A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells
To measure [Ca2+] quantitatively, fura-2 analogs, which are ratiometric fluoroprobes, are frequently used. However, dye usage is intrinsically limited in live cells because of autofluorescence interference, mainly from nicotinamide adenine dinucleotide (NADH). More specifically, this is a major obst...
Gespeichert in:
Veröffentlicht in: | Journal of Visualized Experiments 2019-09 (151) |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 151 |
container_start_page | |
container_title | Journal of Visualized Experiments |
container_volume | |
creator | Lee, Jeong Hoon Ha, Jeong Mi Ho, Quynh Mai Leem, Chae Hun |
description | To measure [Ca2+] quantitatively, fura-2 analogs, which are ratiometric fluoroprobes, are frequently used. However, dye usage is intrinsically limited in live cells because of autofluorescence interference, mainly from nicotinamide adenine dinucleotide (NADH). More specifically, this is a major obstacle when measuring the mitochondrial [Ca2+] quantitatively using fura-2 analogs because the majority of NADH is in the mitochondria. If the fluorescent dye concentration is the same, a certain excitation intensity should produce the same emission intensity. Therefore, the emission intensity ratio of two different excitation wavelengths should be constant. Based on this principle, a novel online correction method of NADH signal interference to measure [Ca2+] was developed, and the real signal intensity of NADH and fura-2 can be obtained. Further, a novel equation to calculate [Ca2+] was developed with isosbestic excitation or excitation at 400 nm. With this method, changes in mitochondrial [Ca2+] could be successfully measured. In addition, with a different set of the excitation and emission wavelengths, multiple parameters, including NADH, [Ca2+], and pH or mitochondrial membrane potential (Ψm), could be simultaneously measured. Mitochondrial [Ca2+] and Ψm or pH were measured using fura-2-FF and tetramethylrhodamine ethyl ester (TMRE) or carboxy-seminaphtorhodafluor-1 (carboxy-SNARF-1). |
doi_str_mv | 10.3791/59881 |
format | Article |
fullrecord | <record><control><sourceid>proquest_223</sourceid><recordid>TN_cdi_proquest_miscellaneous_2301881139</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2301881139</sourcerecordid><originalsourceid>FETCH-LOGICAL-c190t-98bd60398083ca8ad9a9f4432db69bd125e91a259ffa810108517c6e713532543</originalsourceid><addsrcrecordid>eNpNkE1LAzEQhoMottb-AQ-SiyDIarLZj-RYVquFWi8K3pbs7qxN2U1qslvx5F83tVU8zTDzzMvwIDSm5Jqlgt7EgnN6gIZURCQgPH09_NcP0IlzK0KSkMT8GA0Yjbnw_RB9TfDCbKDBC1WaTmnZqgrwpAKtNOBbpfuyAb_ww8xYC2WnjMaP0C1NhWtj8Ux3VpbQNH0jLc5keOW30vUWWtAd_lDdEk97K4MwmGjZmDesNJ6rjc_zR-4UHdWycTDe1xF6md49Zw_B_Ol-lk3mQUkF6QLBiyohTHDCWSm5rIQUdRSxsCoSUVQ0jEFQGcairiWnhBIe07RMIKUsZmEcsRG63OWurXnvwXV5q9z2banB9C4PGaFeIGXCoxc7tLTGOQt1vraqlfYzpyTfus5_XHvufB_ZFy1Uf9SvXA-c7YCVN5yvTG-9ALe__gYPwYCe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2301881139</pqid></control><display><type>article</type><title>A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells</title><source>Journal of Visualized Experiments : JoVE</source><creator>Lee, Jeong Hoon ; Ha, Jeong Mi ; Ho, Quynh Mai ; Leem, Chae Hun</creator><creatorcontrib>Lee, Jeong Hoon ; Ha, Jeong Mi ; Ho, Quynh Mai ; Leem, Chae Hun</creatorcontrib><description>To measure [Ca2+] quantitatively, fura-2 analogs, which are ratiometric fluoroprobes, are frequently used. However, dye usage is intrinsically limited in live cells because of autofluorescence interference, mainly from nicotinamide adenine dinucleotide (NADH). More specifically, this is a major obstacle when measuring the mitochondrial [Ca2+] quantitatively using fura-2 analogs because the majority of NADH is in the mitochondria. If the fluorescent dye concentration is the same, a certain excitation intensity should produce the same emission intensity. Therefore, the emission intensity ratio of two different