Integrating machine learning techniques and physiology based heart rate features for antepartum fetal monitoring

[Display omitted] Intrauterine Growth Restriction (IUGR) is a fetal condition defined as the abnormal rate of fetal growth. The pathology is a documented cause of fetal and neonatal morbidity and mortality. In clinical practice, diagnosis is confirmed at birth and may only be suspected during pregna...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Computer methods and programs in biomedicine 2020-03, Vol.185, p.105015-105015, Article 105015
Hauptverfasser: Signorini, Maria G., Pini, Nicolò, Malovini, Alberto, Bellazzi, Riccardo, Magenes, Giovanni
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 105015
container_issue
container_start_page 105015
container_title Computer methods and programs in biomedicine
container_volume 185
creator Signorini, Maria G.
Pini, Nicolò
Malovini, Alberto
Bellazzi, Riccardo
Magenes, Giovanni
description [Display omitted] Intrauterine Growth Restriction (IUGR) is a fetal condition defined as the abnormal rate of fetal growth. The pathology is a documented cause of fetal and neonatal morbidity and mortality. In clinical practice, diagnosis is confirmed at birth and may only be suspected during pregnancy. Therefore, designing an accurate model for the early and prompt identification of pathology in the antepartum period is crucial in view of pregnancy management. We tested the performance of 15 machine learning techniques in discriminating healthy versus IUGR fetuses. The various models were trained with a set of 12 physiology based heart rate features extracted from a single antepartum CardioTocographic (CTG) recording. The reason for the utilization of time, frequency, and nonlinear indices is based on their standalone documented ability to describe several physiological and pathological fetal conditions. We validated our approach on a database of 60 healthy and 60 IUGR fetuses. The machine learning methodology achieving the best performance was Random Forests. Specifically, we obtained a mean classification accuracy of 0.911 [0.860, 0.961 (0.95 confidence interval)] averaged over 10 test sets (10 Fold Cross Validation). Similar results were provided by Classification Trees, Logistic Regression, and Support Vector Machines. A features ranking procedure highlighted that nonlinear indices showed the highest capability to discriminate between the considered fetal conditions. Nevertheless, is the combination of features investigating CTG signal in different domains, that contributes to an increase in classification accuracy. We provided validation of an accurate artificially intelligence framework for the diagnosis of IUGR condition in the antepartum period. The employed physiology based heart rate features constitute an interpretable link between the machine learning results and the quantitative estimators of fetal wellbeing.
doi_str_mv 10.1016/j.cmpb.2019.105015
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2311926214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0169260719308107</els_id><sourcerecordid>2311926214</sourcerecordid><originalsourceid>FETCH-LOGICAL-c400t-654e05516f60574501c89b7c47382ae0273fb8553a191a61d330d731f92541b83</originalsourceid><addsrcrecordid>eNp9kEtr3DAUhUVoSSaPP5BF0LIbT_WwJBu6CSFpAoFu2rWQ5esZDbbkSnJg_n1lJsmyqwvnfufAOQjdUrKlhMrvh62d5m7LCG2LIAgVZ2hDG8UqJaT4gjYFaismibpAlykdCCFMCHmOLjiVqlFtvUHzi8-wiyY7v8OTsXvnAY9gol-FDHbv3d8FEja-x_P-mFwYw-6IO5Ogx_sCZlzcgAcweYkFHEIscIa5vJap6NmMeAre5RBL5jX6Opgxwc37vUJ_nh5_PzxXr79-vjzcv1a2JiRXUtRAhKBykESoupSzTdspWyveMAOEKT50jRDc0JYaSXvOSa84HVomato1_Ap9O-XOMawFsp5csjCOxkNYkmac0pZJRuuCshNqY0gpwqDn6CYTj5oSvS6tD3pdWq9L69PSxXT3nr90E_Sflo9pC_DjBEBp-eYg6mQdeAu9i2Cz7oP7X_4_x8yPvw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2311926214</pqid></control><display><type>article</type><title>Integrating machine learning techniques and physiology based heart rate features for antepartum fetal monitoring</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Signorini, Maria G. ; Pini, Nicolò ; Malovini, Alberto ; Bellazzi, Riccardo ; Magenes, Giovanni</creator><creatorcontrib>Signorini, Maria