Dose coefficients of percentile-specific computational phantoms for photon external exposures
The use of dose coefficients (DCs) based on the reference phantoms recommended by the International Commission on Radiological Protection (ICRP) with a fixed body size may produce errors to the estimated organ/tissue doses to be used, for example, for epidemiologic studies depending on the body size...
Gespeichert in:
Veröffentlicht in: | Radiation and environmental biophysics 2020-03, Vol.59 (1), p.151-160 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 160 |
---|---|
container_issue | 1 |
container_start_page | 151 |
container_title | Radiation and environmental biophysics |
container_volume | 59 |
creator | Yeom, Yeon Soo Han, Haegin Choi, Chansoo Shin, Bangho Kim, Chan Hyeong Lee, Choonsik |
description | The use of dose coefficients (DCs) based on the reference phantoms recommended by the International Commission on Radiological Protection (ICRP) with a fixed body size may produce errors to the estimated organ/tissue doses to be used, for example, for epidemiologic studies depending on the body size of cohort members. A set of percentile-specific computational phantoms that represent 10th, 50th, and 90th percentile standing heights and body masses in adult male and female Caucasian populations were recently developed by modifying the mesh-type ICRP reference computational phantoms (MRCPs). In the present study, these percentile-specific phantoms were used to calculate a comprehensive dataset of body-size-dependent DCs for photon external exposures by performing Monte Carlo dose calculations with the Geant4 code. The dataset includes the DCs of absorbed doses for 29 individual organs/tissues from 0.01 to 10
4
MeV photon energy, in the antero-posterior, postero-anterior, right lateral, left lateral, rotational, and isotropic geometries. The body-size-dependent DCs were compared with the DCs of the MRCPs in the reference body size, showing that the DCs of the MRCPs are generally similar to those of the 50th percentile standing height and body mass phantoms over the entire photon energy region except for low energies (≤ 0.03 MeV); the differences are mostly less than 10%. In contrast, there are significant differences in the DCs between the MRCPs and the 10th and 90th percentile standing height and body mass phantoms (i.e., H10M10 and H90M90). At energies of less than about 10 MeV, the MRCPs tended to under- and over-estimate the organ/tissue doses of the H10M10 and H90M90 phantoms, respectively. This tendency was revised at higher energies. The DCs of the percentile-specific phantoms were also compared with the previously published values of another phantom sets with similar body sizes, showing significant differences particularly at energies below about 0.1 MeV, which is mainly due to the different locations and depths of organs/tissues between the different phantom libraries. The DCs established in the present study should be useful to improve the dosimetric accuracy in the reconstructions of organ/tissue doses for individuals in risk assessment for epidemiologic investigations taking body sizes into account. |
doi_str_mv | 10.1007/s00411-019-00818-w |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2311922998</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2311922998</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-e6275a963d37f1cbcd6153d25d9afdcf5816ab4e6ba0e08c27897b24b4be56233</originalsourceid><addsrcrecordid>eNp9kMFK5TAUhoOM6B31BWYhhdm4iZ4kTdosxRlnBMGNghsJaXriVNqmJi3q25s71xnBhask_N_5T_gI-cbgmAFUJwmgZIwC0xSgZjV92iIrVgpOOWj9haxAAKNKlLe75GtKDwCsUkrvkF3BVKWhlCty9yMkLFxA7zvX4TinIvhiwujyveuRpgldl7PMDNMy27kLo-2L6Y8d5zCkwoeYH2EOY4HPM8Z1iM9TSEvEtE-2ve0THryde-Tm_Of12W96efXr4uz0kjpRyZmi4pW0WolWVJ65xrWKSdFy2WrrW-dlzZRtSlSNBYTa8arWVcPLpmxQKi7EHjna9E4xPC6YZjN0yWHf2xHDkgwXjGnOta4z-v0D-hCW9a_XlBRCSVGXmeIbysWQUkRvptgNNr4YBmYt32zkmyzf_JVvnvLQ4Vv10gzY_h_5ZzsDYgOkHI33GN93f1L7Cp6gkaQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2353365384</pqid></control><display><type>article</type><title>Dose coefficients of percentile-specific computational phantoms for photon external exposures</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Yeom, Yeon Soo ; Han, Haegin ; Choi, Chansoo ; Shin, Bangho ; Kim, Chan Hyeong ; Lee, Choonsik</creator><creatorcontrib>Yeom, Yeon Soo ; Han, Haegin ; Choi, Chansoo ; Shin, Bangho ; Kim, Chan Hyeong ; Lee, Choonsik</creatorcontrib><description>The use of dose coefficients (DCs) based on the reference phantoms recommended by the International Commission on Radiological Protection (ICRP) with a fixed body size may produce errors to the estimated organ/tissue doses to be used, for example, for epidemiologic studies depending on the body size of cohort members. A set of percentile-specific computational phantoms that represent 10th, 50th, and 90th percentile standing heights and body masses in adult male and female Caucasian populations were recently developed by modifying the mesh-type ICRP reference computational phantoms (MRCPs). In the present study, these percentile-specific phantoms were used to calculate a comprehensive dataset of body-size-dependent DCs for photon external exposures by performing Monte Carlo dose calculations with the Geant4 code. The dataset includes the DCs of absorbed doses for 29 individual organs/tissues from 0.01 to 10