excitation wavelengths should be constant. Based on this principle, a novel online correction method of NADH signal interference to measure [Ca2+] was developed, and the real signal intensity of NADH and fura-2 can be obtained. Further, a novel equation to calculate [Ca2+] was developed with isosbestic excitation or excitation at 400 nm. With this method, changes in mitochondrial [Ca2+] could be successfully measured. In addition, with a different set of the excitation and emission wavelengths, multiple parameters, including NADH, [Ca2+], and pH or mitochondrial membrane potential (Ψm), could be simultaneously measured. Mitochondrial [Ca2+] and Ψm or pH were measured using fura-2-FF and tetramethylrhodamine ethyl ester (TMRE) or carboxy-seminaphtorhodafluor-1 (carboxy-SNARF-1).</description><identifier>ISSN: 1940-087X</identifier><identifier>EISSN: 1940-087X</identifier><identifier>DOI: 10.3791/59881</identifier><identifier>PMID: 31589205</identifier><language>eng</language><publisher>United States: MyJove Corporation</publisher><subject>Biology</subject><ispartof>Journal of Visualized Experiments, 2019-09 (151)</ispartof><rights>Copyright © 2019, Journal of Visualized Experiments</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.jove.com/files/email_thumbs/59881.png</thumbnail><link.rule.ids>314,776,780,3830,27901,27902</link.rule.ids><linktorsrc>$$Uhttp://dx.doi.org/10.3791/59881$$EView_record_in_Journal_of_Visualized_Experiments$$FView_record_in_$$GJournal_of_Visualized_Experiments</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31589205$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lee, Jeong Hoon</creatorcontrib><creatorcontrib>Ha, Jeong Mi</creatorcontrib><creatorcontrib>Ho, Quynh Mai</creatorcontrib><creatorcontrib>Leem, Chae Hun</creatorcontrib><title>A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells</title><title>Journal of Visualized Experiments</title><addtitle>J Vis Exp</addtitle><description>To measure [Ca2+] quantitatively, fura-2 analogs, which are ratiometric fluoroprobes, are frequently used. However, dye usage is intrinsically limited in live cells because of autofluorescence interference, mainly from nicotinamide adenine dinucleotide (NADH). More specifically, this is a major obstacle when measuring the mitochondrial [Ca2+] quantitatively using fura-2 analogs because the majority of NADH is in the mitochondria. If the fluorescent dye concentration is the same, a certain excitation intensity should produce the same emission intensity. Therefore, the emission intensity ratio of two different excitation wavelengths should be constant. Based on this principle, a novel online correction method of NADH signal interference to measure [Ca2+] was developed, and the real signal intensity of NADH and fura-2 can be obtained. Further, a novel equation to calculate [Ca2+] was developed with isosbestic excitation or excitation at 400 nm. With this method, changes in mitochondrial [Ca2+] could be successfully measured. In addition, with a different set of the excitation and emission wavelengths, multiple parameters, including NADH, [Ca2+], and pH or mitochondrial membrane potential (Ψm), could be simultaneously measured. Mitochondrial [Ca2+] and Ψm or pH were measured using fura-2-FF and tetramethylrhodamine ethyl ester (TMRE) or carboxy-seminaphtorhodafluor-1 (carboxy-SNARF-1).</description><subject>Biology</subject><issn>1940-087X</issn><issn>1940-087X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpNkE1LAzEQhoMottb-AQ-SiyDIarLZj-RYVquFWi8K3pbs7qxN2U1qslvx5F83tVU8zTDzzMvwIDSm5Jqlgt7EgnN6gIZURCQgPH09_NcP0IlzK0KSkMT8GA0Yjbnw_RB9TfDCbKDBC1WaTmnZqgrwpAKtNOBbpfuyAb_ww8xYC2WnjMaP0C1NhWtj8Ux3VpbQNH0jLc5keOW30vUWWtAd_lDdEk97K4MwmGjZmDesNJ6rjc_zR-4UHdWycTDe1xF6md49Zw_B_Ol-lk3mQUkF6QLBiyohTHDCWSm5rIQUdRSxsCoSUVQ0jEFQGcairiWnhBIe07RMIKUsZmEcsRG63OWurXnvwXV5q9z2banB9C4PGaFeIGXCoxc7tLTGOQt1vraqlfYzpyTfus5_XHvufB_ZFy1Uf9SvXA-c7YCVN5yvTG-9ALe__gYPwYCe</recordid><startdate>20190920</startdate><enddate>20190920</enddate><creator>Lee, Jeong