G. ; Pini, Nicolò ; Malovini, Alberto ; Bellazzi, Riccardo ; Magenes, Giovanni</creatorcontrib><description>[Display omitted] Intrauterine Growth Restriction (IUGR) is a fetal condition defined as the abnormal rate of fetal growth. The pathology is a documented cause of fetal and neonatal morbidity and mortality. In clinical practice, diagnosis is confirmed at birth and may only be suspected during pregnancy. Therefore, designing an accurate model for the early and prompt identification of pathology in the antepartum period is crucial in view of pregnancy management. We tested the performance of 15 machine learning techniques in discriminating healthy versus IUGR fetuses. The various models were trained with a set of 12 physiology based heart rate features extracted from a single antepartum CardioTocographic (CTG) recording. The reason for the utilization of time, frequency, and nonlinear indices is based on their standalone documented ability to describe several physiological and pathological fetal conditions. We validated our approach on a database of 60 healthy and 60 IUGR fetuses. The machine learning methodology achieving the best performance was Random Forests. Specifically, we obtained a mean classification accuracy of 0.911 [0.860, 0.961 (0.95 confidence interval)] averaged over 10 test sets (10 Fold Cross Validation). Similar results were provided by Classification Trees, Logistic Regression, and Support Vector Machines. A features ranking procedure highlighted that nonlinear indices showed the highest capability to discriminate between the considered fetal conditions. Nevertheless, is the combination of features investigating CTG signal in different domains, that contributes to an increase in classification accuracy. We provided validation of an accurate artificially intelligence framework for the diagnosis of IUGR condition in the antepartum period. The employed physiology based heart rate features constitute an interpretable link between the machine learning results and the quantitative estimators of fetal wellbeing.</description><identifier>ISSN: 0169-2607</identifier><identifier>EISSN: 1872-7565</identifier><identifier>DOI: 10.1016/j.cmpb.2019.105015</identifier><identifier>PMID: 31678794</identifier><language>eng</language><publisher>Ireland: Elsevier B.V</publisher><subject>Cardiotocography - methods ; Female ; Fetal Heart Rate monitoring ; Fetal Monitoring - methods ; Heart Rate, Fetal ; Humans ; Machine Learning ; Machine learning and statistical models ; Multivariate analysis ; Physiology-based features ; Predictive analytics ; Pregnancy ; Reproducibility of Results ; Systems Integration</subject><ispartof>Computer methods and programs in biomedicine, 2020-03, Vol.185, p.105015-105015, Article 105015</ispartof><rights>2019</rights><rights>Copyright © 2019. Published by Elsevier B.V.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c400t-654e05516f60574501c89b7c47382ae0273fb8553a191a61d330d731f92541b83</citedby><cites>FETCH-LOGICAL-c400t-654e05516f60574501c89b7c47382ae0273fb8553a191a61d330d731f92541b83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.cmpb.2019.105015$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31678794$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Signorini, Maria G.</creatorcontrib><creatorcontrib>Pini, Nicolò</creatorcontrib><creatorcontrib>Malovini, Alberto</creatorcontrib><creatorcontrib>Bellazzi, Riccardo</creatorcontrib><creatorcontrib>Magenes, Giovanni</creatorcontrib><title>Integrating machine learning techniques and physiology based heart rate features for antepartum fetal monitoring</title><title>Computer methods and programs in biomedicine</title><addtitle>Comput Methods Programs Biomed</addtitle><description>[Display omitted] Intrauterine Growth Restriction (IUGR) is a fetal condition defined as the abnormal rate of fetal growth. The pathology is a documented cause of fetal and neonatal morbidity and mortality. In clinical practice, diagnosis is confirmed at birth and may only be suspected during pregnancy. Therefore, designing an accurate model for the early and prompt identification of pathology in the antepartum period is crucial in