4
MeV photon energy, in the antero-posterior, postero-anterior, right lateral, left lateral, rotational, and isotropic geometries. The body-size-dependent DCs were compared with the DCs of the MRCPs in the reference body size, showing that the DCs of the MRCPs are generally similar to those of the 50th percentile standing height and body mass phantoms over the entire photon energy region except for low energies (≤ 0.03 MeV); the differences are mostly less than 10%. In contrast, there are significant differences in the DCs between the MRCPs and the 10th and 90th percentile standing height and body mass phantoms (i.e., H10M10 and H90M90). At energies of less than about 10 MeV, the MRCPs tended to under- and over-estimate the organ/tissue doses of the H10M10 and H90M90 phantoms, respectively. This tendency was revised at higher energies. The DCs of the percentile-specific phantoms were also compared with the previously published values of another phantom sets with similar body sizes, showing significant differences particularly at energies below about 0.1 MeV, which is mainly due to the different locations and depths of organs/tissues between the different phantom libraries. The DCs established in the present study should be useful to improve the dosimetric accuracy in the reconstructions of organ/tissue doses for individuals in risk assessment for epidemiologic investigations taking body sizes into account.</description><identifier>ISSN: 0301-634X</identifier><identifier>ISSN: 1432-2099</identifier><identifier>EISSN: 1432-2099</identifier><identifier>DOI: 10.1007/s00411-019-00818-w</identifier><identifier>PMID: 31679045</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Adult ; Biological and Medical Physics ; Biophysics ; Body mass ; Body Size ; Computer applications ; Datasets ; Dosimetry ; Ecosystems ; Effects of Radiation/Radiation Protection ; Environmental Physics ; Epidemiology ; Female ; Humans ; Male ; Mathematical analysis ; Monitoring/Environmental Analysis ; Monte Carlo Method ; Organs ; Original Article ; Phantoms, Imaging ; Photons ; Physics ; Physics and Astronomy ; Radiation Dosage ; Risk assessment ; Tissues</subject><ispartof>Radiation and environmental biophysics, 2020-03, Vol.59 (1), p.151-160</ispartof><rights>Springer-Verlag GmbH Germany, part of Springer Nature 2019</rights><rights>Radiation and Environmental Biophysics is a copyright of Springer, (2019). All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-e6275a963d37f1cbcd6153d25d9afdcf5816ab4e6ba0e08c27897b24b4be56233</citedby><cites>FETCH-LOGICAL-c375t-e6275a963d37f1cbcd6153d25d9afdcf5816ab4e6ba0e08c27897b24b4be56233</cites><orcidid>0000-0001-5373-6693</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00411-019-00818-w$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00411-019-00818-w$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27915,27916,41479,42548,51310</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31679045$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yeom, Yeon Soo</creatorcontrib><creatorcontrib>Han, Haegin</creatorcontrib><creatorcontrib>Choi, Chansoo</creatorcontrib><creatorcontrib>Shin, Bangho</creatorcontrib><creatorcontrib>Kim, Chan Hyeong</creatorcontrib><creatorcontrib>Lee, Choonsik</creatorcontrib><title>Dose coefficients of percentile-specific computational phantoms for photon external exposures</title><title>Radiation and environmental biophysics</title><addtitle>Radiat Environ Biophys</addtitle><addtitle>Radiat Environ Biophys</addtitle><description>The use of dose coefficients (DCs) based on the reference phantoms recommended by the International Commission on Radiological Protection (ICRP) with a fixed body size may produce errors to the estimated organ/tissue doses to be used, for example, for epidemiologic studies depending on the body size of cohort members. A set of percentile-specific computational phantoms that represent 10th, 50th, and 90th percentile standing heights and body masses in adult male and female Caucasian populations were recently developed by modifying the mesh-type ICRP reference computational phantoms (MRCPs). In the present study, these percentile-specific phantoms were used to calculate a comprehensive dataset of body-size-dependent DCs for photon external exposures by performing Monte Carlo dose calculations with the Geant4 code. The dataset includes the DCs of absorbed doses for 29 individual organs/tissues from 0.01 to 10
4