Hoon</creator><creator>Ha, Jeong Mi</creator><creator>Ho, Quynh Mai</creator><creator>Leem, Chae Hun</creator><general>MyJove Corporation</general><scope>ALOKQ</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20190920</creationdate><title>A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells</title><author>Lee, Jeong Hoon ; Ha, Jeong Mi ; Ho, Quynh Mai ; Leem, Chae Hun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c190t-98bd60398083ca8ad9a9f4432db69bd125e91a259ffa810108517c6e713532543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Biology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lee, Jeong Hoon</creatorcontrib><creatorcontrib>Ha, Jeong Mi</creatorcontrib><creatorcontrib>Ho, Quynh Mai</creatorcontrib><creatorcontrib>Leem, Chae Hun</creatorcontrib><collection>JoVE Journal: Biology</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Visualized Experiments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Lee, Jeong Hoon</au><au>Ha, Jeong Mi</au><au>Ho, Quynh Mai</au><au>Leem, Chae Hun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells</atitle><jtitle>Journal of Visualized Experiments</jtitle><addtitle>J Vis Exp</addtitle><date>2019-09-20</date><risdate>2019</risdate><issue>151</issue><issn>1940-087X</issn><eissn>1940-087X</eissn><abstract>To measure [Ca2+] quantitatively, fura-2 analogs, which are ratiometric fluoroprobes, are frequently used. However, dye usage is intrinsically limited in live cells because of autofluorescence interference, mainly from nicotinamide adenine dinucleotide (NADH). More specifically, this is a major obstacle when measuring the mitochondrial [Ca2+] quantitatively using fura-2 analogs because the majority of NADH is in the mitochondria. If the fluorescent dye concentration is the same, a certain excitation intensity should produce the same emission intensity. Therefore, the emission intensity ratio of two different excitation wavelengths should be constant. Based on this principle, a novel online correction method of NADH signal interference to measure [Ca2+] was developed, and the real signal intensity of NADH and fura-2 can be obtained. Further, a novel equation to calculate [Ca2+] was developed with isosbestic excitation or excitation at 400 nm. With this method, changes in mitochondrial [Ca2+] could be successfully measured. In addition, with a different set of the excitation and emission wavelengths, multiple parameters, including NADH, [Ca2+], and pH or mitochondrial membrane potential (Ψm), could be simultaneously measured. Mitochondrial [Ca2+] and Ψm or pH were measured using fura-2-FF and tetramethylrhodamine ethyl ester (TMRE) or carboxy-seminaphtorhodafluor-1 (carboxy-SNARF-1).</abstract><cop>United States</cop><pub>MyJove Corporation</pub><pmid>31589205</pmid><doi>10.3791/59881</doi></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1940-087X |
ispartof | Journal of Visualized Experiments, 2019-09 (151) |
issn | 1940-087X 1940-087X |
language | eng |
recordid | cdi_proquest_miscellaneous_2301881139 |
source | Journal of Visualized Experiments : JoVE |
subjects | Biology |
title | A Novel Nicotinamide Adenine Dinucleotide Correction Method for Intracellular Ca2+ Measurement with Fura-2-Analog in Live Cells |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T01%3A11%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_223&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Novel%20Nicotinamide%20Adenine%20Dinucleotide%20Correction%20Method%20for%20Intracellular%20Ca2+%20Measurement%20with%20Fura-2-Analog%20in%20Live%20Cells&rft.jtitle=Journal%20of%20Visualized%20Experiments&rft.au=Lee,%20Jeong%20Hoon&rft.date=2019-09-20&rft.issue=151&rft.issn=1940-087X&rft.eissn=1940-087X&rft_id=info:doi/10.3791/59881&rft_dat=%3Cproquest_223%3E2301881139%3C/proquest_223%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2301881139&rft_id=info:pmid/31589205&rfr_iscdi=true |