view of pregnancy management. We tested the performance of 15 machine learning techniques in discriminating healthy versus IUGR fetuses. The various models were trained with a set of 12 physiology based heart rate features extracted from a single antepartum CardioTocographic (CTG) recording. The reason for the utilization of time, frequency, and nonlinear indices is based on their standalone documented ability to describe several physiological and pathological fetal conditions. We validated our approach on a database of 60 healthy and 60 IUGR fetuses. The machine learning methodology achieving the best performance was Random Forests. Specifically, we obtained a mean classification accuracy of 0.911 [0.860, 0.961 (0.95 confidence interval)] averaged over 10 test sets (10 Fold Cross Validation). Similar results were provided by Classification Trees, Logistic Regression, and Support Vector Machines. A features ranking procedure highlighted that nonlinear indices showed the highest capability to discriminate between the considered fetal conditions. Nevertheless, is the combination of features investigating CTG signal in different domains, that contributes to an increase in classification accuracy. We provided validation of an accurate artificially intelligence framework for the diagnosis of IUGR condition in the antepartum period. The employed physiology based heart rate features constitute an interpretable link between the machine learning results and the quantitative estimators of fetal wellbeing.</description><subject>Cardiotocography - methods</subject><subject>Female</subject><subject>Fetal Heart Rate monitoring</subject><subject>Fetal Monitoring - methods</subject><subject>Heart Rate, Fetal</subject><subject>Humans</subject><subject>Machine Learning</subject><subject>Machine learning and statistical models</subject><subject>Multivariate analysis</subject><subject>Physiology-based features</subject><subject>Predictive analytics</subject><subject>Pregnancy</subject><subject>Reproducibility of Results</subject><subject>Systems Integration</subject><issn>0169-2607</issn><issn>1872-7565</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kEtr3DAUhUVoSSaPP5BF0LIbT_WwJBu6CSFpAoFu2rWQ5esZDbbkSnJg_n1lJsmyqwvnfufAOQjdUrKlhMrvh62d5m7LCG2LIAgVZ2hDG8UqJaT4gjYFaismibpAlykdCCFMCHmOLjiVqlFtvUHzi8-wiyY7v8OTsXvnAY9gol-FDHbv3d8FEja-x_P-mFwYw-6IO5Ogx_sCZlzcgAcweYkFHEIscIa5vJap6NmMeAre5RBL5jX6Opgxwc37vUJ_nh5_PzxXr79-vjzcv1a2JiRXUtRAhKBykESoupSzTdspWyveMAOEKT50jRDc0JYaSXvOSa84HVomato1_Ap9O-XOMawFsp5csjCOxkNYkmac0pZJRuuCshNqY0gpwqDn6CYTj5oSvS6tD3pdWq9L69PSxXT3nr90E_Sflo9pC_DjBEBp-eYg6mQdeAu9i2Cz7oP7X_4_x8yPvw</recordid><startdate>202003</startdate><enddate>202003</enddate><creator>Signorini, Maria G.</creator><creator>Pini, Nicolò</creator><creator>Malovini, Alberto</creator><creator>Bellazzi, Riccardo</creator><creator>Magenes, Giovanni</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202003</creationdate><title>Integrating machine learning techniques and physiology based heart rate features for antepartum fetal monitoring</title><author>Signorini, Maria G. ; Pini, Nicolò ; Malovini, Alberto ; Bellazzi, Riccardo ; Magenes, Giovanni</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c400t-654e05516f60574501c89b7c47382ae0273fb8553a191a61d330d731f92541b83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Cardiotocography - methods</topic><topic>Female</topic><topic>Fetal Heart Rate monitoring</topic><topic>Fetal Monitoring - methods</topic><topic>Heart Rate, Fetal</topic><topic>Humans</topic><topic>Machine Learning</topic><topic>Machine learning and statistical models</topic><topic>Multivariate analysis</topic><topic>Physiology-based features</topic><topic>Predictive analytics</topic><topic>Pregnancy</topic><topic>Reproducibility of Results</topic><topic>Systems Integration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Signorini, Maria G.</creatorcontrib><creatorcontrib>Pini, Nicolò</creatorcontrib><creatorcontrib>Malovini, Alberto</creatorcontrib><creatorcontrib>Bellazzi, Riccardo</creatorcontrib><creatorcontrib>Magenes, Giovanni</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Computer methods and programs in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Signorini, Maria G.