MeV photon energy, in the antero-posterior, postero-anterior, right lateral, left lateral, rotational, and isotropic geometries. The body-size-dependent DCs were compared with the DCs of the MRCPs in the reference body size, showing that the DCs of the MRCPs are generally similar to those of the 50th percentile standing height and body mass phantoms over the entire photon energy region except for low energies (≤ 0.03 MeV); the differences are mostly less than 10%. In contrast, there are significant differences in the DCs between the MRCPs and the 10th and 90th percentile standing height and body mass phantoms (i.e., H10M10 and H90M90). At energies of less than about 10 MeV, the MRCPs tended to under- and over-estimate the organ/tissue doses of the H10M10 and H90M90 phantoms, respectively. This tendency was revised at higher energies. The DCs of the percentile-specific phantoms were also compared with the previously published values of another phantom sets with similar body sizes, showing significant differences particularly at energies below about 0.1 MeV, which is mainly due to the different locations and depths of organs/tissues between the different phantom libraries. The DCs established in the present study should be useful to improve the dosimetric accuracy in the reconstructions of organ/tissue doses for individuals in risk assessment for epidemiologic investigations taking body sizes into account.</description><subject>Adult</subject><subject>Biological and Medical Physics</subject><subject>Biophysics</subject><subject>Body mass</subject><subject>Body Size</subject><subject>Computer applications</subject><subject>Datasets</subject><subject>Dosimetry</subject><subject>Ecosystems</subject><subject>Effects of Radiation/Radiation Protection</subject><subject>Environmental Physics</subject><subject>Epidemiology</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Mathematical analysis</subject><subject>Monitoring/Environmental Analysis</subject><subject>Monte Carlo Method</subject><subject>Organs</subject><subject>Original Article</subject><subject>Phantoms, Imaging</subject><subject>Photons</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><subject>Radiation Dosage</subject><subject>Risk assessment</subject><subject>Tissues</subject><issn>0301-634X</issn><issn>1432-2099</issn><issn>1432-2099</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNp9kMFK5TAUhoOM6B31BWYhhdm4iZ4kTdosxRlnBMGNghsJaXriVNqmJi3q25s71xnBhask_N_5T_gI-cbgmAFUJwmgZIwC0xSgZjV92iIrVgpOOWj9haxAAKNKlLe75GtKDwCsUkrvkF3BVKWhlCty9yMkLFxA7zvX4TinIvhiwujyveuRpgldl7PMDNMy27kLo-2L6Y8d5zCkwoeYH2EOY4HPM8Z1iM9TSEvEtE-2ve0THryde-Tm_Of12W96efXr4uz0kjpRyZmi4pW0WolWVJ65xrWKSdFy2WrrW-dlzZRtSlSNBYTa8arWVcPLpmxQKi7EHjna9E4xPC6YZjN0yWHf2xHDkgwXjGnOta4z-v0D-hCW9a_XlBRCSVGXmeIbysWQUkRvptgNNr4YBmYt32zkmyzf_JVvnvLQ4Vv10gzY_h_5ZzsDYgOkHI33GN93f1L7Cp6gkaQ</recordid><startdate>20200301</startdate><enddate>20200301</enddate><creator>Yeom, Yeon Soo</creator><creator>Han, Haegin</creator><creator>Choi, Chansoo</creator><creator>Shin, Bangho</creator><creator>Kim, Chan Hyeong</creator><creator>Lee, Choonsik</creator><general>Springer Berlin Heidelberg</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7ST</scope><scope>7TK</scope><scope>7TM</scope><scope>7U7</scope><scope>7X7</scope><scope>7XB</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8AO</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>PATMY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PYCSY</scope><scope>Q9U</scope><scope>SOI</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5373-6693</orcidid></search><sort><creationdate>20200301</creationdate><title>Dose coefficients of percentile-specific computational phantoms for photon external exposures</title><author>Yeom, Yeon Soo ; Han, Haegin ; Choi, Chansoo ; Shin, Bangho ; Kim, Chan Hyeong ; Lee, Choonsik</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-e6275a963d37f1cbcd6153d25d9afdcf5816ab4e6ba0e08c27897b24b4be56233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Adult</topic><topic>Biological and Medical Physics</topic><topic>Biophysics</topic><topic>Body mass</topic><topic>Body Size</topic><topic>Computer applications</topic><topic>Datasets</topic><topic>Dosimetry</topic><topic>Ecosystems</topic><topic>Effects of Radiation/Radiation Protection</topic><topic>Environmental Physics</topic><topic>Epidemiology</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Mathematical analysis</topic><topic>Monitoring/Environmental Analysis</topic><topic>Monte Carlo Method</topic><topic>Organs</topic><topic>Original Article</topic><topic>Phantoms, Imaging</topic><topic>Photons</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><topic>Radiation Dosage</topic><topic>Risk assessment</topic><topic>Tissues</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yeom, Yeon Soo</creatorcontrib><creatorcontrib>Han, Haegin</creatorcontrib><creatorcontrib>Choi, Chansoo</creatorcontrib><creatorcontrib>Shin, Bangho</creatorcontrib><creatorcontrib>Kim, Chan Hyeong</creatorcontrib><creatorcontrib>Lee, Choonsik</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Environment Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Health Medical collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central</collection><collection>Agricultural & Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Biological