Computed Tomography (CT)-Guided Percutaneous Thoracic Sympathetic Chain Radiofrequency Thermocoagulation for Raynaud Disease
BACKGROUND We introduce a minimally invasive technique for the treatment of Raynaud disease - CT-guided percutaneous thoracic sympathetic chain radiofrequency thermocoagulation. MATERIAL AND METHODS Under CT guidance, the radiofrequency needle was punctured from the upper edge of the costotransverse...
Gespeichert in:
Veröffentlicht in: | Medical science monitor 2019-10, Vol.25, p.7391-7395 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 7395 |
---|---|
container_issue | |
container_start_page | 7391 |
container_title | Medical science monitor |
container_volume | 25 |
creator | Huang, Hao Qiu, Weidong Chen, Qunshan Sun, Kai Huang, Bing |
description | BACKGROUND We introduce a minimally invasive technique for the treatment of Raynaud disease - CT-guided percutaneous thoracic sympathetic chain radiofrequency thermocoagulation. MATERIAL AND METHODS Under CT guidance, the radiofrequency needle was punctured from the upper edge of the costotransverse joint to the anterior superior edge of the 4th capitulum costae and the lateral parietal pleura. After sensorial (1.5 mA, 50 Hz) and motorial (1.5 mA, 2Hz) testing to determine that there was no nerve innervation zone with muscle numbness and twitches, radiofrequency coagulation was set at 95°C for 300 s. RESULTS A total of 17 patients were enrolled in the treatment group. All the patients underwent CT-guided percutaneous thoracic sympathetic chain puncture of the needles to the upper edge of the 4th capitulum costae on both sides. The perfusion index (PI) of the fingers began to rise 30 s after radiofrequency thermocoagulation, and the palm temperature (T) began to rise after 90 s. At the end of treatment, PI increased by an average of 4.6-fold, and the T average rose by 3.6°C. Postoperative cold-water stimulation testing could no longer induce Raynaud disease. Follow-up was conducted for 1 to 15 months. Two patients were found to have recurrence at 9 months and 13 months, respectively. CONCLUSIONS CT-guided percutaneous thoracic sympathetic nerve chain radiofrequency coagulation can effectively treat Raynaud disease. |
doi_str_mv | 10.12659/MSM.917392 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2300183434</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2300183434</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-4b395e609990bb9925fef9729bddc593abd1fa07a074e0a61b98f3cd57714b4b3</originalsourceid><addsrcrecordid>eNpNkE1LxDAQhoMo7rp68i49rkjXpOlXjlJ1FXZR3Hou-eo20jY1aQ8Ff7zBriIzMMPwzMvMC8AlgisUxBG53e62K4ISTIIjMEdxiH2cRPD4Xz8DZ9Z-QBikMYxOwQyjKIlThOfgK9NNN_RSeLlu9N7Qrhq9ZZZf--tBCTd-lYYPPW2lHqyXV9pQrri3G5uO9pXsXZ9VVLXeGxVKl0Z-DrLloyOlaTTXdD_UtFe69UptHDS2dBDevbKSWnkOTkpaW3lxqAvw_viQZ0_-5mX9nN1tfB6kpPdDhkkkY0gIgYwREkSlLEkSECYEjwimTKCSwsRlKCGNESNpibmIkgSFzG0vwHLS7Yx299m-aJTlsq6nt4oAQ4hSHLpYgJsJ5UZba2RZdEY11IwFgsWP3YWzu5jsdvTVQXhgjRR_7K-_-But63ya</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2300183434</pqid></control><display><type>article</type><title>Computed Tomography (CT)-Guided Percutaneous Thoracic Sympathetic Chain Radiofrequency Thermocoagulation for Raynaud Disease</title><source>MEDLINE</source><source>PubMed Central Open Access</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Huang, Hao ; Qiu, Weidong ; Chen, Qunshan ; Sun, Kai ; Huang, Bing</creator><creatorcontrib>Huang, Hao ; Qiu, Weidong ; Chen, Qunshan ; Sun, Kai ; Huang, Bing</creatorcontrib><description>BACKGROUND We introduce a minimally invasive technique for the treatment of Raynaud disease - CT-guided percutaneous thoracic sympathetic chain radiofrequency thermocoagulation. MATERIAL AND METHODS Under CT guidance, the radiofrequency needle was punctured from the upper edge of the costotransverse joint to the anterior superior edge of the 4th capitulum costae and the lateral parietal pleura. After sensorial (1.5 mA, 50 Hz) and motorial (1.5 mA, 2Hz) testing to determine that there was no nerve innervation zone with muscle numbness and twitches, radiofrequency coagulation was set at 95°C for 300 s. RESULTS A total of 17 patients were enrolled in the treatment group. All the patients underwent CT-guided percutaneous thoracic sympathetic chain puncture of the needles to the upper edge of the 4th capitulum costae on both sides. The perfusion index (PI) of the fingers began to rise 30 s after radiofrequency thermocoagulation, and the palm temperature (T) began to rise after 90 s. At the end of treatment, PI increased by an average of 4.6-fold, and the T average rose by 3.6°C. Postoperative cold-water stimulation testing could no longer induce Raynaud disease. Follow-up was conducted for 1 to 15 months. Two patients were found to have recurrence at 9 months and 13 months, respectively. CONCLUSIONS CT-guided percutaneous thoracic sympathetic nerve chain radiofrequency coagulation can effectively treat Raynaud disease.