</au><au>Pini, Nicolò</au><au>Malovini, Alberto</au><au>Bellazzi, Riccardo</au><au>Magenes, Giovanni</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Integrating machine learning techniques and physiology based heart rate features for antepartum fetal monitoring</atitle><jtitle>Computer methods and programs in biomedicine</jtitle><addtitle>Comput Methods Programs Biomed</addtitle><date>2020-03</date><risdate>2020</risdate><volume>185</volume><spage>105015</spage><epage>105015</epage><pages>105015-105015</pages><artnum>105015</artnum><issn>0169-2607</issn><eissn>1872-7565</eissn><abstract>[Display omitted] Intrauterine Growth Restriction (IUGR) is a fetal condition defined as the abnormal rate of fetal growth. The pathology is a documented cause of fetal and neonatal morbidity and mortality. In clinical practice, diagnosis is confirmed at birth and may only be suspected during pregnancy. Therefore, designing an accurate model for the early and prompt identification of pathology in the antepartum period is crucial in view of pregnancy management. We tested the performance of 15 machine learning techniques in discriminating healthy versus IUGR fetuses. The various models were trained with a set of 12 physiology based heart rate features extracted from a single antepartum CardioTocographic (CTG) recording. The reason for the utilization of time, frequency, and nonlinear indices is based on their standalone documented ability to describe several physiological and pathological fetal conditions. We validated our approach on a database of 60 healthy and 60 IUGR fetuses. The machine learning methodology achieving the best performance was Random Forests. Specifically, we obtained a mean classification accuracy of 0.911 [0.860, 0.961 (0.95 confidence interval)] averaged over 10 test sets (10 Fold Cross Validation). Similar results were provided by Classification Trees, Logistic Regression, and Support Vector Machines. A features ranking procedure highlighted that nonlinear indices showed the highest capability to discriminate between the considered fetal conditions. Nevertheless, is the combination of features investigating CTG signal in different domains, that contributes to an increase in classification accuracy. We provided validation of an accurate artificially intelligence framework for the diagnosis of IUGR condition in the antepartum period. The employed physiology based heart rate features constitute an interpretable link between the machine learning results and the quantitative estimators of fetal wellbeing.</abstract><cop>Ireland</cop><pub>Elsevier B.V</pub><pmid>31678794</pmid><doi>10.1016/j.cmpb.2019.105015</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0169-2607
ispartof Computer methods and programs in biomedicine, 2020-03, Vol.185, p.105015-105015, Article 105015
issn 0169-2607
1872-7565
language eng
recordid cdi_proquest_miscellaneous_2311926214
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Cardiotocography - methods
Female
Fetal Heart Rate monitoring
Fetal Monitoring - methods
Heart Rate, Fetal
Humans
Machine Learning
Machine learning and statistical models
Multivariate analysis
Physiology-based features
Predictive analytics
Pregnancy
Reproducibility of Results
Systems Integration
title Integrating machine learning techniques and physiology based heart rate features for antepartum fetal monitoring
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T08%3A57%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Integrating%20machine%20learning%20techniques%20and%20physiology%20based%20heart%20rate%20features%20for%20antepartum%20fetal%20monitoring&rft.jtitle=Computer%20methods%20and%20programs%20in%20biomedicine&rft.au=Signorini,%20Maria%20G.&rft.date=2020-03&rft.volume=185&rft.spage=105015&rft.epage=105015&rft.pages=105015-105015&rft.artnum=105015&rft.issn=0169-2607&rft.eissn=1872-7565&rft_id=info:doi/10.1016/j.cmpb.2019.105015&rft_dat=%3Cproquest_cross%3E2311926214%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2311926214&rft_id=info:pmid/31678794&rft_els_id=S0169260719308107&rfr_iscdi=true