Sciences</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>ProQuest Science Journals</collection><collection>ProQuest Biological Science Journals</collection><collection>Environmental Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Environmental Science Collection</collection><collection>ProQuest Central Basic</collection><collection>Environment Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Radiation and environmental biophysics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yeom, Yeon Soo</au><au>Han, Haegin</au><au>Choi, Chansoo</au><au>Shin, Bangho</au><au>Kim, Chan Hyeong</au><au>Lee, Choonsik</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dose coefficients of percentile-specific computational phantoms for photon external exposures</atitle><jtitle>Radiation and environmental biophysics</jtitle><stitle>Radiat Environ Biophys</stitle><addtitle>Radiat Environ Biophys</addtitle><date>2020-03-01</date><risdate>2020</risdate><volume>59</volume><issue>1</issue><spage>151</spage><epage>160</epage><pages>151-160</pages><issn>0301-634X</issn><issn>1432-2099</issn><eissn>1432-2099</eissn><abstract>The use of dose coefficients (DCs) based on the reference phantoms recommended by the International Commission on Radiological Protection (ICRP) with a fixed body size may produce errors to the estimated organ/tissue doses to be used, for example, for epidemiologic studies depending on the body size of cohort members. A set of percentile-specific computational phantoms that represent 10th, 50th, and 90th percentile standing heights and body masses in adult male and female Caucasian populations were recently developed by modifying the mesh-type ICRP reference computational phantoms (MRCPs). In the present study, these percentile-specific phantoms were used to calculate a comprehensive dataset of body-size-dependent DCs for photon external exposures by performing Monte Carlo dose calculations with the Geant4 code. The dataset includes the DCs of absorbed doses for 29 individual organs/tissues from 0.01 to 10
4
MeV photon energy, in the antero-posterior, postero-anterior, right lateral, left lateral, rotational, and isotropic geometries. The body-size-dependent DCs were compared with the DCs of the MRCPs in the reference body size, showing that the DCs of the MRCPs are generally similar to those of the 50th percentile standing height and body mass phantoms over the entire photon energy region except for low energies (≤ 0.03 MeV); the differences are mostly less than 10%. In contrast, there are significant differences in the DCs between the MRCPs and the 10th and 90th percentile standing height and body mass phantoms (i.e., H10M10 and H90M90). At energies of less than about 10 MeV, the MRCPs tended to under- and over-estimate the organ/tissue doses of the H10M10 and H90M90 phantoms, respectively. This tendency was revised at higher energies. The DCs of the percentile-specific phantoms were also compared with the previously published values of another phantom sets with similar body sizes, showing significant differences particularly at energies below about 0.1 MeV, which is mainly due to the different locations and depths of organs/tissues between the different phantom libraries. The DCs established in the present study should be useful to improve the dosimetric accuracy in the reconstructions of organ/tissue doses for individuals in risk assessment for epidemiologic investigations taking body sizes into account.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>31679045</pmid><doi>10.1007/s00411-019-00818-w</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0001-5373-6693</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0301-634X |
ispartof | Radiation and environmental biophysics, 2020-03, Vol.59 (1), p.151-160 |
issn | 0301-634X 1432-2099 1432-2099 |
language | eng |
recordid | cdi_proquest_miscellaneous_2311922998 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Adult Biological and Medical Physics Biophysics Body mass Body Size Computer applications Datasets Dosimetry Ecosystems Effects of Radiation/Radiation Protection Environmental Physics Epidemiology Female Humans Male Mathematical analysis Monitoring/Environmental Analysis Monte Carlo Method Organs Original Article Phantoms, Imaging Photons Physics Physics and Astronomy Radiation Dosage Risk assessment Tissues |
title | Dose coefficients of percentile-specific computational phantoms for photon external exposures |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T18%3A38%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dose%20coefficients%20of%20percentile-specific%20computational%20phantoms%20for%20photon%20external%20exposures&rft.jtitle=Radiation%20and%20environmental%20biophysics&rft.au=Yeom,%20Yeon%20Soo&rft.date=2020-03-01&rft.volume=59&rft.issue=1&rft.spage=151&rft.epage=160&rft.pages=151-160&rft.issn=0301-634X&rft.eissn=1432-2099&rft_id=info:doi/10.1007/s00411-019-00818-w&rft_dat=%3Cproquest_cross%3E2311922998%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2353365384&rft_id=info:pmid/31679045&rfr_iscdi=true |