‐energy CT (SECT). Recent research shows that automatic multi‐organ segmentation of DECT data can improve DECT clinical applications. However, most segmentation methods are designed for SECT, while DECT has been significantly less pronounced in research. Therefore, a novel approach is required that is able to take full advantage of the extra information provided by DECT.
Methods
In the scope of this work, we proposed four three‐dimensional (3D) fully convolutional neural network algorithms for the automatic segmentation of DECT data. We incorporated the extra energy information differently and embedded the fusion of information in each of the network architectures.
Results
Quantitative evaluation using 45 thorax/abdomen DECT datasets acquired with a clinical dual‐source CT system was investigated. The segmentation of six thoracic and abdominal organs (left and right lungs, liver, spleen, and left and right kidneys) were evaluated using a fivefold cross‐validation strategy. In all of the tests, we achieved the best average Dice coefficients of 98% for the right lung, 98% for the left lung, 96% for the liver, 92% for the spleen, 95% for the right kidney, 93% for the left kidney, respectively. The network architectures exploit dual‐energy spectra and outperform deep learning for SECT.
Conclusions
The results of the cross‐validation show that our methods are feasible and promising. Successful tests on special clinical cases reveal that our methods have high adaptability in the practical application.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1002/mp.13950</identifier><identifier>PMID: 31816095</identifier><language>eng</language><publisher>United States</publisher><subject>DECT ; deep learning ; FCN ; multi‐organ ; U‐Net</subject><ispartof>Medical physics (Lancaster), 2020-02, Vol.47 (2), p.552-562</ispartof><rights>2019 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3550-5abec2ac48fd6e572d9c165d3069f30271402876398b81dbd33b4b4a3257b3633</citedby><cites>FETCH-LOGICAL-c3550-5abec2ac48fd6e572d9c165d3069f30271402876398b81dbd33b4b4a3257b3633</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmp.13950$$EPDF$$P50$$Gwiley$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmp.13950$$EHTML$$P50$$Gwiley$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31816095$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Shuqing</creatorcontrib><creatorcontrib>Zhong, Xia</creatorcontrib><creatorcontrib>Hu, Shiyang</creatorcontrib><creatorcontrib>Dorn, Sabrina</creatorcontrib><creatorcontrib>Kachelrieß, Marc</creatorcontrib><creatorcontrib>Lell, Michael</creatorcontrib><creatorcontrib>Maier, Andreas</creatorcontrib><title>Automatic multi‐organ segmentation in dual‐energy CT (DECT) with dedicated 3D fully convolutional DECT networks</title><title>Medical physics (Lancaster)</title><addtitle>Med Phys</addtitle><description>Purpose
Dual‐energy computed tomography (DECT) has shown great potential in many clinical applications. By incorporating the information from two different energy spectra, DECT provides higher contrast and reveals more material differences of tissues compared to conventional single‐energy CT (SECT). Recent research shows that automatic multi‐organ segmentation of DECT data can improve DECT clinical applications. However, most segmentation methods are designed for SECT, while DECT has been significantly less pronounced in research. Therefore, a novel approach is required that is able to take full advantage of the extra information provided by DECT.
Methods
In the scope of this work, we proposed four three‐dimensional (3D) fully convolutional neural network algorithms for the automatic segmentation of DECT data. We incorporated the extra energy information differently and embedded the fusion of information in each of the network architectures.
Results
Quantitative evaluation using 45 thorax/abdomen DECT datasets acquired with a clinical dual‐source CT system was investigated. The segmentation of six thoracic and abdominal organs (left and right lungs, liver, spleen, and left and right kidneys) were evaluated using a fivefold cross‐validation strategy. In all of the tests, we achieved the best average Dice coefficients of 98% for the right lung, 98% for the left lung, 96% for the liver, 92% for the spleen, 95% for the right kidney, 93% for the left kidney, respectively. The network architectures exploit dual‐energy spectra and outperform deep learning for SECT.