</description><identifier>ISSN: 1643-3750</identifier><identifier>EISSN: 1643-3750</identifier><identifier>DOI: 10.12659/MSM.917392</identifier><identifier>PMID: 31576813</identifier><language>eng</language><publisher>United States</publisher><subject>Adult ; China ; Electrocoagulation - methods ; Female ; Humans ; Male ; Middle Aged ; Radio Waves ; Radiofrequency Therapy - methods ; Raynaud Disease - therapy ; Tomography, X-Ray Computed ; Treatment Outcome</subject><ispartof>Medical science monitor, 2019-10, Vol.25, p.7391-7395</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-4b395e609990bb9925fef9729bddc593abd1fa07a074e0a61b98f3cd57714b4b3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31576813$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Huang, Hao</creatorcontrib><creatorcontrib>Qiu, Weidong</creatorcontrib><creatorcontrib>Chen, Qunshan</creatorcontrib><creatorcontrib>Sun, Kai</creatorcontrib><creatorcontrib>Huang, Bing</creatorcontrib><title>Computed Tomography (CT)-Guided Percutaneous Thoracic Sympathetic Chain Radiofrequency Thermocoagulation for Raynaud Disease</title><title>Medical science monitor</title><addtitle>Med Sci Monit</addtitle><description>BACKGROUND We introduce a minimally invasive technique for the treatment of Raynaud disease - CT-guided percutaneous thoracic sympathetic chain radiofrequency thermocoagulation. MATERIAL AND METHODS Under CT guidance, the radiofrequency needle was punctured from the upper edge of the costotransverse joint to the anterior superior edge of the 4th capitulum costae and the lateral parietal pleura. After sensorial (1.5 mA, 50 Hz) and motorial (1.5 mA, 2Hz) testing to determine that there was no nerve innervation zone with muscle numbness and twitches, radiofrequency coagulation was set at 95°C for 300 s. RESULTS A total of 17 patients were enrolled in the treatment group. All the patients underwent CT-guided percutaneous thoracic sympathetic chain puncture of the needles to the upper edge of the 4th capitulum costae on both sides. The perfusion index (PI) of the fingers began to rise 30 s after radiofrequency thermocoagulation, and the palm temperature (T) began to rise after 90 s. At the end of treatment, PI increased by an average of 4.6-fold, and the T average rose by 3.6°C. Postoperative cold-water stimulation testing could no longer induce Raynaud disease. Follow-up was conducted for 1 to 15 months. Two patients were found to have recurrence at 9 months and 13 months, respectively. CONCLUSIONS CT-guided percutaneous thoracic sympathetic nerve chain radiofrequency coagulation can effectively treat Raynaud disease.</description><subject>Adult</subject><subject>China</subject><subject>Electrocoagulation - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Radio Waves</subject><subject>Radiofrequency Therapy - methods</subject><subject>Raynaud Disease - therapy</subject><subject>Tomography, X-Ray Computed</subject><subject>Treatment Outcome</subject><issn>1643-3750</issn><issn>1643-3750</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkE1LxDAQhoMo7rp68i49rkjXpOlXjlJ1FXZR3Hou-eo20jY1aQ8Ff7zBriIzMMPwzMvMC8AlgisUxBG53e62K4ISTIIjMEdxiH2cRPD4Xz8DZ9Z-QBikMYxOwQyjKIlThOfgK9NNN_RSeLlu9N7Qrhq9ZZZf--tBCTd-lYYPPW2lHqyXV9pQrri3G5uO9pXsXZ9VVLXeGxVKl0Z-DrLloyOlaTTXdD_UtFe69UptHDS2dBDevbKSWnkOTkpaW3lxqAvw_viQZ0_-5mX9nN1tfB6kpPdDhkkkY0gIgYwREkSlLEkSECYEjwimTKCSwsRlKCGNESNpibmIkgSFzG0vwHLS7Yx299m-aJTlsq6nt4oAQ4hSHLpYgJsJ5UZba2RZdEY11IwFgsWP3YWzu5jsdvTVQXhgjRR_7K-_-But63ya</recordid><startdate>20191002</startdate><enddate>20191002</enddate><creator>Huang, Hao</creator><creator>Qiu, Weidong</creator><creator>Chen, Qunshan</creator><creator>Sun, Kai</creator><creator>Huang, Bing</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20191002</creationdate><title>Computed Tomography (CT)-Guided Percutaneous Thoracic Sympathetic Chain Radiofrequency Thermocoagulation for Raynaud Disease</title><author>Huang, Hao ; Qiu, Weidong ; Chen, Qunshan ; Sun, Kai ; Huang, Bing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-4b395e609990bb9925fef9729bddc593abd1fa07a074e0a61b98f3cd57714b4b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Adult</topic><topic>China</topic><topic>Electrocoagulation - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Radio Waves</topic><topic>Radiofrequency Therapy - methods</topic><topic>Raynaud Disease - therapy</topic><topic>Tomography, X-Ray Computed</topic><topic>Treatment Outcome</topic><toplevel>online_resources</toplevel><creatorcontrib>Huang, Hao</creatorcontrib><creatorcontrib>Qiu, Weidong</creatorcontrib><creatorcontrib>Chen, Qunshan</creatorcontrib><creatorcontrib>Sun, Kai</creatorcontrib><creatorcontrib>Huang, Bing</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical science monitor</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, Hao</au><au>Qiu, Weidong</au><au>Chen, Qunshan</au><au>Sun, Kai</au><au>Huang, Bing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computed Tomography (CT)-Guided Percutaneous Thoracic Sympathetic Chain Radiofrequency Thermocoagulation for Raynaud Disease</atitle><jtitle>Medical science monitor</jtitle><addtitle>Med Sci Monit</addtitle><date>2019-10-02</date><risdate>2019</risdate><volume>25</volume><spage>7391</spage><epage>7395</epage><pages>7391-7395</pages><issn>1643-3750</issn><eissn>1643-3750</eissn><abstract>BACKGROUND We introduce a minimally invasive technique for the treatment of Raynaud disease - CT-guided percutaneous thoracic sympathetic chain radiofrequency thermocoagulation. MATERIAL AND METHODS Under CT guidance, the radiofrequency needle was punctured from the upper edge of the costotransverse joint to the anterior superior edge of the 4th capitulum costae and the lateral parietal pleura. After sensorial (1.5 mA, 50 Hz) and motorial (1.5 mA, 2Hz) testing to determine that there was no nerve innervation zone with muscle numbness and twitches, radiofrequency coagulation was set at 95°C for 300 s. RESULTS A total of 17 patients were enrolled in the treatment group. All the patients underwent CT-guided percutaneous thoracic sympathetic chain puncture of the needles to the upper edge of the 4th capitulum costae on both sides. The perfusion index (PI) of the fingers began to rise 30 s after radiofrequency thermocoagulation, and the palm temperature (T) began to rise after 90 s. At the end of treatment, PI increased by an average of 4.6-fold, and the T average rose by 3.6°C. Postoperative cold-water stimulation testing could no longer induce Raynaud disease. Follow-up was conducted for 1 to 15 months. Two patients were found to have recurrence at 9 months and 13 months, respectively. CONCLUSIONS CT-guided percutaneous thoracic sympathetic nerve chain radiofrequency coagulation can effectively treat Raynaud disease.</abstract><cop>United States</cop><pmid>31576813</pmid><doi>10.12659/MSM.917392</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1643-3750 |
ispartof | Medical science monitor, 2019-10, Vol.25, p.7391-7395 |
issn | 1643-3750 1643-3750 |
language | eng |
recordid | cdi_proquest_miscellaneous_2300183434 |
source | MEDLINE; PubMed Central Open Access; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Adult China Electrocoagulation - methods Female Humans Male Middle Aged Radio Waves Radiofrequency Therapy - methods Raynaud Disease - therapy Tomography, X-Ray Computed Treatment Outcome |
title | Computed Tomography (CT)-Guided Percutaneous Thoracic Sympathetic Chain Radiofrequency Thermocoagulation for Raynaud Disease |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T15%3A18%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computed%20Tomography%20(CT)-Guided%20Percutaneous%20Thoracic%20Sympathetic%20Chain%20Radiofrequency%20Thermocoagulation%20for%20Raynaud%20Disease&rft.jtitle=Medical%20science%20monitor&rft.au=Huang,%20Hao&rft.date=2019-10-02&rft.volume=25&rft.spage=7391&rft.epage=7395&rft.pages=7391-7395&rft.issn=1643-3750&rft.eissn=1643-3750&rft_id=info:doi/10.12659/MSM.917392&rft_dat=%3Cproquest_cross%3E2300183434%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2300183434&rft_id=info:pmid/31576813&rfr_iscdi=true |