Conclusions
The results of the cross‐validation show that our methods are feasible and promising. Successful tests on special clinical cases reveal that our methods have high adaptability in the practical application.</description><subject>DECT</subject><subject>deep learning</subject><subject>FCN</subject><subject>multi‐organ</subject><subject>U‐Net</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>24P</sourceid><sourceid>WIN</sourceid><recordid>eNp1kLtOwzAUhi0EgnKReALkEYbAsY-dy4habhIIhjJHju2UgBOXOKHqxiPwjDwJKQU2pjP83_mGj5BDBqcMgJ_V81OGmYQNMuIiwUhwyDbJCCATERcgd8huCM8AEKOEbbKDLGUxZHJEwnnf-Vp1laZ177rq8_3DtzPV0GBntW26YfENrRpqeuWG0Ta2nS3peEqPJxfj6QldVN0TNdZUWnXWUJzQsnduSbVv3rzrV-_K0RVLG9stfPsS9slWqVywBz93jzxeXkzH19Ht_dXN-Pw20iglRFIVVnOlRVqa2MqEm0yzWBqEOCsReMIE8DSJMUuLlJnCIBaiEAq5TAqMEffI8do7b_1rb0OX11XQ1jnVWN-HnCNHMYQY2D9Utz6E1pb5vK1q1S5zBvkqcV7P8-_EA3r0Y-2L2po_8LfpAERrYFE5u_xXlN89rIVflZCFkw</recordid><startdate>202002</startdate><enddate>202002</enddate><creator>Chen, Shuqing</creator><creator>Zhong, Xia</creator><creator>Hu, Shiyang</creator><creator>Dorn, Sabrina</creator><creator>Kachelrieß, Marc</creator><creator>Lell, Michael</creator><creator>Maier, Andreas</creator><scope>24P</scope><scope>WIN</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202002</creationdate><title>Automatic multi‐organ segmentation in dual‐energy CT (DECT) with dedicated 3D fully convolutional DECT networks</title><author>Chen, Shuqing ; Zhong, Xia ; Hu, Shiyang ; Dorn, Sabrina ; Kachelrieß, Marc ; Lell, Michael ; Maier, Andreas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3550-5abec2ac48fd6e572d9c165d3069f30271402876398b81dbd33b4b4a3257b3633</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>DECT</topic><topic>deep learning</topic><topic>FCN</topic><topic>multi‐organ</topic><topic>U‐Net</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Shuqing</creatorcontrib><creatorcontrib>Zhong, Xia</creatorcontrib><creatorcontrib>Hu, Shiyang</creatorcontrib><creatorcontrib>Dorn, Sabrina</creatorcontrib><creatorcontrib>Kachelrieß, Marc</creatorcontrib><creatorcontrib>Lell, Michael</creatorcontrib><creatorcontrib>Maier, Andreas</creatorcontrib><collection>Wiley-Blackwell Open Access Titles</collection><collection>Wiley Free Content</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Shuqing</au><au>Zhong, Xia</au><au>Hu, Shiyang</au><au>Dorn, Sabrina</au><au>Kachelrieß, Marc</au><au>Lell, Michael</au><au>Maier, Andreas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automatic multi‐organ segmentation in dual‐energy CT (DECT) with dedicated 3D fully convolutional DECT networks</atitle><jtitle>Medical physics (Lancaster)</jtitle><addtitle>Med Phys</addtitle><date>2020-02</date><risdate>2020</risdate><volume>47</volume><issue>2</issue><spage>552</spage><epage>562</epage><pages>552-562</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><abstract>Purpose
Dual‐energy computed tomography (DECT) has shown great potential in many clinical applications. By incorporating the information from two different energy spectra, DECT provides higher contrast and reveals more material differences of tissues compared to conventional single‐energy CT (SECT). Recent research shows that automatic multi‐organ segmentation of DECT data can improve DECT clinical applications. However, most segmentation methods are designed for SECT, while DECT has been significantly less pronounced in research. Therefore, a novel approach is required that is able to take full advantage of the extra information provided by DECT.
Methods
In the scope of this work, we proposed four three‐dimensional (3D) fully convolutional neural network algorithms for the automatic segmentation of DECT data. We incorporated the extra energy information differently and embedded the fusion of information in each of the network architectures.
Results
Quantitative evaluation using 45 thorax/abdomen DECT datasets acquired with a clinical dual‐source CT system was investigated. The segmentation of six thoracic and abdominal organs (left and right lungs, liver, spleen, and left and right kidneys) were evaluated using a fivefold cross‐validation strategy. In all of the tests, we achieved the best average Dice coefficients of 98% for the right lung, 98% for the left lung, 96% for the liver, 92% for the spleen, 95% for the right kidney, 93% for the left kidney, respectively. The network architectures exploit dual‐energy spectra and outperform deep learning for SECT.
Conclusions
The results of the cross‐validation show that our methods are feasible and promising. Successful tests on special clinical cases reveal that our methods have high adaptability in the practical application.</abstract><cop>United States</cop><pmid>31816095</pmid><doi>10.1002/mp.13950</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-2405 |
ispartof | Medical physics (Lancaster), 2020-02, Vol.47 (2), p.552-562 |
issn | 0094-2405 2473-4209 |
language | eng |
recordid | cdi_proquest_miscellaneous_2323481636 |
source | Wiley Online Library All Journals; Alma/SFX Local Collection |
subjects | DECT deep learning FCN multi‐organ U‐Net |
title | Automatic multi‐organ segmentation in dual‐energy CT (DECT) with dedicated 3D fully convolutional DECT networks |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T04%3A04%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automatic%20multi%E2%80%90organ%20segmentation%20in%20dual%E2%80%90energy%20CT%20(DECT)%20with%20dedicated%203D%20fully%20convolutional%20DECT%20networks&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Chen,%20Shuqing&rft.date=2020-02&rft.volume=47&rft.issue=2&rft.spage=552&rft.epage=562&rft.pages=552-562&rft.issn=0094-2405&rft.eissn=2473-4209&rft_id=info:doi/10.1002/mp.13950&rft_dat=%3Cproquest_cross%3E2323481636%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2323481636&rft_id=info:pmid/31816095&rfr_iscdi=true |